Optional parts
D-25
HIGH TEMP. THERMISTOR
4Optional parts
PARTS NAME : HIGH TEMP. THERMISTOR
PARTS No. : PAC-TH011HT-E <G>
SALES MODEL CODE : 7H1THR2G
WARNING
●
●
●
●
●
●
INSTALLATION MANUAL
●Before starting installation, read the following description together with the installation manual included with the unit.
●Please read carefully and observe fully the following safety precautions.
Precautions that must be observed to prevent injuries or death.
WARNING
After installation carry out a test run to ensure correct operation, then explain operation method and safety precautions to the
end user.
Tell your customers to keep this installation manual together with the operation manual, and when they give or sell this
machine to any other person include this installation manual and operation manual with it.
Before installing any accessories on the unit ensure the unit is isolated from the power supply.
Connections must be made securely and without tension on the terminals.
All electrical work should be performed by a qualified technician according to local regulations and the instructions given
in this manual.
The flow temperature from boiler MUST NOT exceed 70 °C (*1).
Before running Floor Dry-up function, disconnect IN4 and IN5 wirings. (*2)
*1 When the temperature sensed by flow temp. thermistor or return temp. thermistor exceeds 80°C, FTC4 will detect it as overheat error.
*2 High-temperature water produced by boiler operation could flow in and this could cause a big damage to the floor.
Make sure to install the boiler that has overheat protection and output flow temperature control.
●
CNP1(WHT)
TBI.1
CNV1
(WHT)
FTC 4
TBO.2
TBO.1
1
3
1
5
1
3
1
5
SW3
1
8
1
6
1
5
CN01
(BLK)
1
3
CN3C
(BLU)
CNBH
(WHT)
1
7
CNBC
(GLY)
1
3
CNBHT
(BLK)
1
3
CNIH
(ORN)
1
2
CN22
(BLU)
CN2F
(YLW)
1
3
CN20
(RED)
CN21
(YLW)
1
3
CNW12
(RED)
CNW5
(WHT)
1
2
1
4
1
2
TBI.2
LED1
LED2
CNPWM
(WHT)
1
3
SW2
1
8
SW1
1
8
SW4
CN108
CNRF
(WHT)
LED4
LED3
1
5
CN105
(RED)
Item Piece
1Boiler flow temp. thermistor (THWB1) 5 m,
color: gray 1
2Boiler return temp. thermistor (THWB2) 5 m,
color: black 1
3 Installation manual 1
<Included items>
<Connecting boiler thermistor>
123
1234567891011121314
TBI.2
THWB1 THWB2
Optional parts
D-26
HIGH TEMP. THERMISTOR
4Optional parts
Heat source
Heating
DHW
Heat pump
Boiler —
a) Heating room temperature ( )
FTC4
Boiler
Outdoor unit
b) Heating flow temperature ( )
c) Heating compensation curve ( )
FTC4
Boiler
Outdoor unit
Wireless remote
controller (option)
or
Room temperature
thermistor (option)
or
Main controller (remote
position)
Room thermostat (field
supply)
or
Wireless remote controller *
(option)
Room thermostat
* Wireless remote controller can be changed to room thermostat.
1.2 Pipe work
(a) Boiler and heat pump are connected in parallel.
(b) Install a mixing tank (field supply).
(c) Put 2 thermistors in boiler circuit. (THWB1: Flow temp., THWB2: Return temp.)
* It is recommended to protect the thermistors with heat insulating materials so as not to be affected by ambient temperature.
Note: These lead wires of the thermistors must avoid being in contact with pipe surfaces.
Boiler
Heating
Mixing tank
(field supply)
Cylinder unit/
Hydrobox
Outdoor unit
1
2
3
4
5
6
Boiler
Heating
Mixing tank
(field supply)
Hydrobox
DHW tank
Outdoor unit
1
2
7
8
9
3
4
5
6
Number Component
1 Boiler flow temp. thermistor (THWB1)
2 Boiler return temp. thermistor (THWB2)
3 Flow temp. thermistor (THW6) (option)
4 Return temp. thermistor (THW7) (option)
5 Circulation pump (field supply)
6 Flow switch (field supply) *1
*1 For safety protection, it is recommended to install a flow switch.
Number Component
1 Boiler flow temp. thermistor (THWB1)
2 Boiler return temp. thermistor (THWB2)
3 Flow temp. thermistor (THW6) (option)
4 Return temp. thermistor (THW7) (option)
5 Circulation pump (field supply)
6 Flow switch (field supply) *1
7 Tank water temp. (THW5)
8 Immersion heater (field supply)
9 3-way valve (field supply) *2
*1 For safety protection, it is recommended to install a flow switch.
*2 The use of two 2-way valves can perform the same function as a 3-way
valve.
1. System
1) Heat source can be switched between heat pump and boiler by external input from power supplier or outdoor temperature
thermistor.
2) Heat source can be switched according to running cost, CO2emission, or outdoor temp.
3) In case of outdoor unit failure, backup operation is possible with boiler. *1
*1 When Hybrid is selected as heat source.
When Dip SW2-5 (Automatic switch to backup heat source operation) is set to ON.
Note: FTC4 can control boiler only in space heating mode.
1.1 Room thermostat connection
IMPORTANT NOTE
Be sure to connect room thermostat to FTC4.
When boiler is running, the heating operation is regulated by the room thermostat connected to FTC4.
Room thermostat

