Nemtek MERLIN M25 User manual

GROUP OF COMPANIES
USER MANUAL
M28 M25
MERLIN M-SERIES -
Electric Fence Control Panel
FENCE GATE SERVICE
DUAL ZONE

1
MERLIN Electric Fence Control Panel
User Manual
SWITCH THE FENCE ON / OFF
To switch the fence On or Off, enter your four digit PIN followed by the # key. The control panel will
beep twice to confirm that the fence is off and three times when the fence is turned on.
•If the red ON light is lit or flashing, the fence is energized
•Don’t pause for more than 5 seconds while entering the digits, or the control panel will reject
your PIN number
•If you make a mistake while entering your PIN, press the # key and start again
•An incorrect PIN will cause the control panel to beep 5 times
•The default master PIN is 1 2 3 4
AFTER AN ALARM OCCURS
Enter your PIN and push the # key. This will silence the buzzer and siren. It will not switch the fence
off. One of the ALARM lights will flash or stay lit to indicate the type of alarm. Investigate the cause of
the alarm and correct it. After the ALARM light stops flashing, enter your PIN and push the # key to
clear the alarm memory.
CHANGE THE VOLTAGE ON THE FENCE
Enter your PIN and push the * key, enter the digit ‘3’, then push# key. The control panel will beep three
times to confirm the fence is in low voltage mode. When the fence is on and in low voltage mode, the
red ON light will flash. The red ON light will stay lit if the fence is in high voltage mode.
BYPASS THE FENCE ALARM (ZONE 1 & 2)
Enter your PIN and push the * key, enter the digit ‘1’, then push the # key. The control panel will beep 3
times and the FENCE ALARM and ZONE 1 & 2 lights will start flashing slowly to confirm that zone 1 & 2
are bypassed. To cancel the bypass, repeat the same sequence of keys.
BYPASS THE FENCE ALARM (ZONE 1)
Enter your PIN and push the * key, enter the digit ‘1’, followed by the digit ‘1’, then push the # key. The
control panel will beep 3 times and the FENCE ALARM and ZONE 1 lights will start flashing slowly to
confirm that zone 1 is bypassed. To cancel the bypass, repeat the same sequence of keys.
BYPASS THE FENCE ALARM (ZONE 2)
Enter your PIN and push the * key, enter the digit ‘1’, followed by the digit ‘2’, then push the # key. The
control panel will beep 3 times and the FENCE ALARM and ZONE 2 lights will start flashing slowly to
confirm that zone 2 is bypassed. To cancel the bypass, repeat the same sequence of keys.
#
#
#
3
#
1
#
1
1
#
2
1

2
MERLIN Electric Fence Control Panel
User Manual
BYPASS THE SIREN AND STROBE LIGHT (SILENT ALARM)
Enter your PIN and push the * key, enter the digit ‘4’, then push the # key. The control panel will beep 3
times to confirm the siren and strobe light is bypassed. The beeper in the control panel and the
energizer unit will still be active.
UN-BYPASS THE SIREN AND STROBE LIGHT
Enter your PIN and push the * key, enter the digit ‘7’, then push the # key. The control panel will beep
twice to confirm that the siren and strobe light is NOT bypassed.
MAKE THE GATE ALARM IMMEDIATE (GATE 1 & 2)
Enter your PIN and push the key, followed by the digit ‘7’, then push the # key. The control panel
will beep twice and the GATE ALARM and GATE 1 & 2 lights will start flashing very slowly (every 5
seconds) to confirm that the gate 1 & 2 alarms are immediate.
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, then push the # key. The
control panel will beep twice and the GATE ALARM and GATE 1 & 2 lights will start flashing very slowly
(every 5 seconds) to confirm that the gate 1 & 2 alarms are immediate.
MAKE THE GATE ALARM IMMEDIATE (GATE 1)
Enter your PIN and push the key, followed by the digit ‘7’, followed by the digit ‘1’, then push the
# key. The control panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very
slowly (every 5 seconds) to confirm that the gate 1 alarm is immediate.
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, followed by the digit ‘1’,
then push the # key. The control panel will beep twice and the GATE ALARM and GATE 1 lights will start
flashing very slowly (every 5 seconds) to confirm that the gate 1 alarm is immediate.
MAKE THE GATE ALARM IMMEDIATE (GATE 2)
Enter your PIN and push the key, followed by the digit ‘7’, followed by the digit ‘2’, then push the
# key. The control panel will beep twice and the GATE ALARM and GATE 2 lights will start flashing very
slowly (every 5 seconds) to confirm that the gate 2 alarm is immediate.
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, followed by the digit ‘2’,
then push the # key. The control panel will beep twice and the GATE ALARM and GATE 2 lights will start
flashing very slowly (every 5 seconds) to confirm that the gate 2 alarm is immediate.
#
4
#
7
#
7
2
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
#
7
1
#
7
#
7
1
2
2
#
7
#
7
2
2

