MZ Skin LIGHTMAX MINIPRO EYECONIC LED User manual

USER MANUAL
LIGHTMAX MINIPRO
EYECONIC™ LED

- 2 -
CONTENTS
ENGLISH EN 3-20
FRENCH FR 21-38
ITALIAN IT 3956
SPANISH ES 57-74
GERMAN DE 75-92
ARABIC AR 93109
RUSSIAN RU 110128
SIMPLIFIED CHINESE ZHCN 129143
TRADITIONAL CHINESE ZHTC 144156
CONTACT DETAILS 157

- 3 -
It is mandatory that users of this device read and comprehend
all information in this User Manual prior to use of the
LightMAX MiniPro Eyeconic™ LED.
You must follow all the instructions in the user manual.
Please contact us if you have any comments about the
LightMAX MiniPro Eyeconic™ LED device or this User Manual
or if you experience any side eects that are not mentioned in
this User Manual or are more severe than those described in
this User Manual.
www.mzskin.com
@mzskinoicial
RP: Certainty IP Ltd, Dublin, D18 CV48. +353 1582 9003
Emergo Australia,
Level 20 Tower II
Darling Park,
201 Sussex Street,
Sydney, NSW 2000
Australia
The information in this document is proprietary to MZ SKIN
Ltd, and supplied on the understanding that it shall be kept
confidential to recipients and that it shall not be reproduced
and/or used for commercial purposes without the written
consent of MZ SKIN Ltd.

- 4 -
Before using LightMAX MiniPro Eyeconic™ LED you must carry
out a sensitisation test and wait 6 hours.
TABLE OF CONTENTS
WHO SHOULD USE LIGHTMAX MINIPRO EYECONIC™ LED 5
DEVICE DESCRIPTION 5
INTENDED USE 6
CONTRAINDICATIONS, WARNINGS AND PRECAUTIONS 6
Contraindications 6
Warnings 7
General Safety 8
Precautions 8
RISKS AND BENEFITS 9
Potential Risks 9
FIRST TIME SETUP 9
Unpacking and charging your LightMAX MiniPro Eyeconic™ LED 9
Charging your LightMAX MiniPro Eyeconic™ LED 10
CHARGING STATUS OF THE LIGHTMAX MINIPRO EYECONIC™ LED 10
SENSITISATION TEST 10
USING LIGHTMAX MINIPRO EYECONIC™ LED 11
Treatment Recommendations 11
Carrying out a treatment 11
HOW TO USE THE HYDROCOLLOID PATCHES 12
CARE AND MAINTENANCE 13
CLEANING THE LIGHTMAX MINIPRO EYECONIC™ LED 13
DISPOSALRECYCLING 14
TROUBLESHOOTING 15
LABELLING 16
TECHNICAL SPECIFICATION 16
EXPLANATION OF SYMBOLS 16
WARRANTY 18
Standard Warranty 18
Warranty exceptions 18
What to do if your product is faulty 19
CHANGE LOG 20

