NAPCO FIREWOLF User manual

Gem-C Firewolf Series 24V Commercial
Intelligent Addressable Fire Panel,
NFPA72-compliant, 96 outputs, 4 onboard
NACs (6.5A total), expandable to 24, built in
Sync/Strobe/Horn Module (System Sensor &
Wheelock) and dual line DACT plus optional
TCP/IP reporting. Nearly a mile., max. wire
run – any wire type –ideal for retrofits. Also
supports legacy and conventional devices,
too. Powerful battery capacity up to 32Ah
total.
Features remote smoke obscuration
reporting
4 More zones/points – up to 255
4 More power – 7 amps
4 More NAC’as – 4 on board
4 Built in strobe/horn sync
4 More standby power
4 32 Amp hour battery capacity
4 Regulated 24V output
Compliances - NFPA 72, UL Commercial
Fire, UL864 9th Ed., UL985. (CSFM, FM, MEA
listings pending.)
NAC Extender provides nearly 7A and
4 onboard NACs with up to 2A ea; up to
16Ah total battery capacity. Easily distributes
synched bell and strobe outputs with built
in module. Monitors AC, battery trouble,
tamper and ground fault on Napco bus or
provides universal FACP support.
Regulated Auxiliary Power Supplies
Commercial fire, 12V regulated 2A models;
or 1.75A version with plug-in transformer
Firewolf Advanced Analog Addressable
Commercial Fire Devices support auto-drift
compensation and maintenance alert function
Gemini-C New UL Commercial Wireless
Line with supervised tamper & automatic,
continuously supervised signal strength
(requires no manual test activation).
Firewolf Menu-Driven Custom Alpha
Keypads Same familiar Napco ez-
programming and usage. (Keyswitch support,
too.)
Napco Commercial
Firewolf Series:
Robust, flexible
24V commercial fire
systems supporting
up to 255 zones/
points using all-new
fire devices in hardwire,
wireless, conventional
& addressable
technologies
24V Addressable &
Conventional Fire
255, 128 or 32 point kits
Introducing the all new
SYSTEM
•Main Control board supports up to two (2) Addressable Fire SLCs
(addressable Signaling Line Circuit controllers). (Note: Only 1 SLC is
accomodated within the Medium panel enclosure.*)
•Fire 4-wire bus for keypads and non-SLC (conventional) devices,
including 12V devices
•Power Supply includes either 4A or 7A @ 24V
•RS-232 Printer Module for optional onsite parallel printer
•Supports up to 7 fire keypads, GEMC-FK1, mounted anywhere on the
bus. (As few as one keypad required on system for equipment savings.)
•Easy-to-use Gemini-style menu-driven operation with backlit custom
alphanumeric display and functionality for
Reset, Acknowledge, Silence (with disable).
•Full Keyswitch Support
•Synch module built in on each NAC (System Sensor & Wheelock
protocols)
•Dual Phone Line built in
•2 On board serial ports - one for internet reporting; one for
high-speed local downloading
•TCP/IP Internet reporting module
•Regulated Auxiliary Power Supplies - Commercial fire, 12V regulated
2A or 1.75A version with plug in transfomer
• Addressable SLC Loop Isolator (optional use - for some fire
applications requiring increased circuit integrity, e.g., meets Class A,
Style 7 loop requirements.
•Choice of two enclosures - Between the studs enclosures, recess or
surface mount –
• Larger version supports up to 32 AH at 24V. Dimensions: 24” x
14.25” x 5.2” (H x W x D) without cover. Removable battery shelves,
accommodate pairs of 7Ah, 7.5Ah and 8Ah batteries, etc.
•Medium Enclosure – supports 16 AH at 24V. Dimensions: 16”x
14.25” x 5.2” (H x W x D) without cover. (*Note: Only 1 SLC is
accomodated.) 16Ah battery backup capacity.
INPUTS
Up to 255 Zones. Zones can come from any of the following
initiating devices:
•Addressable SLC Loop – supports up to (2) 126 point loops
•Commercial RF Receiver –
•Supports Commercial Wireless Fire devices
•Wireless Smoke Detector
•Wireless Heat Detector
•Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire
bus or SLC loops
•Conventional 2-wire or 4-wire smoke detector input module
•SLC Fire Devices Supported:
•Analog Smoke Detector
•Analog Heat Detector
•Duct Detector
•Pull Station
•Conventional Zone Module
•Short Circuit Isolator
OUTPUTS
Up to 96 outputs
•Four on board Class B or 2 Class A NAC circuits, 2 amps each, total 6.5
