Nikon T-RCP User manual

M314E 04.7.CF.3(5/5)
T-RCP Remote Control Pad
Instructions


- 1 -
Contents
Introduction .................................................................................................................................................................4
1 General Description ..............................................................................................................................4
2 Appearance of Remote Control Pad .....................................................................................................5
3 Connection of Remote Control Pad and HUB Controller......................................................................6
4 Startup and Shutdown...........................................................................................................................7
5 Screen Configuration ............................................................................................................................8
(1) Summary.....................................................................................................................................8
(2) Layout of OPERATION Screen ..................................................................................................8
(3) Configuration of SETTING MENU Screens................................................................................9
(4) Configuration of MAINTENANCE MENU Screens ...................................................................12
I
Preparations........................................................................................................................................................13
1 Connecting and Setting Electrical Components .................................................................................13
(1) Connecting Electrical Components to HUB Controller .............................................................13
(2) Turning ON the EXTERNAL Switch of Dia-Illumination Lamp Power Supply ..........................14
(3) Placing Uniblitz Shutter Controller into N.C. Mode...................................................................14
2 Setting Attachment Information...........................................................................................................15
(1) Objective ...................................................................................................................................15
(2) Condenser Module....................................................................................................................16
(3) Filter Block ................................................................................................................................17
(4) Excitation Filter .........................................................................................................................18
(5) Barrier Filter ..............................................................................................................................19
3 Setting Uniblitz Shutter Controller Connection ...................................................................................20
4 Setting Shutter Key Function ..............................................................................................................21
5 Setting Foot Switch Function ..............................................................................................................22
6 Indicating Z-Axis Position....................................................................................................................23
II
Basic Operation ..................................................................................................................................................24
1 Selecting Objective .............................................................................................................................24
2 Selecting Filter Block...........................................................................................................................25
3 Selecting Optical Path.........................................................................................................................26
4 Selecting Condenser Module ..............................................................................................................26
5 Selecting Excitation Filter....................................................................................................................27
6 Selecting Barrier Filter.........................................................................................................................27
7 Inserting/Removing Analyzer ..............................................................................................................28
8 Opening/Closing Shutter .....................................................................................................................28
9 Operating Dia-Illumination Lamp (12V100W lamp only).....................................................................28
(1) Turning Remote Control Operation ON/OFF............................................................................28
(2) Turning Lamp ON/OFF .............................................................................................................29
(3) Adjusting Lamp Voltage ............................................................................................................29
10 Resetting Z-Axis Position to Zero .......................................................................................................30
11 Outputting External Trigger .................................................................................................................30

- 2 -
III
Additional Functions............................................................................................................................................31
1 Interlocking Objective and Condenser Module Selection ...................................................................31
2 Interlock Filter Block and Excitation/Barrier Filters Selection .............................................................32
3 Restricting Rotation of Revolving Nosepiece......................................................................................33
(1) Set Rotation Restriction ............................................................................................................33
(2) Cancel Rotation Restriction ......................................................................................................34
4 Performing Parfocal Corrections .........................................................................................................35
(1) Setting Focus Position ..............................................................................................................35
(2) Setting Parfocal Correction Mode.............................................................................................36
(3) Correcting Preset Focus Position .............................................................................................37
(4) Checking Preset Focus Position...............................................................................................38
IV
Other Operations ................................................................................................................................................39
1 Operating LCD Backlight.....................................................................................................................39
(1) Turning Backlight ON/OFF .......................................................................................................39
(2) Adjusting Brightness of Backlight .............................................................................................39
2 Adjusting LCD Contrast.......................................................................................................................40
V
Operation and Indication Functions ....................................................................................................................41
1 Setting Functions for the Fine Focus Knob.........................................................................................41
(1) Changing Operation Mode of Fine Focus Knob .......................................................................41
(2) Adjusting Travel Distance for Fine Mode..................................................................................42
2 Setting Indication on Operation Screen ..............................................................................................44
3 Setting Buzzer ON/OFF ......................................................................................................................45
4 Setting Remote Control ON/OFF ........................................................................................................46
5 Turning ON/OFF LED with LCD ON/OFF Key....................................................................................47
6 Setting Communications Delimiter of External Device .......................................................................48
7 Registering Data for Optical Members................................................................................................49
(1) Objective ...................................................................................................................................49
(2) Condenser Module....................................................................................................................51
(3) Filter Block ................................................................................................................................52
(4) Dichroic Mirror...........................................................................................................................54
(5) Excitation Filter .........................................................................................................................55
(6) Barrier Filter ..............................................................................................................................56

