New lift EAZ 256 User manual

Position indicator
Manual

02 ManualEAZ-256
Manufacturer NEWLIFTSteuerungsbauGmbH
LochhamerSchlag8
82166Graefelfing
Tel +49 89 – 898 66 – 0
Fax +49 89 – 898 66 – 300
Mail [email protected]
www.newlift.de
Service line Tel +49 89 – 898 66 – 110
Mail [email protected]
Date of issue 12.09.2013
Author TB/EP
Release AL
Doc. No. hb_eaz256_en
Copyright ©NEWLIFTSteuerungsbauGmbH,2013.
Thismanualisprotectedbycopyright.Allrights,includingthoseofcopying,of
reproduction,oftranslationandofmodification,inwholeorinpart,arereservedby
thepublisher.
Nopartofthisdescriptionmaybereproducedinanyformorcopiedwithan
electronicreplicationsystemwithoutwrittenpermission.
Althoughgreatcarehasbeentakenintheproductionoftextsandfigures,we
cannotbeheldlegallyliableforpossiblemistakesandtheirconsequences.

ManualEAZ-256 I
Inhalt
1 General 1
1.1 Signs and symbols used 1
1.2 Further information 1
1.3 How to contact us 2
1.4 General safety regulations 2
1.4.1 Standardsandregulationsapplied 2
1.4.2 Electromagneticcompatibility(EMC) 2
1.4.3 Handlingelectronicassemblies 2
2 EAZ-256/40 3
2.1 Technical data 3
2.2 Connection assignment and configuration 4
2.2.1 TerminalX3 4
2.2.2 Jumper 4
3 EAZ-256/64 5
3.1 Technical data 5
3.1.1 TerminalX3 6
3.1.2 Jumper 7
4 EAZ-256/64.G 8
4.1 Technical data loudspeaker 8
4.2 Settings on the loudspeaker 8
5 EAZ-256/64.FPM-2 9
5.1 Technical data 9
6 Diagnostic assistance 10
7 Settings in the FST menu 11
7.1.1 Settingfloornames 11
7.1.2 Settingtypeofpositionindicator 11
7.1.3 Settingoptionsforpositionindicator 11

II ManualEAZ-256

General
Signsandsymbolsused
ManualEAZ-256 1
1 General
The EAZ-256/40 and EAZ-256/64 dot matrix position indicators have been developed for the FST-Controller
manufactured by NEW LIFT.
They have a LON-bus interface and features that far surpass the options of the conventional position indicators:
› Dynamic parametrising of the name displayed for each oor from the controller
› Dynamic parametrising of the display options from the controller
› Automatic display of all system states such as overload, out-of-order, special drive, re recall, reman service
etc.
› The EAZ-256 is available in ve colors: blue, red, green, amber and optionally white.
The EAZ-256 is available in various models. The table below provides the respective functions of the modules:
Function EAZ-256/40 EAZ-256/64 EAZ-256/64.G EAZ-256/64.FPM-2
Display area 40 x 40 mm 64 x 64 mm 64 x 64 mm 64 x 64 mm
Integrated ADM –
Acoustic call acknowledgment – –
Integrated chime function – –
with external loudspeaker – – –
1.1 Signs and symbols used
EAZ position indicator
Delivery condition
Settings that are supplied as standard are marked with an asterisk .
Abbreviation used for detailed terminal information
P power
I input
O output
L low active
H high active
Safety-relevant information
This symbol indicates safety-relevant information
Information notice
This symbol indicates useful information
1.2 Further information
The following documents, among others, are available for the FST controller and its components:
› FST Installation & Commissioning
› FST manual
› ADM manual
› FPM manual
› SAM manual
› Fire recall manual
Diese und weitere aktuelle Anleitungen nden Sie auf unserer Web-Seite im Downloadbereich unter Service
http://www.newlift.de/service/download

