Wells M227 Series User manual

WELLS MANUFACTURING
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wellsbloomfield.com
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
OWNERS MANUAL
BUILT-IN WELL
MODULAR
WARMERS
with
INFINITE,
THERMOSTAT or DIGITAL
CONTROLS
MODELS
M200, M227, MOD200, MOD227
M300, M327, MOD300, MOD327
M400, M427, MOD400, MOD427
M500, M527, MOD500, MOD527
Includes
INSTALLATION
USE & CARE
EXPLODED VIEW
PARTS LIST
WIRING DIAGRAM
011C
p/n 2M-Z16298 Rev. (C) M011C.02 150217
MOD-200T
MOD-200TDN

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
Unless otherwise specied, all commercial cooking
equipment manufactured by Wells Manufacturing is
warranted against defects in materials and workmanship
for a period of one year from the date of original installation
or 18 months from the date of shipment from our factory,
whichever comes rst, and is for the benet of the original
purchaser only.
THIS WARRANTY IS THE COMPLETE AND ONLY
WARRANTY, EXPRESSED OR IMPLIED IN LAW
OR IN FACT, INCLUDING BUT NOT LIMITED TO,
WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR ANY PARTICULAR PURPOSE, AND/OR FOR
DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES
IN CONNECTION WITH WELLS PRODUCTS. This
warranty is void if it is determined that, upon inspection
by an authorized service agency, the equipment has been
modied, misused, misapplied, improperly installed, or
damaged in transit or by re, ood or act of God. It also
does not apply if the serial nameplate has been removed,
or if service is performed by unauthorized personnel. The
prices charged by Wells Manufacturing for its products are
based upon the limitations in this warranty. Seller’s obligation
under this warranty is limited to the repair of defects without
charge by a Wells Manufacturing factory authorized service
agency or one of its sub-service agencies. This service will
be provided on customer’s premises for non-portable models.
Portable models (a device with a cord and plug) must be
taken or shipped to the closest authorized service agency,
transportation charges prepaid, for service. In addition to
restrictions contained in this warranty, specic limitations are
shown in the Service Policy and Procedure Guide. Wells
Manufacturing authorized service agencies are located in
principal cities. This warranty is valid in the United States and
Canada and void elsewhere. Please consult your classied
telephone directory, your foodservice equipment dealer or
contact:
Wells Manufacturing
10 Sunnen Dr., P.O.Box 430129 St. Louis MO 63143 USA
phone (636) 678-6314 or fax (314) 781-2714
for information and other details concerning warranty.
LIMITED WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
NOTE: For your protection, please note that equipment
in this shipment was carefully inspected and packaged
by skilled personnel before leaving the factory. Upon
acceptance of this shipment, the transportation company
assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill or
express receipt, and that the note of loss or damage is
signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and le
“CONCEALED DAMAGE” claim with them. This
should be done within fteen (15) days from the date
the delivery was made to you. Be sure to retain the
container for inspection.
Wells Manufacturing cannot assume liability for damage or
loss incurred in transit. We will, however, at your request,
supply you with the necessary documents to support your
claim.
SHIPPING DAMAGE CLAIM PROCEDURE
1. Resetting of safety thermostats, circuit breakers, over
load protectors, and/or fuse replacements are not
covered by this warranty unless warranted conditions
are the cause.
2. All problems due to operation at voltages or phase
other than specied on equipment nameplates are
not covered by this warranty.
Conversion to correct voltage and/or phase must be
the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements
and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to
include such items as knobs, light bulbs; and, normal
maintenance functions including adjustments of
thermostats, adjustment of micro switches and
replacement of fuses and indicating lights are not
covered by warranty.
5. Damage to electrical cords and/or plug due to exposure
to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied
with each machine. Noted maintenance and
preventative maintenance items, such as servicing
and cleaning schedules, are customer responsibility.
Those miscellaneous adjustments noted are customer
responsibility. Proper attention to preventative
maintenance and scheduled maintenance procedures
will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an
Authorized Service Agency or one of its sub-service
agencies.
8. All labor shall be performed during regular working
hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for
ninety (90) days from date of purchase on non-warranty
equipment. This parts warranty is limited only to
replacement of the defective part(s). Any use of non-
genuine Wells parts completely voids any warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this
warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to
perform service are not covered by warranty. This
includes institutional and correctional facilities.
xi

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
WARRANTY xi
SPECIFICATIONS 1 - 3
FEATURES & OPERATING CONTROLS 4
PRECAUTIONS & GENERAL INFORMATION 5
AGENCY LISTING INFORMATION 5
INSTALLATION 6
OPERATION 8
CLEANING INSTRUCTIONS 10
TROUBLESHOOTING SUGGESTIONS 12
MAINTENANCE INSTRUCTIONS 13
MODEL NUMBER IDENTIFICATIONS 14
EXPLODED VIEW & PARTS LIST 15 - 25
WIRING DIAGRAM 26 - 35
PARTS & SERVICE 36
CUSTOMER SERVICE DATA 37
Thank You for purchasing this Wells Manufacturing appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it
gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for the
appliance in a manner which will ensure its optimum performance.
TABLE OF CONTENTS
INTRODUCTION
SPECIFICATIONS (Innite)
MODEL VOLTS WATTS AMPS 3ø AMPS1ø
L1 L2 L3
MOD200, D, DM 208V 1800W - - - 8.7A
240V 2400W - - - 10.0A
MOD300, D, DM 208V 2700W 7.5A 7.5A 7.5A 13.0A
240V 3600W 8.7A 8.7A 8.7A 15.0A
MOD400, D, DM 208V 3600W 11.2A 11.2A 7.5A 17.3A
240V 4800W 13.0A 13.0A 8.7A 20.0A
MOD500, D, DM 208V 4500W 15.0A 11.2A 11.2A 21.6A
240V 6000W 17.0A 13.0A 13.0A 25.0A
1