3
MERLIN Electric Fence Control Panel
User Manual
MAKE THE GATE ALARM DELAYED (GATE 1 & 2)
Enter your PIN and push the key, enter the digit ‘4’, then push the # key. The control panel will
beep twice to confirm that the gate 1 & 2 alarms are delayed. The default delay time is 4 minutes.
#
4
2
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘4’, then push the # key. The
control panel will beep twice to confirm that the gate 1 & 2 alarms are delayed. The default delay time is
4 minutes.
MAKE THE GATE ALARM DELAYED (GATE 1)
Enter your PIN and push the key, enter the digit ‘4’, followed by the digit ‘1’, then push the # key.
The control panel will beep twice to confirm that the gate 1 alarm is delayed. The default delay time is 4
minutes.
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘4’, followed by the digit ‘1’,
then push the # key. The control panel will beep twice to confirm that the gate 1 alarm is delayed. The
default delay time is 4 minutes.
MAKE THE GATE ALARM DELAYED (GATE 2)
Enter your PIN and push the key, enter the digit ‘4’, followed by the digit ‘2’, then push the # key.
The control panel will beep twice to confirm that the gate 2 alarm is delayed. The default delay time is 4
minutes.
Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘4’, followed by the digit ‘2’,
then push the # key. The control panel will beep twice to confirm that the gate 2 alarm is delayed. The
default delay time is 4 minutes.
BYPASS THE GATE ALARM (GATE 1 & 2)
Enter your PIN and push the key, then push the # key. The control panel will beep 3 times and
the GATE ALARM and GATE 1 & 2 lights will start flashing slowly to confirm that the gate 1 & 2 alarms
are bypassed. To cancel the bypass, repeat the same sequence of keys.
#
2
Enter your PIN and push the * key, enter the digit ‘2’, then push the # key. The control panel will beep 3
times and the GATE ALARM and GATE 1 & 2 lights will start flashing slowly to confirm that the gate 1 & 2
alarms are bypassed. To cancel the bypass, repeat the same sequence of keys.
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
#
4
1
#
4
#
4
1
2
2
#
4
#
4
2
2
#

4
MERLIN Electric Fence Control Panel
User Manual
BYPASS THE GATE ALARM (GATE 1)
Enter your PIN and push the key, enter the digit ‘1’, then push the # key. The control panel will
beep 3 times and the GATE ALARM and GATE 1 lights will start flashing slowly to confirm that the gate 1
alarm is bypassed. To cancel the bypass, repeat the same sequence of keys.
Enter your PIN and push the * key, enter the digit ‘2’, followed by the digit ‘1’, then push the # key. The
control panel will beep 3 times and the GATE ALARM and GATE 1 lights will start flashing slowly to
confirm that the gate 1 alarm is bypassed. To cancel the bypass, repeat the same sequence of keys.
BYPASS THE GATE ALARM (GATE 2)
Enter your PIN and push the key, enter the digit ‘2’, then push the # key. The control panel will
beep 3 times and the GATE ALARM and GATE 2 lights will start flashing slowly to confirm that the gate 2
alarm is bypassed. To cancel the bypass, repeat the same sequence of keys.
Enter your PIN and push the * key, enter the digit ‘2’, followed by the digit ‘2’, then push the # key. The
control panel will beep 3 times and the GATE ALARM and GATE 2 lights will start flashing slowly to
confirm that the gate 2 alarm is bypassed. To cancel the bypass, repeat the same sequence of keys.
TURN THE GATE CHIME ON / OFF (GATE 1 & 2)
Push the key, then push the # key. The control panel will beep twice to confirm that the gate
chime is turned off and three times if it’s turned on. If the chime is on, the control panel will beep twice
if gate 1 or 2 closes and three times if it opens.
#
2
Push the * key, enter the digit ‘2’, then push the # key. The control panel will beep twice to confirm that
the gate chime is turned off and three times if it’s turned on. If the chime is on, the control panel will
beep twice if gate 1 or 2 closes and three times if it opens.
TURN THE GATE CHIME ON / OFF (GATE 1)
Push the key, enter the digit ‘1’, then push the # key. The control panel will beep twice to
confirm that the gate chime is turned off and three times if it’s turned on. If the chime is on, the control
panel will beep twice if gate 1 closes and three times if it opens.
Push the * key, enter the digit ‘2’, followed by the digit ‘1’, then push the # key. The control panel will
beep twice to confirm that the gate chime is turned off and three times if it’s turned on. If the chime is
on, the control panel will beep twice if gate 1 closes and three times if it opens.
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
#
1
#
1
2
#
2
#
2
2
#
#
1
#
1
2