General
Howtocontactus
2 ManualEAZ-256
1.3 How to contact us
If, after referring to this manual, you still require assistance, our service line is there for you:
Tel +49 89 – 898 66 – 110
Mail [email protected]
Mon. - Thurs.: 08:00 a.m. – 12:00 p.m. and 1:00 p.m. – 5:00 p.m.
Fr: 08:00 a.m. – 12:00 p.m. and 12:30 – 3:00 p.m.
1.4 General safety regulations
The EAZ-256 position indicators must only be operated in perfect working condition in a proper manner, safely
and in compliance with the instructions, the valid accident prevention regulations and the guidelines of the local
power company.
Basically, the safety regulations of the FST manual and the FST manual installation & commissioning apply.
1.4.1 Standards and regulations applied
All EAZ-256 position indicators comply with:
› the safety guidelines for the construction and installation of passenger and goods passenger lifts (DIN EN 81
Part 1 and 2).
› the conditions for the erection of high voltage installations with nominal voltages up to 1 kV (DIN VDE 0100).
› the contact protection measures in the machine room (VDE 0106).
› the data sheet on safety measures for the installation, maintenance and commissioning of lift systems (ZH
1/312).
1.4.2 Electromagnetic compatibility (EMC)
An accredited inspection authority has inspected the FST control system and its components in accordance with
the standards, thresholds and severity levels named in EN 12015/1995 and EN 12016/1995.
The FST control system and its components are:
› immune to electrostatic discharge (EN 61000-4-2/1995)
› immune to electrostatic elds (EN 61000-4-3/1997)
› immune to fast transient disturbances (EN 61000-4-4/1995)
The electromagnetic disturbance eld strengths created by the FST control system and its components do not
exceed the permissible thresholds. (EN 55011/1997).
1.4.3 Handling electronic assemblies
› Keep the electronic assembly in its original packaging until installation.
› Before opening the original packaging, a static discharge must be performed. To do this, touch a grounded
piece of metal.
› During work on electronic assemblies, periodically perform this discharge procedure.
› All bus inputs and outputs not in use must be equipped with a terminal resistor (terminator).

EAZ-256/40
Technicaldata
ManualEAZ-256 3
2 EAZ-256/40
The EAZ-256/40 position indicator is a high quality 16x16 LED dot matrix display with a display area of 40 x 40
mm.
Terminal X3 enables the connection of landing calls, key swithes and chime signals. Therefore, no ADM landing
call module is required when using EAZ-256/40 in the landing control panel.
EAZ-256/40 can be used on shaft access from the outside or as LON oor position indicator in the car, because
of different special texts or symbols that can be displayed here. These settings can be made via jumper.
2.1 Technical data
Description Value
Supply voltage 24 V DC ±10%
Typical power consumption 100 mA
Outputs short circuit proof
Length x Hight x Depth (+x: zusätzlicher Abstand für Kabel) 50 x 70 (+20) x 30 mm
Bolt M3 x 25 mm
Installation depth 35 mm
Bezel cutout 48 x 48 mm; r = 3 mm
Temperature range: Storage & Transportation / Operation -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & Transportation / Operation
(non-condensing)
+5 – +95 % / +15 – +85 %
J3
V
S
LD1
J5
J4J6
1 mm
2 mm
3 mm 48
52
X2 X1
250 mA
50
5
70
60 5
Fig. 2.1: EAZ-256/40_V2 Circuit board drawing
J3
X2 X1 V
S
LD1
J5
J4J6
1 mm
2 mm
3 mm 48
52
50
5
70
60 5
Fig. 2.2: EAZ-256/40 Circuit board drawing
Bezel cutout
cornerradius3mm
Bezel cutout
cornerradius3mm

