Next 07-01 User manual

Ultrasound Gel
Packet Warmer
Instrucons for Use
Thank you for purchasing the
industry’s rst gel packet warmer,
carefully designed for both clinical
sasfacon and paent comfort.
Versale: Now tested for
warming gel in boles too!
70203C
NEXT Medical Products Company, 45 Columbia Road, Branchburg, NJ 08876 USA
800-458-4254 | 908-722-4549 | Fax: 908-218-3715
customerservice@nextmedicalproducts.com | www.nextmedicalproducts.com
REF
07-01
Features:
• Part Number: 07-01
• Dimensions: 10” L x 7” W x 5.5” H
• Three preset temperature sengs: 95°F (35°C), 100°F (38°C), 105°F (41°C)
• Programmable feature allows preset temperatures to be lowered if desired
• Holds 35 – 40 ultrasound gel packets or accommodates up to 3 ultrasound gel
boles
• Electrical requirements: 110V AC 60hz power outlet (will automacally work
with all AC power standards 100/240VAC 50/60Hz)
Precauons:
• Use the warmer on a at, stable surface to avoid pping or danger of falling.
• To protect against electric shock, do not immerse the unit or the plug in
liquids.
• The warmer was designed for ultrasound gel packets and boles. Do not place
foreign objects inside warmer.
Cercaons:
• UL listed
• Safety Standards: UL 60950-1, TUV EN60950-1, EAC TP TC 004
• Withstand Voltage: I/P-O/P:3KVAC
• Isolaon Resistance: I/P-O/P:100M Ohms/500VDC/25°C/70%RH
• EMC Emission: EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
• EMC Immunity: EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level
(surge L-N:1KV), criteria A, EAC TP TC 020
Warranty:
Two year limited warranty from date of purchase. Product found to be defecve
upon receipt will be repaired or replaced at our discreon at no charge. This
warranty does not include damage or failure due to use, misuse, neglect, shipping,
or if product is not stored or handled in accordance with our recommendaons.
Storage:
• Recommended storage temperature: 32°F to 105°F (0°C to 41°C)

Features:
• Choice of three temperature sengs. Reprogrammable if desired.
• User-friendly interface that can be toggled with the push of a buon.
• Proprietary warming controls to maintain a consistent temperature
throughout the day.
• Built-in safety feature to prevent the warmer from reaching temperatures
above the selected seng.
• Internal LED to illuminate the digital display and to allow the user to quickly
verify warmer temperature
How to Use:
Carefully unpack the warmer and AC power cord. Place the warmer on a at, dry
surface such as a stable counter or desktop. Connect the cord to the back of the
warmer. Plug the other end of the cord into a standard 110V AC 60hz power outlet.
Once plugged in, the warmer is on and ready for use.
Open the hinged lid and load the Clear Image Singles® Ultrasound Gel Packets (or
other brand) into the warmer’s packet holding cavity. Reclose the lid to maintain
the temperature of the warmer and to keep dust and foreign objects out.
Oponally, place up to three ultrasound gel boles (with lids securely closed)
horizontally in the holding cavity. This posion warms the gel throughout the enre
bole, not solely the boom.
Once the unit is plugged in, it defaults to the Low seng and remains on the Low
seng unl the user selects a dierent temperature. To select the desired warmer
temperature, use the three buons located underneath the lighted display.
Ultrasound Gel Packet Warmer
Aer pressing a temperature buon the lighted display will show the temperature
you selected. The temperature seng remains in eect unl another temperature
buon is pressed or the unit is turned o. When the cavity is fully loaded, the
warmer will reach the selected temperature within two hours and maintain that
temperature while the unit is on.
The Warmer uses real-me temperature sensing. This technology enables the user
to verify the temperature of the internal sensor at any me. This may be helpful, in
instances when the warmer has been plugged in for less than 2 hours and the user
wants to know how close the warmer is to the intended set temperature. To check
the temperature, simply press the buon of your current temperature seng. For
example, if your unit is set to warm to 100°F, press the middle buon again and the
screen will momentarily display the warmer’s current temperature.
LEFT BUTTON: Low, 95°F (35°C)
MIDDLE BUTTON: Medium, 100°F (38°C)
RIGHT BUTTON: High, 105°F (41°C)
When ready to use gel, li the lid of the warmer, remove a packet (or bole)
and reclose the lid. It is recommended to check that the warmth of the gel is as
expected before applying to paent’s skin.
To turn o the warmer, simply unplug from the outlet.
Cleaning:
The Ultrasound Gel Warmer has a curved outer design to aid in cleaning and
disinfecng. The gel-holding cavity does not contain seams, hard corners or sharp
edges that might harbor bacteria or hinder cleaning eciency and eecveness.
Before cleaning, empty the warmer and make sure the warmer is unplugged and
cooled down. Use a quaternary cleaning wipe (such as SONO® Ultrasound Wipes)
to make contact with every surface inside the warmer’s packet holding cavity.
Wipe down the lid and the outside of the unit, being careful to avoid the electrical
outlet area. In lieu of cleaning wipes, use a mild detergent on a slightly damp cloth.
When cleaning is completed, allow the unit to air dry before plugging it back in and
relling it with gel packets.
Troubleshoong:
• If the digital display does not illuminate, conrm the plug is rmly pushed into
the electrical outlet and ensure the outlet has power.
• If gel does not feel warm enough, make sure the device is powered on. Try
using a higher temperature seng. Select gel closer to the boom of the
cavity. When rst plugging in the unit, allow two hours to reach the selected
temperature.
• If the gel feels too warm, try the lowest temperature seng or refer to the
programmable feature to congure your own temperature sengs.
For addional quesons or concerns, contact NEXT Medical Products or your
distributor.
Programmable Feature:
If desired, the default temperature sengs are programmable and can be
decreased by following these steps:
1) Hold the Lemost Buon for 5 seconds - release when you see the screen
display P0.
2) Using the middle buon to scroll up or the rightmost buon to scroll down,
press unl locang one of the P values listed below.
P7 - Lowest seng P8 - Mid seng P9 - High seng
3) When the desired P value is showing on the display, quickly press the
lemost buon. Then, change the P value’s temperature seng by scrolling
up with the rightmost buon or down using the middle buon. Aer
reaching the desired number, wait approximately ve seconds for the
warmer to reset to the new temperature seng.
Repeat steps 1 - 3 to change another P value.
Popular Food Warmer manuals by other brands

Hatco
Hatco HYDRO-HEATER FR2-3 Installation and operating manual

Hatco
Hatco FR-3 Replacement parts list

Metro DataVac
Metro DataVac C5 1 Series Instructions for use

Nemco
Nemco 6120A Operating and maintenance instructions

True
True TA1HRI-1S Specifications

Earthlite
Earthlite UV Hot Towel Cabinet Mini user manual