manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Niigata seiki
  6. •
  7. Touch Panel
  8. •
  9. Niigata seiki DEI-WKS-N User manual

Niigata seiki DEI-WKS-N User manual

Other Niigata seiki Touch Panel manuals

Niigata seiki ADM-A User manual

Niigata seiki

Niigata seiki ADM-A User manual

Niigata seiki DEI-233S1 User manual

Niigata seiki

Niigata seiki DEI-233S1 User manual

Popular Touch Panel manuals by other brands

FlowLine Data loop quick start

FlowLine

FlowLine Data loop quick start

ALPEX AEx-8 P Series user manual

ALPEX

ALPEX AEx-8 P Series user manual

Ltech E5S manual

Ltech

Ltech E5S manual

Harman AMX MODERO S MSD-701-L2 quick start guide

Harman

Harman AMX MODERO S MSD-701-L2 quick start guide

Acnodes PC 1150 installation guide

Acnodes

Acnodes PC 1150 installation guide

AIS IP10IA99 series user guide

AIS

AIS IP10IA99 series user guide

IBASE Technology ASTUT-152-RE1S user manual

IBASE Technology

IBASE Technology ASTUT-152-RE1S user manual

YASKAWA TP 610C manual

YASKAWA

YASKAWA TP 610C manual

B&R Power Panel C Series user manual

B&R

B&R Power Panel C Series user manual

AXIOMTEK GOT321W-521 user manual

AXIOMTEK

AXIOMTEK GOT321W-521 user manual

TRIDONIC.ATCO x-touchBOX Operation manual

TRIDONIC.ATCO

TRIDONIC.ATCO x-touchBOX Operation manual

Qomo QIT1386 user manual

Qomo

Qomo QIT1386 user manual

DFI KS104-CD user manual

DFI

DFI KS104-CD user manual

AMX AXP-PPC Dimensional drawing

AMX

AMX AXP-PPC Dimensional drawing

Sartorius X3 PR 5410 operating manual

Sartorius

Sartorius X3 PR 5410 operating manual

AMX Modero X Series quick start guide

AMX

AMX Modero X Series quick start guide

Advantech TPC-30 Series user manual

Advantech

Advantech TPC-30 Series user manual

B&R Industries MAPPC900-ENG user manual

B&R Industries

B&R Industries MAPPC900-ENG user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DEI-WKS-N
SWISS MADE
MODE SET
Thank you for purchasing the Digital S-Line Indicator.
For proper operation, please read this manual thoroughly before use.
DIGITAL S-LINE INDICATOR INSTRUCTION MANUAL
Model No. DEI-WKS-N
LCD Display
[SET]Button
Center (“Favorite”)
Button
Stem (Mounting Shaft)
Spindle
Contact Point
Display Rotates 270°
Easy to read from any position.
Accessories
CR2032
CR2032 (Lithium Cell)
※Included for test
Battery Cover
[MODE]Button
PARTS IDENTIFICATION
【Power ON】
Press [MODE], [SET], or Center Button to turn on power.
【Power OFF, Sleep Mode】
Press and Hold the [SET]button to enter Sleep Mode; continue
pressing to turn power OFF.
※Sleep Mode is entered automatically if gauge is idles for about
20 min.
※To exit Sleep Mode, press any button or move the Spindle.
※When remaining battery level is low, the『』icon is displayed;
please replace battery.
※To reset all settings, press and hold [SET]and [MODE]at
same time for about 4 sec., “”will display.
B
[SET]Button Sleep Mode
Power OFF
(Press and Hold)
(Press and Hold)
[SET]Button
mm
1
mm
POWER
BATTERY REPLACEMENT
①Remove the (2x)battery screws using (+)PH#0 screwdriver.
Gently pry open the cover using a small standard screwdriver
in the notch and slide out the battery.
②Insert the new battery following the polarity markings on the
cover.
③Replace Battery Cover and tighten screws to secure.
CR2032
+
Notch
Battery
Battery Cover
Battery Cover
NOTICE Use only CR2032 type battery.
Tolerance Setting capability
Calculation capability 
Display rotates 270°
Programmable “Favorite”Button
(Can be set for one touch access to frequently used functions.)
MIN、MAX、MINMAX (TIR)display functions
Direction of measurement (+/ −)switchable
Preset function
Sleep mode (after approx. 20 min.)
Made in Switzerland
●
●
●
●
●
●
●
●
●
①Mount indicator securely, such as on optional Magnetic Base,
and make sure that the Spindle is perpendicular to the
measurement surface.
②Press [MODE], [SET], or Center Button to turn on power.
③Check that the probe is in contact with surface, and refer to the
following to set the 0-Point.
    FUNCTION SETUP: “Preset Value”
    Programmable “Favorite”Button: “Zero setting”
LCD will display “0.000mm”or “0.0000mm”.
④With Gauge body held fixed, and the probe in contact with the
workpiece, the LCD will display the difference between
workpiece and reference plane.
Refer to
Refer to
See Reverse for Feature Settings →
FEATURES
SPECIFICATIONS
φ8mm
140g
5〜40℃
DEI-WKS-N
0.001mm/0.0001mm
(switchable)
0.5μm
0-12.5mm
Less than 1.5N
2.3μm
0.0001mm
CR2032 (Lithium cell)×1
Model No.
Measurement Range
Resolution
Displayed Resolution
Accuracy
Measurement Force
Repeatability
Mounting Shaft Diameter
Operating Temp. Range
Power Supply
Weight
Measured value is wrong
Clean measuring surfaces with
lens tissue or similar.
Confirm and re-set 0-Point setting.
●
●
LCD does not display
Displayed value is
unstable
Display is hard to read
●
●
●
Cycle power by removing and
replacing battery.
Replace battery with new one.
●
●
※If problem persists, or if you have any questions, please contact distributor
or place of purchase.
※Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