- 5 -
WHO SHOULD USE LIGHTMAX MINIPRO
EYECONIC™ LED
Thank you for choosing LightMAX MiniPro Eyeconic™ LED. LightMAX MiniPro Eyeconic™
LED is suitable for adults wishing to treat facial wrinkles.
If, upon purchasing your LightMAX MiniPro Eyeconic™ LED device, you find that you are
photosensitive, please return the device to your provider within 14 days along with proof
of purchase.
DEVICE DESCRIPTION
The LightMAX MiniPro Eyeconic™ LED is a battery operated, cordless wearable light
emitting diode (LED) device intended to emit light in the red (630nm) and near infrared
(830nm) regions of the light spectrum for the treatment of facial wrinkles and helps reduce
the appearance of eyebags and puy skin.
The LightMAX MiniPro Eyeconic™ LED system consists of the following key components:
1. 2 x Silicone LED Patches
2. 2 x Magnetic 2 pin, 4mm to USB A Charging Cable
3. 29 x Individually wrapped Hydrocolloid Patches including 1 Sensitisation Patch
4. 1 x User Manual
5. 1 x Travel Pouch
LightMAX MiniPro Eyeconic™ LED is a silicone flexible patch containing LEDs. The LEDs
generate the light.
The LEDs produce red: (630nm ± 10nm) and near infrared (830nm ±10nm) light in the visible
spectrum. The device works through non-thermal mechanisms called Photobiomodulation.
The LEDs are driven by an integrated 3.7V, 37mAh Lithium Polymer battery.
The battery is charged via a magnetic 2 pin, 4mm to USB A connector that plugs into a
standard 5v USB A power adaptor. The device cannot be operated while in charging mode.
The charging status of the device is indicated by a single indicator LED on the rear of the
LightMAX MiniPro Eyeconic™ LED patches and the treatment LEDs.
In charging mode:
i. Solid green – Battery is fully charged.
ii. Solid orange – Battery charging.
The LightMAX MiniPro Eyeconic™ LED contains a simple ON/OFF button ( ) that switches
the LEDs ON/OFF. The treatment time is 10 minutes. The device automatically turns OFF
after the 10-minute treatment cycle. The user may stop the treatment program during the 10
minutes by pressing the ON/OFF button.
The LED patch is worn on the face and held in place by an adhesive hydrocolloid patch.
The adhesive hydrocolloid patch is impregnated on both sides with an elastomer and
hydrogenated petroleum resin that acts as an adhesive.
Hydrocolloid Ingredients: The hydrocolloid contains CMC Carboxymethyl Cellulose
(Cellulose Gum), Styrene/Isoprene Copolymer, Homopolymer, Hydrogenated Rosin,
Parainum Liquidum (Mineral Oil), PET, Niacinamide, Sodium Hydroxide, Sodium
Hyaluronate, Pentaerythritol Tetrakis and Oligopeptide-10.
You are supplied with 29 adhesive Hydrocolloid Patches for treatments, one of which must be

- 6 -
used to carry out a Photosensitivity/Patch test before starting your treatment course.
The equipment is not used to make measurements of any sort, or to draw any conclusions
regarding the indication to treat. The equipment does not require checks on the light output
as the LEDs do not dim with age to any practical extent.
INTENDED USE
The LightMAX MiniPro Eyeconic™ LED is an over-the-counter device intended to emit
energy in the red and near infra-red region of the light spectrum and is intended for use in
the treatment of facial wrinkles.
LightMAX MiniPro Eyeconic™ LED is intended to be used in the home by adults.
CONTRAINDICATIONS, WARNINGS AND
PRECAUTIONS
Contraindications
• DO NOT share LightMAX MiniPro Eyeconic™ LED with any other person.
The LightMAX MiniPro Eyeconic™ LED device is for single person use only.
• DO NOT reuse the hydrocolloid patches between treatment sessions.
The hydrocolloid patches are for single use only.
• DO NOT use LightMAX MiniPro Eyeconic™ LED to treat any other conditions apart
from those listed in the intended use. The LightMAX MiniPro Eyeconic™ LED device
has not been tested for any other conditions than those listed, and the risk is
unknown.
• Do NOT use LightMAX MiniPro Eyeconic™ LED or the hydrocolloid patches on
broken skin.
• Do NOT use LightMAX MiniPro Eyeconic™ LED if you are pregnant, planning on
becoming pregnant or breastfeeding. The LightMAX MiniPro Eyeconic™ LED
device has NOT been tested on pregnant or breast-feeding women and therefore
the risk to the foetus, neonate or pregnant women is unknown.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you have an allergy to Silicone
or Polyethylene Terephthalate. The treatment surfaces of the LightMAX MiniPro
Eyeconic™ LED contain medical grade silicone and Polyethylene Terephthalate.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you have an allergy to Hydrocolloid
bandages or any of the ingredients in the hydrocolloid patches outlined above. The
LED patch fixes to your face using an adhesive hydrocolloid patch.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you suer from light
induced headaches.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you suer from any genetic
conditions of the eyes. If you are unsure about any related eye condition and using
the LightMAX MiniPro Eyeconic™ LED, contact a health care professional.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you suer from lupus
erythematosus, photosensitive eczema, or albinism. If you use the LightMAX
MiniPro Eyeconic™ LED device to treat lupus erythematosus, photosensitive
eczema, or albinism you may cause a severe skin reaction.

