The CP027 two channel programmer gives independent
control over hot water and heating with up to 3 ON/OFF settings
for each day of the week. It also has a 1 hour manual boost
button for the hot water and an advance button for the central
heating.
There is also a programming switch allowing permanent
selection of: OFF / ON / AUTO / ALL DAY.
Two Channel Central Heating and
Hot Water Programmer

The simple instructions contained in this user guide are
designed to help with the programming and operation of the
unit.
2
The CP027 Programmer
1 SET indicator
2Time of day
3 Switch period symbol
4 SET button
5 Hot water BOOST or
adjust (-) button
6 Central Heating ADVANCE
or adjust (+) button
7 Hot water (HW) or
ENTER button
8Central Heating (CH) or
COPY button
9 Hot water ON indicator
10 Central heating ON
indicator
11 SET positions
12 PROGRAMMEpositions
13 BOOST symbol
14 ADVANCE symbol
15 AM/PM symbol
16 Day of week indicator
17 PROGRAMME indicators

The installer will have set the programmer to suit the installed
system. This is normally a Fully Pumped system which will
allow independent control of the central heating and hot water,
however on an old Gravity system the central heating and hot
water are linked so that it is not possible to use the central
heating independently. This will allow only one common time
setting for both hot water and central heating, and will become
apparent when setting the ON and OFF times as both will be
indicated together.
3
Fully Pumped or Gravity System
BOOST FUNCTION - 1 HOUR TEMPORARY OVERRIDE
(HOT WATER ONLY)
The boost facility will allow the user to boost the hot water
channel which is currently ‘OFF’ for 1 hour. To indicate the boost
being activated BOOST will be shown on the display for the
duration of the boost period. The hot water channel ON
indicator will also be illuminated.
Manual Overrides
Press BOOST
button once for
1 hour of hot
water
At any time
during a BOOST
period press
BOOST again to
return to normal
programming
RUN
CLOCK
HW PROG
CH PROG
6:35
PM BOOST
HW CH
AUTO
ALL DAY
24 HRS
OFF

4
ADVANCE FUNCTION – BRINGS FORWARD THE NEXT ON
OR OFF OPERATION (CENTRAL HEATING ONLY)
The advance facility will allow the user to switch the central
heating channel ‘ON’ which is currently ‘OFF’ or switch the
central heating channel ‘OFF’ which is currently ‘ON’. To
indicate the advance feature being activated ADVANCE will be
shown on the display until the next programme switching time.
The central heating ON indicator will also be illuminated.
With the CP027 operating in the normal running mode it is
possible to alter the functionality of the programme on each
individual channel by means of the CH and HW buttons.
The options include;
Auto - Channel follows all programmed ‘ON’ and ‘OFF’ times.
All day - Channel operates from 1st ‘ON’ time until 3rd ’OFF’,
ignoring all switching times in between.
24hrs - Channel will be constantly ‘ON’.
Off - Channel will be constantly ‘OFF’, there is the ability to turn
off the heating during the summer without altering the
programme times. On the hot water channel the boost is still
available. As both channels are totally independent it is
possible to have them set differently if necessary.
Programme Override Facilities
Press
ADVANCE
button once to
move to the
next ON/OFF
time
To cancel the
advance press the
ADVANCE button
again. this will
return the unit to
its normal
programme
RUN
CLOCK
HW PROG
CH PROG
6:35
PM ADVANCE
HW CH
AUTO
ALL DAY
24 HRS
OFF