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
SPECIFICATIONS (Thermostat)
2
MODEL VOLTS WATTS AMPS 3ø AMPS1ø
L1 L2 L3
MOD-200T 208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
MOD-200TD
MOD-200TDM 240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD-200TDM-K 208 VAC 2480W 6.0A 6.0A 10.3A 11.9
240 VAC 3300W 6.9A 6.9A 11.9A 13.8
MOD-200TN 208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
MOD-200TDN
MOD-200TDMN 240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD-227TD 208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
MOD-227TDM 240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD-300T 208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
MOD-300TD
MOD-300TDM 240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD-300TN 208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
MOD-300TDN
MOD-300TDMN 240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD-327TDM 208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD-400T 208 VAC 4960W 14.5A 14.5A 9.8A 23.8A
MOD-400TD
MOD-400TDM 240 VAC 6600W 17.8A 17.8A 11.3A 27.5A
MOD-427TDM 208 VAC 4960W 14.5A 14.5A 9.8A 23.8A
240 VAC 6600W 17.8A 17.8A 11.3A 27.5A
MOD200TDM/AF,
MOD200TDAF
208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD200TDMN/AF 208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD227TDM/AF 208 VAC 2480W 6.0A 6.0A 10.3A 11.9A
240 VAC 3300W 6.9A 6.9A 11.9A 13.8A
MOD300TDM/AF,
MOD300TDAF
208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD300TDMN/AF/F6 208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD327TDM/AF 208 VAC 3725W 10.3A 10.3A 10.3A 17.9A
240 VAC 4950W 11.9A 11.9A 11.9A 20.6A
MOD400TDM/AF,
MOD400TDAF
208 VAC 4960W 14.5A 14.5A 9.8A 23.8A
240 VAC 6600W 17.8A 17.8A 11.3A 27.5A
MOD427TDM/AF 208 VAC 4960W 14.5A 14.5A 9.8A 23.8A
240 VAC 6600W 17.8A 17.8A 11.3A 27.5A
MOD500TDM/AF,
MOD200TDAF
208 VAC 6200W 19.5A 14.6A 14.6A 29.8A
240 VAC 8250W 22.1A 16.9A 16.9A 34.4A
MOD527TDM/AF 208 VAC 6200W 19.5A 14.6A 14.6A 29.8A
240 VAC 8250W 22.1A 16.9A 16.9A 34.4A

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
SPECIFICATIONS (Digital)
MODEL VOLTS WATTS AMPS 3ø AMPS1ø
L1 L2 L3
M200CE
208/240V 2,475 / 3,312 6.0 / 6.9 6.0 / 6.9 10.3 / 11.9 11.9 / 13.8
M200E
M200CED
M200ED
M200CED6
M200ED6
M200CEDM
M200EDM
M200CEDM6
M200EDM6
M200CEAF
M200EAF
M200CEAF6
M200EAF6
M227CEDM
M227EDM
M227CEDM6
M227EDM6
M227CEAF
M227EAF
M227CEAF6
M227EAF6
M300E
208/240V 3, 733 / 4,944 10.3 / 11.9 10.3 / 11.9 10.3 / 11.9 17.9 / 20.6
M300E6
M300EAF
M300EAF6
M300ED
M300ED6
M300EDM
M300EDM6
M327EAF
M327EAF6
M327EDM
M327EDM6
M300EAFTH 208/240V 2,704 / 3,600 7.5 / 8.7 7.5 / 8.7 7.5 / 8.7 13 / 15
M400E
208/240V 4,950 / 6,600 14.5 / 17.8 14.5 / 17.8 9.8 / 11.3 23.8 / 27.5
M400E6
M400EAF
M400EAF6
M400ED
M400ED6
M400EDM
M400EDM6
M427EAF
M427EDM
M427EDM6
M500E
208 / 240V 6,198 / 8,256 19.5 / 22.1 19.5 / 22.1 19.5 / 22.1 29.8 / 34.4
M500E6
M500EAF
M500EAF6
M500ED
M500ED6
M500EDM
M500EDM6
M527EAF
M527EAF6
M527EDM
M527EDM6
3