amps at 24V
•Built in Wheelock and System Sensor NAC sync/strobe/horn protocol
allows initial silence of audible appliances while maintaining visual
notification, without the use of additional modules.
•Addressable SLC Fire Devices: Supervised relay, unsupervised relay
•Fire 4-wire bus devices: 8 zone form C relay (GEMC-RM3008), 8 open
collector output (GEMC-OUT8)
Advantages
•Easy Wire Compatibility - Addressable SLC
controller supports shielded, unshielded,
twisted and untwisted wire - ideal for retrofits
•Longer SLC loop lengths, support more
device loads each, too (see below for
distance at maximum device load in alarm/
standby each):
•10,000 ft. #14AWG •6,200 ft. #16AWG •
4,000 ft. #18AWG
•Support for Legacy and Existing Notification Appliances -One
NAC output configurable for 12V for compatibility for easy retrofit
compatibility
•UL Regulated NAC outputs
•Automatic drift compensation for smoke detectors
•Keypads mount anywhere on the bus and have flash-able firmware –
for updates via Quickloader command (# GEMC-FK1, shown above)
•Programmable obscuration level by smoke detector device
•Smoke Obscuration Report genererated remotely or locally or in any
of 3 ways - Quickloader device sensitivity report allows the printout of
a report for the AHJ listing the current status of all smoke detectors
in the system including the programmed obscuration level and the
actual sensitivity reading for each device. This report can be generated
remotely (uploaded) or locally through notebook PC or use optional
onsite printer.
•Full line of UL Commercial Devices for more flexibility & labor-savings
Example, Use Gemini Commercial Wireless 2-input module (GEMC-
WL-WD2) to convert any UL listed fire device into a UL wireless device,
ideal for sprinkler supervisories or for use with pull stations (mounts on
top of wall/conduit or in deep sngle-gang box (plastic).
•Separate 7Amp 4-NAC Extender (GEM-NAC7) 4 onboard NACs with
up to 2A ea., expandable for up to 24 per system. Up to 16Ah total
battery capacity. Regulated 24V Aux. power. Monitors AC, battery
trouble, tamper and ground fault on Napco bus -Also Provides
Universal FACP support for easy standardization in upgrades
(Shown above)
32-Point GEM-C Firewolf™ 24V Commercial Fire System
Agencies
NFPA 72, UL Commercial Fire, UL864 9th Ed., UL985. (CSFM, FM,
MEA listings pending.)
Napco Commercial™Firewolf-Series Components
for 32 to 255 Point 24V Commercial Fire Systems:
2-WIRE
FIRE SLC
ADDRESSABLE
LOOP
MOTHERBOARD
GEMC-FW-SLC
FIRE
SLC MODULE
(MAXIMUM 2)
GEMC-FW-SLC
FIRE
SLC MODULE
(MAXIMUM 2)
BATTERIES
4 OR 7 AMP MAIN
POWER SUPPLY
(GEMC-PS24V7A-R or
GEMC-PS24V4A-R)
GEMC-NL-MOD
INTERNET
REPORTING
GEMC-24VR
24 VOLT
BOOSTER
MODULE
FIREWOLF-SERIES
LARGE ENCLOSURE (SHOWN)
BATTERIES
ADDRESSABLE
SMOKE
DETECTOR
FWC-FSLC-SMK
FWC-FSLC-HEAT
ADDRESSABLE
HEAT
DETECTOR
FWC-FSLC-PULL
ADDRESSABLE
PULL STATION
PULL
(TELCO 1 REMOTE DOWNLOAD / REPORTING)
FWC-FSLC-EZM2
DUAL INPUT
MONITOR MODULE
F
I
R
EW
O
L
F
FWC-FSLC-DUCT
DUCT DETECTOR
F
I
R
EW
O
L
F
2 SLC MODULES, max.
Note: The four GEMC-RECV max. is reduced by 1 for each SLC module.
(TELCO 2 SECOND REPORTING LINE)
UP TO 126
DEVICES
SMOKE DETECTOR
GEMC-WL-SMK
GEMC-WL-HEAT
HEAT DETECTOR
SINGLE ZONE
TRANSMITTER
WITH TAMPER
GEMC-WL-WD2
Single Fire
initiating
N/O device
GEMC-NAC7
NAC EXTENDER
(5, MAX.)
BATTERIES
BATTERIES
GEMC-F8ZCPIM
8 Fire Zone Expander
}
8 ZONES OF
CONVENTIONAL 2-WIRE SMOKES
PULL STATIONS AND/OR HEAT DETECTORS
4 OR 7 AMP MAIN POWER SUPPLY
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
}
•4 ON-BOARD NAC
CIRCUITS (CLASS B)
(NOT SHOWN)
-- or --
•2 ON-BOARD NAC
CIRCUITS (CLASS A)
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
GEMC-RECV
WIRELESS
RECEIVER
FIRE BUS DEVICES
GEMC-EZM8
8 ZONE
CONVENTIONAL
ZONE EXPANSION
MODULE
GEMC-OUT8
8 ZONE OUTPUT
REMOTE RELAY
MODULE
GEMC-RM3008
OUTPUT
MODULE
GEMC-FPRINT
PRINTER
MODULE
GEMC-12V2APS-CF
12V AUX POWER
SUPPLY
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
FWC-FSLC-EZM1
FAST RESPONSE
MONITOR MODULE
FWC-FSLC-RM2
DUAL RELAY
MODULE
F
I
R
EW
O
L
F
FWC-FSLC-SOM1
SUPERVISED
OUTPUT MODULE
F
I
R
EW
O
L
F
FWC-FSLC-CZM
CONVENTIONAL
ZONE MODULE