- 3 -
VI
Maintenance Menu .............................................................................................................................................57
1 Indicating Program Version and Checksum........................................................................................57
2 Testing Electrical Component Operations ..........................................................................................58
(1) All-Test Mode............................................................................................................................58
(2) Individual Test Mode.................................................................................................................60
3 Testing Hardware of Remote Control Pad ..........................................................................................61
(1) Key Input Test...........................................................................................................................61
(2) LED ON/OFF Test ....................................................................................................................62
(3) LCD Indication Test ..................................................................................................................62
4 Initializing Focus Motion Potentiometer ..............................................................................................63
5 Resetting Remote Control Pad Settings to Default Values ................................................................64
6 Resetting HUB Controller Settings to Default Values .........................................................................65
7 Reset Control Data to Default Values.................................................................................................66
(1) All Components.........................................................................................................................66
(2) Revolving Nosepiece ................................................................................................................67
(3) Condenser Module....................................................................................................................68
(4) Optical Path ..............................................................................................................................69
(5) Filter Block ................................................................................................................................70
(6) Excitation Filter .........................................................................................................................71
(7) Barrier Filter ..............................................................................................................................72
(8) Auxiliary Filter ...........................................................................................................................73
VII
Troubleshooting ..................................................................................................................................................74
1 Remote control pad doesn’t start up. (TITLE screen appears, and the screen freezes.)...................74
2 Electrical component doesn’t operate.................................................................................................74
3 Revolving nosepiece doesn’t rotate at a certain position of the fine focus knob. ...............................74
4 Dia-illumination lamp cannot be turned ON or OFF............................................................................74
5 Voltage of dia-illumination lamp cannot be adjusted. .........................................................................75
6 Opening/closing status of Uniblitz shutter doesn’t coincide with LED indication................................75
7 Objective information is not indicated. ................................................................................................75
8 Condenser module information is not indicated..................................................................................75
9 Filter block information is not indicated...............................................................................................75
10 Excitation filter information is not indicated.........................................................................................76
11 Barrier filter information is not indicated..............................................................................................76
12 Dia-illumination lamp voltage is not indicated.....................................................................................76
13 Z-axis coordinates are not indicated. ..................................................................................................76
14 Buzzer doesn’t sound when a key is pressed.....................................................................................76

Introduction
1 General Description
- 4 -
Introduction
1 General Description
The remote control pad is connected to the HUB controller and used for remote control of the accessory electrical
components of the ECLIPSE TE2000 series.
The remote control pad enables control of the electrical components with key operations on the pad. The remote
control pad also indicates a variety of information using the LED and displays on the LCD, such as electrical
component positions and information on the attached optical members.