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
FEATURES & OPERATING CONTROLS
A. THERMOSTAT
1. On thermostatically controlled warmers, power is applied to the
heating element according to the control knob position and the actual
temperature at the temperature sensing thermobulb.
2. The desired temperature is controlled by rotating the temperature
control knob. The knob has a numeric scale, where higher numbers
correspond to higher temperature.
3. On warmers equipped with an indicator light, the light will glow when
the thermostat is calling for heat (i.e. the element is energized).
4. The TEMPERATURE CONTROL KNOB will rotate approximately 300º,
and will reach a “stop” at both ends.
The OFF position is marked.
NOTE: The dial position is an indication of the temperature setting. Actual
temperature will vary depending upon the type of product and food
consistency.
A. INFINITE SWITCH
1. On INFINITE SWITCH CONTROLLED warmers, power is applied to
the heating element based on the control knob position, which varies
the duty cycle of the heating element.
2. The desired temperature is controlled by rotating the TEMPERATURE
CONTROL KNOB. The knob may have a numeric scale, where
higher numbers correspond to higher temperature. LO is the lowest
temperature setting; PREHEAT is a “continuous on” setting. Innite
switch controlled warmers are equipped with a hi-limit device to prevent
overheating. The hi-limit will self-reset after the warmer has cooled.
3. On warmers equipped with an INDICATOR LIGHT, the light will glow
when the innite switch is in any position other than OFF.
4. The TEMPERATURE CONTROL KNOB will rotate without stopping,
with PREHEAT and OFF having obvious detents.The OFF position is a
“positive” OFF (i.e. the switch is positively held in the open position).
NOTE: An innite switch controls temperature by varying the ratio of “on”
time to “off” time. Thus, no temperature sensing devise is required.
B. MOUNTING
1. MOD-series built-in warmers may are equipped with wellsloks, uniquely
designed turnout tabs which help secure the warmer top ange to the
countertop.
2. See the Installation Instructions, supplied with the particular appliance.
C. DRAINS
1. Models wih a “D” (e.g. M200TD) have drains for each pan, with each
pan having an individual drain valve.
2. Models with a “DM” units (e.g. M200TDM) have the individual drain lines
manifolded together, with a single drain valve for the entire manifold.
D. AUTOFILL
1. On AUTOFILL units, water level is automatically fed into the
“master” pan whenever that pan’s thermostat is ON .
2. Water level is sensed by a WATER LEVEL PROBE in the “master” pan.
INDICATOR
LIGHT
TEMPERATURE
CONTROL
KNOB
IL2468
IL2469
WELLSLOKS
IL2524
WATER LEVEL
SENSOR
WATER LEVEL
IMPORTANT:
DO NOT LEAVE ON
“PREHEAT”
Unit may cycle on hi-limit
control, leading to premature
failure of the hi-limit controls
device.
4

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
PRECAUTIONS AND GENERAL INFORMATION
E6070
AGENCY LISTING INFORMATION
Refer to the product nameplate for the specic appliance for agency
listings. In general:
This appliance conforms to NSF Standard 4 for sanitation only if
installed in accordance with the supplied Installation Instructions.
UL Listed warmers are U Listed under UL File E6070.
STD 4
UL Listed Warmers
WARNING:
SHOCK HAZARD
All servicing requiring
access to non-insulated
electrical components must
be performed by a factory
authorized technician.
DO NOT open any access
panel which requires the use
of tools. Failure to follow this
warning can result in severe
electrical shock.
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize
this appliance until all
installation instructions are
read and followed. Damage
to the appliance may result
if these instructions are not
followed.
CAUTION:
HOT SURFACE
Exposed surfaces
can be hot to the touch and
may cause burns.
This appliance is intended for use in commercial establishments only.
This appliance is intended to hold pre-heated food for human
consumption. No other use is recommended or authorized by the
manufacturer or its agents.
Operators of this appliance must be familiar with the appliance use,
limitations and associated restrictions. Operating instructions must be
read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and
follow all included cleaning instructions and schedules to ensure the
safety of the food product.
Disconnect this appliance from electrical power before performing any
maintenance or servicing.
This appliance is not jet stream approved. Do not direct water jet
or steam jet at this appliance, or at any control panel or wiring. Do
not splash or pour water on, in or over any controls, control panel or
wiring.
Exposed surfaces of this appliance can be hot to the touch and may
cause burns.
Do not operate this appliance if the control panel is damaged. Call
your Authorized Wells Service Agent for service.
The technical content of this manual, including any wiring diagrams,
schematics, parts breakdown illustrations and/or adjustment
procedures, is intended for use by qualied technical personnel.
Any procedure which requires the use of tools must be performed by a
qualied technician.
This manual is considered to be a permanent part of the appliance.
This manual and all supplied instructions, diagrams, schematics,
parts breakdown illustrations, notices and labels must remain with the
appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this
appliance has American sizes on all hardware.
5

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
NOTE: DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation. Refer to
SHIPPING DAMAGE CLAIM
PROCEDURE on the inside
front cover of this manual.
WARNING:
RISK OF INJURY
Installation procedures must
be performed by a qualied
technician with full knowledge
of all applicable electrical and
plumbing codes. Failure can
result in personal injury and
property damage.
CAUTION
FIRE HAZARD
Avoid storing ammable or
combustible materials in, on or
near the appliance.
IMPORTANT: For warmers
installed in plastic counter
tops, the counter material
must be protected from the
heat of the warmer in order to
prevent discoloration and/or
deterioration. Wellsloks are
not suitable for this purpose.
The installer should contact
the manufacturer or distributor
of the countertop material for
specic instructions.
IMPORTANT: Wellslok
Extension Kits must be
used ONLY with UL Listed
warmers approved for
installation in wood counter
tops. Refer to the Installation
Instructions provided with the
warmer.
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic lm, packing materials and accessories from the Appliance
before connecting electrical power or otherwise performing any
installation procedure.
Carefully read all instructions in this manual and the Installation
Instruction Sheet packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the unit.
Carefully account for all components and accessories before discarding
packing materials. Store all accessories in a place for later use.
INSTALLATION NOTES
1. Installation and start up of built-in warmers MUST be performed
by an authorized installation company.
2. It is the responsibility of the installer to verify that this warmer
installation is in compliance with the specications listed in this
manual and on the specication sheet provided.
3. It is the RESPONSIBILITY OF THE INSTALLER to check with
the authority having jurisdiction, in order to verify that this warmer
installation is in compliance with local code requirements.
4. Water supply and drain installation must meet all applicable
local, state and federal plumbing codes and ordinances.
5. Refer to Installation Instructions included with the warmer for
Underwriters Laboratories conditions of acceptability, electrical
requirements and other installation concerns.
BUILT-IN WARMERS
1. This is a GENERAL GUIDE. For specic cutout dimensions
and other installation details, refer to the Installation Instructions
supplied with the warmer.
2. Cutout dimensions for warmer units and control panels are listed
on the Installation Instructions provided with the warmer.
NOTE: Cutout dimensions are different for auto-ll and non auto-ll
units, control panels, and for wood and metal counters. Verify the
dimensions are correct for the installation before making the cutout.
Specic cutout specications are list on the installation sheet included
with the unit.
3. For “top-mounted” warmers (i.e. warmers mounted from above the
counter top):
a. Verify that provided sealants are applied to the underside of the
warmer top ange prior to setting the unit into the cutout.
b. After installation, verify that the tabs on the Wellsloks are turned
out to lock the warmer into the counter.
c. Apply a thin bead of food-grade silicone sealant around the ange
to seal it to the counter.
d. Wellslok extension kits are available for installing warmers in
counter tops where the standard Wellslok would not normally
reach. The extension kit will adapt to counter tops up to 1¾” thick.
INSTALLATION
6