EAZ-256/40
Connectionassignmentandconfiguration
4 ManualEAZ-256
2.2 Connection assignment and configuration
2.2.1 Terminal X3
The terminal X3 is needed for connecting of landing control panel components when using EAZ-246/40 on
landing contol panel.
EAZ-256/40 X3 Function Technical details
1 + 24 V P
2 Landing call UP I/O; L 350 mA / 24 V
3 Landing call DOWN I/O; L 350 mA / 24 V
4 Landing call release O; L 350 mA / 24 V
5 Direction UP O; L 350 mA / 24 V
6 Direction DOWN O; L 350 mA / 24 V
7 Chime trigger O; L 350 mA / 24 V
8 Key switch 1 I; L
9 Key switch 2 I; L
10 GND P
11 No function at the moment from version 2.x
12 No function at the moment from version 2.x
The terminals labelled with key switch 1 and key switch 2 can be factory-provided with the following functions:
re recall, smoke detector, remote shutdown and landing priority.
2.2.2 Jumper
The service jumper S is not plugged in.
Jumper V: Installation position
Installation position V
horizontal („TOP-H“) open
vertical („TOP-V“) plugged
Jumper J3 – J5
FST allocation J3 J4 J5
FST A open open open
FST B plugged open open
FST C open plugged open
FST D plugged plugged open
FST E open open plugged
FST F plugged open plugged
FST G open plugged plugged
FST H plugged plugged plugged
Jumper J6: Installation location
Installation location J6
landing open
car plugged

EAZ-256/64
Technicaldata
ManualEAZ-256 5
3 EAZ-256/64
The EAZ-256/64 position indicator is a high quality 16x16 LED dot matrix display with a display area of 64 x 64
mm.
In addition to two acknowledgeable call button connections and an integrated Piezo Summer for acoustic call
acknowledgement according to EN81-70, the EAZ-256/64 has also an integrated chime function according
to EN81-70 for the approach chime (one sound for up, two sounds for down). The suitable loudspeaker is not
included with this delivery (see chapter 4 EAZ-256/64G).
Terminal X3 enables the connection of landing calls and key swithes. No ADM landing call module is required
when using EAZ-256/64 in the landing control panel.
EAZ-256/64 can be used on shaft access from the outside or as LON oor position indicator in the car, because
of different special texts or symbols that can be displayed here. These settings can be made via jumper.
3.1 Technical data
Description Value
Supply voltage 24 V DC ±10%
Typical power consumption 200 mA
Outputs short circuit proof
Length x Hight x Depth (+x: zusätzlicher Abstand für Kabel) 65 x 99 x 35 (+40) mm
Bolt M3 x 20 mm
Installation depth 40 mm
Bezel cutout 72 x 72 mm; r = 3 mm
Temperature range: Storage & Transportation / Operation -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & Transportation / Operation
(non-condensing)
+5 – +95 % / +15 – +85 %
Service
1 2 4C
V
65
99
85 7
72
75
1 mm
2 mm
3 mm
50
7,5
Bezel cutout
corner radius: 3 mm
X3
X4
X6
X1
X2
P1
Fig. 3.1: EAZ-256/64_V2 Circuit board drawing

EAZ-256/64
Technicaldata
6 ManualEAZ-256
X3
X4 X6
Service
124CV
X2
X1
65
99
85 7
72
75
1 mm
2 mm
3 mm
50
7,5
Fig. 3.2: EAZ-256/64 Circuit board drawing
3.1.1 Terminal X3
The terminal X3 is used to connect landing control panel components when using EAZ-246/64 on landing contol
panel.
EAZ-256/64 X3 Function Technical details
1 + 24 V P
2 Landing call UP I/O; L 350 mA / 24 V
3 Landing call DOWN I/O; L 350 mA / 24 V
4 Landing call release O; L 350 mA / 24 V
5 Direction UP O; L 350 mA / 24 V
6 Direction DOWN O; L 350 mA / 24 V
7 +24 V P
8 Key switch 1 I; H
9 Key switch 2 I; H
10 GND P
11 No function at the moment from version 2.x
12 No function at the moment from version 2.x
EAZ-256/64 X4 Function
1 Gong loudspeaker + (8 Ohm)
2 Gong loudspeaker – (8 Ohm)
The terminals labelled with key switch 1 and key switch 2 can be factory-provided with the following functions:
re recall, smoke detector, remote shutdown and priority landing.
cornerradius3mm
Bezel cutout