All of the settings above will be permanent, i.e. unaffected by
programme times, until alteration by the user.
The diagram below illustrates how to alter the setting, it
assumes that the channel is in the AUTO mode to begin with.
The CP027 has a built in clock and calendar. This will mean that
you will need to enter the date as well as the time on initial set up
or if the factory re-set has been used. Having done this, the
clock will automatically adjust for BST/GMT time changes
throughout the year.
Setting Time of Day and Date
5
Press HW
OR CH once.
Programme
goes from
AUTO to
ALL DAY
Press HW
OR CH again.
Programme
goes from
ALL DAY to
24 HRS
Press HW
OR CH again.
Programme
goes from
24 HRS to
OFF
Press HW
OR CH again.
Programme
goes from
OFF to
AUTO
Programme
will operate
from 1st ON
until 3rd
OFF period
Programme
will be
continuously
ON
Programme
will be
continuously
OFF
Programme
will return
to normal
ON and OFF
times
6:35
PM
HW CH
AUTO
ALL DAY
24 HRS
OFF
6:35
PM
HW CH
AUTO
ALL DAY
24 HRS
OFF
6:35
PM
HW CH
AUTO
ALL DAY
24 HRS
OFF
6:35
PM
HW CH
AUTO
ALL DAY
24 HRS
OFF
Press the
set button
until the set
indicator is
next to the
‘clock’
position
Use the
+ and -
buttons to
adjust the
hour and
press
ENTER
Use the
+ and -
buttons to
adjust the
minutes
and press
ENTER
Use the
+ and -
buttons to
set the
date and
press
ENTER
Use the
+ and -
buttons to
set the
month and
press
ENTER
Use the
+ and -
buttons to
set the
year and
press
ENTER
Once the year is set and the ENTER
button is pressed the process is
complete and the display will return
to the run position
Check that the correct time and day are
showing in the display. If the wrong day is
showing in the display that would indicate
that the date has not been set correctly
and the above process should be repeated

To alter these settings please proceed as follows:-
Setting the On and Off Times
Default Time settings
The default time settings shown above are preset at the factory
st st nd nd rd rd
1 ON 1 OFF 2 ON 2 OFF 3 ON 3 OFF
6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM
NB. The factory default settings for the 2nd ON/OFF times are both set at 12:00pm
(midday) which cancels this ‘ON’ period giving 2 ON/OFF periods for the day. If a midday
‘ON’ period is required set the 2nd ON and OFF times accordingly. If not press ENTER
twice.
6
Press the
set button
until set
indicator is
next to HW
or CH
PROG
Position
Use
+ and -
buttons
to adjust
day
Press
ENTER
Press
ENTER
Use
+ and -
buttons
to adjust
1st ON
time
Use
+ and -
buttons
to adjust
1st OFF
time
Press
ENTER
Repeat this
process for
2nd and 3rd
settings
Enter the
3rd OFF time
and the word
COPY is
displayed
To follow the copy
route and repeat all
programmed times
for another day go
to 1
To set independent
times for other
days go to 2
Use the + and - buttons to select
day required and press COPY ‘IN’
is displayed to confirm the COPY
Repeat for other days as required
To transfer to independent times for other
days go to 2 or to finish programming
press the SET button until the SET
indicator is in the RUN position
1
Press ENTER. Use the + and -
buttons to select the day required
and press ENTER. Set 1st, 2nd and
3rd times as before. To repeat for
other days go to 2, to COPY go to 1
To finish programming press the
SET button until the SET
indicator is in the RUN position
2

Resetting the Programmer Electronic equipment can in some
circumstances be affected by electrical interference. If the
programmer’s display becomes frozen or scrambled; or if you
wish to revert back to the default time settings please reset by
pressing the SET and CH buttons together as shown below.
After initial installation it is advisable, before programming the
CP027 for the first time, to reset the unit. Resetting can only be
achieved with the power ‘ON’ by pressing the SET and CH
buttons together. This will return the programmer to the factory
set default times.
Resetting the Programmer
7
Press the SET and CH buttons
together then release the buttons
and the programmer will return to
preset factory settings SET
CH

Part Number P85483 Issue 1
8
BATTERY
The programmer is fitted with a non-rechargeable, long life
battery, which will maintain the programmed time settings for a
minimum of ten months with the supply disconnected.
THIS SHOULD BE SUFFICIENT TO COVER POWER
INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3
days the current time of day will be lost. These measures are to
prolong the battery life.
SERVICE AND REPAIR
This programmer is NOT user serviceable. Please do not
dismantle the unit. In the unlikely event of a fault developing
please refer to the RESETTING THE PROGRAMMER section
of this user guide shown above. If this fails to resolve the
problem please contact a local heating engineer or a qualified
electrician.
General Information
www.iQE.co.uk
Trade House BA22 8RT
Other manuals for CP027
1
Table of contents
Other iQe Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

MULTISPAN
MULTISPAN UTC - 413P operating manual

Auber Instruments
Auber Instruments ECT-100 instruction manual

AMX
AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE... instruction manual

Omron
Omron EJ1 EtherCAT instruction manual

TE Technology
TE Technology TC-48-20 instruction manual

Elvaco
Elvaco CMa10w quick start guide