This manual suits for next models

1

Other Mitsubishi Electric Temperature Controllers manuals

Mitsubishi Electric PAC-IF051B-E User manual

Mitsubishi Electric

Mitsubishi Electric PAC-IF051B-E User manual

Mitsubishi Electric PMCR-50VHA-200D KIT User manual

Mitsubishi Electric

Mitsubishi Electric PMCR-50VHA-200D KIT User manual

Mitsubishi Electric PAC-IF032B-E User manual

Mitsubishi Electric

Mitsubishi Electric PAC-IF032B-E User manual

Mitsubishi Electric 2BR Guide

Mitsubishi Electric

Mitsubishi Electric 2BR Guide

Mitsubishi Electric EHPT20 Series User manual

Mitsubishi Electric

Mitsubishi Electric EHPT20 Series User manual

Mitsubishi Electric PAC-USWHS003-TH-1 Service manual

Mitsubishi Electric

Mitsubishi Electric PAC-USWHS003-TH-1 Service manual

Mitsubishi Electric PCA Series User manual

Mitsubishi Electric

Mitsubishi Electric PCA Series User manual

Mitsubishi Electric PAC-USSEN001-FM-1 Service manual

Mitsubishi Electric

Mitsubishi Electric PAC-USSEN001-FM-1 Service manual

Popular Temperature Controllers manuals by other brands

Omron E5ZN Series brochure

Omron

Omron E5ZN Series brochure

MAXA HCN Series Installation, Use and Technical Manual

MAXA

MAXA HCN Series Installation, Use and Technical Manual

Avtech RMA-DET-SEN Installation notes

Avtech

Avtech RMA-DET-SEN Installation notes

Autonics TM Series user manual

Autonics

Autonics TM Series user manual

GUILCOR AR006684 instruction manual

GUILCOR

GUILCOR AR006684 instruction manual

ITT Neo-Dyn 100T Installation and operation

ITT Neo-Dyn

ITT Neo-Dyn 100T Installation and operation

Honeywell T775A user manual

Honeywell

Honeywell T775A user manual

Omega CN710 instruction sheet

Omega

Omega CN710 instruction sheet

Ledwide Lighting LW­-CTA-­1 manual

Ledwide Lighting

Ledwide Lighting LW­-CTA-­1 manual

Honeywell PERFECT CLIMATE COMFORT CENTER owner's guide

Honeywell

Honeywell PERFECT CLIMATE COMFORT CENTER owner's guide

Autonics TN Series instruction manual

Autonics

Autonics TN Series instruction manual

2VV ESSENSSE NEO COMFORT Installation and operation instractions

2VV

2VV ESSENSSE NEO COMFORT Installation and operation instractions

Elko SmartSensor Climate Wireless user guide

Elko

Elko SmartSensor Climate Wireless user guide

Omron E5CD-B-800 Series instruction manual

Omron

Omron E5CD-B-800 Series instruction manual

Eurotherm 2116 user guide

Eurotherm

Eurotherm 2116 user guide

Danfoss ECL Comfort 110 operating guide

Danfoss

Danfoss ECL Comfort 110 operating guide

Okolab H401-T-PENNY manual

Okolab

Okolab H401-T-PENNY manual

Heatmiser TM1-TS WiFi RF instruction manual

Heatmiser

Heatmiser TM1-TS WiFi RF instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.