5
MERLIN Electric Fence Control Panel
User Manual
Master PIN
User (1-6)
New PIN
New PIN
TURN THE GATE CHIME ON / OFF (GATE 2)
Push the key, enter the digit ‘2’, then push the # key. The control panel will beep twice to
confirm that the gate chime is turned off and three times if it’s turned on. If the chime is on, the control
panel will beep twice if gate 2 closes and three times if it opens.
Push the * key, enter the digit ‘2’, followed by the digit ‘2’, then push the # key. The control panel will
beep twice to confirm that the gate chime is turned off and three times if it’s turned on. If the chime is
on, the control panel will beep twice if gate 2 closes and three times if itopens.
BYPASS THE SERVICE ALARM
#
9
Enter your PIN and push the * key, enter the digit ‘9’, then push the # key. The control panel will beep 3
times and the SERVICE ALARM light will start flashing slowly to confirm that the service alarm is
bypassed. To cancel the bypass, repeat the same sequence of keys.
STANDBY BATTERY TEST
#
6
Push the * key, enter the digit ‘6’, then push the # key. The control panel will beep twice and start
testing the battery. The default battery test duration is 5 minutes.
CHANGING A USER PIN
#
#
#
#
0
Enter your master PIN, push the * key, enter the digit ‘0’, then push the # key. Enter the user number
(1-6), and push the # key. User number 1 is the master PIN. Enter that user’s new PIN and push the #
key. Enter the new PIN again and push the # key. If the new PIN is accepted, the control panel will
beep twice. If you make a mistake while programming, or if the system rejects the new PIN, the control
panel will beep five times. The default master PIN is 1 2 3 4.
KEY DEFINITIONS:
Four digit Personal Identification Number (PIN)
OLD
VERSION
KEYPAD
NEW
VERSION
KEYPAD
#
2
#
2
2

6
MERLIN Electric Fence Control Panel
User Manual
WHAT THE LIGHTS MEAN:
Condition: Power
Light On
Light
Gate
Light
Service
Light Good
Light
Fence
Light
Remarks
FENCE GOOD ON ON OFF OFF SLOW
FLASH OFF Fence on, working
properly
FENCE OFF ON OFF OFF OFF OFF OFF Fence off, working
properly
MAINS FAILURE OFF System on battery
power
BATTERYLOW SLOW
FLASH Check mains supply
BATTERYFLAT SLOW
FLASH SLOW
FLASH FAST
FLASH Check mains, call for
service
FENCE CHECK SLOW
FLASH OFFOFF Check fence for
vegetation
FENCE CHECK ON OFF OFF Check fence for
vegetation
FENCE ALARM OFF FAST
FLASH Problem on fence
FENCE LV MODE SLOW
FLASH Fence in low voltage
mode
FENCE BYPASS SLOW
FLASH Fence alarm switched
off
GATE OPEN FAST
FLASH Gate is open
GATE BYPASS SLOW
FLASH Gate alarm is
switchedoff
INSTANT GATE PULSE
(5 SEC) Instant gate alarm
SERVICE ALARM FAST
FLASH Call for service
SERVICE BYPASS SLOW
FLASH Service alarm is
switchedoff
ALARM MEMORY (ON) (ON) (ON) Old alarm condition
NEMTEK GROUP OUTLETS
RANDBURG
Tel: +27 (0)11 462-8283
Fax: +27 (0)11 462-7132
EDENVALE
Tel: +27 (0)11 453-
1970
Fax: +27 (0)11 453-
1858
Web site: http//www.nemtek.com
E-mail: [email protected]
MANUFACTURED IN SOUTH AFRICA
Other manuals for MERLIN M25
1
Table of contents