NEIL PREMIUM 700 Technical specifications

CONTACT INFORMATION
0800-222-0177 vent[email protected]om.ar www.neil.com.ar
USE AND INSTALLATION MANUAL

USER MANUAL - PREMIUM 700
CONTENTS
DECLARATION OF CONFORMITY. . . . . . . . . . . . . . . . 2
UPDATED DIGITAL CONTENT . . . . . . . . . . . . . . . . . . . 3
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TECHNICAL INFORMATION . . . . . . . . . . . . . . . . . . . . .5
EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
INSTALLATION SEQUENCE . . . . . . . . . . . . . . . . . . . . . .6
PREVENTIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . 10
SOLUTIONS FOR LOW-PERFORMANCES . . . . . . . . . 11
F.A.Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
WATER TANK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
EXTERNAL MEASUREMENTS. . . . . . . . . . . . . . . . . . . . 13
DEVICE FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

USER MANUAL - PREMIUM 700
DECLARACIÓN DE CONFORMIDAD
COMFORT SDN S.A., con domicilio social en Av. Bicentenario N° 459, Merlo, Buenos
Aires, Argentina, como fabricante de equipos enfriadores evaporativos para
vehículos marca Neil.
DECLARA: Que los equipos diseñados y fabricados por COMFORT SDN S.A. bajo las
especificaciones técnicas necesarias, una vez instalados en los vehículos, de
acuerdo a las instrucciones de montaje que lo acompañan , cumplen con las
directivas Europeas de nuevo enfoque sobre:
a) Compatibilidad Electromagnética: 72/245/CEE , 2006/28/CE
b) Bajo Voltaje: 72/23 EEC
c) Otros: 2011/65/EU
Que garantizan la seguridad de personas y bienes durante su instalación y
funcionamiento.
Buenos Aires, febrero de 2020
Lic. Neil Sebastian
Presidente Comfort SDN S.A.
DECLARATION OF CONFORMITY
COMFORT SDN S.A., with registered office at Av. Bicentenario N ° 459, Merlo,
Buenos Aires, Argentina, as a manufacturer of Neil brand evaporative cooling
equipment for vehicles.
DECLARES: That the equipment designed and manufactured by COMFORT SDN
S.A. under the necessary technical specifications, once installed in the vehicles,
according to the accompanying assembly instructions, they comply with the new
approach European directives on:´
a) Electromagnetic compatibility: 72/245/CEE , 2006/28/CE
b) Low voltage: 72/23 EEC
c) Others: 2011/65/EU
They guarantee the safety of people and goods during their installation and
operation.
Buenos Aires, February 2020
Lic. Neil Sebastian
Presidente Comfort SDN S.A.
DICHIARAZIONE DI CONFORMITÀ
COMFORT SDN S.A., con sede legale in Av. Bicentenario N ° 459, Merlo, Buenos
Aires, Argentina, come produttore di apparecchiature di raffreddamento evapora-
tivo a marchio Neil per veicoli.
DICHIARA: Che l'apparecchiatura progettata e prodotta da COMFORT SDN S.A.
secondo le specifiche tecniche necessarie, una volta installati sui veicoli, secondo le
istruzioni di montaggio allegate, si conformano al nuovo approccio delle direttive
europee su:
a) Compatibilità elettromagnetica: 72/245/CEE , 2006/28/CE
b) Basso voltaggio: 72/23 EEC
C) Altri: 2011/65/EU
Garantiscono la sicurezza di persone e merci durante l'installazione e il
funzionamento.
Buenos Aires, Febbraio 2020
Lic. Neil Sebastian
Presidente Comfort SDN S.A.
DECLARAÇÃO DE CONFORMIDADE
COMFORT SDN S.A., com sede na Av. Bicentenario N ° 459, Merlo, Buenos Aires,
Argentina, como fabricante de equipamentos de refrigeração por evaporação para
veículos da marca Neil.
DECLARA: Que o equipamento projetado e fabricado pela COMFORT SDN S.A. de
acordo com as especificações técnicas necessárias, uma vez instaladas nos
veículos, de acordo com as instruções de montagem que as acompanham,
cumprem a nova abordagem das diretivas européias sobre:
a) Compatibilidade eletromagnética: 72/245/CEE , 2006/28/CE
b) Baixa voltagem: 72/23 EEC
c) Outras: 2011/65/EU
Eles garantem a segurança de pessoas e mercadorias durante sua instalação e
operação.
Buenos Aires, febrero de 2020
Lic. Neil Sebastian
Presidente Comfort SDN S.A.
2