- 7 -
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you suer from any
photosensitive disorder (sensitisation to light). If you use the LightMAX MiniPro
Eyeconic™ LED device and you suer from a photosensitive disorder; you may
cause a severe skin reaction.
• DO NOT use LightMAX MiniPro Eyeconic™ LED if you are taking any medication
that can cause photosensitivity. If you use the LightMAX MiniPro Eyeconic™ LED
device and you are taking any medication that can cause photosensitivity you may
cause a severe skin reaction.
• For a full list of drugs that can cause photosensitivity, please visit: https://www.
mzskin.com/lightmax-supercharged-led-precautions/
Photosensitivity is a common side eect of various medications. These can include
certain antibiotics, chemotherapy drugs, and diuretics. If you are unsure about any
medication you may be taking, consult your healthcare provider.
Other substances not listed above can also cause photosensitivity.
• Common examples of these substances are:
St John’s Wort, coal tar, deodorants, antibacterial soaps, artificial sweeteners,
naphthalene (mothballs), petroleum products, brightening agents found in
laundry detergent, and cadmium sulphide (a chemical injected into the skin
during tattooing).
Warnings
• Before using LightMAX MiniPro Eyeconic™ LED you must carry out a sensitisation
test. Please read the section “Sensitisation Test” on how to carry out the test.
• DO NOT over flex the LightMAX MiniPro Eyeconic™ LED device. Although it is
flexible, it is not designed to withstand excess bending or folding.
• Keep the LightMAX MiniPro Eyeconic™ LED device away from sharp objects.
• DO NOT use LightMAX MiniPro Eyeconic™ LED in any way that is not exactly as
specified in this User Manual. Use of the LightMAX MiniPro Eyeconic™ LED other
than exactly as specified in this user manual has not been tested and the risk is
unknown.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED or hydrocolloid patches in an
environment that is NOT specified by the manufacturer as this may cause damage
to the device or hydrocolloid patches or harm to the user.
• TURN OFF and REMOVE the LightMAX MiniPro Eyeconic™ LED immediately if it
feels hot or your skin feels uncomfortably warm. DO NOT continue treatments and
contact customer services.
• STOP using the LightMAX MiniPro Eyeconic™ LED during a treatment if you
experience headaches or changes in vision. DO NOT continue treatments and
contact customer services.
• DO NOT use LightMAX MiniPro Eyeconic™ LED without first removing creams,
lotions, or make-up BEFORE treatment. Some ingredients in these products may
cause light sensitisation or may reduce the eect of the treatment. If you use the
LightMAX MiniPro Eyeconic™ LED without removing these products, you may
cause a skin reaction, or may reduce the eect of the treatment.
• Only use the adhesive hydrocolloid patches recommended. Other adhesive