EAZ-256/64
Technicaldata
ManualEAZ-256 7
3.1.2 Jumper
The service jumper JS is not plugged in.
Jumper JV: Installation position
Installation position V
horizontal („TOP-H“) open
vertical („TOP-V“) plugged
Jumper J3 – J5
FST allocation J3 J4 J5
FST A open open open
FST B plugged open open
FST C open plugged open
FST D plugged plugged open
FST E open open plugged
FST F plugged open plugged
FST G open plugged plugged
FST H plugged plugged plugged
Jumper J6: Installation location
Installation location J6
landing open
car plugged

EAZ-256/64.G
Technicaldataloudspeaker
8 ManualEAZ-256
4 EAZ-256/64.G
The EAZ-256/64.G has exactly the same functions as the EAZ-256/64. In addition, the delivery includes a suita-
ble loudspeaker, which is connected to the terminal EAZ-256/64.G X.
Please refer to the chapter 3 „EAZ-256/64“ on page 5 for description of technical data, pin assignment and
conguration.
4.1 Technical data loudspeaker
Description Value
Power 0,5 W
Impedance 8 Ohm
Diameter 50 mm
Installation depth 25 mm
55
65
48
48
Fig.4.1: Loudspeaker
4.2 Settings on the loudspeaker
The volume of the chime can be adjusted with the potentiometer P1 at the rear of the EAZ-256.64/G.

EAZ-256/64.FPM-2
Technicaldata
ManualEAZ-256 9
5 EAZ-256/64.FPM-2
The EAZ-256/64.FPM-2 is a low cost alternative to a LON position indicator. It hasn’t a separate LON nod
and can only be operated in connection with the car panel module FPM-2 (see manual of the FPM car panel
module).
The EAZ-256/64.FPM-2 has no jumpers or terminals. The position indicator EAZ-256/64.FPM-2 will be connec-
ted to FPM-2 (pin connector X5) with ribbon cable via 14-pin connector X5 (NEW-internal SPI-connection). The
display information is transmitted to position indicators by the ribbon cable.
Note:
The maximum length of the ribbon cable at the pin connector X5 may not exceed 1,0 m.
All settings such as an installation location of this position indicator and direction of the display picture (jumper
JV on the FPM-2) have to be made on the FPM-2.
The EAZ-256/64.FPM-2 will be delivered in a luminous eld type MA9999 with red window by SCHÄFER GmbH
including the ribbon cable that consists of 14 cores.
5.1 Technical data
Description Value
Supply voltage 24 V DC ±10%
Typical power consumption 100 mA
Length x Hight x Depth 143 x 108 x 35 mm
Bolt M3 x 12 mm
Installation depth 55 mm
Bezel cutout 99 x 99 mm; r = 2,8 mm
Temperature range: Storage & Transportation / Operation -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & Transportation / Operation
(non-condensing)
+5 – +95 % / +15 – +85 %
X6
X5
143
13,5
12
40
68
96
108
Fig. 5.1: EAZ-256/64.FPM-2 Circuit board drawing

