2Signet 525 Metalex Flow Sensor
Caution / Warning / Danger
Indicates a potential hazard. Failure to follow all warnings
may lead to equipment damage, injury, or death
Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during
installation and service of Signet products.
Pressurized System Warning
Sensor may be under pressure, take caution to vent
system prior to installation or removal. Failure to do so
may result in equipment damage and/or serious injury.
Note / Technical Notes
Highlights additional information or detailed procedure.
Refer to your local Georg Fischer Sales office for the most
current warranty statement.
All warranty and non-warranty repairs being returned must
include a fully completed Service Form and goods must be
returned to your local GF Sales office or distributor.
Product returned without a Service Form may not be
warranty replaced or repaired.
Signet products with limited shelf-life (e.g. pH, ORP, chlorine
electrodes, calibration solutions; e.g. pH buffers, turbidity
standards or other solutions) are warranted out of box but not
warranted against any damage, due to process or application
failures (e.g. high temperature,
chemical poisoning, dry-out) or
mishandling (e.g. broken glass,
damaged membrane, freezing
and/or extreme temperatures).
Thank you for purchasing the Signet line of Georg Fischer
measurement products.
If you would like to register your product(s), you can now
register online in one of the following ways:
• Visit our website www.gfsignet.com.
Under Service and Support click on
Product Registration Form
• If this is a pdf manual (digital copy), click here
Location of Fitting
Sensor Mounting Position
Warranty Information
Product Registration
Safety Information
Recommended sensor
upstream and downstream
mounting requirements.
45°
45°
• Horizontal pipe runs: Mount
sensor in the upright (0°) position
for best overall performance.
Mount at a maximum of 45° when
air bubbles are present.
Do not mount on the bottom of
pipe when sediments are present.
• Vertical pipe runs: Sensor must be
mounted in lines with UPWARD
flow only.
1. Do not remove from pressurized lines.
2. Do not exceed maximum temperature and pressure
specifications.
3. Pipe fitting must be installed by certified welder only.
4. Do not install/service without following installation
instructions (see sensor manual).
5. Wear safety goggles and face shield during installation
and service.
6. Do not alter product construction.
7. Failure to follow safety instructions could result in severe
personal injury!
15x I.D. 5x I.D. 20x I.D. 5x I.D.
40x I.D. 5x I.D. 50x I.D. 5x I.D.
Reducer 90° Elbow
2 x 90° Elbow
3 dimensions Pump/Valve
25x I.D. 5x I.D.
2 x 90° Elbow
Maintenance
The 525 sensor requires little or no maintenance of any kind,
with the exception of an occasional sensor/paddlewheel cleaning.
Paddlewheel Maintenance:
Paddlewheel flow sensors are subject to wear and may require
maintenance and replacement of mechanical parts (rotors,
pin, bearings, retainers, etc.). The frequency of recommended
maintenance will vary based upon application specifications,
characteristics of the measured fluid, and installation details.
These can include, but are not limited to: process flowrate,
occurrence of water hammer, fluid corrosiveness and
abrasiveness, sensor installation relevant to other equipment.
GF Signet offers individual replacement parts and rotor
replacement kits, which include replacement instructions,
allowing customers to perform field maintenance and reduce
application down-time. Please refer to the Paddlewheel
Replacement section (page 4) or contact your local GF Sales
Representative with any questions.
Sensor Removal Procedure
1. Depressurize and drain pipe.
2. Remove the four sensor flange bolts and lock washers.
Pull upward on the sensor flange with an alternating
twisting motion.
WARNING!
Do not remove from pressurized lines.
Wear safety goggles and faceshield
during installation/service.