Necto Group 2AMDI511IPVRDS User manual

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
USER MANUAL 2AMDI511IPVRDS
SUBJECT INDEX:
DESCRIPTION
TECHNICAL SPECIFICATION
DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE
OPERATION MODES
LINEAR POTENTIOMETER MODE 100KOHM
MODE 0-10V/1-10V PASSIVE
PUSH MODE
DALI MODE
PARAMETERS CONFIGURATION
pag|1

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
CONTROL INPUTS
DALI
0-10V;1-10V PUSH NO
(INSULATED) LINEAR POTENTIOMETER
X1 X1
X1 X1
MAX OUTPUT CURRENT*
da 170mA a 1050mA
TECHNICAL NOTES
- Mono channel Dimmers with Output Current PWM.
- Input Range: 8-53V DC.
- Output Current PWM with current from 170mA a 1050mA
(54.6W at 52V DC).
- Input Controls: Insulated Push button x1, DALI x1,
Linear Potentiometer 100K x1, 0-10V Passive x1,
1-10V Passive x1.
- Printed Circuit UL.
- Protection Class: IP20.
- Standard Dimension 40x80x24.45 mm.
- Dimension with accessories 40x100x24.45 mm.
- Reverse polarity protection.
- Open circuit protection.
- Surge voltage protection.
- Over temperature protection.
- Short circuit protection.
PULSANTE N/O ISOLATO
DIMMER MONOCANALE MULTIPROTOCOLLO COSTANT CURRENT
2AMDI511IPVRDS
NO isulated switch
Mono channel Dimmers with Output Current PWM. Input Range: 8-53V DC.
Output Current PWM with current from 170mA a 1050mA (54.6W at 52V
DC). In order to set the output current you will need the 2AMIN4030000N
interface sold separately. Default current 350mA. In order to set the fade
output and the logarithmic or linear output you will need the 2AMIN4030000N
interface sold separately, the other working modes are automatically
detected by the device. Please refer to user manual.
pag|2

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
CODE INPUT
VOLTAGE
(MAX) OUTPUT
CURRENT
n. OUTPUT
CHANNELS
MAX OUTPUT
POWER CONTROL INPUTS CASE DIM.
2AMDI511IPVRDS 8-53V DC DA 170mA
A 1050mA 154.6W A 52V DC
INSULATED PUSH BUTTON X1
DALI X1
LINEAR POTENTIOMETER
100K X1
0-10V PASSIVE X1
1-10V PASSIVE X1
YES 40X80 mm
h 24,45 mm
pag|3

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
POWER SUPPLY CONNECTION DIAGRAM AND LED 2AMDI511IPVRDS - FIGURE N. 1
The 2AMDI511IPVRDS dimmer has to be powered according to the polarity showed in FIG. 1
through the DC IN (+ and -) terminals.
In case the power supply polarity is inverted no damage will be caused to the device .
The LED (LED PWR) positioned on the circuit board indicates the presence of power supply.
The LED (LED DIM) shows the dimming level of the output.
The LED load connection has to be made by using the OUT (L+ and L-) terminals.
DEVICE POWER SUPPLY AND CONNECTION
TO THE LED MODULE
pag|4

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
POTENTIOMETER WIRING 2AMDI511IPVRDS - FIGURE N. 2
In order to activate this mode of control/operation just connect a linear potentiometer of 100 Kohm between the D+
and D- inputs and disconnect the remaining inputs.
By default, the dimming curve follows a logarithmic trend proportional to the resistance value set by the
potentiometer.
A resistance value of less than 5 Kohm is interpreted as load off.
The maximum brightness value is reached by exceeding the value of 95 Kohm.
In case the potentiometer is disconnected, the dimmer sets the output to the saved level (see preset level
change).
The preset value is zero by default.
On the rst run in this mode it could be necessary to set the input to a value greater than 50% (55K or higher on DD
+ input) in order to congure the dimmer to the potentiometer mode.
*This setting can be congured through the interface cod. 2AMIN4030000N
OPERATION MODES
LINEAR POTENTIOMETER MODE 100KOHM
pag|5

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
WIRING 0-10V 2AMDI511IPVRDS - FIGURE N. 3
In order to activate this mode of control/operation just connect the active control signal of 0-10V/1-10V between
the D+ and D- inputs (being careful to observe the correct polarity) and disconnect the remaining control signals.
The maximum current absorbed by 0-10V dimmer interface is 0,1 mA.
By default, the dimming curve follows a logarithmic trend proportional to the control voltage. A voltage value of less
than 1V is interpreted as load off.
In case the 0-10V/1-10V signal is disconnected, the dimmer sets the output to the saved level (see preset level
change). The preset value is zero by default.
On the rst run in this mode it could be necessary to set the input to a value greater than 50% (5V or higher on DD
+ input) in order to congure the dimmer to the 0-10V/1-10V mode.
*This setting can be congured through the interface cod. 2AMIN4030000N
MODE 0-10V/1-10V PASSIVE
pag|6