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
INSTALLATION
ELECTRICAL INSTALLATION
1. Refer to the product nameplate. Verify the electrical service
power. Voltage and phase must match the nameplate
specications. Wiring the warmer to the wrong voltage can
severely damage the unit or cause noticeably decreased
performance.
2. Available electrical service amperage must meet or exceed the
specications listed on the specication sheet provided with the
warmer.
3. Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked “GND” or
” “ .
NOTE: Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specications of local codes and of the National Electrical
Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1. IMPORTANT: All plumbing installations must be performed by
a qualied plumber.
2. For units equipped with a DRAIN LINE: Some jurisdictions may
require an approved air gap or other back-ow prevention device
in the drain. It is the responsibility of the plumber to determine
such requirement, to provide and properly install the required
device.
3. AUTOFILL units are equipped with a DRAIN LINE: Some
jurisdictions may require an approved air gap or other back-
ow prevention device in the drain. It is the responsibility of the
plumber to determine such requirement, to provide and properly
install the required device.
4. For AUTOFILL units: Some jurisdictions may require an
approved back-ow preventer in the water supply line. It is the
responsibility of the plumber to determine such requirement, and
to provide and properly install the required device.
Autoll supply must be connected to a COLD WATER line only.
IMPORTANT:
While local plumbing codes may allow the use of pcv, cpvc, abs or
other plastic pipe for drain connections. DO NOT attach a plastic
drain to the bottom of the food warmer. These units will contain water
with temperatures in excess of 180°F (82°C) and localized metal
temperatures in excess of 275°F (135°C). Failure to follow these
directions may result in personal injury and property damage.
NOTE: Damage caused
by leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT: Contact a
licensed electrician to install
and connect electrical power
to the appliance.
IMPORTANT: Damage due to
being connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT: Electrical
installation other than as
specied on the specication
sheet will void the UL listing,
and may void the warranty.
NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.
7

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
OPERATION
WET OR DRY OPERATION for WARMERS
1. Carefully read the description of the warmer operation on the
specication sheet.
2. a. Most warmers are designed for WET OR DRY operation.
b. Warmers may be used wet, or may be used dry. However
warmers may NOT be used wet-to-dry or dry-to-wet unless
they have been allowed to cool to room temperature between the
change in wet or dry operation.
c. Wells Manufacturing recommends operating WET for consistent
food heating.
d. If your wet-operation warmer is allowed to run dry, turn it
OFF and allow to cool to room temperature before adding water.
3. If the warmer is to be used for WET operation, add approximately 1” of
hot tap water before turning the warmer on. Use of hot water will allow
a faster preheat.
a. Check the water level frequently and add hot water as necessary
to prevent the warmer from running dry. Do not add water to the
warmer if it has run dry.
b. If your wet-operation warmer is allowed to run dry, turn it OFF and
allow to cool to room temperature before adding water.
4. Damage caused by allowing a wet-operation warmer to run dry,
is NOT covered by warranty. Damage caused by adding water
to a dry warmer when hot is NOT covered by warranty.
PRE-HEATING THE WARMER
1. Place desired pan(s) or inset(s) with appropriate adapter top on warmer.
a. Insets are available as accessories in 2½ qt., 4qt., 7 qt., and 11 qt.
sizes with lids and adapter tops.
b. For dry operation, a 6” deep pan or inset is recommended.
2. Turn temperature control to HI or highest temperature setting.
3. Allow warmer to preheat for approximately 30 minutes, then set
the control for the desired temperature. Be sure to keep the warmer
covered during preheat and operation.
AUTOFILL WARMERS
1. Autoll warmers sense water level by a sensor placed at the proper
level. For manifolded autoll warmers, the water level sensor / ll tube
is in one pan only, normally in the far left pan.
2. Water lls the pan through an inlet tube. For manifolded autoll
warmers, the ll tube is normally in the far left pan. All other sections ll
at the same time through the drain manifold.
3. The autoll function is active only when the thermostat for the pan with
the water level sensor is turned ON .
4. Make sure the drain valve is fully closed before turning any t-stats ON.
5. The autoll function is only activated when the far left thermostat is
turned ON. For manifolded autoll warmers, be sure to turn far left
thermostats ON before turning any other control ON, to avoid heating a
dry pan.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
onto control panel or wiring.
Always use an inset.
DO NOT place food directly
into the warmer.
Always pour hot water into the
warmer before it is preheated.
DO NOT pour water into a
dry, heated warmer. This may
damage the unit.
DO NOT put ice into a
warmer pan. This will cause
condensation on the inside of
the warmer. Damage caused
by condensation is NOT
covered by warranty.
Stir thick food items frequently
to keep food heated uniformly.
Keep insets covered to
maintain food quality and
temperature.
DO NOT use AUTOFILL
warmers in the dry mode.
This may damage the water
level sensor. NEVER turn the
thermostat ON for the pan
with the sensor and ll tube
unless the entire warmer unit
is to be used in the wet mode.
IL2524
WATER LEVEL
SENSOR
WATER LEVEL
8