Error Condition Corrective Action
TROUBLESHOOTING
HOW TO USE
mm
FUNCTION SETUP
mm
1
mm
mm
TOL
1
mm
1
mm
TOLINPUT
1
mm
TOLINPUT
1
TOL
mm
1
PRESET INPUT 
mm
1
mm
1
mm
※This option
not used
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
【Measurement Display】
Press the [MODE]Button, or Press-and-hold, to access and cycle through the functions
as show in the chart below. When the function is displayed, press Center Button to access.
※If no operation is performed after 5 seconds, display will return to measurement screen.
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
Long Press
[MODE]Button
Return to
Measurement Display
【REF1 / REF2 Mode】
Two different Zero points, REF1 and REF2 can
be used (also Tolerance settings.)This feature is
helpful when there are multiple measurement
criteria in use at the same time.
【Preset Value】
Any number can be preset for use in setting display
during measurement by using this function.
●Press [SET]in measurement screen to set display
the preset value.
Press Center Button for numeric display. Press
Center Button to move the cursor, and [SET]to
change the value of that character. Press [Mode]to
enter.
To Set
Press Center Button to display REF1 / REF2, then
press [SET]to select.
To Set
●Center Button can be programmed to call up a frequently used
function with a single press while taking measurements.
※Programmed setting is reset when power is turned off.
Programmable “Favorite”Button
Press and hold the Center “Favorite”Button to enter the button
programming selection mode.Press Center Button to cycle through the
options and then press [MODE]or [SET]to select.
To Set
Long Press
Center Button
※This option
not used
※This option
not used
Hold function
Reset MIN,
MAX, DELTA
display
Zero setting
Switch
REF1 / REF2
Center Button Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Center Button
Preset
NOR, MIN,
MAX, DELTA
mode
Tolerance
Setting function
ON / OFF
Resolution setting
0.001 / 0.0001
Measurement
Direction +/ −
Calculation
function
※Set to 1.000
to disable
●
●
●
●
●
●
●
●
●
This is a precision instrument, handle with care. Do not drop or subject
to excessive forces.
Keep away form high voltage and strong magnetic fields; instrument
damage may result.
Do not use or store in direct sunlight or locations with high
temperatures such as in a car, or near a stove or heat source.
When taking measurements, hold gauge securely, such as in
magnetic base. (sold separately)
Please do not disassemble or modify.
Remove dust and cutting chips after use and apply rust preventative
oil to metallic surfaces. Please keep out of reach of children.
Do not use organic solvents to clean the body of the instrument.
When not being used for a long period of time, please remove battery.
Only use as directed. Improper use may cause accident or injury.
CAUTION
I303-K
1606
Niigata seiki Co., Ltd.
6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-31-5670 Fax. : +81-256-39-7730
MAIL [email protected]
URL http://www.niigataseiki.co.jp
【Display Mode】
Press Center Button
to move the cursor,
and [SET]to change
the value of that
character. Press
[Mode]to enter.
【Tolerance Function】
With tolerance values set, gauge will show if
measurement is within range.
Colored lights will show tolerance determination
for
easy
judgment.
To reverse the display indication, reverse the entry of the Lower and
Upper limits.
【Measurement Direction】
mm
mm
【Calculation Function】
You can enter a number to multiply by the
amount of Spindle movement.
mm
【Auto Off】
mm
【Button Lock】
For locking buttons while taking measurements.
mm
●When lock is ON,『  』icon will display on LCD.
●To release the lock mode, press and hold [SET]
until “”is displayed.
Ex: If computation factor is set to “2.00", and measured value is “4.25”
(actual amount of Spindle motion,)the displayed reading will be “8.50”
Set Lower
Limit
Set Upper
Limit
For measurement Lower limit set to “+3”, Upper limit set to “+6”
Measurement: 2.25mm
Red Light
Measurement: 4.00mm Measurement: 7.25mm
Measurement: 7.25mm
Orange Light
Ex:
Green Light
OK
For measurement Lower limit set to “+6”, Upper limit set to “+3”
Red Light
Measurement: 4.00mmMeasurement: 2.25mm
Orange Light
Ex:
Green Light
OK
Set measurement mode: (MIN),(MAX),
(MINMAX),or
(NORMAL)
※“deltA”(MINMAX)
→Display maximum displacement without regard to direction (TIR).
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
[MODE]Button
Center Button Center Button
Press Center Button to display options, then press
[SET]to select.
To Set
【Resolution】
Press Center Button to display 0.001 / 0.0001,
then press [SET]to select.
To Set
Press Center Button to display ON / OFF, then
press [SET]to select.
To Set
Press Center Button to move the cursor, and [SET]
to change the value of that character. Press [Mode]
to enter.
To Set
Press Center Button to display “ ” / “”,
and press [SET]to select.
『』…disabled『』… Auto off if idle for 20 min.
To Set
Press Center Button to display (+)/ (−), then
press [SET]to select.
To Set
※Tolerance values can be set for MIN,
MAX, and DELTA modes.