W415-0676 / A / 06.07.10
7
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Your appliance must be installed in accordance with
all national and local building code standards and the
standard of Chimney andAppliances, Vents and Solid
Fuel BurningAppliances NFPA#211. Consult the authority having jurisdiction (such as municipal building
department, fire department, fire prevention bureau, etc.) to determine the need to obtain a permit. If you are in
doubt about the proper installation for your situation, contact your dealer or local building or fire official. The
manufacturer does not guarantee that this appliance and its options will completely heat your entire home.
2.3.1 EPA COMPLIANCE
2.4 RATING PLATE INFORMATION
LISTED FACTORY-BUILT FIREPLACE
TESTED TO: ULC S610, UL127.
REFER TO FIREPLACE AND CHIMNEY MANUFACTURER'S INSTRUCTIONS AND BUILDING CODE FOR SAFE INSTALLATIONAND OPERATION. DO NOT OBSTRUCT COMBUSTION AIR
INLET. OPERATE ONLY WITH VIEWING DOOR CLOSED AND LATCHED. OPERATE ONLY WITH FIREBRICK IN PLACE. MODEL NZ-26 ONLY: SUITABLE FOR INSTALLATION IN AMOBILE
HOME (USA ONLY)
MINIMUM CLEARANCE TO COMBUSTIBLES (BOTH UNITS)
"A": MINIMUM OUTLETAREA (PER CHANNEL) 324SQ CM (50"SQ)
"B": DO NOT BLOCK GRILLS
"C": SIDEWALL 533MM (21")
"D" 305MM (12")
"E" 152MM (6")
NZ-26 ONLY:
FRAMING MATERIALS: TOP, SIDES AND BACK: PER STAND-OFF SPACERS.
FINISHING MATERIALS: SEE INSTALLATION MANUAL.
NZ-26WI ONLY:
FRAMING MATERIALS: BACK: PER STAND-OFF SPACER. TOP & SIDES: SEE INSTALLATION MANUAL.
FINISHING MATERIALS: SEE INSTALLATION MANUAL.
BASE OF UNIT TO CEILING: NZ-26 NZ-26WI
VENTED ENCLOSURE: 1,828MM (72”) 2,133MM (84”)
NON-VENTED ENCLOSURE: 2,133MM (84”) N/A
A 51MM (2") WIDE MANTLE MUSTBE LOCATED MINIMUM 610MM (24") ABOVE FIREPLACE DOOR. (SEE INSTALLATION MANUAL)
CHIMNEY: 51MM (2") (SEE MANUFACTURERS INSTALLATION INSTRUCTIONS)
COMBUSTIBLE MATERIALS MUST NOT BE PLACED ON THE BLACK PAINTED FACE OF THE UNIT.
ADJACENT SIDEWALLMAY BE PLACED AT A45° ANGLE FROM FRONT EDGE OF FIREPLACE.
THIS UNIT MAY BE INSTALLED TO ULC S639, LISTED STEEL LINER ASSEMBLIES FOR SOLID FUEL BURNING MASONRY
FIREPLACES.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY 9.5MM (3/8") MIN. THICK MILLBOARD OR EQUIVALENT TOADISTANCEAT THE
FRONT OF 457MM (18")AND AT THE SIDE OF THE FIREPLACE OPENING OF 203MM (8"}.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT OVERFIRE.
REPLACE GLASS WITH CERAMIC GLASS ONLY.
THIS UNIT NEEDS AIR FOR PROPER OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE
COMBUSTION AND VENTILATION AIR.
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
CAUTION:
A A
C
D
E
CEILING / PLAFOND
S/W / M/L
NZ-26
B
B
CHIMNEY REQUIREMENTS: (SEE INSTALLATION MANUAL)
CHIMNEYMUST BECERTIFIEDTOONE OFTHE FOLLOWING STANDARDS ULCS604,
ULC S610 OR ULC S629 FOR CANADA OR UL 103HT OR UL 127 FOR THE UNITED
STATES.
MASONRY CHIMNEY INSTALLATION:
STAINLESS STEELLINER MUSTBE CERTIFIEDTO ULCS640 ORULC639 FOR CANADA
OR UL 1777 FOR THE UNITED STATES. US ENVIRONMENTAL PROTECTIONAGENCY
CERTIFIED TO COMPLY WITH JULY 1992 PARTICULATE EMISSION STANDARD.
OPTIONAL COMPONENTS:
OUTSIDE AIR KIT: 111KT
FAN KIT: NZ62
THERMOSTATIC COMBUSTIONAIR CONTROL: NZ690KT
CENTRAL HEATING KIT: NZ62CH
HOT AIR GRAVITY VENTS: NZ220
HOTAIR DISTRIBUTION KIT : GA-566
MADE IN CANADA BY
WOLF STEEL LTD BARRIE ONTARIO, CANADA NZ26
SERIAL NO. / NO.DE SERIE:
DATE CODE / DE DATE
W385-0354
A
C
D
E
CEILING / PLAFOND
S/W / M/L
NZ-26WI
B
B
Reference # 15122
AND OPERATION. DO NOT OBSTRUND OPERATION. DO NOT OBSTRU
DEL NZ-26 ONLY: SUITABLE FOR INSTALL
26 ONLY: SUITABLE FOR INSTALL
OVE FIREPLACE DOOR. (SEE INSTALLATIOOVE FIREPLACE DOOR. (SEE INSTALLATIO
PAINTED FACE OF THE UNIT.PAINTED FACE OF TH
RONT EDGE OF FIREPLACE.T EDGE OF FIREPLACE.
EEL LINER ASSEMBLIES FOR SOLID FUER ASSEMBLIES FOR SOLID F
M (3/8") MIN. THICK MILLBOARD OR EQUIVM (3/8") MIN. THICK MILLBOARD OR EQUIV
REPLACE OPENING OF 203MM (8"}.REPLACE OPENING OF 203MM (8"}.
ERATION AND MUST BE INSTALLED SO T
ATION AND MUST BE INSTALLED SO
CHILDREN, CLOTHING,CHILDREN, CLOTHING,
HIMNEY RE
UIREMENT
:
CHIMNEYMUST BECERTIFIEDCHIMNEYMUST BECERTIFIED
ULC S610 OR ULC S629 FOC S610 OR ULC S629 FO
TATE
.
MASONRY CHIMNEY INMASONRY CHIMNEY I
STAINLESS STEELLSTAINLESS STEEL
OR UL 1777 FOROR UL 1777 FOR
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.