mychway WL-517 User manual

3-1 40K Cavitation Ultrasonic RF Radio
Frequency Photon Slim
U ser Guide

t
C ontents
Ⅰ
.Structure
Structure
Structure
Structure of
of
of
of Cavitation
Cavitation
Cavitation
Cavitation
Ⅰ
-1. General Cavitation
Ⅰ
-2. Description of Applicator
Ⅱ
.Operation
Operation
Operation
Operation
Ⅱ
-1. Installation
Ⅱ
-2. Operating board
Ⅱ
-3. Finish
Ⅲ
.Practical
Practical
Practical
Practical Application
Application
Application
Application

Ⅳ
Cautions
Cautions
Cautions
Cautions
Ⅳ
-1. Contraindication
Ⅳ
-2. Caution when use
Ⅳ
-3. Maintenance
Ⅳ
-4. Solution
Ⅴ
.Warranty
Warranty
Warranty
Warranty
Ⅴ
-1. Warranty Coverage
Ⅴ
-2. Exclusions
Ⅵ
.Technicial
Technicial
Technicial
Technicial Parameters
Parameters
Parameters
Parameters
Ⅶ
.Packaging
Packaging
Packaging
Packaging Listing
Listing
Listing
Listing
Warming
Thanks for using our company's products, in order to fully make
use of the products, we sincerely suggests follow:
◆◆ Please read the instruction in detail and keep it well for further
reading and consulting.
◆◆ Please follow the instruction to fit and operate the machine
correctly.
◆◆ Please do not remove and change any accessories of the
machine.

◆◆ It forbids others to open and remove the mainframe except the
authorized people in the company.
◆◆ It forbids others to change and maintain the machine except
the professional people.
◆Please contact us if there is any trouble during operation.
This
This
This
This product
product
product
product does
does
does
does not
not
not
not belong
belong
belong
belong to
to
to
to medical,
medical,
medical,
medical, please
please
please
please don
don
don
don ’
’
’
’ t
t
t
t use
use
use
use for
for
for
for
disease
disease
disease
disease treatment!
treatment!
treatment!
treatment!
Ⅰ. Structure of Cavitation
Ⅰ-1. General Structure

Ⅰ-2. Description of cavitation
1.40K
1.40K
1.40K
1.40K STRONG
STRONG
STRONG
STRONG SOUND
SOUND
SOUND
SOUND WAVE
WAVE
WAVE
WAVE SYSTEM
SYSTEM
SYSTEM
SYSTEM Working
Working
Working
Working principle
principle
principle
principle
Sixpolar Laser RF head
Tripolar Laser RF head
40k cavitation head
LCD Screen
Power interface for Tripolar RF
Power interface for Sexpolar RF
Power interface for 40k cavitation

40K Strong sound waves explosion head effectively promote the organization
fat metabolism, repel orange peel fat, firming skin,
enhancing skin elasticity, etc. And the effect is long lasting. The 40 K sound
waves can make a implosion of liquid as the expansion and
compression of the wave make the inside of the liquid formed in many
small space and what inside this kind of space are gas and steam. During
the compression cycle, the 40K sound waves have positive pressure
effect on the liquid molecules, while during the expansion cycle the 40K
sound waves have positive pressure effect on the liquid molecules.
There are cohesion inside of liquid or and biological organization. Inside of the
low density fat cells, the cohesiveness of the molecular is weaker.
The low negative pressure which is produce by 40 K sound waves will
produce organization gap which is called "cavitation phenomenon" in
physics. The implosion of inside and outside of the cells will enhanced
the molecular motion and achieve a high energy level, and eventually led
to the bursting of the fat cells.
2. Multipolar circulation RF principle

Six polar RF Laser work head for body
Tripolar RF Laser work head for face
【Skin rejuvenation principle 】The circulation medical radio frequency
system in 1 seconds will change the electric polarity in electric field
millions times of the biological tissue of the therapeutic part ,
particles of the organization will do Brownian motion(molecular no rules
movement) as the same frequency which will make the organization produce
columnar distribution of heat, damage collagen hydrogen bonding
structure and change the collagen molecules of the three spiral structure,
and lead to the immediate collagen sex contraction and as a result of
thetreatment effect of firming skin;

According to ajusting the energy output, the circulation system makes
skin tissues have mild, moderate and severe heat aggression three
stages which is similar as the three stages in wound healing(inflammation
stage, growth stage, remodeling stage), improve leather remodeling shape,
so as to reconstruct the skin and dispel light, medium, heavy wrinkles
uteruses Calvin lines and the r skin flabby after losing weight. The
effect is long lasting.
【De-fatting body slimming principle 】The medical circulation RF
system will produce columnar distributed hea d in the subcutaneous
tissue and fully make triglycerides release from the fat cells. Under
the action of lipase the triglyceride will cracking into fatty acids and
glycerin, then eliminated from the body along with the metabolism.
Because of the intelligent system, the medical circulation RF instrument
can orientate the fat cells, and release triglycerides
quantificationally, thus achieved the localization, the effect of
reducing weight rationally and quantificationally.
Ⅱ. Operation
Ⅱ-1 : Installation
1. Insert 40K cavitation explode work head
2. Insert Tripolar RF work head for face
3. Insert Tripolar RF work head for body
4. Insert power supply line
5. Trun on the general power switch
6.Insert the key
Ⅱ- 2 . Operating Board

M ode:40k
1. Click module “ 40K CAVITATION ”
2 . System default working time is 30 minutes, time range is 0:00~ 45 :00
minutes, press to adjust minute.
3 . The system default worked time is 30 minutes, this worked time is
used to record the total time of the instrument worked. Before working,
it will be 30 minute.
4 . The system default Intensity is 0. t he intensity range is
0~ 10 (standard parameters), pressone time to change one unit of
standard parameters.
5. Click to increase the cavitation intensity, Click to decrease
the cavitation intensity.
6. Click , it starts working ,Click stop working .

