MW KNX-20E-640 User manual

■
■
‧
‧
‧
‧
‧
‧
‧
‧Isolation classⅠ
‧
‧Installed on DIN rail TS-35/7.5 or 15
‧Ⅲ
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■ ■
640mA KNX Power Supply KNX-20E-640
Bauar
Sicher heit
egel gema
t gepru ft
od
be
www .
ID 2000000000
tuv. com
wac g
o s
File Name:KNX-20E-640-SPEC 2022-08-05
User’s Manual
■

SPECIFICATION
KNX-20E-640
MODEL
DC OUTPUT VOLTAGE WITHOUT CHOKE
RATED CURRENT
RATED POWER
OUTPUT
SHORT CIRCUIT CURRENT
SETUP, RISE TIME
AC MAINS FAILURE BACK-UP TIME(Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.) Note.3
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
CHOKE
LED DISPLAY
RESET
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION TYPE OF PROTECTION
MTBF
DIMENSION
MOUNTING
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 50ms/230VAC at full load
200ms/230VAC at full load
180 ~ 264VAC 230 ~ 370VDC
47 ~ 63Hz
86%
0.22A/230VAC
COLD START 40A/230VAC
<1mA / 240VAC
33 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
BS EN/EN61558-1,BS EN/EN61558-2-16;BS EN/EN50491-3, approved EAC TP TC 004
Compliance to BS EN/EN50491-5-2,-5-3;BS EN/EN61000-3-2,-3-3, EAC TP TC 020
Compliance to BS EN/EN50491-5-2,-5-3;BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035; heavy industry
level, EAC TP TC 020
-30 ~ +70℃ (Refer to "Derating Curve")
One integrated choke
Green LED (ON) :Normal operation
Physical button for reset the bus (Press the RESET button for at least 20 seconds to reset the KNX Bus)
20 ~ 95% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
1899.9K hrs min. Telcordia SR-332 (Bellcore) ; 416.5K hrs min. MIL-HDBK-217F (25℃)
52.5*90*54.5mm (W*H*D)
35mm mounting rail according to DIN BS EN/EN60715
0.215Kg ; 60pcs/13.9Kg/0.97CUFT
KNX-20E-640
30V(Additional output for ancillary power)
640mA
19.2W
100mVp-p
1.4A
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
FUNCTION
RIPPLE & NOISE (max.) Note.2
℃
http://www.meanwell.com
℃℃
※ : , https://www.meanwell.com/serviceDisclaimer.aspx
EMC IMMUNITY
EMC EMISSION
205 ~ 235% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.6KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
TYPE OF PROTECTION IP20 design
max
OVER VOLTAGE CATEGORY
Ⅲ;According to BS EN/EN61558, BS EN/EN50178,BS EN/EN60664-1, BS EN/EN62477-1;
altitude up to 2000 meters
BUS OUTPUT VOLTAGE WITH CHOKE
Bus,30V (KNX black/red terminal block)
Red LED1 (Reset):Reset the bus; Red LED2 (>):Overload/Short
Ⅰ Ⅰ
640mA KNX Power Supply
File Name:KNX-20E-640-SPEC 2022-08-05

INPUT VOLTAGE (V) 60Hz
180 200 220 240 264
100
90
80
70
60
50
40
LOAD (%)
AMBIENT TEMPERATURE (℃)
LOAD (%)
-30 0 10 20 30 40 50 60 70
20
40
60
80
100
(VERTICAL)
fosc :65KHz
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING FILTER
&
RECTIFIERS +V
BUS
-V
+V
-V
I/P
CONTROL
O.V.P.
O.C.P.
FG
MODULE
&
CHOKE
Mechanical SpecificationMechanical Specification Case No. KNX-20 Unit:mm
1
2
3
4
5
KNX bus termnials (Red :+, Black:-)
Reset button
Power ON (Green)
Reset (Red)
Ⅰ Ⅰ> max (Red)
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
35
6
Ancillary power termnials
KNX-20E-640
Derating Curve Static Characteristics
Block Diagram
58.5
54.5
90
63.7
45.2
52.5
7.5
7.57.5 24.06
7.255
7.45
7.45
4
+V
+V
-V
L N
-V
Reset
BUS
30VDC
5
6
1
3
BUS
without choke
without choke
1 standard unit (SU)=18mm
3SU
EIB/KNX
2
640mA KNX Power Supply
File Name:KNX-20E-640-SPEC 2022-08-05

KNX-20E-640
Bus wiring consideration:
Typical application
+V
+V
-V
L N
-V
Reset
BUS
30VDC
+V -V
L N
BUS
30VDC
+V -V
L N
BUS
30VDC
+V -V
L N
BUS
30VDC
Lighting device
KNX Bus
L
N
PE
1. the maximum number of bus devices connected is 64.
2. the maximum length of a line segment is 350 m, measured along the line between the power supply and the furthest device bus.
3. the maximum distance between two bus devices cannot exceed 700 m.
4. the maximum length of a bus line is 1000 m, keeping into account all segments.
5. It is possible to connect two KNX-20E-640 in parallel in same KNX line without minimum cable length.
KNX Bus
Note:
1. Use only ancillary output of KNX-20E-640 to power the KNX device
2. The total current + should be equal or less than 640mA. + ≤640mA
3. The above Bus wiring consideration is still applicable
Recommended Screwdriver, Wire and Torque Setting
1.Screwdriver(Width*Thick):Slotted screwdriver 2.5*0.4~3.5*0.6
2.Wire:0.5~4.0mm solid core or 0.5~2.5mm finely stranded
3.Torque:0.8Nm
Configuration and Commissioning
◎ Application 1:Powering KNX Bus Only
HV AC
System
device
Blinds &
Shutters
device
+V
+V
-V
L N
-V
Reset
BUS
30VDC
+V -V
L N
BUS
30VDC
+V -V
L N
BUS
30VDC
+V -V
L N
BUS
30VDC
Lighting device
L
N
PE
HV AC
System
device
Blinds &
Shutters
device
◎ Application 2:Powering KNX Bus and KNX device
+V -V
Ⅰ
1Ⅰ
2Ⅰ
1 Ⅰ
2
22
Ⅰ
1Ⅰ
2
640mA KNX Power Supply
KNX-20E-640
KNX-20E-640
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:KNX-20E-640-SPEC 2022-08-05
The application program(data base) for ETS can be downloaded via
http://www.meanwell.com/productCatalog.aspx
Other MW Power Supply manuals
Popular Power Supply manuals by other brands

Somogyi
Somogyi home MX 655/2 instruction manual

Spellman
Spellman V6 Series instruction manual

ABB
ABB CP-E Series Operating and installation instructions

Ryobi
Ryobi ONE+ RYi818BT Operator's manual

Rockwell Automation
Rockwell Automation Allen-Bradley PowerFlex SCR user manual

Kaboodle
Kaboodle W-50560 installation guide