Introduction
2 Appearance of Remote Control Pad
- 5 -
2 Appearance of Remote Control Pad
No. Parts Function when
OPERATION screen is indicated
Functions when setting
menu/maintenance menu is indicated
1 Liquid crystal display (LCD)
OPERATION screen: Indicates
electrical component positions and
information on the attached optical
members
Setting menu: Allows setting of
various functions/parameters of the
electrical components.
2 OBJECTIVE key Selects an objective lens
3 SHUTTER A key Opens/closes the shutter allocated to
Shutter A key
4 SHUTTER B key Opens/closes the shutter allocated to
Shutter B key
5 EXCITER key Selects an excitation filter
6 BARRIER key Selects a barrier filter
Enters alphanumeric characters.
7 EPI-FILTER key Selects a filter block
8 Z-AXI. RESET key Resets the z-axis position to zero
9 CAMERA EXP. key Outputs an external trigger
10 LCD MODE key Changes to another screen Changes to another screen.
11 LCD ON/OFF key Turns ON/OFF the LCD backlight
12 LCD Bright/Dark key Adjusts the brightness of the LCD
backlight
13 DIA LAMP REMOTE key Turns ON/OFF the remote control
operation of the dia-illumination lamp
14 DIA LAMP ON/OFF key Turns ON/OFF the dia-illumination
lamp
15 DIA LAMP ADJ. key Adjusts the voltage of the
dia-illumination lamp PREV/NEXT keys (Change selection.)
16 CONDENSER key Selects a condenser module BS key (Deletes entered letters), CLR
key (All clear)
17 ANALYZER IN/OUT key Inserts/removes the analyzer
18 LIGHT PATH key Selects an optical path Cursor key (Selects an item.)
Return key (Confirms selection.)

Introduction
3 Connection of Remote Control Pad and HUB Controller
- 6 -
3 Connection of Remote Control Pad and HUB Controller
Connect the HUB connection cable fixed to the remote control pad to REMOTE connector of the HUB controller as
shown below.
Hub connection cable
[Rear panel of remote control pad]
REMOTE connector
[Connector panel of HUB controller]

Introduction
4 Startup and Shutdown
- 7 -
4 Startup and Shutdown
1 Startup
1) Turn ON power for the dia-illumination lamp. When
using Uniblitz shutter, also turn ON power for the
Uniblitz shutter controller.
2) Turn ON the power to the HUB controller.
3) Power is supplied to the remote control pad from the
HUB controller.
AC
[Side panel of HUB controller]
The TITLE screen appears on the LCD of the remote control pad and changes to the OPERATION screen in 2 or
3 seconds.
T-RCP REMOTE CONTROL PAD
V1.00
[TITLE screen] [OPERATION screen]
Note:
When you use the remote control pad for the first time, all the optical members, such as the objectives, will
be set by default to “Not attached” and the Operation screen will appear as shown below.
“---------” indicates that the optical
member is “not attached.”
If an electric component is not connected to the HUB controller, the indication of the component will be
blank.
If the electrical component is not connected to the HUB controller correctly, the HUB controller cannot
detect the component and the indication of the component will also be blank.
If no electrical component is connected to the HUB controller, the screen will appear as shown below.
2 Shutdown
1) Turn OFF the power to the HUB controller.
2) Turn OFF power for the dia-illumination lamp and
the Uniblitz shutter controller.
Power switch
Connect the specified AC adapter

Introduction
5 Screen Configuration
- 8 -
5 Screen Configuration
(1) Summary
Power ON
MODE key
MODE key
Is MODE key
pressed?
MODE key
No
Yes
T-RCP REMOTE CONTROL PAD
V1.00
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
MAINTENANCE MENU
1.Version
2.TEST1
3.TEST2
4.PAD Data
5.HUB Data
6.Control Data
a.All Control Data
b.Revoiving Nosepiece
c.Condenser Cassette
d.Light Path
e.Filter Block
f.Exciter Filter
g.Barrier Filter
h.AUX Filter
Note:
If power is turned ON while the MODE key is held down, the MAINTENANCE MENU screen will appear.
(2) Layout of OPERATION Screen
Objective lens
information
P. 15
Condenser module
information
P. 16
Excitation filter
information
P. 18
Barrier filter
information
P. 19
Filter block information
P. 17
Z-axis position
P. 23
Dia-Illumination
lamp voltage
P. 29
Note:
If the electric components are not connected to the HUB controller, information for the unconnected
components will not appear.