USER MANUAL - PREMIUM 700
UPDATED DIGITAL CONTENT
Visit our website and find all the updated information about the installation and
maintenance of your Neil Evaporative Cooler.
https://neil.com.ar/en/technical-support/
You can find tutorial
videos about how you
can install the Evaporati-
ve Cooler in our website:
Access the maintenance
section in the website to
diagnose and fix any
technical problem:
Download the last ver-
sion of the manual in the
following link:
You can also find technical information about
our products in other languages
Spanish Italiano Français Português Deutsche
neil.com.ar neil.com.ar/it neil.com.ar/fr neil.com.ar/po neil.com.ar/ge
3

USER MANUAL - PREMIUM 700
WARRANTY
COMFORT SDN S.A., guarantees the devices in case of verified faulty materials or
manufacture of our Evaporative Coolers
COMFORT SDN S.A., will repair or replace based on its own technical criteria, the
faulty components or parts.
This warranty does not include the intentional or accidental damages caused by
inappropriate or incorrect use, and/or by modifications in the installation instruc-
tions and/or by changes in the specific materials of the product, and/or by any
other cause that is not attributable to the materials quality and/or manufacture
defect mentioned. As water pumps durability depend on the previous maintenan-
ce made by the user (periodic cleaning of the Evaporative Cooler) they are not co-
vered by the warranty.
Expenses outside the factory building by labor, shipping, packaging, transport or
products insurance and/or its parts to repair or replace by COMFORT SDN S.A., will
be charged to the customer.
This warranty expires automatically 2 (two) years after the purchase.
CUSTOMER NAME:
SERIAL NUMBER OF THE EVAPORATIVE COOLER:
INSTALLATION DATE:
INSTALLED VEHICLE:
SELLER/INSTALLER:
KEEP THIS MANUAL TO MAINTAIN YOUR WARRANTY COVERAGE.
The warranty must be validated by the seller and/or the customer
in the following link: neil.com.ar/en/warranty/
SERIAL NUMBER
4

USER MANUAL - PREMIUM 700
5
Maximum power consumption using 24 volts
Maximum power consumption using 12 volts
Maximum air ow
Approx. Refrigeration capacity
Package dimensions and weight
Water tank
Water consumption
4 AMPS
7 AMPS
700 m3/h
1000 to 6000 BTU/h
95 x 72 x 23 cm - 18Kg
80 x 20 x 12 cm - 16 litros
between 1 and 3 Liters/hour
TECHNICAL INFORMATION
The water tank can be
placed both horizontally
and vertically
The water tank can be
placed both horizontally
and vertically
Barrales telescópicos
Fuse holder and fuse
Negative black
cable (thick)
Positive red
cable (thick)
+
Negative black
cable (thin)
Internal frame
xing screws
External pump
(depending on the model)
(depending on the model)
Cover
Filter holder
basket
Condensate
pump
Evaporator
lter
Universal
base
Control
panel
Telescopic
bars
Internal
frame
Water load 16 litres
Battery

USER MANUAL - PREMIUM 700
INSTALLATION SEQUENCE
PREPARING THE VEHICLE ROOF
A- ROOFS WITHOUT SUNROOFS:
When a choice is possible on where to perforate the roof, it is recommended to do
it on the driver seat line, as air distribution is optimal here. (IT IS ALWAYS MORE
EFFECTIVE TO GET COOL AIR FROM THE FRONT).
After defining the best spot, perforate a hole of 430 mm x 310 mm, forming the
radius with 30 mm radius. Then bend the metal upwards to give rigidity. (Approxi-
mately height 10mm all around the perimeter).
Put the weatherstrip all around the rectangular hole of 500 mm x 350 mm, taking
care that the upper surface be in a horizontal plane to obtain the right sustain of
the base of the Evaporative Cooler and prevent water and air from getting into the
cabin.
In case of a roof with gutters, they must be filled with a rubber or thin weatherstrip.
Once the roof is leveled, the self-adhesive
Place the neutral siliconized sealant on the weatherstrip and in the internal
perimeter
You can find tutorial videos about how to correctly cut
the roof and also download the “roof cutting template”
in the following link:
https://neil.com.ar/en/installation-tutorials/
6
NO YES
ROOF PANEL WEATHERSTRIP
INCORRECT CORRECT