Mode: Sexpolar RF
1. Click module “ SEXTUPOLE ”
2 . System default working time is 30 minutes, time range is 0:00~ 45 :00
minutes, press one time to change one minute.
3 . The system default worked time is 30 minutes, this worked time is
used to record the total time of the instrument worked. Before working,
it will be 30 minute.
4 . The system default Intensity is 0. t he intensity range is
0~ 20 (standard parameters), pressone time to change one unit of
standard parameters.
5. Click to increase the RF intensity, Click to decrease the RF
intensity.
6. Click to turn on/ turn off the laser.
7. Click , it starts working ,Click stop working .

Mode: Tripolar RF
1. Click module “ RF ”
2 . System default working time is 30 minutes, time range is 0:00~ 45 :00
minutes, press one time to change one minute.
3 . The system default worked time is 30 minutes, this worked time is
used to record the total time of the instrument worked. Before working,
it will be 30 minute.
4 . The system default Intensity is 0. t he intensity range is
0~ 20 (standard parameters), pressone time to change one unit of
standard parameters.
5. Click to increase the RF intensity, Click to decrease the RF
intensity.
6. Click to turn on/ turn off the laser.
7. Click , it starts working ,Click stop working .
Ⅱ- 3 . Finish

1. When finish the treatment, Click the button to stop working.
2. Turn off the power switch on the back of the machine.
3. Clean the accessories after treatment.
Ⅲ. Practical Applications
1. Operation schematic drawing of 40K cavitation explode work
head massage the fat of thigh in circles.
2. Operation schematic drawing of tripolar RF work head for
Body
Waist and abdomen care (25minutes ,2-3 days/time )
Massage to navel as center and gradually expanding the range
②Massage chest nest, both sides of former abdomen and below the
navel(into diamond) from inside to outside in circles.

③Concentrated the fat from 4 directions to navel as center.
④Massage from end of pelvis to groin in circles.
⑤Massage from inner rib to outer edge in circles.
⑥Massage back and forth from inner rib to outer edge in straight line
⑦Lifting from inner rib to outer edge after massage.
Hip and he lower part of the body care (30minutes ,2-3days/time )
Concentrated the fat to groin in circles or straight line.

3. Operation schematic drawing of Tripolar RF work head for face
①Massage the mandible center in circles to produce deep heat.
Massage lower jaw in lines.
③Massage the triangle zone of both sides of the face in circles.
Massage from jaw to angulus oris to ear in lines.

Ⅳ. Caution
Ⅳ-1 : Contraindication
Please avoid the treatment from these people or part as
below :
a. Pregnancy
b. Scarring, infection of the treatment area
c. History of keloid scarring
d. Use of medication known to induce photosensitivity
e. Fragile skin
f. Patients undergoing the surgical procedure without
consulting with a surgeon
g. Patients with tumors
i. Patients with serious disease
j. Patients with low/high blood pressure
Ⅳ- 2 :Caution when use
1. This equipment should be used by the person who took
a equipment training.
2. Avoid treating around eyes and thyroid, bones, lymph
nodes.
3. Avoid treating on cuts, eyeballs, insensate parts, ears.
4. In case of resting during treatment, please “ Start Off ” to

avoid over-output of the machine.
5. If the machine can ’ t operate in normal condition, please
turn off the power and contact the distributor or
manufacturer immediately.
Ⅳ-3 : Maintenance
1. After treatment, keep the power on about 3 minutes to make
inner board cooling.
2. Please keep Liposlim in the shade, avoiding direct lay of light.
3. Don ’ t drop the machine & keep it out of any shock.
4. Clean applicators after use.
5. Moving the machine, be careful not to drop applicators
Ⅳ-3 :Solution
Light of power switch is not on although turn the
power switch
a. Please check whether power cord is put to plug on the machine
b. Please check whether the key has insert the machine
Ⅴ. Warranty
Ⅴ-1 : Warranty Coverage
From the day of purchase, We guarantee two years warranty
service and 30 days of refund and exchange from the day you
recievmaintenance of the main unit warranty for free.(Except for

consumable parts)
Ⅴ- 2 : Exclusions
This warranty is void and invalid in case of :
a. Damage caused by accident, abuse, misuse or misapplication,it
will be repaired with repair fee .
b. Damage caused by service performed by anyone who is not
technician or qualifiedby manufacturer.
c.
A
product or part that has been modified without any permission
of manufacturer.
d. A Product that has no serial number.
Ⅵ. Technicial Parameters
Both 110v and 220v voltage (frequency: 50/60Hz) version are available.
Power:110W
40K cavitation head:
Power supply output:150V
Intensity:0-50w/cm2
Frequency:40KHz
Power:25W
Tripolar RF head for body :
Power supply output:66V
Intensity:0-25w/cm2

Freqeuncy:450K
Power:35W
Tripolar RF head for face
Power supply output:35V
Intensity:0-15w/cm2
Freqeuncy:450K
Power:35W
Ⅶ. Packaging Listing
1 pcs main machine
1 pcs 40KHz cavitation head
1 pcs tripolar RF head for body
1 pcs tripolar RF head for face
1 pcs heads holder
1 pcs key
1 pcs power supply plug ( we stock the USA, UK, AU, EU plug to suit for the