Introduction
5 Screen Configuration
- 9 -
(3) Configuration of SETTING MENU Screens
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
CONDENSER
Name
1[BF ]
2[PhL ]
3[Ph1 ]
4[Ph2 ]
5[Ph3 ]
Edit
FILTER
Name
1[UV-1A ] EX : EX365/10
2[V-1A ] DM : DM400
3[BV-1A ] BA : BA400
4[B-1A ]
5[G-1A ]
6[DIA ]
Edit
EXCITER
Name
1[EX465-495 ]5[――――――――――]
2[EX460-500 ]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
BARRIER
Name
1[BA515-555 ]5[――――――――――]
2[BA510 ]6[――――――――――]
3[BA510-560 ]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
COMBINATION(OBJ.>CONDENSER)
Objective Condenser
1.P Fluor DL 4x [2]:PhL
2.P Fluor DL 10x [3]:Ph1
3.P Fluor ELWD DM 20x [3]:Ph1
4.P Fluor ELWD DM 40x [4]:Ph2
5.P Fluor ELWD DLL 60x [4]:Ph2
6.P Fluor DLL 100x[5]:Ph3
COMBINATION(FILTER>EX/BA)
Filter EX BA
1.UV-1A [-]:―――――――[-]:―――――――
2.V-1A [-]:―――――――[-]:―――――――
3.BV-1A [-]:―――――――[-]:―――――――
4.B-1A [1]:465-495[1]:515-555
5.G-1A [-]:―――――――[-]:―――――――
6.DIA [8]:DIA [8]:DIA
MORE
Rotation Stopper
Focus
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
*1
*3
*4
*5
*6
*2
MODE key
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][DL 4x][-]
2[P Fluor ][DL 10x][-]
3[P Fluor ][ELWD DM 20x][*]
4[P Fluor ][ELWD DM 40x][*]
5[P Fluor ][ELWD DLL 60x][*]
6[P Fluor ][DLL 100x][*]
Edit Type N.A. W.D.
Dry 0.13 17.10
[]key

Introduction
5 Screen Configuration
- 10 -
CONDENSER
Name
1[BF ]
2[PhL ]
3[Ph1 ]
4[Ph2 ]
5[Ph3 ]
Edit
FILTER
Name
1[UV-1A ] EX : EX365/10
2[V-1A ] DM : DM400
3[BV-1A ] BA : BA400
4[B-1A ]
5[G-1A ]
6[DIA ]
Edit
EXCITER
Name
1[EX465-495 ]5[――――――――――]
2[EX460-500 ]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
BARRIER
Name
1[BA515-555 ]5[――――――――――]
2[BA510 ]6[――――――――――]
3[BA510-560 ]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[――――――――――]
Mag. :[0 ]x
N.A. :[0 ]
W.D. :[0 ]
Type :[――――――――――]
EDIT CONDENSER DATA
Location:[Other1]
Name :[ ]
EDIT FILTER DATA
Location:[Other1]
Name :[ ]
EX :[――――――――――] Edit
DM :[――――――――――] Edit
BA :[――――――――――] Edit
EDIT DM DATA
Location:[Other1]
Name :[ ]
EDIT EX DATA
Location:[Other1]
Name :[ ]
EDIT BA DATA
Location:[Other1]
Name :[ ]
EDIT BA DATA
Location:[Other1]
Name :[ ]
EDIT EX DATA
Location:[Other1]
Name :[ ]
*1
*2
*3
*4
*5
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][DL 4x][-]
2[P Fluor ][DL 10x][-]
3[P Fluor ][ELWD DM 20x][*]
4[P Fluor ][ELWD DM 40x][*]
5[P Fluor ][ELWD DLL 60x][*]
6[P Fluor ][DLL 100x][*]
Edit Type N.A. W. D.
Dry 0.13 17.10