USER MANUAL - PREMIUM 700
Set the device in the hole, center it and adjust the telescopic support bars as shown
in the following image:
The 4 stud screw must be adjusted in a cross and even way until making sure the
weatherstrip starts being pressed against the base, preventing water and air from
entering.
ADJUST THE DEVICE TO THE ROOF
B- ROOF WITH SUNROOF:
- Remove the sunroof
- If the sunroof frame doesn’t have a weatherstrip, put one all around the peri-
meter to obtain the correct support for the device base.
- Put neutral siliconized sealant on the weatherstrip before placing the device.
UNIVERSAL TELESCOPIC SUPPORT BARS
PARTS OF EACH ROD
You can find tutorial videos about how to correctly
adjust the Neil Evaporative Cooler in the following link:
https://neil.com.ar/en/installation-tutorials/
7

USER MANUAL - PREMIUM 700
With the Evaporative Cooler firmly adjusted to the roof, the electrical and hydraulic
conexion between the device and the installation hose can be made (only in inter-
nal installation of the water tank). Then put the internal frame and adjust the
screws until it is firmly seated.
FRAME AND CONTROL PANEL SETUP
The Evaporative Cooler must NOT be installed with a negative tilt
IF NEEDED THE DEVICE CAN BE INSTALLED WITH THE FRONT PART
FACING THE BACK OF THE VEHICLE
8
Correct up to 22 degree tilt
Acceptable
Incorrect
YES YES
NO NO
Internal Frame
Frente del vehículo
Tornillos de jación
del Marco Interior
Hoses must present smooth curves in order to avoid a pinched hose on high tem-
perature days. When adjusting the seals be careful not to block the water flow.
Weatherstrip
Telescopic
support bars Washer,
nut and locknut
Control panel
Fixing screws
of the internal frame
The 4 screws must be adjusted in a cross
way and must be even, until making sure
the weatherstrip starts being pressed against
the base preventing water and air from entering.
Front of the vehicle
Screws

USER MANUAL - PREMIUM 700
The pre-cooling system admits any water tank placed in any part of the vehicle
(below the level of the Evaporative Cooler in any position (horizontally or vertica-
lly)).
WATER TANK
INSTALLATION WITH INTERNAL HOSE
9
WATER TANK SETUP
The Neil water tank is held with 3 M6
screws, in case of needing to perforate
the sheet metal to set them, M6 rivet
nuts are included in the installation kit.
The rivet nuts must be put in a 9mm
perforation, which it is recommended
to make them in the sheet metal
strengthening ribs in order to
guarantee stability. Depending on the
model, an additional metallic structure
can be sent to you. This is bolted to the
water tank and it offers ultimate
versatility to set the water tank
vertically or horizontally.
.
!!
A!!
0B! !
/! /!
))$(
/$:!9!/<!!9!!, .!
(";!9!/<( *
/!!/<9!//!?+
/!!/<19!! :/ ,/+
#%# ;# '%'%
@
@
%#01
B%#
B2#2C=&#
-%#
#,!
D
&%233&1
#%#=3#
"3##
# $%
$@%
'%% "
:
% :C% '#&'
'$'9%
1;&
.;&
;&
3/<,!
!>+
//;
!8: /
!(,
*+
3.!"
4#.
&53.
!6#7
/<,!!
/@+19!;/
/!//</+
/'*+(
(-),)$(
WATER PUMP SETUP
If you received the water pump connected to a screw cap, your Evaporative
Cooler has brushless pumps. Remember that the water pump must ALWAYS be
placed in the screw cap under the water to operate properly.
B%#
9 mm
diameter holes
FLAT WASHER
SCREWS
RIVET NUTS
EXTERNAL PUMP
PLACEMENT