- 8 -
patches are available but have not been tested with the device and may block light
penetration and reduce the eects of the treatment.
• DO NOT use the hydrocolloid after its expiry date.
• NEVER use LightMAX MiniPro Eyeconic™ LED near water or where water can be
spilt onto the equipment. DO NOT use LightMAX MiniPro Eyeconic™ LED if you
think it has come into contact with water.
• Keep LightMAX MiniPro Eyeconic™ LED away from HOT surfaces or direct sunlight.
• DO NOT attempt to modify LightMAX MiniPro Eyeconic™ LED in any way.
Modifying LightMAX MiniPro Eyeconic™ LED will void your warranty. Modifying the
LightMAX MiniPro Eyeconic™ LED could cause an electric shock when the system
is used again. The system contains no serviceable parts.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED if the patch, cable or packaging
are damaged in any way.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED device any longer if it shows
any signs of damage to the material through wear and tear.
• Keep the LightMAX MiniPro Eyeconic™ LED and Hydrocolloid patches away from
children and pets.
• Electrical cables can present a strangulation hazard.
• DO NOT leave the LightMAX MiniPro Eyeconic™ LED unattended when it is
switched on. Accidental mishandling of the device could lead to the risk of fire or
burns.
General Safety
LightMAX MiniPro Eyeconic™ LED is an electrical device, which under certain circumstances
could present an electrical shock hazard to the user. Please read this user manual thoroughly
and follow directions stated in the manual to assure maximum safety during operation.
LightMAX MiniPro Eyeconic™ LED may only be charged with the charging cable that is
supplied with the device. Use of other charging cables may not be safe and could lead to
electric shock.
Precautions
• DO NOT stare directly at the LED light source.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED without a hydrocolloid.
• The LightMAX MiniPro Eyeconic™ LED device cannot be used in charging mode.
• Unplug the 2-pin charging cable from the USB charging point when not in use.
• Before each use, with the device switched o, clean the LightMAX MiniPro
Eyeconic™ LED device. All surfaces of the LightMAX MiniPro Eyeconic™ LED device
may be cleaned by following the cleaning instructions.
• DO NOT use any other cleansing products other than those stated in the cleaning
instructions. Use of other cleansing products may damage the LightMAX MiniPro
Eyeconic™ LED.
• Store LightMAX MiniPro Eyeconic™ LED and Hydrocolloid patches at room
temperature in dry conditions, away from direct sunlight.
• Don’t use LightMAX MiniPro Eyeconic™ LED in Direct Sunlight.

- 9 -
• Take care when removing the patch and hydrocolloid, as there is a risk of damaging
the top layer of the skin if it is removed too vigorously.
• DO NOT charge the LightMAX MiniPro Eyeconic™ LED if the USB socket or wall
adapter you are using has poor connections, is damaged or becomes hot. Make
sure you plug the device into a high quality, CE certified USB charging socket or
adapter to avoid the risk of fire and burns.
• DO NOT subject the LightMAX MiniPro Eyeconic™ LED to heavy shocks to avoid
risk of damage to the device, if you damage the device, do not use it any longer.
Precautions related to the hydrocolloid patches.
• Avoid direct contact with eyes. If contact occurs, rinse immediately with water.
• If the skin becomes irritated by the patch, rinse with water and stop use
immediately.
• For external use only.
RISKS AND BENEFITS
Potential Risks
This list although not exhaustive, lists what are considered to be among the mostly
likely adverse eects that could occur with use of the device.
Immediately after treatment skin may appear red. Skin should return to normal
within 1-2 hours.
Some users have reported pigmentation, skin flaking or peeling, associated pruritis
and dryness. This is transient and fades within a few days.
Temporary headaches may occur immediately following the light treatment.
Although this device emits levels of visible and infrared light that are considered to
be safe for the skin, if you have adverse reactions after using the device that do not
resolve, you should stop using the device immediately.
If you experience a side eect that is not described above or is of greater severity
than described above, please STOP using the device immediately and contact a
Healthcare Professional and MZ SKIN Ltd or your provider and your representative
Competent Authority if you deem it applicable.
Potential Benefits
People who have undergone a course of 3-5 treatments per week for 6 weeks using
LightMAX MiniPro Eyeconic™ LED report a reduction in facial wrinkles.
FIRST TIME SETUP
Unpacking and charging your LightMAX MiniPro Eyeconic™ LED
Unpack the LightMAX MiniPro Eyeconic™ LED and check o the parts described in Device
description.
Visually inspect the parts and connections. Return the device to your supplier if you think the
device or connecting parts or components are damaged or have been previously used.
Do NOT use the LightMAX MiniPro Eyeconic™ LED if you notice the device or connecting
parts or components are damaged.