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
WIRING BUTTON 2AMDI511IPVRDS - FIGURE N. 4
In order to activate this mode of control/operation it is necessary to remove any control signals from the D + and Dinputs
and connect between the DALI/P1 and DALI/P2 inputs, a signal in direct or alternating voltage
(DC voltage range:10÷265V, AC 12÷265Vac 50÷65Hz) interrupted by a normally open button (N.O.).
No polarization is needed for the input signal.
The maximum current absorbed by the PUSH interface is about 2mA.
The dimmer saves the output position in order to restore the set level in case of power failure (preset).
PUSH interface operation
Single Click (rapid press (<1sec))
- Turns on or off the output (ON/OFF).
Double Click (rapid press (<1sec))
- Sets maximum brightness (output= 100%)
Long Press (long press (>1sec))
- If the dimmer is in OFF position, it sets the output to the minimum value (default= 1%)
- If the dimmer is in ON position, the long press enables the output dimming (up/down).
PUSH MODE
pag|7

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
DALI 2AMDI511IPVRDS WIRING - FIGURE N. 5
In order to activate this mode of control/operation it is necessary to shortcircuit the D+ and D- inputs and connect
the DALI bus between the DALI/P1 and DALI/P2 inputs.
On the rst reception of a properly formatted DALI package the dimmer is congured in DALI mode. Once
congured in DALI mode and disconnected from the DALI bus the dimmer switches to the POWER ON LEVEL
mode set through DALI bus.
The maximum current absorbed by the DALI bus is about 2mA.
Below you can nd the implemented standard commands:
DIRECT ARC POWER
OFF
UP
DOWN
STEP UP
STEP DOWN
RECALL MAX LEVEL
RECALL MIN LEVEL
STEP DOWN AND OFF
ON AND STEP UP
GO TO SCENE (0-15)
RESET
STORE ACTUAL LEVEL IN THE DTR
STORE THE DTR AS MAX LEVEL
STORE THE DTR AS MIN LEVEL
STORE THE DTR AS SYSTEM FAILURE LEVEL
STORE THE DTR AS POWER ON LEVEL
STORE THE DTR AS FADE TIME
STORE THE DTR AS FADE RATE
STORE THE DTR AS SCENE (0-15)
REMOVE FROM SCENE (0-15)
ADD TO GROUP (0-15)
REMOVE FROM GROUP (0-15)
STORE DTR AS SHORT ADDRESS
DALI MODE
pag|8

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
QUERY STATUS
QUERY BALLAST
QUERY LAMP POWER ON
QUERY LIMIT ERROR
QUERY RESET STATE
QUERY MISSING SHORT ADDRESS
QUERY VERSION NUMBER
QUERY DEVICE TYPE
QUERY PHISICAL MINIMUM LEVEL
QUERY POWER FAILURE
QUERY CONTENT DTR1
QUERY CONTENT DTR2
QUERY ACTUAL LEVEL
QUERY MAX LEVEL
QUERY MIN LEVEL
QUERY POWER ON LEVEL
QUERY SYSTEM FAILURE LEVEL
QUERY FADE TIME/FADE RATE
QUERY SCENE LEVEL (0-15)
QUERY GROUPS (0-7)
QUERY GROUPS (8-15)
QUERY RANDOM ADDRESS H
QUERY RANDOM ADDRESS M
QUERY RANDOM ADDRESS L
pag|9

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
PARAMETERS CONFIGURATION
CLICK ON THE WANTED CONFIGURATION TO VIEW 2AMIN4030000N
PROGRAMMER IMAGE
Reset
Configuration A B C D 1 2 3 4 5 6 7 8 9 10
Reset ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Dimming Curve
Configuration A B C D 1 2 3 4 5 6 7 8 9 10
Logarithmic OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
Linear OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
PWM
Configuration A B C D 1 2 3 4 5 6 7 8 9 10
PWM Standard OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
PWM Inverted OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
Fade
Configuration A B C D 1 2 3 4 5 6 7 8 9 10
Fade Off OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
Fade On OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
Current
Configuration A B C D 1 2 3 4 5 6 7 8 9 10
170 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
182 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
195 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
210 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON
222 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF
235 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON
250 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF
260 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON
270 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
290 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON
300 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF
315 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON
330 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF
345 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON
355 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF
370 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON
385 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF
395 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON
410 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF
425 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON
438 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF
450 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON
465 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF
480 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON ON
490 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF
500 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON
pag|10

USER MANUAL 2AMDI511IPVRDS
www.nectogroup.com
515 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF
530 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON
545 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF
560 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF ON
575 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON OFF
585 mA OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON
600 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
615 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON
626 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON OFF
640 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON ON
653 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF
667 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF ON
680 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON OFF
694 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON
707 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF
721 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON
734 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF
748 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON
761 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF OFF
775 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF ON
788 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON OFF
802 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON ON
815 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF
829 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF ON
840 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON OFF
855 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON ON
870 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF OFF
880 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF ON
895 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF
910 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON ON
920 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF OFF
935 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON
950 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON OFF
965 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON ON
975 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF OFF
990 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF ON
1020 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON OFF
1050 mA OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON
pag|11
This manual suits for next models
1
Table of contents
Other Necto Group Dimmer manuals
Popular Dimmer manuals by other brands

American DJ
American DJ DP-DMX4B User instructions

Jands
Jands HUB 24 operating manual

Lutron Electronics
Lutron Electronics Maestro Wireless MRF2-600M Quick start quide

NSI
NSI DS12 Installation and operation guide

Lightronics
Lightronics AT SERIES owner's manual

INSTEON
INSTEON SwitchLinc 2478D quick start guide