Every 300 hours of use (3 months) it is recommended to do the following mainte-
nance procedure:
1- Remove the white cover, taking out screws on the sides.
2- Remove the front sensors. In case of sulfated sensors they must be cleaned
with a fine sandpaper.
3 - Remove the filter holder basket, taking out the screws that are located to
its left and right.
4- Remove the damp filter and clean it with plenty of water
5- The irrigation tube placed in the filter holder basket must have all its holes
unblocked. Compressed air can be used to remove any obstruction.
6- Check the functioning of the condensate pump as follows:
a. Turn on the device with the fan at its minimum speed.
b . Activate the pre-cooling system (Button 10).
c . When the condensate pump is working, the quantity of water that comes
out of the irrigation tube must be able to fill an equivalent of a cup of coffee
(100 ml).
d . If the water volume is less than 100 ml, replace the condensate pump for a
new one of equal voltage.
7- Reassemble all the pieces in their original place.
PREVENTIVE MAINTENANCE
BEFORE TURNING OFF THE DEVICE AND KEEP IT WITHOUT
USING IT FOR A LONG TIME, IT IS RECOMMENDED TO
LET IT WORK FOR 3 HOURS WITHOUT THE PRE-COOLING SYSTEM IN ORDER
TO DRY THE FILTER AND AVOID UNPLEASANT ODOURS.
USER MANUAL - PREMIUM 700
Detailed information about your Evaporative Cooler
maintenance can be found in the following link:
https://neil.com.ar/en/maintenance/
10

1- ELECTRONIC BOARD
Make sure that the pre-cooling button “10”
(see page 14) is activated, and that there is
not a blinking light (lack of water). If the
button “10” (see page 14) is blinking and the
water tank still has water left, check the
water pump and the water hose.
2- WATER PUMP
Make sure that the water tank pump is not
burned or that its turbin is not loose (it can
make noise and still not pump water). Also
control that the electrical connection is not
sulfated.
3- WATER HOSE
Make sure that the hose is not pinched or
blocked.
4- CONDENSATE PUMP
Make sure that the condensate pump is not
burned or that the turbine is not loose. Con-
trol that the irrigation tube has all its holes
unblocked and that the filter is damp along
its length.
5- DIRECT AUTOMATIC SYSTEM
If the previous 4 items are checked and the
Evaporative Cooler is still not working co-
rrectly (can’t cool the air as usual) program
the electronic board in direct automatic
system mode, so the device will keep coo-
ling elementally until checked by the techni-
cal service of the NEIL EVAPORATIVE COO-
LERS. (See “Electronic board”).
¿WHAT TO DO WHEN THE NEIL EVAPORATIVE
COOLER LOWERS ITS PERFORMANCE?
Detailed information about how to fix performance
problems of the Evaporative Cooler can be found in the
following link:
https://neil.com.ar/en/maintenance/
Basic components and operation Check-List
Irrigation Tube
Condensate
Pump
Sensor Sensor
Pre-cooling Chamber
(COLD WATER)
Water Tank
(Higher temperature than the ambient temperature)
Water will fill the pre-cooling
chamber as it runs
out of water
Evaporative Filter
Water
Pump
USER MANUAL - PREMIUM 700
11

USER MANUAL - PREMIUM 700
How much does an Evaporative Cooler cool?
The performance of an Evaporative Cooler
depends on the ambient temperature and the
relative humidity. There is a table in our website
with information about the relationship
between the outlet air temperature from the
device, the humidity and the ambient tempera-
ture
https://neil.com.ar/en/how-does-it-work/
Does an Evaporative Cooler cool as an air con-
ditioner?
The air conditioner only cools with the vehicle
engine running or with a generator set. This
causes:
- Higher fuel consumption by losing power
when moving.
- Environmental contamination by com-
bustion gases coming from the exhaust.
- Disturbing noises from the engine or the
generator set.
- It is not recommended to let the engine
regulate the air conditioner while running as
this can cause premature wear.
The Evaporative Cooler works in both running
and parked vehicles. Its operation is only elec-
trical and consumes only water.
How many degrees can it cool down?
Evaporative Coolers work as they evaporate
water. The temperature decrease depends on
the climate (at a higher temperature and a
lower humidity, the cooling is greater). It can
decrease on average 10°C in warm climates and
relatively humid; and 20°C in warm but dry
climates.
Can I regulate the temperature?
In an air conditioner one can regulate the tem-
perature. In an evaporative cooler the outlet air
temperature depends on the climate condi-
tions.
Does it work in hot climates?
As a general rule, at a higher ambient tempera-
ture the humidity is lower so the evaporative
coolers will have a higher water evaporation
capacity and the cooling will be greater. 2200
BTU are estimated per liter evaporated per
hour.
F.A.Q.
Is it more productive if I put ice in the water?
In the case of the NEIL Evaporative Cooler,
thanks to its pre-cooling system (patented),
the water temperature doesn’t affect the
outlet air temperature, and it is not necessary
to add ice to the water to lower the tempera-
ture (as in other coolers).
Does it moisturize the air?
Absolutely NOT. The cooling process is produ-
ced thanks to the moisture absorption capaci-
ty of the external air. This process takes place
inside the Evaporative Cooler, when the air is
ejected by the nozzles, it starts losing humidity
as it moves away from them, this leads to a
normal humidity rate inside the vehicle. Accor-
ding to research studies, high welfare condi-
tions, performance and attention in human
beings are given between 18°C and 27°C with
ambient relative humidity between 40% and
60%; these conditions are given by the NEIL
Evaporative Coolers.
Can I use air fresheners or scents in the water?
We only recommend using 3 drops of bleach
per liter of water.
Can I use a 220v to 12v converter as a power
source?
Yes, this must provide at least 10 amps for 12
volts and 5 amps for 24 volts.
Can 12 volts devices be installed in a 24 volts
vehicle battery?
No, because this leads to an imbalance in the
battery charge.
Does the Evaporative Cooler start cooling as
soon as it is turned on?
The device will take a time to cool until the
evaporative filter is totally damp.
Can I use it with the moving vehicle?
Yes, the Evaporative Cooler can be used both
in moving and parked vehicles.
12