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
9
OPERATION (continued)
AUTOFILL WARMERS continued
6. DO NOT use autoll warmers in the dry mode. This may damage the water
level sensor probe. NEVER turn the thermostat ON for the pan with the
probe and ll tube unless the entire warmer unit is to be used in the wet
mode.
7. Clean water level sensor daily to maintain water level in warmer.
OPERATION
1. Always use an inset. DO NOT place food directly into the warmer.
2. Check water level in wet-operation warmer frequently during use. Running
warmers dry will lower the temperature of the food in the insert pan, and may
damage the warmer.
3. Alternating between wet and dry operation in any individual warmer is NOT
recommended.
4. DO NOT use metal tools, steel wool, or caustic or abrasive cleanser to clean
warmer pan.
WARMERS WITH MANIFOLDED DRAIN
1. Manifolded warmers have a single drain valve.
2. Water poured into any one section will seek the same water level with all
sections on the manifold.
3. Make sure the drain valve is fully closed before lling warmer.
Digital Control Operation
This control will provide close regulation of the temperature in the basin and
give an indication of the air temperature surrounding the food container. The
temperature is adjustable from 100° to 200°F. Pressing the ON/OFF button of
the temperature control activates the heating circuit. The setpoint is displayed
by pressing and holding the TEMP button. Adjust the regulated temperature
by pressing the + or – buttons while holding the TEMP button down. The
actual basin temperature is displayed when no buttons are pressed and the
control is in the ON mode. The dot in the lower corner of the display indicates
when the control is calling for heat.
When provided the master power switch controls the heating circuit and the
automatic water ll ocntrol. Turn “OFF” the power switch when draining or
cleaning the unit.
IL2525
Power
Switch
On/Off
Button Up
Temp
Display
Temp Down
ABOVE: Digital Electronic Control Panel (certain models only)

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
DAILY CLEANING INSTRUCTIONS
PREPARATIONS: Turn control knob(s) to OFF. Allow warmer to cool
before proceeding.
Remove any insets, pans and/or adapter tops.
Drain or remove water from well if used for
wet operation.
FREQUENCY: Minimum - daily.
TOOLS: Mild Detergent
Solution: 10 Parts Warm Water to 4 Parts Vinegar
Plastic Scouring Pad
Clean Cloth or Sponge
Food-Grade Silicone Sealant
1. Wipe entire unit down using a clean cloth or sponge and mild
detergent.
2. Use a plastic scouring pad to remove any hardened food particles
or mineral deposits.
IMPORTANT: DO NOT use steel wool for cleaning.
3. Rinse warmer thoroughly with a vinegar and water solution to neutralize
all detergent cleanser residue.
4. Inspect warmer ange-to-counter seal. Reseal with food-grade silicone
sealant if necessary. Failure to do so may allow grease and water to
leak into insulation and heating element, causing a potential re and/or
electric shock hazard.
5. Inspect warmer tank for damage. Damage to the outer body may
allow grease and water to leak into insulation and heating element,
causing a potential re and/or electric shock hazard. Contact your
Authorized Wells Service Agency to inspect warmer if water or grease
contamination is suspected.
6. Close drain valve. Add proper amount of warm water. Turn control
knob(s) ON and check for proper operation.
CLEANING INSTRUCTIONS
10
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
into or over any control panel
or wiring.
CAUTION:
SHOCK HAZARD
Disconnect warmer from
electric power before cleaning
CAUTION:
BURN HAZARD
Allow warmer to cool
completely before cleaning.

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
CLEANING INSTRUCTIONS
11
WEEKLY CLEANING INSTRUCTIONS
PREPARATIONS: Remove any insets, pans and/or adapter tops.
Drain or remove water from well if used for wet
operation.
FREQUENCY: Weekly, or whenever lime or scale is seen
accumulating on the sides of the warmer pans.
TOOLS: Commercial Delime Cleaner
Plastic Scouring Pad
Clean Cloth or Sponge
1. Add water to pans until water is at normal operating level
(1” - 1 1/2” deep) or covers accumulated scale.
2. Heat water to maximum temperature (190ºF or higher).
3. Pour contents of one package of commercial delime cleaner
into each warmer pan. Stir to dissolve cleaner. Turn heat
control OFF. Cover pans.
4. Allow solution to soak at least one hour, or overnight for heavy
scale buildup.
5. Drain hot water from pans. Scrub with a plastic scouring pad.
Rinse thoroughly with hot water, then dry.
6. Rell pans with hot tap water and resume operation.
7. Heavy scale buildup may require additional treatments.
CAUTION:
CHEMICAL BURN
HAZARD
Deilimng chemicals may be
caustic. Wear appropriate
personal protective equipment.
Follow cleaner manufacturer’s
instructions for safest use.

