Nausem 462069 User manual

Instructions for Use
Nausem
REF 462069

- 2 -

- 3 -
Contents
What is Nausem capable of?..........................................................4
How to use Nausem safely.............................................................5
Who is not allowed to use Nausem or only after consulting their
doctor?............................................................................................5
Description of Nausem....................................................................5
Inserting the battery........................................................................6
Where do I apply the Nausem? ......................................................6
How do I use Nausem?...................................................................7
What side effects might occur?.......................................................8
What items come supplied with the Nausem?................................8
Technical specifications of the Nausem .........................................9
Description of symbols found on nameplate.................................10

- 4 -
Dear Customer!
We sincerely appreciate your purchase of this Nausem. These
Instructions for Use are designed to assist you in learning about
how to use the device.
What is Nausem capable of?
Nausem enables you to enjoy carefree travelling by air, sea or
road.
Nausem has been developed for those people who suffer from
nausea, dizziness or vomiting.
Medicine designed to treat nausea and vomiting can produce side
effects such as drowsiness or giddiness. Nausem is a gentler
alternative that can be used as a sole means of therapy or in
combination with medicine.
The treatment involves stimulating the skin (transcutaneous
stimulation) with the help of electrodes. As Nausem is simple to
use, you determine the length and intensity of application. Since
Nausem can be used at any time, you do not need to begin your
treatment hours in advance.
However, should you be prone to travel sickness, attach Nausem
around half an hour before departure and allow the timer to run for
approx. 15 minutes.
Nausem is not a substitute for consulting your doctor. Nausea
and vomiting are serious physical reactions. Should the
symptoms prevail, please ensure that you consult your doc-
tor.

- 5 -
1
2
3
7
45
6
How to use Nausem safely
Before using Nausem, please read these instructions for use
carefully!
•Nausem is only to be used with the original accessories.
•Keep Nausem away from water and other liquids.
•Never use Nausem when it is not functioning correctly or has
been damaged.
•Only use Nausem on the area of the wrist described below.
Who is not allowed to use Nausem or only after
consulting their doctor?
•People with electronic implants
•People suffering from heart rhythm disturbances (arrhythmia)
•People suffering from seizure disorders
•People with skin diseases where the electrodes need to be
applied
•People whose nausea and vomiting have not been sufficiently
diagnosed
•People undergoing pregnancy
Description of Nausem
1 Display for “Programme 1”
2 Programme key (MODE)
3 Display for “Programme 2”
4 Key for lowering intensity/
OFF key (LO/OFF)
5 ON key/Key for increasing
intensity (ON/HI)
6 Battery compartment
7 Electrode

- 6 -
Inserting the battery
Apply a little thumb pressure to the battery compartment, open it in
the direction of the arrow and insert the supplied 3 volt lithium
battery into the Nausem as shown in the illustration on the inside
of the battery compartment lid.
Always switch off the Nausem before changing the battery.
Please remove the lithium battery if the Nausem is not going to be
used for a length of time.
Where do I apply the Nausem?
Before use, please wash the area of skin where the device is to be
applied to ensure that the electrodes cling well.
Connect the Nausem to the electrodes by
means of the stud adapter or the con-
nector. Remove the protective foil from
the elctrodes. Place the Nausem about
two to three fingers width away from the
bend in the wrist (see illustration).
Apply the smaller electrode opposite the
larger one on the underside of the forearm
(see illustration).
Caution!
If only one of the electrodes is applied to
the skin, you will not be able to increase
the intensity and the Nausem will automatically switch off after
about 20 seconds.
Should the position of the electrode be changed during treatment,
the intensity will automatically re-set to the lowest level.

- 7 -
After treatment, please place both electrodes back onto the pro-
tective foil. The electrodes will last longest if stored in a cool place
(a fridge, for example). Adding a few drops of water to the surface
will restore the adhesiveness of the electrodes.
How do I use Nausem?
To switch on and increase the intensity, press the ON/HI key (5).
The level of intensity increases each time you press the key (max.
of 10 levels). The greater the intensity, the “more noticeable” the
current.
To switch off and lower the intensity, press the LO/OFF key (4).
The level of intensity decreases by one level each time you press
the key and the Nausem will switch itself off after level 1.
To select the desired programme, press the MODE key (2). Press
the key to switch between programmes 1 and 2. The selected
programme is shown in display 1or 3. If no level of intensity is
subsequently selected, the Nausem will automatically switch off
after about 20 seconds.
If the Nausem is switched off and then back on again later, the last
programme that was used will be displayed.
After the programme has been changed, the level of intensity will
automatically be reset to the lowest level. Should you wish to
switch off the Nausem during treatment, please press the MODE
key (2) first to allow the level of intensity to re-set automatically to
the lowest level. Once this has occurred, switch off the Nausem by
pressing the LO/OFF key (4).
The Nausem has an automatic timer function. The length of
treatment is approx. 15 minutes after which the Nausem will
automatically switch off. A flashing light in display 1or 3indicates
that the timer function is on. Should the programme be changed
during treatment, the timer will continue to run and will not re-start
at 15 minutes.
When using the Nausem for the first time, you will find that the
default setting is low-frequency stimulation (Programme 1).