USER MANUAL - PREMIUM 700
Depending on the device model, the water tank can include support bars to help install it in
different positions.
It is recommended to use supplements in case of necessity to obtain a firmly placed water tank.
WATER TANK IN UTILITY VEHICLES AND PICK-UP TRUCKS
13
IMPORTANT:
- The water tank should be set up at least 1 meter below the device level
- Once the water tank is settled, it is important to have an easy access to reload it with
water
The following placements are shown as merely guidance for the ideal position in your vehicle. It
will depend on its use and the load distribution.
More information about how to set up the water tank in this link:
https://neil.com.ar/en/installation-tutorials/
EXTERNAL DIMENSIONS OF THE PREMIUM 700 MODEL
Suggested placement
for the water tank
ROOF CUTTING MEASURING

USER MANUAL - PREMIUM 700
PREMIUM MICROPROCESSOR
1 - ALPHANUMERIC DISPLAY
2 - FAN SPEED UP
3 - FAN SPEED DOWN
1 - ALPHANUMERIC DISPLAY
2 - FAN SPEED UP
3 - FAN SPEED DOWN
4 - REMOTE CONTROL SENSOR
5 - COOLER DISPLAY
6 - TIMER
7 - INTERNAL LIGHTING
8 - COOLER ON-OFF
9 - EXTERNAL LIGHTING (old model)
10 - PRE-COOLING SYSTEM
LIGHTING KEYS
The keys backlight is amber and they change to blue when pressed. The level of lighting of the
keys can be regulated with the keys 3 (-) and 2 (+) when the cooler is turned off. When a button
is pressed, a feature is activated, the alarm clock or the lack of water indicator, the keys are
illuminated at maximum for 14 seconds, then they go back to programmed lighting.
COOLING
The Evaporative Cooler is turned ON and OFF with the button 8. To increase or lower the fan
speed use the buttons 2 and 3 that let you choose from 10 different levels. The pre-cooling
system can be turned ON-OFF with the button 10.
An explanatory video about how to use the controller
and its features can be found in the following link:
https://neil.com.ar/en/quick-start-guide/
14
PROGRAMING DISPLAY
DIGITS
ALARM CLOCK
ON-OFF AUTOMATIC
REMOTE CONTROL
SOUND
INTERNAL LIGHTING
EXTERNAL LIGHTING
CLOCK
COOLING DISPLAY
LACK OF WATER SIGNAL
BATTERY LEVEL
FAN
ELECTRICAL OVERLOAD OR
SHORT CIRCUIT
ELECTRONIC BOARD
TEMPERATURE SENSOR
FAN SPEED LEVEL

