1) Optional accessories / Option depending on model
Original instruction
9
Operating instructions
The SB Station is a selfservice vacuum cleaner suitable for pick-
ing up dry, non-flammable dusts normally encountered when
cleaning the inside of motor vehicles. Liquids and health-endan-
gering dusts must not be picked up.
The pictorial quick reference guide
The pictorial quick reference guide is designed for helping you
when starting up, operating and storing the unit.
Before starting
DO READ SAFETY INSTRUCTIONS BEFORE USE!
Description (fig. 1)
Operating elements:
1 Hose retractor
2 Coin verifier
3 Suction hose fitting
4 Crevice nozzle
5 Suction unit
6 Dirt tank
7 Main switch
8 Adapter ring
9 Lock for coin verifier slot
10 Distance basket
11 Cloth insert filter
Unpacking and preparing the unit
• Release the SB Station from the pallet. NOTE! Do not throw
the packaging carton away. The drilling pattern for mounting
the SB Station is printed on the carton. (Fig. 2)
• Open the door.
• Take the suction hoses out of the housing.
• Lift the suction unit with the brackets and secure in place.
(Fig. 3).
• Take out the dirt tank and the accessories in the tank.
Setting up the unit:
• The machine is very heavy. Please see table with technical
data in this manual. For installation of the machine can be
lifted by two persons. however care should be taken to avoid
tilting.
• To secure stability, the machine must be fixed to a stable
ground. This can be done by e.g. bolting the machine to the
ground. It must be secured, that the machine is protected
towards vibrations, shocks and bumps.
• Mount the SB Station in the intended position using the
installation materials supplied. NOTE! Ensure that the SB-
Station is mounted on flat, level ground. If necessary:
• Level using shims!
• Check that the door opens and closes easily!
Have the electrical connection made by a qualified electrician:
• Lay the lead (above 15 m, use lead with 2.5 mm² cross-
section) along the bottom of the SB Station. Lay the lead
into the terminal box and connect as shown in the circuit
diagram.
Fitting the suction hoses:
SB Station and SB Station Marathon:
• Insert the suction hose from the outside through the hose
opening (approx. 80 cm, measured from the inner edge of
the hose opening to the end of the suction hose). (Fig. 4).
SB Tandem and SB Tandem Marathon:
• First fit the suction hose for cleaner A (Fig. 5).
• Insert the suction hose from the outside through the hose
opening. For - Cleaner A approx. 80 cm - Cleaner B approx.
80 cm measured from the inner edge of the hose opening to
the end of the suction hose.(Fig. 4).
• Fit the adapter ring (Fig. 1, No. 8) over the connection on the
dirt tank. NOTE! The connecting elbow opening should point
upwards.(Fig. 5).
• Screw adapter fitting (Fig. 6, Item 2) approx. 35 mm onto
suction hose (Fig. 6, Item 1). Plug adapter fitting with suction
hose into connecting elbow (Fig. 6, Item 3). NOTE! Push the
suction hose into the housing only far enough that the suc-
tion unit can still swing freely when the suction hose is con-
nected. This is important so that the suction unit fits airtight
onto the dirt tank when lowered.
• Secure the suction hose with the metal bracket. (Fig. 7).
• Secure the hose bracket to the suction hose approx. 1.30 m
from the end of the hose. (Fig. 8).
• Remove screw from clamping piece and detach rope end.
Guide the rope through the eye at the hose holder. Hook
up rope end to clamping piece and secure with screw.
(Fig. 9).
• Screw the crevice nozzle onto the end of the hose (left-hand
thread).
Optional accessories:
• Hose holder It is also possible to operate the SB Stationwith-
out the hose retractor. Secure the hose holder to the existing
bores with screws. After work, the hose is simply placed into
the hose holder. (Fig. 10). Art. No. 43064.
• CAUTION! Either the hose holder or the hose bracket
should be installed as otherwise the suction hose han-
dling is restricted.
Electronic coin tester:
• Allows the SB Station to be operated with different coins. On
request.
Switching on the unit
• Place the dirt tank into the station and lower the suction unit.
• Fit the suction hose with the adapter ring over the connec-
tion of the dirt tank.
Open the cover for the coin tester tube:
• Pull the knob and turn through 90° - the cover can now be
opened (Fig. 11).
• Pull up the cover until it is horizontal and secure with the flap
holder (Fig. 12).
• Set the desired running time per coin at rotary knob 1 of the
timer. (Fig. 13): 1 = 1 minute 10 = 10 minutes (Rotary knobs
2-4 are required only with electronic coin tester).
Close the cover for the coin tester tube:
• Push down the cover and turn the knob through 90° - the
latching pin engages. It is possible to secure access to the
coin box with a padlock (not included in the scope of supply)
(Fig. 14).
• Turn the main switch to position ‘I’. (Fig. 1, item 9). To check
the function, the suction turbine starts briefly. If the turbine
does not start, remedy the cause --> See section “Trouble-
shooting”.
The following functions are active when the station is
switched on:
SB-Station and SB-Station Marathon:
• Insert a coin.
• The pulse counter counts the number of coins inserted.
• At the end of the preset time, the suction turbine switches off.