Introduction
5 Screen Configuration
- 11 -
MORE
Rotation Stopper
Focus
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
ROTATION STOPPER
Current setting:OFF
ON OFF
FOCUS KNOB MODE
[Coarse]
FOCUS MODE
[OFF]
FOCUS POSITION
SET SHIFT CLEAR
OBJECTIVE
Series Mag.
[P Fluor ][DL 10x]
OTHER UNIT
UNIBlitze Shutter :[OFF]
REMOTE CONTROL PAD
Display
Objective :[ON ]
Condenser :[ON ]
Filter :[ON ]
Exciter :[ON ]
Barrier :[ON ]
DIA Lamp :[ON ]
Z-Position :[OFF]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
SHUTTER KEY
Shutter A Shutter B
[ ][ ]
FOOT SWITCH
Unused
Revolving nosepiece
Condenser cassette
Filter block
Exciter filter
Barrier filter
AUX filter
COMMUNICATION DELIMITER
FOR EXTERNAL UNIT
CR LF
MODE key
*6
[]key

Introduction
5 Screen Configuration
- 12 -
(4) Configuration of MAINTENANCE MENU Screens
PAD DATA
Initialize PAD data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Select Yes
and press ENTER to start.
HUB DATA
Initialize HUB data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Select Yes
and press ENTER to start.
TEST1 1/5
→ ALL TEST
OBJECTIVE
1 [ ]
2 [ ]
3 [ ]
4 [ ]
5 [ ]
6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Select item
and press enter to start.
VERSION
T-RCP REMOTE CONTROL PAD
V1.00 Sum=1234
T-HUBC HUB CONTROLLER
MAIN-cpu: V1.00 Sum=5678
SUB-cpu : V1.00 Sum=ABCD
CONTROL DATA
Initialize all control data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Select Yes
and press ENTER to start.
MAINTENANCE MENU
1.Version
2.TEST1
3.TEST2
4.PAD Data
5.HUB Data
6.Control Data
a.All Control Data
b.Revoiving Nosepiece
c.Condenser Cassette
d.Light Path
e.Filter Block
f.Exciter Filter
g.Barrier Filter
h.AUX filter
Control Data
Initialize Control data
for AUX filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Select Yes
and press ENTER to start.
・
・
・
・
・
・
[
]
key
MODE key

I Preparations
1 Connecting and Setting Electrical Components
- 13 -
I
I
Preparations
1 Connecting and Setting Electrical Components
(1) Connecting Electrical Components to HUB Controller
Make sure that the power switches for the microscope and the HUB controller are OFF.
Connect the electrical components to be used to the HUB controller.
Revolving nosepiece
(Motorized nosepiece)
A
nalyzer
(Motorized analyzer)
Excitation filter changeover
(Ex filter wheel)
Episcopic illumination
shutter
(Motorized Epi-fl attachment)
Barrier filter changeover
(BA filter wheel)
Filter block changeover
(Motorized cassette
holder)
Condenser module
changeover (Motorized
condenser turret)
T-EFN Focus Knob
PC
External device
(XY stage, etc.)
Uniblitz shutter
controller
Remote control pad
Dia-Illumination lamp power supply
(TS2-PS100W power supply)
* TE-PS30 and TE-PSE30 power
supplies cannot be connected.
Foot switch, etc.
[Connector panel of HUB controller]

I Preparations
1 Connecting and Setting Electrical Components
- 14 -
(2) Turning ON the EXTERNAL Switch of Dia-Illumination Lamp Power Supply
[Rear panel of dia-illumination lamp power supply]
Note:
When the EXTERNAL switch is OFF, you cannot operate the dia-illumination lamp on the remote control pad.
A 30-W power supply cannot be connected to the HUB controller.
(3) Placing Uniblitz Shutter Controller into N.C. Mode
Be sure to set the controller to the N.C. mode when using the Uniblitz shutter.
Turn the switch of the channel used to N.C.
UNIBLITZ
[Front panel of Uniblitz shutter controller]
Note:
N.C. stands for Normal Close.
If the Uniblitz shutter controller is set to the N.C. mode, when power is turned on, the controller starts up with the
shutter closed.