TIMER
The 4 digits always show the current TIME, except when an ALARM CLOCK or the SOUND are
being programmed. The illuminated icons show that the feature is activated. Pressing the
button 6, the ALARM CLOCK icon is illuminated and the digits indicate the programmed time for
that item. If the button 6 is pressed again, the ALARM icon is illuminated and the display shows
the last programmed time for it to ring. Anytime the button 6 is not being pressed for 5 seconds,
the display will show again the current time and the icon that is illuminated will be the CLOCK.
TIME SETTING
While pressing and holding down the button 6 for 3 seconds, the first two digits (hour) of the
display start blinking. Using the buttons 2 and 3 it is possible to adjust the current time, then
press the button 8 and the other two digits (minutes) will start to blink to adjust them. The last
step is to press and hold the button 8 for five seconds, the digits will show the current time and
the CLOCK icon will stay illuminated.
AUTOMATIC ON-OFF SETTING
With the Evaporative Cooler turned ON, press the button 6 so the AUTOMATIC ON-OFF icon is
illuminated, the digits will start to blink to program the turned OFF time with the buttons 2 and
3. Then press 8 and the display will show the current time, the AUTOMATIC ON-OFF icon will stay
illuminated. To deactivate this feature press 6 and search with the buttons 2 and 3 the word
“OFF” in the display, then press 8. If the cooler is turned OFF, the turn ON time is going to be pro-
grammed.
ALARM CLOCK SETTING
If the button 6 is being pressed twice, the first two digits in the display (hour) will start to blink
and the ALARM CLOCK icon will be illuminated. To adjust the alarm clock timer, buttons 2 and 3
are being used. Then press 8 to adjust the minutes with buttons 2 and 3. Pressing the button 8
the words “ON” and “OFF” will start blinking. Once again, with the buttons 2 or 3 choose if you
want to activate (ON) or deactivate (OFF) the alarm clock. Press 8 so the display shows the
current time and the alarm clock icon will stay illuminated or not, depending on your previous
choice. Opposite to the AUTOMATIC ON-OFF feature, the alarm clock will not be automatically
disconnected when the programmed time setting is accomplished. The alarm clock will ring
again the next day if it is not deactivated.
WATER PUMP POWER SETTING
Depending on the distance between the water tank and the cooler, more or less power will be
needed in the water pump. The water pump is programmed in 50% by default, this corresponds
to a 2 meter long hose approximately. If a 9 meter long hose is being used, the water pump
power can be changed to 100%. To regulate the power, turn off the cooler and press 10 for eight
seconds, the display will show the power level, then select the power level with buttons 2 or 3
and press 10 again to finish the setting. If the battery is disconnected, set it again.
USER MANUAL - PREMIUM 700
15
https://youtu.be/pQ-SH2AVrJA
SEE VIDEO

USER MANUAL - PREMIUM 700
DIRECT MOISTURIZER SYSTEM SETTING
From the 2018 models onwards the direct moisturizer program is activated automatically.
If by any reason the pre-cooling chamber sensors stop working, it is possible to program the
device to work directly until the technical service can check it. It can be activated by following
this steps:
With the device turned on, press the button 10 for eight seconds, it will start to slowly blink. To
disconnect the system press 10 or turn off the device.
LIGHTING
With the buttons 7 and 9 it is possible to turn on and turn off the internal lighting. To turn off the
lights press the corresponding button.
LACK OF WATER SIGNAL
The lack of water in the water tank is indicated by a blinking 10 button.
REMOTE CONTROL
With the remote control it is possible to control the internal lighting, the pre-cooling system,
turn on and off the device, change the fan speed and set the automatic ON-OFF
TO LOWER THE REMOTE CONTROL LIGHTING,
WITH IT TURNED OFF, PRESS THE BUTTON DOWN (-) SEVERAL
TIMES UNTIL BRIGHTNESS IS DECREASED.
16
REMOTE CONTROL
1 - COOLER ON-OFF
2 - SPEED DOWN
3 - EXTERNAL LIGHTING ON-OFF
4 - TIMER
5 - FLASHLIGHT
6 - SPEED UP
7 - PRE-COOLING SYSTEM ON-OFF
BATTERY IS NOT INCLUDED
Table of contents
Popular Temperature Controllers manuals by other brands

S+S Regeltechnik
S+S Regeltechnik THERMASGARD RSTF Operating Instructions, Mounting & Installation

Auber
Auber SYL-1615 instruction manual

HARRICK
HARRICK ATC-024-1 user manual

Dantherm
Dantherm SIMPLIFY Quick installation guide

Mitsubishi Electric
Mitsubishi Electric PAC-TH011HT-E installation manual

Auber Instruments
Auber Instruments SYL-2372 instruction manual