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
TROUBLESHOOTING SUGGESTIONS
12
There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
No power to warmer Circuit breaker off or tripped Reset circuit breaker
Warmer will not heat Temperature control not set Set control to desired temperature
Warmer trips circuit breaker
Wet insulation Verify ange-to counter seal is sound, or
reseal with food-grade silicone sealant
Pan leaking or other internal damage Contact your Authorized Wells Service Agency
for repairs
Internal damage Contact your Authorized Wells Service Agency
for repairs
Warmer slow to heat
Mineral deposits on pan acting as a
insulator Clean pan(s) with delime cleaner
Wired to wrong voltage Verify supply voltage - must match voltage on
warmer nameplate
Drain-equipped unit will not hold
water
Drain valve not fully closed Check drain valve for debris and close fully
Drain valve damaged or pan(s) leaking Contact your Authorized Wells Service Agency
for repairs
Auto-ll unit overows
Water level sensor dirty Clean water level sensor
Internal damage Contact your Authorized Wells Service Agency
for repairs
Auto-ll unit does not ll
Water supply turned off or restricted Be sure water supply is turned on and water
supply hose is not pinched or twisted
Bad Probe or other Internal Damage Contact your Authorized Wells Service Agency
for repairs
One or more pans of an auto-ll
unit do not ll Blocked drain manifold Clean drain manifold

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
MAINTENANCE INSTRUCTIONS
CARE OF STAINLESS STEEL
Stainless steel is a marvelous material: strong, lustrous and low maintenance. With
a minimum of care, it will normally retain its beauty and durability for the life of the
equipment. In some applications, however, special care is required in order to maintain
stainless steel’s special properties.
External components, such as cabinets and control panels, are nished with a grain
pattern. This pleasing nish is best maintained by cleaning with a non-abrasive
cleanser applied with a soft cloth. Rub only in the direction of the grain. In the absence
of visible grain, rub only along the longest axis of the appliance.
Restore stainless steel’s luster by applying a polish specically made for stainless steel.
Spray on, wipe off with a soft cloth, rubbing in the direction of the grain.
Never use metal implements, wire brushes, abrasive scratch pads or steel wool to
clean stainless steel.
Warmer pans, insets and other vessels are subject to a harsher environment. Wells
Manufacturing uses an very high quality stainless steel (#304DDQ) for our food warmer
pans. Even the highest quality stainless steel, however, is mostly iron, and will rust, pit
and corrode under the following conditions:
•Poor Water Quality: Hard water (water with a high content of dissolved minerals)
will leave mineral deposits when allowed to dry. Calcium (lime) can buildup on
heated surfaces, even under water. If left unattended, hard water spots and lime
buildup can lead to rusting, corrosion and pitting.
•Contact with Chlorides: Chlorides (specic compounds of chlorine) are found in
food, table salt and many cleansers. Chlorides can attack the surface of stainless
steel, resulting in corrosion and pitting.
Keep your stainless steel warmers clean and free from calcium buildup.
Use alkaline, alkaline chlorinated or non-chloride cleanser.
Use citric acid-based cleaners to remove calcium deposits.
For additional information, please read the NAFEM Stainless Steel Equipment and
Cleaning Guide. Contact NAFEM at :
North American Association of Food Equipment Manufacturers
401 N. Michigan Avenue
Chicago, Illinois 60611-4267
(312) 644-6610
13

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
MODEL NUMBER IDENTIFIER
14
Standard
Drain
Manifold
Auto-Fill
Narrow
Pan Assy w/
Auto-Fill Connection
Auto-Fill
Sensor Assy
Built-In Modular Warmer Identifier
IL2527
M300CTDNMAF6
96” Capillary Tube
Auto-Fill
Manifold
Narrow
Drain
T=Thermostat, E=Digital
Niether = Infinite
00= 20” Pan, 27=27” Pan
Corded
Number of Pans
M or MOD, same

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
EXPLODED VIEW & PARTS LIST
15
3
6
7
8
9
10
5
1
37
32
4
16
15
21
24 25
17
25
24 23
22
11
12
13
14
18
20
10
19
= AutoFill Units Only
26
See Detail A
Digital Controlled Units
29
27 28
30
34
36
35
“T” units only
33
31
32
BUILT-IN MODULAR WARMERS SK2615, Rev. A, 8/01/13

