This drawing is the property of Wolf Steel LTD. or NAC.
It is not to be reproduced nor used in any manner
without our consent. All rights are reserved.
08/27/14 AGR
A
B
C
D
12345
A
B
C
D
REV.
15
4
32
TOLERANCES:
MM/DD/YY: 03.21.16
MM/DD/YY: 04.01.16
.010VELVETMATTELEXANAND/OR.050HI-TEMPPOLYESTER
W385-2134 / A
CONFORMSTO/CONFORMEAUX:ANSIZ21.50-2014,CERTIFIEDTO/CERTIFIECSA2.22-2014VENTEDGASFIREPLACE/FOYERÀGAZVENTILÉ.
Page1of2
FOYERÀGAZVENTILÉDIRECT.HOMOLOGUEPOURINSTALLATIONDANSUNECHAMBREACOUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SONINSTALLATIONCONFORMEAUXEXIGENCESDELANORMECAN/CSAZ240MHSERIEDEMAISONS
MOBILESEQUIPEESAUGAZ,ENVIGUEURAUCANADAOUAUXETATS-UNISDELANORMEDESECURITE
ETDECONSTRUCTIONDEMAISONSMANUFACTUREES,TITRE24CFR,SECTION3280.DANSLECASOU
CETTENORMED'ETATS-UNISNEPEUTETREAPPLIQUEE,SEREFERERALANORMERELATIVEAU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES
MAISONSMANUFACTURES,LESSITESETLESCOMMUNAUTES,ANSI/NFPA501A.
POUR UNE UTILISER
AVEC BARRIÈRE W565-0228. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DANS LE MANUEL D'INSTALLATION.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCEWITHTHECURRENTSTANDARDCAN/CSAZ240MHSERIESGASEQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USETHE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTUREDHOMEINSTALLATIONS,SITESANDCOMMUNITIES,ANSI/NFPA501A.
FOR
USE WITH BARRIER W565-0228. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE
INSTALLATION MANUAL.
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
0-4500FT(0-1370m) ALTITUDE/ELEVATION 0-4500FT(0-1370m)
22,000 BTU/h INPUT / ALIMENTATION 22,000 BTU/h
17,500BTU/h REDUCEDINPUT/ALIMENTATIONREDUITE 19,000BTU/h
MANIFOLD PRESSURE: 3.5"(9MB)WATERCOLUMN MANIFOLD PRESSURE: 10" (25MB) WATER COLUMN
PRESSION AU COLLECTEUR:3.5"(9MB)D'UNECOLONNED'EAU PRESSION AU COLLECTEUR: 10" (25MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" (11MB) WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" (27MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" (27MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13.0" (32MB) WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13.0" (32MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAU
P4: 65% P4: 65%
NOT FOR USE WITH SOLID FUEL.
FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING:
THISFIREPLACEUSESANDREQUIRESAFASTACTINGTHERMOCOUPLE.REPLACE
ONLYWITHAFASTACTINGTHERMOCOUPLESUPPLIEDBYWOLFSTEELLTD.
DONOTADDANYMATERIALTOTHEAPPLIANCE,WHICHWILLCOMEINCONTACTWITHTHEFLAMES,
OTHERTHANTHATSUPPLIEDBYTHEMANUFACTURERWITHTHEAPPLIANCE.MINIMUMCLEARANCE
TO COMBUSTIBLE MATERIALS /
DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:
TOP/DESSUS 0 RECESSEDDEPTH/PROFONDEURD'ENCASTRE 18"
FLOOR/PLANCHER 0 VENTSIDES/COTESDEL'EVENT 1"
SIDES/COTES 0 VENTTOP/EVENTSUPERIEUR 3"
BACK/ARRIERE 0 VENTBOTTOM/EVENTINFERIEUR 1"
MANTEL / MANTEAU 2" *
*MAXIMUMHORIZONTALEXTENSION/L'EXTENSIONHORIZONTALEMAXIMALE:2".SEEINSTRUCTION
MANUALFORGREATEREXTENSIONS.REFERERAUMANUELD'INSTRUCTIONPOURDES
EXTENSIONSPLUSGRANDES.
SEEOWNER'SINSTRUCTIONMANUALFORMINIMUMANDMAXIMUMVENTLENGTHS.
REFERERAUMANUELD'INSTALLATIONDEPROPRIETAIREPOURLESLONGUEURS
D'EVACUATIONMINIMALEETMAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC
CET APPAREIL.
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CEFOYERUTILISEETREQUIERTUNTHERMOCOUPLEÀACTIONRAPIDE.
REMPLACEZ UNIQUEMENTAVEC UN THERMOCOUPLE ÀACTIONRAPIDE DE WOLFSTEELLTÉE.
N’AJOUTEZPASACETAPPAREILAUCUNMATERIAUDEVANTENTRERENCONTACTAVECLESFLAMMES
AUTREQUECELUIQUIESTFOURNIAVECCETAPPAREILPARLEFABRICANT.
THEAPPLIANCEMUSTBEVENTEDUSINGTHEAPPROPRIATEWOLFSTEELVENTKITS.SEEOWNERS
INSTALLATIONMANUALFORVENTINGSPECIFICS.PROPERREINSTALLATIONANDRESEALINGIS
NECESSARYAFTERSERVICINGTHEVENT-AIRINTAKESYSTEM.
L'APPAREILDOITEVACUERSESGAZENUTILISANTL'ENSEMBLED'EVACUATIONPROPREANAPOLEON.
REFERERAUMANUELD'INSTALLATIONDEPROPRIETAIREPOURL'EVACUATIONPRECISE.ILEST
IMPORTANTDEBIENREINSTALLERETRESCELLERL'EVENTAPRESAVOIRASSURELEMAINTIENDU
SYSTEMEDEPRISED'AIR.
DECORATIVEPRODUCT:NOTFORUSEASAHEATINGAPPLIANCE
PRODUITDÉCORATIF:NEPASUTILISERCOMMEAPPPAREILDECHAUFFAGE.
ELECTRICALRATING/CLASSIFICATION:115V0.82AMP,60HZ
OPTIONALFANKIT/ENSEMBLEDEVENTILATEURFACULTATIF:EP35
SERIAL NUMBER/NO. DE SERIE: B46TR
MATERIAL: .010VELVETMATTELEXANAND/OR.050HI-TEMPPOLYESTER
MIN.LETTERINGFOR"NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI. "TOBE10POINTARIAL,BOLDFACE,
UPPERCASEAND2POINTLEADINGSPACINGOREQUIVALENT.HOLETOBE0.250ӯ.
BLACKONWHITEBACKGROUND
MAXOVERALLDECALSIZE:4.75"x8.50"
HOLEIS0.250”Ø/0.312“FROMBOTTOMANDLEFTEDGE”
SERIALNUMBERSTOBEASCENDINGFROMB46TR 007160
B46NTR CB46NTR MODEL CB46PTR B46PTR
B46NTRE CB46NTRE CB46PTRE B46PTRE
A UPDATED MAX. SUPPLY PRESSURE (NG)
B46(N)TR(E) / B46(P)TR(E)
RATING PLATE W385-2134_A
03.21.18_JK
A
A
W385-2134
JFK