F
I
R
EW
O
L
F
FWC-FSLC-ISO
SHORT CIRCUIT
ISOLATOR
F
I
R
EW
O
L
F
FWC-FSLC-SMK6B
(6" BASE ONLY)
FIRE KEYPAD
GEMC-FK1
(4, MAX.)
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
}
•4 ON-BOARD NAC
CIRCUITS (CLASS B) (SHOWN)
-- or --
•2 ON-BOARD NAC
CIRCUITS (CLASS A)
MUST BE ALL
WHEELOCK OR ALL
SYSTEM SENSOR
FIREWOLF SYSTEM COMPONENTS
Napco Commercial Fire Kits
GEMC-FW-255KT 255 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
• 24V Panel, 255 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A
notification power
• 7 Amp, 24V Power Supply
• Built in horn/strobe synch. module on each NAC
• Built in dual line communicator; dual onboard serial ports
• Quickloader up/downloading including remote smoke obscuration reporting
• Locking, Large Red Enclosure, 16 x 25” reversible door, with 14.25” x 25” base. Houses up to 32Ah battery backup.
• Menu-driven LCD Fire Keypad mounts anywhere on bus. (Also, full keyswitch support)
GEMC-FW-128KT 128 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
As above, but with
• 24V Panel, 128 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A
notification power
GEMC-FW-32KT 32 Point GEM-C Firewolf™ 24V Commercial Fire System Kit
Similar to above, but with
• 24V Panel, 32 Points via commercial addressable, wireless or conventional fire devices, 2 on board NACs providing up to 4A
notification power
• Locking, Medium Red Enclosure, 16 x 17” reversible door, with 14.25” x 16” base. Houses up to 16Ah battery backup.
Conventional Fire System Peripherals
GEMC-FK1 LCD Fire Red Keypad (Menu-driven operation, functionality for Reset, Acknowledge, Silence (with disable).
GEMC-F8ZCPIM Conventional 8-zone 2-wire fire input module. Plugs into motherboard, for conventional 2-wire smoke detectors or
any conventional fire detection device.
GEMC-EZM8 8-point expansion module
GEMC-NL-MOD Internet Reporting Module
Wireless Firewolf Peripherals
GEMC-WL-SMK Gemini Comml Wireless Smoke, Photoelectric
GEMC-WL-HEAT Gemini Comml Wireless Heat, 135º F
GEMC-WL-WD2 Gemini Comml Wireless 2-input module
GEMC-REVC Gemini Commercial Wireless 255 point RF Receiver (Up to 4 per system, max.)
Addressable Firewolf Peripherals
GEMC-FW-SLC Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices, below. Up to 2 connect to Panel.
FWC-FSLC-SMK Addressable Analog SLC Smoke, photoelectric, head**
FWC-FSLC-HEAT Addressable Analog SLC Heat, 135ºF, head**
FWC-FSLC-DUCT Addressable SLC Duct smoke detector, photoelectric
FWC-FSLC-EZM2 Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indep. contact monitoring
circuits, for pull stations, water flow and other dry contact alarm initiating devices.
FWC-FSLC-EZM1 Addressable SLC 1-input conventional module, similar to usage above.
FWC-FSLC-CZM Addressable SLC single module, for montoring of dry contacts, ie., pull stations and conv. smokes
FWC-FSLC-RM2 Addressable SLC 2-output module (requires 1 SLC address)
FWC-FSLC-ISO Addressable SLC Short Circuit Module (Optional: For special applications, meets Class A, Style 7 loop reqts.)
FWC-FSLC-SOM1 Addressable SLC Fire supervised output module. Application examples: elevator recall, HVAC shutdown, add’l NAC output w/
power supply
FWC-FSLC-PULL Addressable SLC Fire Pull Station
FWC-FSLC-PROG2 Tool for address-programming SLC devices
FWC-FSLC-SMK6B ** Smoke/Heat 6"Base, required for FWC-FSLC- SMK and –HEAT devices
Output Options
GEMC-NAC7 Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16” can, connects to 120VAC, supports 32Ah
standby batts. Supervised, fire bus connection. System Sensor and Wheelock NAC synch. (5/system, for 20 add’l NAC circuits ttl.)
GEMC-12V2APS-CF 12VDC Power Supply for Fire Bus, remote supervised. Direct 120VAC connection, supports 2ea. 12V, 7Ah standby batts.
GEMC- FPRINT Parallel printer module
GEMC-RM3008 8 Form C Relay Output Module
GEMC-RS232 RS232 Adapter for serial output from Panel
GEMC-OUT8 PGM Output Module, 8 open collector PGM outputs
NAPCO COMMERCIAL FIREWOLF SERIES SYSTEM ORDERING INFO.
NAPCO Security Technologies, Inc.
www.napcosecurity.com
1-800-645-9445 • 631-842-9400
Amityville, NY USA
August 2010, Specifications subject to change A601

