manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Najm Alfarqadain
  6. •
  7. Door Opening System
  8. •
  9. Najm Alfarqadain M-238 Technical manual

Najm Alfarqadain M-238 Technical manual

Operation Instruction
M-238 Autodoor switch for special room Make your choice
USA FCC
Part 15
Indoors
International
level
Thank you for purchasing, please read this instruction
before installation.
Operation
!
6
Safety Instruction
1
Overview of product
3
Applications
2
使用中
開 OPE N
OCCU P I E D
CLOSE
施鎖中
LOCK E D
開 OPE N
CLOSE
Exterior panel
Open button
OCCUPIED
indicator light
Door Close
Button
LOCKED
indicator light
Door Close
button
84mm
245mm
60mm
170mm
52mm
Screw hole
4PCS
Wiring
Terminal
14mm
13mm
112mm
Panel Pan
This system design with large press panel for operation.
With braille, Chinese, English, and have voice and light prompt .
Suitable for all kinds of people.
Easy wiring with exterior panel and inner panels.
This product has service time remind function.
Be used for psyciotherapy room, nursing room,
bathroom and office etc.
Exterior panel
【1】
On standby mode, OPEN Button on exterior panel lights, OPEN Button and
CLOSE button are light on inner panel.
Inn e r pane l
Autodoor open after pressing OPEN Button on exterior panel.
With Voice Prompt "Door is opening".CLOSE button on inner panel lights.
【2】
Dial switch setting
ON
TIME
5S15s15mins manually
1 2 121 2 1 2
Open the cover of CLOSE Button on inner panel
Adjust the position of the speaker volume,
clockwise adjust for high volume,
counterclockwise to adjust for low volume.
【1】
【2】
4Noti ces
The right way to open cover
The right way to cover the top cover
4PCS square holes
on Bottom Pan
speaker volume adjuster
5
Inner panel
Open button
Setp1:Mat with one piece of paper on cover to avoid
surface scratch.
Step 2:Use a small screwdriver to pry slightly.
Step 3: Surface cover is opened.
4PCS stand column on cover
Note: Match 4pcs square holes on bottom pan
with 4Pcs stand columns on cover and
then press.
Setting door close back .delayed time for after door open,
Dial switch setting
Exterior panel I nner panel
The service time of this system is 30mintues. System will issue
voice prompt when service time only 5 min left.
The system will cancel the locked function in 5 minutes, if continue using press
confirmation button or press CLOSE Button, Using time can be extended for
30 minutes more .Otherwise door will be open in 5 minutes.
【7】
Emergency operation
7
EMERGENCY
Emergency open by exterior panel
Press OPEN button on inner panel, door open with voice prompt
" door is opening". only CLOSE button on exterior and inner panel are both bright.
【5】
【6】
After entering, Press CLOSE button on inner panel, door shut and locked,
with voice prompt"Door is closing" OPEN button and LOCKED button are
both light on inner panel.
OCCUPIED button on exterior panel lights simultaneously. Open button
and Close button are not bright. If people outside press any button of exterior
panel, system will have voice prompt: “OCCUPIED",and door will not open.
【3】
【4】
8
Inner panel
NO
COM TOILET
AC/DC
12V~36V
COM
NO
1
Gr /Wh.
.
Green
Or /Wh
. .
Blue
Bl /Wh
. .
Orange
Br /Wh
. .
Brown
4
5
6
3
8
7
1
2
3
4
5
6
7
8
2
Power input
Door open signal
Extend service
time button
Loudspeaker
Exterior Panel
Light
( switching signal)
Working Voltage A C/DC 1 2∽36V
Standby current 80mA(12Vpower
Action current 160mA(12VPower)
Panel size 245mm(L)×84mm(W)×14mm(H)
)
Parameter
10
9Exterior&Inner Panel wiring
NO
COM
TOILET
Press button to confirm
extend service time.
Exte r ior panel In n er panel
Press CLOSE button
to extend service time.
Inn e r panel
Exte r ior pa n el Inner p anel
Door will be shut and close back according to setting time of dial switch. Or
press CLOSE button on exterior panel, door will be closed. Door close with
voice prompt" Door is closing" OPEN button on Exterior panel lights.
OPEN & CLOSE button on inner panel are both bright. System get back to
standby mode.
Input and Output
Light
( switching signal)
Exterior Panel Inner panel
1
Gr /Wh.
.
Green
Or /Wh
. .
Blue
Bl /Wh
. .
Orange
Br /Wh
. .
Brown
4
5
6
3
8
7
2
AC/DC
12V~36V
COM
NO
Power i nput
Door op en signal
Exte nd serv ice
time b utton
Loudspeaker
The way for emergency open by exterior panel.
Press CLOSE button 3S,After OPEN&CLOSE button flashing 3 times,
and then hold to press CLOSE button at once and press OPEN button
5 times continuously. Door will open with voice prompt “ Door is opening”
and system get back to standby system.
The way for emergency LOCK by exterior panel.
Emergency LOCK by exterior panel
Press OPEN Button for 3S, after OPEN&CLOSE button flashing 3 times, and then
hold to press OPEN button at once, and press CLOSE button 5 times continuously.
System will issue voice prompt" door is closing" All functions of Exterior and inner
panel do not effect.
The way for UNLOCK system: Operate EMERGENCY OPEN steps.

Popular Door Opening System manuals by other brands

hager 8300 Series Installation and service manual

hager

hager 8300 Series Installation and service manual

Krownlab RORIK installation instructions

Krownlab

Krownlab RORIK installation instructions

Elvox 2900 Series Wiring diagram

Elvox

Elvox 2900 Series Wiring diagram

ENFORCER SM-226LQ manual

ENFORCER

ENFORCER SM-226LQ manual

Siemens SIRIUS 3RV19 6 2 Series operating instructions

Siemens

Siemens SIRIUS 3RV19 6 2 Series operating instructions

Assa Abloy Norton LEO 5700 Series instructions

Assa Abloy

Assa Abloy Norton LEO 5700 Series instructions

Easi-Exit DCF2003 installation instructions

Easi-Exit

Easi-Exit DCF2003 installation instructions

Nabco ICU 2400 owner's manual

Nabco

Nabco ICU 2400 owner's manual

Cal-Royal N-CVRESC Instructions for use

Cal-Royal

Cal-Royal N-CVRESC Instructions for use

B&D Controll-A-Door Smart SDO-7 installation instructions

B&D

B&D Controll-A-Door Smart SDO-7 installation instructions

Raynor General II WLEDRGD manual

Raynor

Raynor General II WLEDRGD manual

BEA Flexir Assembly Dimensional drawing

BEA

BEA Flexir Assembly Dimensional drawing

Dorma TS93 T installation guide

Dorma

Dorma TS93 T installation guide

BFT BRCT Installation and user manual

BFT

BFT BRCT Installation and user manual

Beninca JIM.3 manual

Beninca

Beninca JIM.3 manual

GEZE Slimdrive EMD Invers Installation and service instructions

GEZE

GEZE Slimdrive EMD Invers Installation and service instructions

Assa Abloy G-CO-C Mounting instructions

Assa Abloy

Assa Abloy G-CO-C Mounting instructions

SAINT-GOBAIN SEVAX MINOS+ manual

SAINT-GOBAIN

SAINT-GOBAIN SEVAX MINOS+ manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.