- 10 -
Charging your LightMAX MiniPro Eyeconic™ LED
Before use, fully charge the device.
LightMAX MiniPro Eyeconic™ LED uses an integrated lithium-ion polymer battery. When
the LED patch is connected to the power supply do not attempt to use the device as the
LEDs will not illuminate.
1. To charge the LightMAX MiniPro Eyeconic™ LED connect the 2-pin connection
cable to the port on the upper side of the LED patch.
2. Insert the USB A connector into a suitable USB power supply or laptop port.
3. The indicator LED on the upper surface of the patch will illuminate orange to show that
the LED patch is charging. The patch is fully charged when the indicator LED is green.
4. When fully charged the battery will deliver 3-4 treatments before recharging. The
lifetime of the lithium battery can be maximized by allowing it to fully charge and
then fully discharge during regular use.
5. Always ensure the LED patch is fully charged before commencing a treatment session.
6. Unplug the 2-pin charging cable from the USB A charging port when not in use.
CHARGING STATUS OF THE LIGHTMAX
MINIPRO EYECONIC™ LED
LightMAX MiniPro Eyeconic™ LED uses a single display LED on the rear of the LED patch and
treatment LEDs to indicate the status of charging.
Solid Green – Battery is fully charged.
Solid Orange – Battery is Charging (Charging Mode)
Low Battery Mode - When there is insuicient battery capacity to complete a full treatment,
the Treatment LEDs will flash and the LightMAX MiniPro Eyeconic™ LED will turn OFF – You will
need to recharge the patch.
SENSITISATION TEST
Before carrying out your first treatment you must first carry out a sensitisation
test to see if you are sensitive to light or the adhesive hydrocolloid patch. Follow the
step-by-step guide below.
DO NOT attach the LightMAX MiniPro Eyeconic™ LED to your face, the sensitisation test
should be carried out on your inner arm.
1. Ensure the LightMAX MiniPro Eyeconic™ LED is fully charged.
2. Remove one of the adhesive hydrocolloid patches from its packaging.
3. See the “How to use the Hydrocolloids” section for a step-to-step guide to using
the hydrocolloids.
4. Unpeel the device side of the backing paper o the adhesive hydrocolloid patch.
5. Place the sticky side of the adhesive hydrocolloid patch onto the LED side (white)
of the LightMAX MiniPro Eyeconic™ LED. Ensure the adhesive hydrocolloid patch

