Ninglu AM706 User manual

0
Website:www. ninglutech.com
Anemometer AM706
Operation & Installation Manual
Document: NLT-AM706-SSEN
Edition: V120619

Quick operating guide
Power drops alarm
There will be an alarm when one of the power supplies drops off.
Press any key to mute the alarm.
[ F ] key
Select display mode:
Heading mode
True wind mode
Gust mode
[ S ] key
Select wind speed unit: m/s, km/h, knots, mph.
Turn off
Press ▲ ▼ at the same time to turn off.
Press any key to turn on.
Calibration (Page 8)
After power on, hold the wind vane to the direction of the bow line,
then push the button in the junction box.

Contents
Quick operating guide...................................................1
Introduction....................................................................1
System composition ........................................................1
Theory description...........................................................2
Function..........................................................................3
NMEA0183 format..........................................................4
Operation........................................................................5
Specifications ................................................................6
Maintenance...................................................................7
Calibration......................................................................8
Installation......................................................................9
Operator unit ...................................................................9
Power adapter.................................................................9
Sensor unit....................................................................10
Junction........................................................................12
AM706 system diagrams...............................................12
AM706 main unit wiring diagram ...................................13

1
Introduction
The Marine Anemometer AM706 is a combined instrument for wind speed
and wind direction. It can measure relative wind speed (accuracy ±5%),
relative wind direction (display accuracy 10 °, output accuracy ±1 °). With
inputting GPS (RMC) data, user can choose heading, true wind, or gust
mode.
System composition
The AM706 includes Operator unit and Sensor unit.
Operator unit
Red ring of 36 LEDs show relative wind direction, yellow ring of 36 LEDs
show wind direction variation
The first line 3 digital LEDs show relative/true (True wind mode is selected)
wind speed
The second line 3 digital LEDs show Heading/True wind direction (True wind
mode is selected)/Max relative wind speed in interval time (Gust mode is
selected).
Sensor unit
Wind speed sensor
Wind speed sensor has a rotor with three wind cups
Wind direction sensor
Wind direction sensor has a wind vane to drive an absolute angle sensor unit
Junction box
Consist of waterproof junction box and sensor unit transmitter

2
Instruction
Theory description
The wind speed sensor has a rotor with three wind cups which spins as the
wind moves past the boat. The Wind speed sensor measures how fast the
rotor is spinning to calculate the wind speed.
The wind direction sensor has a wind vane which points in the direction that
the wind is coming from. The wind direction sensor electronically senses the
direction the wind vane is pointing.
With inputting GPS (RMC) data, user can choose heading, true wind mode,
or gust mode. If precise true wind speed and direction information are needed,
please input GYRO(HDT)and SPEEDLOG(VHW)through NMEA0183
concentrator (NMEA912) .

3
Function
Alarm
Form
explain
Error alarm
Shows “ERR” when the operator unit
receives no signal or the signal is not a
NMEA message.
Shows “_ _ _” when the message is incorrect
Shows “….” when receiving other message
Power drops alarm
Shows PL and buzzer warns when one of the
power supplies drops
Press any key to mute the alarm
RMC input baud rate: Auto receive 4800, 9600, 19200, 38400bps
HDT/VHW input baud rate: 4800 bps through NMEA912
Direction and speed output: 4800bps
Data input: RS422 (interface standard), NMEA0183

4
NMEA0183 format
Output from AM706 to other marine equipments:
$--MWV,x.x,a,x.x,a,A*hh<CR><LF>
1) Wind Angle, 0 to 360 degrees
2) Reference, R = Relative, T = True
3) Wind Speed
4) Wind Speed Unit, K/M/N
5) Status, A = Data Valid
6) Checksum
Input from GPS or NMEA912 to AM706:
$--RMC,hhmmss.ss,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,xxxx,x.x,a*hh<CR><LF>
1) UTC Time
2) Status, V = Navigation receiver warning
3) Latitude
4) N or S
5) Longitude
6) E or W
7) Speed over ground, knots
8) Track made good, degrees true
9) Date, ddmmyy
10) Magnetic Variation, degrees
11) E or W
12) Checksum
Input from Gyro to NMEA912:
$--HDT,x.x,T*hh<CR><LF>
1) Heading Degrees, true 2) T = True 3) Checksum
Input from Speedlog to NMEA912:
$--VHW,x.x,T,x.x,M,x.x,N,x.x,K*hh<CR><LF>
1) Degress True
2) T = True
3) Degrees Magnetic
4) M = Magnetic
5) Knots (speed of vessel relative to the water)
6) N = Knots
7) Kilometers (speed of vessel relative to the water)
8) K = Kilometers
9) Checksum