- 8 -
Should this not be enough to reduce the nausea, simply press the
MODE key (2) to switch to high-frequency stimulation (Pro-
gramme 2).
What side effects might occur?
Skin irritation
Skin irritation may arise in reaction to the electrodes, the conduc-
tivity gel or the electrical impulses themselves. Should the redness,
burning, itchiness or blisters under the electrodes or in the region
where the electrodes are applied prevail after treatment, please
ensure that you consult your doctor before undergoing any further
treatment.
Slight, temporary reddening of the skin in the areas where the
electrodes have been applied is a normal occurrence after treat-
ment and is an indication of improved blood circulation caused by
the stimulation.
What items come supplied with the Nausem?
Qty. Item Art. No.
1 Nausem 462069
1 Electrode set
(1 x 50 mm round and 1 x 32 mm
round electrode)
451070-0027
1 3 volt lithium battery (type CR2032) 450780-0014
1 Case 450980-0103
1 Instructions for use 451600-0253
We will gladly send you any consumable materials and spare parts
upon request. To do so, please ensure that you quote the relevant
article number.

- 9 -
Technical specifications of the Nausem
The Nausem is a 1-channel electrical stimulation device with two
integrated programmes. It has been designed to provide transcu-
taneous electrical nerve stimulation (TENS) on people.
Output voltage with 80 VSS ±20 %, adjustable to 10 levels
a load of 500 Ω
Range of frequency 7 Hz (Programme 1)
25 Hz (Programme 2)
Pulse width 150 µs (Programme 1)
90 µs (Programme 2)
Pulse type positive square pulse
Current consumption max. 64 mA
Power supply 3 volt lithium battery (type CR2032)
Timer approx. 15 minutes
Dimensions approx. 61 mm x 35 mm x 8 mm
Weight approx. 17 g (incl. lithium battery)

- 10 -
Description of symbols found on nameplate
Caution. Accompanying documents must be ob-
served!
Type BF device. The product ensures protection
against electric shocks provided that a permissible
leakage current is used.
This symbol precedes the year the product was
manufactured.
REF This symbol precedes the article or order number for
the product.
SN This symbol precedes the serial number of the
product.
This product bears the recycling symbol pursuant to
EU Directive 2002/96/EC. This means that the
product must be taken to a municipal recycling depot
at the end of its useful life to be disposed of free of
charge. The product may not be disposed of as
household/residual waste. This represents an active
contribution to conserving the environment.
|0197 Certificate of Conformity in keeping with the Council
Directive 93/42/EEC of 14 June 1993 governing
medical devices.

- 11 -
Notes

|0197
Manufacturer:
Pierenkemper GmbH
Hörnsheimer Eck 19 •35578 Wetzlar •Germany
+49 6441 67923-0
+49 6441 67923-33
www.pieren-tech.de
451600-0253
Version 1
Table of contents
Popular Medical Equipment manuals by other brands

Caldera
Caldera Benesta CAL-TR1511 Instructions for use

biodex
biodex 058-840 Unpacking Instructions and Assembly

Lowenstein Medical
Lowenstein Medical CARA Full Face Instructions for use

Easylife
Easylife PANTONE 072 C instruction manual

ROHO
ROHO HARMONY Operation manual

Obtura
Obtura III MAX Operator's manual

LINET
LINET Air2Care 10 Instructions for use

BMC
BMC G2S A20 Quick operation manual

Acutronic Medical Systems
Acutronic Medical Systems fabian HFO quick guide

Somnetics
Somnetics Transcend Sleep Apnea Therapy user manual

GE
GE Datex-Ohmeda Aisys Carestation Reference manual

Drive DeVilbiss Healthcare
Drive DeVilbiss Healthcare CHAD CH4808-L-BLUE PRODUCT INFORMATION AND INSTRUCTIONS