- 11 -
aligns with the shape of the LightMAX MiniPro Eyeconic™ LED.
6. Press down across the entire surface of the adhesive hydrocolloid patch.
7. Peel the face side of the backing paper from the adhesive hydrocolloid patch.
8. Attach the LightMAX MiniPro Eyeconic™ LED to the inside of your left or right
forearm and push down gently.
9. Switch ON the LightMAX MiniPro Eyeconic™ LED and allow it to run for a full
treatment (10 minutes)
10. At any time if your skin feels HOT or uncomfortable STOP using the device
immediately.
11. After the treatment carefully remove the LightMAX MiniPro Eyeconic™ LED and
adhesive hydrocolloid patch from the treatment area. Discard the test adhesive
hydrocolloid patch in the general waste.
12. Wait at least 6 hours. If your skin on your inner arm is red or itchy, then the
treatment is unsuitable for you. Return the device to the retailer within (14) days
of purchase.
USING LIGHTMAX MINIPRO EYECONIC™
LED
Regarding electromagnetic compatibility (EMC) and electromagnetic fields (EMF), in
and around the home environment the LightMAX MiniPro Eyeconic™ LED should be kept
away from radio frequency (RF) equipment to avoid interference.
Treatment Recommendations:
For the treatment of facial wrinkles, the best results are seen by treating for 3-5
times a week for 6 weeks.
Maintenance treatment should be carried out as required, according to lifestyle
and skin condition.
Carrying out a treatment
DO NOT over flex the LightMAX MiniPro Eyeconic™ LED device. Although it is flexible, it is
not designed to withstand excess bending or folding.
DO NOT use the LightMAX MiniPro Eyeconic™ LED without a hydrocolloid.
1. Ensure LightMAX MiniPro Eyeconic™ LED is fully charged before commencing
treatment session.
2. Cleanse or exfoliate the skin to remove any traces of skincare.
3. Use a new hydrocolloid every treatment session.
4. See the “How to use the Hydrocolloids” section for a step-to-step guide to using
the hydrocolloids.
5. Unpeel the device side of the backing paper o an adhesive hydrocolloid patch.
6. Place the sticky side of the adhesive hydrocolloid patch onto LED side (white) of
the LightMAX MiniPro Eyeconic™ LED. Ensure the adhesive hydrocolloid patch
aligns with the shape of the LightMAX MiniPro Eyeconic™ LED.
7. Press down across the entire surface of the adhesive hydrocolloid patch.
8. Peel the face side of the backing paper from the adhesive strip.
9. Using a mirror position the LightMAX MiniPro Eyeconic™ LED over the treatment area.

- 12 -
10. Switch ON the LightMAX MiniPro Eyeconic™ LED. The device will automatically
switch OFF after 10 minutes. You may stop the treatment at any time by pressing
the ON/OFF button.
11. After the treatment, carefully remove the LightMAX MiniPro Eyeconic™ LED and
adhesive hydrocolloid patch from the treatment area.
12. Remove the adhesive hydrocolloid patch from LightMAX MiniPro Eyeconic™ LED
and discard in general household waste. If you would like to keep the hydrocolloid
patch on the treatment area after the LED treatment cycle has finished, press the
hydrocolloid patch onto the face using the tab and carefully peel the LED device
from the hydrocolloid patch.
13. Clean LightMAX MiniPro Eyeconic™ LED by following the instructions in “Cleaning
the LightMAX MiniPro Eyeconic™ LED device”. Ensure that the device is NOT being
charged when cleaning.
14. You may treat more than one treatment area in a treatment session.
DO NOT repeat a treatment on the same treatment area in the same session.
HOW TO USE THE HYDROCOLLOID
PATCHES
Face Side: Device Side:
Step-to-step Diagram for Using the Hydrocolloids.
Step 1
Peel the device side of the
hydrocolloid patch.
Step 2
Attach it to the LED device.

- 13 -
CARE AND MAINTENANCE
• The lifetime of the lithium battery can be maximized by allowing it to fully charge
and then fully discharge during regular use.
• Store LightMAX MiniPro Eyeconic™ LED at room temperature in dry conditions.
• Avoid storing LightMAX MiniPro Eyeconic™ LED in dusty conditions, in direct
sunlight or in damp and humid conditions.
• LightMAX MiniPro Eyeconic™ LED contains no serviceable parts.
• Before each use, with the device switched o, clean the LightMAX MiniPro
Eyeconic™ LED following the cleaning instructions below.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED device any longer if it shows
any signs of damage to the material through wear and tear.
• DO NOT use the hydrocolloid after its expiry date.
• DO NOT use the LightMAX MiniPro Eyeconic™ LED if it has been exposed to
environmental conditions outside of those specified in the Technical Specification.
CLEANING THE LIGHTMAX MINIPRO
EYECONIC™ LED DEVICE
• Before cleaning ensure that the charging cable is disconnected from the LightMAX
MiniPro Eyeconic™ LED and that the device is not charging.
• Clean the LightMAX MiniPro Eyeconic™ LED with a water-based wipe. Stubborn
stains or adhesive residue can be removed by wiping gently with 70% alcohol.
• DO NOT use water to clean LightMAX MiniPro Eyeconic™ LED.
• DO NOT use the device if you think it has come into contact with water.
Re-order
Refill Adhesive Hydrocolloid patches can be purchased from www.mzskin.com
Part number Description Quantity
HCR01 LightMAX MiniPro Eyeconic™
LED Hydrocolloidal Patches
20 per Box
Step 3
Once secured to the device, peel the face
side of the hydrocolloid patch.
Step 4
Press firmly
on the face in
the desired
treatment area.