5
Operation
Turn on/off Press any key to turn on.
Press ▲ ▼ at the same time to turn off.
Set backlight Press ▲ or ▼ to set backlight for display
Select wind speed unit
Press [ S ] to select the wind speed unit:(m/s, knots, km/h, mph).
Choose display mode
Press [ F ] to select the display mode :
Heading mode shows H(Chart 1)
True wind shows T(chart 2)
Gust mode shows Max (Chart 3)
After selecting the gust mode, press [ F ] again and ▲or▼ to select the
interval time value: 1/2/5/10 min.(Chart 4)
Chart 3
Chart 1
Chart 4
Chart 2

6
Specifications
Dimension: W 196 x H202 x D 64mm
Cutting window: W169 x H169mm
Weight: Operator unit 2kg, Sensor unit 10 kg
Main/Emergency power supply: 24VDC (20-32V)
Main power can connect to 110/220V 50/60Hz AC through an adaptor
Power consumption: less than 5W (24 VDC)
Sensor unit measurement: Height 838mm, activity radius 550m
Operating temperature:
Operator unit -15°C~+55°C
Sensor unit -15°C~+85°C
Storage temperature:
Operator unit -20°C ~+70°C
Sensor unit -20°C~+85°C
Humidity:
Operator unit 10%-90% relative humidity
Sensor unit 10%-100% relative humidity
Sensor unit protection:IP 56
Technical parameter
The range of the wind speed 1.2~25m/s
The accuracy of the wind speed ±5% (min: 0.1m/s)
The range of the wind direction 0~359°
The accuracy of the wind speed ±1°
Min start wind speed ≤1.2m/s

7
Maintenance
Operator unit
The unit is maintenance-free.
Clean the operator unit with a damp cloth or mild detergent. Avoid abrasive
cleaners, petrol or other solvents.
Do not allow water to leak into the unit.
Sensor unit
Check the sensor unit, installation bolts and cable periodically.
If the bracket of sensor unit is moved, please calibrate again.
(Please refer to the CALIBRATION page P8 for detail).
Please contact NINGLU local dealer for after-sales service.

8
Calibration

9
Installation 安装说明
Operator unit
The unit can be mounted on panel, table, wall or ceiling.
1. For table, wall or ceiling mounting use the supplied bracket from NINGLU.
2. For panel flush mounting, take off the bracket and the front frame.
Cut a 169x169mm size square window in the panel, fix the inside 4 holes
with self-tapping screws, and put on the front frame again.
Power adapter

10
Installation
Sensor unit
Wind vane and wind cups assembly
Put the wind vane at the top of the bracket, install as the following order:
black O-ring, flat washer, spring washer, two nuts, one cotter pin. The two
nuts must be screwed tightly and cotter pin locked.
Put the wind cups at the bottom of the bracket, then install as the following
order: flat washer, spring washer, two nuts, one cotter pin. The two nuts must
be screwed tightly and cotter pin locked.

11
Installation
Sensor unit installation
Ensure that the sensor unit is mounted high enough to avoid any
interference from obstacle. The fixed pillar/pipe diameter should be 60mm
and make sure the activity radius 550mm.
After the installation of operator unit and sensor unit, calibration must be
taken. Please refer to the CALIBRATION page P8 for detail.

12
Junction
AM706 system diagrams

13
Junction
AM706 main unit wiring diagram
Other manuals for AM706
2
Table of contents
Other Ninglu Measuring Instrument manuals