4rev. 1.3 03/05/2013
(reported by alternately flashing T. MOT PED Leds and T.
PAUSA Led), by using the SEL key to select the flashing CODE
LED, and then press the SET key. At this point the CODE LED
lights up steady and programming is finished.
Accordingly, using either the radio-control or the low voltage
push button panel to operate the gate, you will obtain the
following function: the first impulse controls opening until the
motor time expires, the second impulse controls gate closing. If
an impulse is sent before the motor time expires, the control
unit changes the direction of motion in the opening and closing
phases. Repeat the procedure if you wish to restore the
previous configuration.
B) PED. CODE ( Electronic Brake ) :
The control unit is supplied by the manufacturer with the
electronic brake function disabled. If you wish to enable the
function, proceed as follows: check that Extended Menu 1 is
enabled (T. MOT. PED and T. PAUSA LEDs start flashing
alternately), use the SEL button to move to the flashing PED
CODE LED then press the SET key: at that point the PED
CODE LED will light up steady and programming is complete.
Accordingly, the control unit slows down gate advancement by
inertia, when there is a stop or command to change the
direction of motion. Repeat the procedure if you wish to restore
the previous configuration.
C) INB. CMD. AP ( Anti-collision Function ) :
The control unit is supplied by the manufacturer with the Anti-
collision (pedestrian) Function disabled. If you wish to enable
the function, proceed as follows: check that Extended Menu 1
is enabled (T. MOT. PED and T. PAUSA Leds flash
simultaneously), use the SEL button to move to the flashing
INB. CMD. AP. LED and then press the SET button. At this
point the INB. CMD. AP. LED will light up steady and
programming is complete. The control unit will now operate in
Anti-Collision (pedestrian) mode.
If you wish to enable the Anti-Collision (pedestrian) function for
the closing phase only, repeat the operation described above,
pressing the SEL key twice (making the IN.CMD.AP. LED flash
quickly). Repeat the procedure if you wish to restore the
previous configuration.
D) LAMP/CORT. ( Deceleration ):
As mentioned above, it is possible to programme a
deceleration phase on the control unit for opening or closing,
whereas deceleration is automatically enabled with the
Automatic Programming function. If you do not wish to
implement any deceleration, it can be excluded: therefore, if
you are using Automatic Programming, the Deceleration phase
will not be enabled, whereas if you are using Motor Time
Programming, as you are programming you will not be given
the possibility of programming deceleration during the opening
and closing phases. If, prior to excluding deceleration, it was
programmed from the Motor Time Programming function, it will
be necessary to repeat programming all over again. If you wish
to exclude deceleration, proceed as follows: make sure
Extended Menu 1 is enabled (reported by T.MOT.PED and T.
PAUSA Leds flashing alternately). Using the SEL key, move to
the flashing LAMP/CORT. LED and then press the SET key:
the LAMP/CORT. will turn off definitely and programming will be
complete. Repeat the procedure if you wish to restore the
previous configuration.
E) PGM. AUT. ( Follow Me ) :
It is possible to set the "Follow Me" function on the control unit:
this function can only be programmed if a Pause Time has
already been programmed, and it is used to shorten the Pause
time to 5 sec after the photocell disengages, i.e. the gate
closes 5 seconds after the user has passed through. If you
wish to enable the function, proceed as follows: check that
Extended Menu 1 is enabled (T. MOT. PED and T. PAUSA
Leds flash simultaneously), use the SEL button to move to the
flashing PGM. AUT. LED and then press the SET key: the
PGM. AUT. LED will light up steady and programming is
complete. Repeat the procedure if you wish to restore the
previous configuration.
F) T. MOT. ( ENCODER ) :
The control unit supplied by the manufacturer can manage
Motors with a point Encoder; in the default configuration,
Encoder point control is disabled. If you wish to enable the
control, proceed as follows: check that Extended Menu 1 is
enabled (T. MOT. PED and T. PAUSA LEDs start flashing
alternately), use the SEL button to move to the flashing T.
MOT. LED then press the SET key: at that point the T. MOT
LED will light up steady and programming is complete. Repeat
the procedure if you wish to restore the previous configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the functions described in Extended Menu
2, proceed as follows: access Extended Menu 1 (as described
in the relative paragraph), then press and hold the SET button
down again for 5 seconds, after which amount of time the T.
MOT. PED and T. PAUSA LEDs will start flashing
simultaneously. The user then has 30 seconds to select the
functions for Extended Menu 2 using the SEL and SET buttons.
After another 30 seconds the control unit will go back to the
main menu.
---------------------- EXTENDED MENU 2 -----------------
Led Reference Led Off Led On
A) CODE remote PGM = OFF remote PGM = ON
B) PED. CODE Photocell Test = OFF Photocell Test= ON
C) IN.CMD.AP. Sens1 = rev. in CH Sens1 = brief rev. AP/CH
D) LAMP/CORT.Sens2 =stop AP/CH Sens2 = brief rev. AP/CH
E) PGM. AUT. PUL=PUL –BL=BL PUL=AP - BL=PED
F) T.MOT. PUL=PUL –BL=BL PUL=AP - BL=CH
G) T. MOT. PED. Simultaneous ON/OFF flashing
H) T. PAUSA Simultaneous ON/OFF flashing
A) CODE ( Remote radio-control programming ) :
The control unit allows the transmission code to be
programmed, without using the SEL button directly on the
control unit, but remotely.
The Radio-control can be remotely programmed as follows:
continuously sending a previously-memorised radio-control
code for more than 10 seconds. At this point the control unit
switches to programming mode, as described above for the
CODE LED in the main menu.
The control unit is factory supplied with the remote
transmission code programming function disabled. If you wish
to enable the function, proceed as follows: check that Extended
Menu 2 is enabled (T. MOT. PED and T. PAUSA LEDs flash
simultaneously), use the SEL button to move to the flashing
CODE LED, then press the SET key: at this point the CODE
LED will light up steady and programming is complete. Repeat
the procedure if you wish to restore the previous configuration.
B) CODE PED. (Photocell Test) :
The control unit is factory supplied with Photocell Test
programming disabled. If you wish to enable the function (in
accordance with Standard EN 12453), proceed as follows:
check that Extended Menu 2 is enabled (T. MOT. PED and T.
PAUSA Leds flash simultaneously), use the SEL button to
move to the flashing CODE PED. LED then press the SET key:
at this point the CODE PED. LED will light up steady and
programming is complete. Accordingly, the Safety Device test
will be carried out before the automation starts any type of
motion. Repeat the procedure if you wish to restore the
previous configuration. When the Safety Device inputs are not
in use they must be jumpered and the Photocells Test
deactivated.
C) IN.CMD.AP. ( Sensor 1 Operating Logic) :
The control unit is factory supplied with the following operating
logic installed for Sensor 1 operation: it is not considered if it is
triggered in the opening phase, whereas in the closing phase it