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
PARTS LIST: M200-227 SERIES
Model: Modular Warmers M200-227T, TD, TDM, TDMAF, TN, M200-227E, CE, ED, EDM, EDMAF, EN
Fig No Part No Description Qty Application
1P2-31869 SCREEN DRAIN ASSY WARMER 2 DRAIN UNITS
2
P2-Z14636 PAN ASSY 12X20 EAF W/TEE
1
M200 DIGITAL
P2-Z14647 PAN ASSY 12X27 EAF M227 DIGITAL
P2-WL0064 PAN ASSY W/ELBOW MODTDMN M200 T-STAT NARROW
WS-503893 PAN ASSY 200-500TDM A/F M200 T-STAT & INFINITE
WS-504101 PAN ASSY 12X27 AF M227 T-STAT
3
P2-Z14639 PAN ASSY 12X20 E
2
M200 DIGITAL
P2-Z14637 PAN ASSY 12X20 ED w/DRAIN M200 DIGITAL DRAIN
P2-Z14638 PAN ASSY 12X20 EDM M200 DIGITAL DRAIN, MANIFOLD
P2-Z14646 PAN ASSY 12X27 EDM M227 DIGITAL, DRAIN, MANIFOLD
1M227 DIGITAL, AUTOFILL
P2-WL0063 PAN ASSY AF MODTDMN
1
M200 T-STAT, AUTOFILL
WS-55742 PAN W/DRAIN 200-500DM/TDM M200 T-STAT & INFINITE, DRAIN,
MANIFOLD
WS-55741 PAN W/O DRAIN 200-500 / T
2
M200 T-STAT & INFINITE
WS-53201 PAN W/DRAIN 200-500 /TD M200 T-STAT & INFINITE, DRAIN
WS-500700 PAN ASSY 12X27 TDM M227 T-STAT, DRAIN, MANIFOLD
42V-35609 VALVE 1 IN GATE BRONZE 1 MANIFOLD UNITS
5WS-503713 PROBE ASSY, SS AUTOFILL WRMR 1 AUTOFILL UNITS
62K-48198 ELBOW 3/8 X 90DEG BRASS 1 AUTOFILL UNITS
72K-48197 NIPPLE 3/8 NPT X 2 BRASS 1 AUTOFILL UNITS
82V-47650 VALVE ANTISYPHON 3/8 1 AUTOFILL UNITS
92K-47662 FTG STR BRS 3/8NPT X3/8IN 1 AUTOFILL UNITS
10 2C-46591 CLAMP HOSE 5/8 2 AUTOFILL UNITS
11 2K-31040 BUSHING HEYCO 7/8 OD 1 THERMOSTAT UNITS
12 WS-50131 TERM BLOCK KIT (RETRO 30131) 1 INFINITE & AUTOFILL UNITS
13 2C-41974 NUT 8-32 HEX 7/8 LONG ALU 2 AUTOFILL UNITS
14 2J-30385 LIGHT SIGNAL GLO DOT RED 2INFINITE UNITS
2J-35687 LIGHT SIGNAL GLO DOT T-STAT UNITS
15
P2-Z12288 PANEL, CONTROL 1T-STAT & INFINITE UNITS NON-AF
P2-Z19780 CONTROL PANEL MOD227TDM-K
P2-Z12589 PANEL, CONTROL MOD 200/400 1 AUTOFILL UNITS
16
E7-49046 BOX OUTLET MOD WARM
1
T-STAT & INFINITE UNITS NON-AF
P2-Z19779 HOUSING CONTROL MOD227TDM-K
P2-48175 BOX OUTLET MOD200/400TDM AUTOFILL UNITS
17
2T-38968 THERMO K TYPE
2
T-STAT UNITS
2T-46551 THERMO CTRL 96IN CAP T-STAT UNITS w/ 96IN CAPILLARY
2T-45917 THERMO CTRL W/AUX WARMERS T-STAT UNITS, AUTOFILL
2E-30570 SWITCH INFINITE, 120V 2INFINITE UNITS, 120V
2E-30562 SWITCH INFINITE, 240V INFINITE UNITS, 240V
18 2R-44373 KNOB CONTROL ASSY WARMERS 2INFINITE UNITS
2R-40498 KNOB ASSY MOD 100DT T-STAT UNITS
20 2E-46529 SOLENOID VALVE 1/4NPT 240 1 AUTOFILL UNITS
21 P2-40843 BRKT MTG THERMO INFINITE 2T-STAT & INFINITE UNITS
P2-48176 BRKT THERMO MOD200TDM AUT T-STAT AUTOFILL
22 2E-306865 CONTROL LIQ LEVEL 208/240 1 AUTOFILL UNITS
23 2I-40034 GROMMET SCREW T4 4 AUTOFILL UNITS
16

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
PARTS LIST: M200-227 SERIES
Model: Modular Warmers M200-227T, TD, TDM, TDMAF, TN, M200-227E, CE, ED, EDM, EDMAF, EN
Fig No Part No Description Qty Application
24 2K-33996X FTG FLEX CONDUIT 90X3/8 2
25 2I-Z12311 GASKET-FIBER WASHER 2
26 P2-300712 COVER BOT M227-427TDM/AM 2 M227
P2-35004 COVER BOTTOM 200 SERIES 1 M200
27 P2-303359 SHROUD SIDE MODS ROHS 2M200
P2-300593 SHROUD SIDE MOD TDN M200 NARROW
28
P2-Z15948 SHROUD, FRONT UNIVERSAL
1M200, 227
P2-33909 SHROUD FRONT/REAR MOD200
P2-Z19777 SHROUD, FRONT 227TDM-KFC MOD227TDM-K
P2-300592 SHROUD FRT/RR MOD200TDN 2 M200 NARROW
29 2H-36050 INSUL FG .6 MICRO 1/36
SOLD
BY
FOOT
30 2H-36196 INSUL FG .6 MICRO 1X45
SOLD
BY
FOOT
31
P2-WL0082 PAN ELEM ASSY
2
M200 DIGITAL
P2-WL0096 PAN ELEM ASSY MOD 227-527 M227 DIGITAL
WS-503843 KIT PAN ELEM W/ELEMENT 208/240 M200 T-STAT
WS-503701 KIT ELEM PAN W/ELEMENT M200 T-STAT NARROW
WS-503840 KIT ELEM PAN W/ELEMENT M227 T-STAT
32
WS-50396 ELEM 120V 1200W
2
M200 INFINITE, 120V
WS-50398 ELEM 240V 1200W M P M200 INFINITE, 240V
2N-46681UL ELEM 120V 1650W M200 T-STAT, 120V
2N-303375UL ELEM HEATING 240V 1650W M200 T-STAT, 240V
2N-300706UL ELEM 240V 1650W 12 X 27 M227
33
WS-55707 COVER ELEM MOD WARMER
2
INFINITE UNITS
WS-503842 KIT ELEM PAN W/O ELEMENT M200, T-STAT & DIGITAL
WS-503370 PAN, ELEMENT MODS M200 NARROW
WS-503841 KIT ELEM PAN W/O ELEMENT M227
34 D8-303352 BRKT THERMO BULB 2 THERMOSTAT UNITS
35 P2-WL0081 PAN ELEM ASSY MOD200-500 2 INFINITE 208/240V
36 WS-50374 THERMO, HI-LIMIT, SFTY, 550F 2 INFINITE UNITS
37 WS-53762 TOP W/WELLSLOK MOD200 1M200
P2-300714 TOP ASSY MOD227 MOD227
NI 2C-30397 CLIP ELEM WRMRS SML 18 VARIOUS OLDER UNITS
NI 2E-200372 CORD SET, 12/3 CORD 6-20 1 M200C
17