- 14 -
DISPOSALRECYCLING
DO NOT dispose of the LightMAX MiniPro Eyeconic™ LED patch or charging cable
at a domestic waste facility. The adhesive hydrocolloid patch can be disposed of in
general household waste.
The LightMAX MiniPro Eyeconic™ LED contains a Lithium-ion polymer battery.
For protection of the environment, please package and return this unit to the
manufacturer or their representative at the end of its working life or safely dispose
of the device following your local guidelines.
The outer box packaging is recyclable.
The adhesive hydrocolloid patch can be disposed of in general household waste.

- 15 -
TROUBLESHOOTING
Problem Possible Cause Action
No light from
LightMAX MiniPro
Eyeconic™ LED.
Battery drained Connect the 2-pin connection cable to
the port on the upper side of the LED
patch. Insert the USB A connector into a
suitable USB port power supply or laptop
and charge until indicator light turns from
orange to green.
No red or infrared
light from LightMAX
MiniPro Eyeconic™
LED.
LightMAX MiniPro
Eyeconic™ LED
connected to an
electrical outlet.
Ensure that the indicator light is solid Green.
Remove the magnetic charging connector
from the LightMAX MiniPro Eyeconic™
LED and ensure that the charging cable is
unplugged from the charging source.
When the LightMAX
MiniPro Eyeconic™
LED is switched
on the Treatment
LEDs flash.
Insuicient battery
to complete a
treatment
Connect the 2-pin connection cable to
the port on the upper side of the LED
patch. Insert the USB A connector into a
suitable USB port power supply or laptop
and charge until indicator light turns from
orange to green.
During charging, the
Indicator light is not
illuminated and does
not illuminate.
No red or infrared light
from LightMAX MiniPro
Eyeconic™ LED.
LightMAX MiniPro
Eyeconic™ LED
is faulty
If your device is within warranty, return your
LightMAX MiniPro Eyeconic™ LED to the
point of purchase or Contact the Customer
Service email:
Treatment LEDs do
NOT turn OFF after
10 minutes
LightMAX MiniPro
Eyeconic™ LED
is faulty
If your device is within warranty, return your
LightMAX MiniPro Eyeconic™ LED to the
point of purchase or Contact the MZ SKIN
Ltd Customer Service email:
Treatment LEDs
flicker continuously
during treatment
LightMAX MiniPro
Eyeconic™ LED
is faulty
Ensure that the LightMAX MiniPro
Eyeconic™ LED is fully charged, and the
green light is illuminated. If the green light is
illuminated and the LEDs continue to flicker,
return the LightMAX MiniPro Eyeconic™
LED to the point of purchase or Contact the
MZ SKIN Ltd Customer Service email:

- 16 -
If the actions suggested fail to fix the problem, or the problem reoccurs and your LightMAX
MiniPro Eyeconic™ LED is within the warranty period, please return to the point of purchase
• Do NOT attempt to investigate any further.
• Do NOT attempt to modify the LightMAX MiniPro Eyeconic™ LED in any way.
The LightMAX MiniPro Eyeconic™ LED has NO parts you can repair yourself.
LABELLING
The labelling supplied with the device contains the following information:
• Date of manufacture
• Model number and batch code
• Operating environment
TECHNICAL SPECIFICATION
• Model Number: TN2189
• LEDs: Red: 630nm +/-10nm. NIR 830nm +/-10nm
• Total Intensity: 30mW/cm2
• Total Device Dimensions: Approx 68mm max (l) x 36mm max (w)
• Program time: 10 minutes +/- 11 Seconds
• Operating Temperature: 0°C to 30°C
• Storage and Transport Temperature: -5°C to 55°C
• Operating Humidity: 30% to 95% without condensation
• Storage and Transport Humidity: 20% to 85% without condensation
• Mains Electrical Input for charging: Any USB A Charger (5V)
• IP25
EXPLANATION OF SYMBOLS
There are several safety warnings on the LightMAX MiniPro Eyeconic™ LED and associated
packaging and in the user manual. Not following these warnings may result in one or more of
the following hazards: electrical shock and/or fire.
Caution
It is Mandatory to Read and Comprehend the Information
in the User Manual prior to using the LightMAX MiniPro
Eyeconic™ LED Device

- 17 -
Refer to the User Manual for Guidance on using the LightMAX
MiniPro Eyeconic™ LED Device
Applied part type BF.
LightMAX MiniPro Eyeconic™ LED is Single patient multiple use.
Conforms to certain EC Directives on health, safety, and
environmental protection standards. CE stands for ‘Conformité
Européenne’.
Conformity to UK Directives on health, safety, and
environmental protection standards. UKCA stands for UK
Conformity Assessed.
Manufacturer
Date of Manufacture
Keep Dry
Serial number
Model number for LightMAX MiniPro Eyeconic™ LED - TN2189
Batch Code
Unique device identifier
LightMAX MiniPro Eyeconic™ LED is a Medical Device (USA
and Aus Only)
Made in China

- 18 -
Keep away from Direct Sunlight.
Shows the lower and upper Temperature limits.
Shows the lower and upper Humidity limits.
The cardboard packaging that the LightMAX MiniPro
Eyeconic™ LED came in can be recycled.
Product shall not be disposed of with normal household waste
(2012/19/EU).
Input- 5V (USB A)
Emergo Australia,
Level 20 Tower II
Darling Park,
201 Sussex Street,
Sydney, NSW 2000
Australia
WARRANTY
Please register your warranty at www.mzskin.com
Standard Warranty:
Under normal use this product is guaranteed for 2 years after its original purchase date
against manufacturing defects in materials or workmanship.
Warranty exceptions:
This warranty extends only to the original purchaser.
This warranty does not cover damage caused by the following:
• Accident, misuse, abuse, or alteration
• Servicing by unauthorized persons
• Connection to incorrect power sources
• Use with unauthorized accessories

- 19 -
WHAT TO DO IF YOUR PRODUCT IS
FAULT Y
If the product should become faulty within the warranty period, contact your place of
purchase.
MZ SKIN Ltd or its authorised distributor reserves the right to replace a defective product
with the most compatible product currently available.
MZ SKIN Ltd or its authorised distributors shall not be responsible for any incidental, special
or consequential damages resulting from the use of this product. All implied warranties,
including but not limited to implied warranties of fitness and merchantability are limited in
duration to one year from date of original purchase.
This warranty gives you specific legal rights, and you may also have other rights that vary
from country to country. Some countries do not allow the exclusion or limitation of incidental
or consequential damages, or limitations on how long an implied warranty lasts, so some of
the above limitations and exclusions may not apply to you.
This warranty is given in lieu of all other warranties, written or oral, whether expressed by
airmation, promise, description, drawing, model or sample. All warranties other than this one,
whether expressed or implied, including implied warranties of merchantability and fitness for
a particular purpose are hereby disclaimed.

- 20 -
I-Smart Development Ltd
129 Green Lanes
Sutton Coldfield
West Midlands
B73 5LT
United Kingdom
User Manual Date: 2023-06-13 Version 3
DOC-4052 V0
This manual suits for next models
1
Table of contents
Languages:
Other MZ Skin Personal Care Product manuals