This manual suits for next models

4

Other NAPCO Smoke Alarm manuals

NAPCO GEM-SMK User manual

NAPCO

NAPCO GEM-SMK User manual

NAPCO GEM-SM User manual

NAPCO

NAPCO GEM-SM User manual

NAPCO FIREWOLF FW-2S User manual

NAPCO

NAPCO FIREWOLF FW-2S User manual

NAPCO GEMC-WL-SMK User manual

NAPCO

NAPCO GEMC-WL-SMK User manual

NAPCO FIREWOLF FW-2-E User manual

NAPCO

NAPCO FIREWOLF FW-2-E User manual

NAPCO FW-2 User manual

NAPCO

NAPCO FW-2 User manual

Popular Smoke Alarm manuals by other brands

Panasonic 2318 Specification sheet

Panasonic

Panasonic 2318 Specification sheet

EVERSPRING SF804 user manual

EVERSPRING

EVERSPRING SF804 user manual

pyrexx XSD200 operating manual

pyrexx

pyrexx XSD200 operating manual

System Sensor FAAST LT Control guide

System Sensor

System Sensor FAAST LT Control guide

Simplex MINIPLEX 4100ES Series installation guide

Simplex

Simplex MINIPLEX 4100ES Series installation guide

Solo 365 user manual

Solo

Solo 365 user manual

American Sensor SA360 user manual

American Sensor

American Sensor SA360 user manual

RED R9 installation instructions

RED

RED R9 installation instructions

MGC MIX-4020 Installation and maintenance instructions

MGC

MGC MIX-4020 Installation and maintenance instructions

Flamingo FA23B user manual

Flamingo

Flamingo FA23B user manual

System Sensor DH400ACDCIHT Installation and maintenance instructions

System Sensor

System Sensor DH400ACDCIHT Installation and maintenance instructions

Brooks EIB605C Photoelectric quick start guide

Brooks

Brooks EIB605C Photoelectric quick start guide

Aico Ei175 Instruction leaflet

Aico

Aico Ei175 Instruction leaflet

Silent Call Communications SD4-SS Installation and operation manual

Silent Call Communications

Silent Call Communications SD4-SS Installation and operation manual

Kidde KF1 user manual

Kidde

Kidde KF1 user manual

Rielta Ladoga PD-RK installation guide

Rielta

Rielta Ladoga PD-RK installation guide

Smartek NB40LPS1 manual

Smartek

Smartek NB40LPS1 manual

FireAngel EZ-212 user manual

FireAngel

FireAngel EZ-212 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.