M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
PARTS LIST: M300-327 SERIES
18
Model: Modular Warmers M300-327T, TD, TDM, TDMAF, TN, M300-327E, CE, ED, EDM, EDMAF, EN
Fig No Part No Description Qty Application
1P2-31869 SCREEN DRAIN ASSY WARMER 3 DRAIN UNITS
2
P2-Z14636 PAN ASSY 12X20 EAF W/TEE
1
M300 DIGITAL
P2-Z14647 PAN ASSY 12X27 EAF M327 DIGITAL
P2-WL0066 PAN ASSY MODTDMNAF W/ELBOW M300 T-STAT NARROW
WS-503893 PAN ASSY 200-500TDM A/F M300 T-STAT & INFINITE
WS-504101 PAN ASSY 12X27 AF M327 T-STAT
3
P2-Z14639 PAN ASSY 12X20 E
3
M300 DIGITAL
P2-Z14637 PAN ASSY 12X20 ED w/DRAIN M300 DIGITAL DRAIN
P2-Z14638 PAN ASSY 12X20 EDM M300 DIGITAL DRAIN, MANIFOLD
P2-Z14646 PAN ASSY 12X27 EDM M327 DIGITAL, DRAIN, MANIFOLD
2M327 DIGITAL, AUTOFILL
P2-WL0064 PAN ASSY W/ELBOW MODTDMN 2 M300 T-STAT, NARROW, AUTOFILL
M300 T-STAT & NARROW
P2-WL0065 PAN ASSY MID MOD300TDMN 1 M300 T-STAT, NARROW, 2-ELBOWS
WS-55741 PAN W/O DRAIN 200-500 / T
3
M300 T-STAT & INFINITE
WS-53201 PAN W/DRAIN 200-500 /TD M300 T-STAT & INFINITE, DRAIN
WS-55742 PAN W/DRAIN 200-500DM/TDM M300 T-STAT & INFINITE, DRAIN, MANIFOLD
2M300 T-STAT DRAIN, AUTOFILL
P2-WL0263 PAN ASSY MOD W/T DRN
PASSIVATED
3
MOD300TDMTHP
D8-301955 PAN ASSY SMPT-27 / MOD M327 T-STAT
P2-WL0061 PAN ASSY w/DRAIN M127TD M327 T-STAT, DRAIN
WS-500700 PAN ASSY 12X27 TDM M327 T-STAT, DRAIN, MANIFOLD
42V-35609 VALVE 1 IN GATE BRONZE 1 MANIFOLD UNITS
5WS-503713 PROBE ASSY, SS AUTOFILL WRMR 1 AUTOFILL UNITS
62K-48198 ELBOW 3/8 X 90DEG BRASS 1 AUTOFILL UNITS
72K-48197 NIPPLE 3/8 NPT X 2 BRASS 1 AUTOFILL UNITS
82V-47650 VALVE ANTISYPHON 3/8 1 AUTOFILL UNITS
92K-47662 FTG STR BRS 3/8NPT X3/8IN 1 AUTOFILL UNITS
10 2C-46591 CLAMP HOSE 5/8 2 AUTOFILL UNITS
11 2K-31040 BUSHING 7/8 OD 1 THERMOSTAT UNITS
12 WS-50131 TERM BLOCK KIT (RETRO 30131) 1 INFINITE & AUTOFILL UNITS
13 2C-41974 NUT 8-32 HEX 7/8 LONG ALU 2 AUTOFILL UNITS
14 2J-30385 LIGHT SIGNAL GLO DOT RED 3INFINITE UNITS
2J-35687 LIGHT SIGNAL GLO DOT T-STAT UNITS
15 P2-Z12592 PANEL, CONTROL 1INFINITE UNITS NON-AF
P2-Z12586 PANEL, CONTROL MOD300TDM T-STAT UNITS
15 P2-Z12588 PANEL, CONTROL MOD600 TDM 1 M300/327 T-STAT, DRAIN, MANIFOLD
16 P2-46685 BOX OUTLET MOD300, 400, 500 1T-STAT & INFINITE UNITS NON-AF
16 P2-48178 BOX OUTLET MOD600TDM AUTOFILL UNITS
17
2T-38968 THERMO K TYPE
3
T-STAT UNITS
2T-46551 THERMO CTRL 96IN CAP T-STAT UNITS w/ 96IN CAPILLARY
2T-45917 THERMO CTRL W/AUX WARMERS T-STAT UNITS, AUTOFILL
2E-30570 SWITCH INFINITE, 120V 3INFINITE UNITS, 120V
2E-30562 SWITCH INFINITE, 240V INFINITE UNITS, 240V
18 2R-44373 KNOB CONTROL ASSY WARMERS 3INFINITE UNITS
2R-40498 KNOB ASSY MOD 100DT T-STAT UNITS
19 P2-46587 HOSE MOD AUTOFILL 36” 1 AUTOFILL UNITS
This manual suits for next models
114
Table of contents
Other Wells Food Warmer manuals

Wells
Wells MOD-500TDMAF User manual

Wells
Wells BMW-206ULRT User manual

Wells
Wells HW-106D User manual

Wells
Wells TMPT User manual

Wells
Wells MOD-100T User manual

Wells
Wells HDW-2 User manual

Wells
Wells HMP6D User manual

Wells
Wells TCW-Series User manual

Wells
Wells HW/SMP-6D User manual

Wells
Wells SS4D User manual

Wells
Wells SMPT-EU User manual

Wells
Wells MOD-300TDMAF User manual

Wells
Wells HW-10 User manual

Wells
Wells Showroom WNA-1 User manual

Wells
Wells SS-206E User manual

Wells
Wells MOD-100TDAF User manual

Wells
Wells SS-206 User manual

Wells
Wells SMPT User manual

Wells
Wells SS-10T User manual

Wells
Wells DeLUXE User manual