I Preparations
2 Setting Attachment Information
- 15 -
I
2 Setting Attachment Information
Start up the remote control pad and set the optical members attached to the electrical components in use.
The LCD indicates information for the set optical members.
(1) Objective
Set the information on objectives attached to the revolving nosepiece (motorized nosepiece).
1 Press the MODE key, and the SETTING MENU screen will
appear on the LCD.
Select “Objective” using the Skey or the Tkey and then
press the [] key.
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Series” for the objective using the PREV or NEXT
key.
Note:
The numbers at the left of the screen represent the
addresses of the revolving nosepiece.
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][―――――――――――――――][-]
2[――――――――――][―――――――――――――――][-]
3[――――――――――][―――――――――――――――][-]
4[――――――――――][―――――――――――――――][-]
5[――――――――――][―――――――――――――――][-]
6[――――――――――][―――――――――――――――][-]
Edit Type N.A. W.D.
Dry 0.13 17.10
3 Move the cursor using the Wkey or the Xkey.
Select “Mag.” for the objective using the PREV or NEXT
key.
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][DL 4x][-]
2[――――――――――][―――――――――――――――][-]
3[――――――――――][―――――――――――――――][-]
4[――――――――――][―――――――――――――――][-]
5[――――――――――][―――――――――――――――][-]
6[――――――――――][―――――――――――――――][-]
Edit Type N.A. W.D.
Dry 0.13 17.10
4 (When the TE2000-E and T-ND6-E sextuple motorized
DIC nosepiece are used together)
Move the cursor using the Wkey or the Xkey.
Select “Esc.” for the objective using the PREV or NEXT
key.
* : The objective automatically lowers to the Escape
position, returning to the original position after the
objective switch is made.
- : The objective switches with no Escape/Refocus
movement.
■Note:
Rotating past a “*” when switching from one objective
set to “-” another set to “-” will trigger an automatic
Escape.
Although “*” is set, no Escape/Refocus movement is
performed for TE2000-U and TE2000-S.
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][DL 4x][-]
2[――――――――――][―――――――――――――――][-]
3[――――――――――][―――――――――――――――][-]
4[――――――――――][―――――――――――――――][-]
5[――――――――――][―――――――――――――――][-]
6[――――――――――][―――――――――――――――][-]
Edit Type N.A. W.D.
Dry 0.13 17.10

I Preparations
2 Setting Attachment Information
- 16 -
5 Move to the next address of the revolving nosepiece using
the Skey or the Tkey. Repeat steps 2 and 3 above.
OBJECTIVE
Series Mag. Esc.
1[P Fluor ][DL 4x][―]
2[――――――――――][―――――――――――――――][-]
3[――――――――――][―――――――――――――――][-]
4[――――――――――][―――――――――――――――][-]
5[――――――――――][―――――――――――――――][-]
6[――――――――――][―――――――――――――――][-]
Edit Type N.A. W.D.
―――――――――― ――――― ―――――
6 Press the MODE key to end the setting and to return to the
OPERATION screen.
Note:
If the revolving nosepiece is not connected, you cannot set the information on objectives.
“---------” indicates that no objective is attached or registered at the address.
If an attached objective is not listed among the presets, register it to the list of optional objectives.
For details, see V-7 (2) Objective in section V-7 (Registering Data for Optical Members).
(2) Condenser Module
Set the information on condenser modules attached to the condenser module changeover (motorized condenser
turret).
1 Press the MODE key, and the SETTING MENU screen will
appear on the LCD.
Select “Condenser” using the Skey or the Tkey and
then press the [] key.
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the condenser module using the PREV
or NEXT key.
If the condenser module is marked “A,” select “BF.”
Note:
The numbers at the left of the screen represent the
addresses of the condenser module changeover.
CONDENSER
Name
1[BF ]
2[――――――――――]
3[――――――――――]
4[――――――――――]
5[――――――――――]
Edit
3 Move to the next address of the condenser module
changeover using the Skey or the Tkey. Repeat step
2 above.
CONDENSER
Name
1[BF ]
2[――――――――――]
3[――――――――――]
4[――――――――――]
5[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to the
OPERATION screen.
Note:
If the condenser module changeover is not connected, you cannot set the information on condenser modules.
“---------” indicates that no condenser module is attached or registered at the address.
If an attached condenser module is not listed in the presets, register it to the list of optional condenser modules.
For details, see V-7 (2) Condenser Module in section V-7 (Registering Data for Optical Members).