Diagnostic assistance
Technicaldata
10 ManualEAZ-256
6 Diagnostic assistance
An interrupted LON connection
The display is functional, if the position indicator displays a luminous frame with a small square. However, the
connection to the LON-Bus is interrupted.
Fig. 6.1: Position indicator during a power supply and interrupted LON connection
Among others this may be due to one of the following reasons:
› Incorrect assignment of FST:
Check the jumpers J3, J4, J5 and the corresponding assignment of the FST-IDs
› The bus cable may be damaged:
Check the cable for proper operation. If necessary contact the service line.
› The FST may be faulty:
Check the controller for proper operation. If necessary contact the service line.
Display inspection
To make display pixel fault clear, you can carry out a function test of the EAZ.256 by inserting a special cable to
the EAZ.256 (only supply voltage, no LON connection). It can be obtained from NEW LIFT.
The position indicator displays the pattern from Fig. 6.1.
If jumper is changed in the switched-on state, the EAZ will switch to full screen mode a short time later. All
points of the display inspection will light up simultaneously.
Installation position
The installation position is not correct, if the square is at a different position. 90° corrections can be carried out
with the appropriate jumper V.
The EAZ must be turned accordingly, if the installation position can not be regulated using jumper settings.
Function
The yellow Service LED signals that the EAZ-256 in standby state. This is indicated by a short ash when the
power supply is switched on.
If the LED continues to ash or the LED lights permanently, it indicates an error.

Settings in the FST menu
Technicaldata
ManualEAZ-256 11
7 Settings in the FST menu
The options for the position indicators are set in the FST-Menu under MAIN MENUE - Config - EAZ Con-
figuration. The oor names displayed by the position indicator as well as various display options are set
here.
7.1.1 Setting floor names
› Set Config - EAZ Configuration - Use Text = YES.
› Enter a two-digit oor name for each oor in Config - EAZ Configuration - EAZ Text - Text
› Use key combination S+↑ or S+↓ to scroll through the oors.
7.1.2 Setting type of position indicator
Set the available type of position indicator used under Config - EAZ Configuration - LON-EAZ Type.
If different types of position indicators are installed in the system, the options of position indicators must be set
for each type successively:
› First select position indicator type
› Then set all options for the selected type
› Save
› Then select next position indicator type
› Repeat the procedure untill the options for all installed position indicator types are set
7.1.3 Setting options for position indicator
The position indicator options are set under MAIN MENU - Config - EAZ Configuration - LON-EAZ
Config.
If jumper J6 is open (display in landing panel), the following options are available in the FST Menu under
Config - EAZ Configuration - LON-EAZ Config.
The bits of parameter LON-EAZ Config have different meanings depending on the setting of parameter
Config - Departure Arrows:
Departure arrows = Ja
00000000
11 22 44 88
bit 0-2: 000: own floor as arrow, other floors as text
001: own floor as arrow, other floors dark
010: all floors as one digit text
011: all floors as text without arrows
100: own floor as arrow, other floors as text with direction arrow
101: displaying the Software Version as scrolling text
110: all floors as one digit text with direction and departure arrows
111: no departure arrow but direction arrow with departure function
bit 3: 0: static departure arrow
1: pulsing departure arrow
bit4: 0: Special Infos on
1: Special Infos off
bit 5: 0: Special Infos as graphic
1: Special Infos as scrolling text
bit 6: 0: Display „Special Drive“ on
1: Display „Special Drive“ off
bit 7: 0: Special Infos in German
1: Special Infos in English
The bits 0-3 are only operable, if jumper J6 is not plugged (Landing Indicator)!
For displaying the Software-Version (bit 0-2) a Reset is required!
Fig. 5.1: Conguration bits for departure arrows = Yes

Settings in the FST menu
Technicaldata
12 ManualEAZ-256
Departure arrows = No
00000000
11 22 44 88
bit 0-3: no function
bit 4: 0: Special Infos on
1: Special Infos off
bit 5: 0: Special Infos as graphic
1: Special Infos as text
bit 6: 0: Display „Special Drive“ on
1: Display „Special Drive“ off
bit 7: 0: Sonderanzeige-Text Deutsch
1: Sonderanzeige-Text Englisch
Fig. 5.2: Conguration bits for departure arrows = No

ManualEAZ-256 13

NEWLIFTSteuerungsbauGmbH
LochhamerSchlag8
82166Graefelfing
Tel +49 89 – 898 66 – 0
Fax +49 89 – 898 66 – 300
Mail [email protected]
Serviceline
Tel +49 89 – 898 66 – 110
Mail [email protected]
www.newlift.de
Table of contents