I Preparations
2 Setting Attachment Information
- 17 -
I
(3) Filter Block
Set the information on filter blocks attached to the filter block changeover (motorized cassette holder).
1 Press the MODE key, and the SETTING MENU screen will
appear on the LCD.
Select “Filter” using the Skey or the Tkey and then
press the [] key.
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the filter block using the PREV or NEXT
key.
Note:
The numbers at the left of the screen represent the
addresses of the filter block changeover.
FILTER
Name
1[UV-1A ] EX : EX365/10
2[――――――――――] DM : DM400
3[――――――――――] BA : BA400
4[――――――――――]
5[――――――――――]
6[――――――――――]
Edit
3 Move to the next address of the filter block changeover
using the Skey or the Tkey. Repeat step 2 above.
FILTER
Name
1[UV-1A ] EX : ――――――――――
2[――――――――――] DM : ――――――――――
3[――――――――――] BA : ――――――――――
4[――――――――――]
5[――――――――――]
6[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to the
OPERATION screen.
Note:
If the filter block changeover is not connected, you cannot set the information on filter blocks.
“---------” indicates that no filter block is attached or registered at the address.
If a filter block attached is not in the presets, register it to the list of optional filter blocks. For details, see V-7 (3)
Filter Block in section V-7 (Registering Data for Optical Members).

I Preparations
2 Setting Attachment Information
- 18 -
(4) Excitation Filter
Set the information on excitation filters attached to the excitation filter changeover (EX filter wheel).
1 Press the MODE key, and the SETTING MENU screen will
appear on the LCD.
Select “Exciter” using the Skey or the Tkey and then
press the [] key.
SETTING MENU
Objective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the excitation filter using the PREV or
NEXT key.
Note:
The numbers at the left of the screen represent the
addresses of the excitation filter changeover.
EXCITER
Name
1[EX465-495 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
3 Move to the next address of the excitation filter
changeover using the Skey or the Tkey. Repeat step
2 above.
EXCITER
Name
1[EX465-495 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to the
OPERATION screen.
Note:
If the excitation filter changeover is not connected, you cannot set the information on excitation filters.
“---------” indicates that no excitation filter is attached or registered at the address.
If an attached excitation filter is not listed in the presets, register it to the list of optional excitation filters. For
details, see V-7 (5) Excitation Filter in section V-7 (Registering Data for Optical Members).
If any of the openings in the changeover is empty (i.e., in the DIA position) when switching from one excitation filter
to another, a bright light may enter the observation side, depending on the layout of the optical members,
temporarily affecting your vision. To prevent this, we recommend that you attach excitation filters to the
changeover, as shown below.
Sample layout of excitation filters
1
2
3
4
5
6
7
8
Set Address 8 to DIA (empty).
A
ttach excitation filters from Address 1 forward,
leaving no empty openings in-between.
Put a light shielding plate on the openings
with no filter attached.
Excitation filter changeove
r
(
EX filter wheel
)
[Excitation filter attaching side]
Table of contents
Other Nikon Remote Control manuals
Popular Remote Control manuals by other brands

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries RCN-E1R installation manual

Flying Industry Development
Flying Industry Development 0020027 quick guide

Rane
Rane DRZH user guide

LG
LG AN-MR500G owner's manual

Universal Remote
Universal Remote Medius TX-1000 brochure

TEUCER
TEUCER LR-TW quick start guide