1. Caution
2
http://www.emico.co.kr
ELECTRICAL SHOCK HAZARD
To avoid serious personal injury, property damage or death, turn off
all power to the actuator before removing the cover.
Before installation or use, verify the nameplate information to
insure the correct model number, torque, voltage and enclosure type.
Be sure to completely review the actuator manual prior to operation.
Final limit switch adjustment must be done after mounting the actuator
to the valve. Incorrect adjustment may cause actuator failure.
Over torque switches are factory set. Tampering with the over torque switch
settings may damage the actuator and void the warranty.

3Emico Noah
SA SERIES MANUAL
2. Storage
Improper storage of the actuator will void the warranty.
The actuator enclosure is made from an anodized aluminum alloy which is also
polyester painted to help protect against oxidation.
Storage Location Indoor
18℃ ± 5℃
Storage Temperature
Temperature 20℃ ~ + 70℃
IP67Weatherproof
3. Actuator Specification
The actuator must be stored in a clean, dry and temperature controlled area.
The actuator shall be stored with the cover installed and with the conduit openings sealed.
Storage must be off the floor. Care must be taken to guard the actuator from condensation during
extreme temperature variation. The heater should be energized as soon as the actuator is installed.

4Emico Noah
NOAH ACTUATION CO.,LTD.
4. Standard Specification
5. Performance
Enclosure
Ambient Temperature
Power Supply
Limit Switches
Travel Angle
Indicator
Manual Operation
Space Heater
Cable Entries
Lubrication
Materials
Surface Treafment
External Coating
Weatherproof Enclosure IP67 Nema 4 and 6
-20℃ to +70℃
DC24V, AC24V
AC110 / 230V 50/60Hz
Open / Close + Dry Contact Open / Close (250AC 5A)
0˚~ 90˚
Dome Type With LED illumination
6mm hexagon "L" wrench handle included
2 x 3W
2- PF1/2"
Option: 2-M20x1.5, 2-NPT1/2”
Shell Gadus S2 V220 2
Aluminium alloy
Anodizing
Polyester (TGIC-free)
MODEL MAIN
POWER
OUTPUT
TORQUE
OPERATING
TIME(90˚)
NUMBER
OF
HANDLE
TURNS
WEIGHT
Kg.m N.m 50Hz 60Hz kg
SA003 3 30
in-lb
261
17sec 15sec
15sec
7.5 1.7
lb
3.8
AC 120V
AC 110V
AC 230V
AC 220V
AC 24V
DC 24V
47
40
36
33
23
35
MODEL MAIN
POWER
RATED CURRENT (A)
1 PHASE(AC) DC
DUTY CYCLE
POWER
CONSUMPTION
S2 (min) S4 (%)
W
SA003 50151 0.4 0.16 1.4
AC 120V
AC 110V
AC 230V
AC 220V
AC 24V
DC 24V
24V 110V
0.4
120V
0.16
220V 230V 24V

5Emico Noah
SA SERIES MANUAL
6. Exterior Parts Identification
Top Cover
Top Cover
Bolts
Cable entries
Earth
Body
Base
L-Wrench
Manual
Sealing Bolt
Window

6Emico Noah
NOAH ACTUATION CO.,LTD.
7. Interior Parts Identification
Full Open / Close
LED Lamp
Terminal
Earth
Motor
Control Board
Heater (2EA)
Indicator
Micro Switch
Auxilliary Open Limit Switch
Auxilliary Close Limit Switch
Close Limit Switch
Open Limit Switch

7Emico Noah
SA SERIES MANUAL
8. Actuator Mounting Flange
SA003 Base is manufactured to the ISO 5211 standard.
If the actuator does not fit directly to the valve, drive inserts are available or complete
mounting kits can be supplied as request.
Mounting Base B.C.D
ISO 5211 F03(Φ36 M5TAP DP8)
ISO 5211 F04(Φ42 M5TAP DP10)
ISO 5211 F05(Φ50 M6TAP DP10)
9. Actuator Installation
Model A(mm)
Ground
A
SA003 80
When installing the actuator, proper clearance around the actuator is required to ensure.
Drive Insert (Option)
11 DP20

8Emico Noah
NOAH ACTUATION CO.,LTD.
10. Manual Operation
11. Limit Switch Setting
11-1 Cam Switch Calibration
10-1 Remove the manual sealing bolt using
the wrench attached on the bottom of the actuator.
10-2 Turn the wrench to the clock wise for opening and
count clock wiser for closing inserting the wrench.
10-3 Screw up the manual sealing bolt to protect the actuator
from leakage and put the wrench in its regular place
after use not to lose.
11-1-1
Loosen the close cam set screw and rotate the
cam in a clockwise direction to actuate the close
limit switch. Also, the close auxiliary switch cam
can be adjusted at this way too.
11-1-2
Firmly tighten the cam set screws.
11-1-3
To set the open cam switches, repeat the previous instructions except rotate the actuator to the open,
counter clockwise position and rotate the open cams in the counter clockwise direction to actuate
the open switches.
ACLS
AOLS
OLS
CLS
Dry Open Limit Switch
Dry Close Limit Switch
Open Limit Switch
※ L-wrench Size: 2.5mm
Close Limit Switch
AOLS
OLS
ACLS
CLS

12. Indicator Setting
The position of the valve is indicated by the visual dome indicator.
LED lights illuminate to allow for easy visual confirmation of full close and full open
※If the position of the indicator is not aligned correctly, an adjustment can be made
by simply loosening the bolt and manually turning the indicator to the proper location,
then re-tightening the bolt
Bolt
Indicator
Window
13. Wire Connection
The conduit entries on the SA003 actuator are M20, PF1/2”, NPT1/2” as request.
So there maybe some differences as to the thread and pitch standards.
Check with your supplier to confirm which standard is supplied in your area.
Standard conduit and conduit seal fittings may be used when installing and wiring the actuator.
To prevent moisture and humidity from entering the actuator, it is highly recommended
that a seal fitting be installed in the actuator conduit entry.
After all the conduit and wiring has been completed, then the seal fitting can be sealed with packing
and or a potting material.
13-1
Any unused conduit entry must remain plugged with the pipe plug provided withthe actuator.
Do not remove the remaining plug as it is already sealed.
13-2
9Emico Noah
SA SERIES MANUAL

14. Electric Wiring
14-1
14-2
14-3
14-4
Remove the actuator cover by loosening the four captive cover bolts.
Confirm that the wiring diagram located in the actuator and the wiring number on the
nameplate match correctly.
Confirm that the main power and supply described on the nameplate of the actuator match
correctly.
Connect the wire to the terminal strip according to the
wiring diagram provided. The SA003 actuator uses
the push type PCB Screw terminal block.
The push type strip makes wiring connections easy
and also helps to protect against pipeline vibration.
Wire
※ PCB Screw terminal block JK128, Max:3.5㎟
14-5 Be sure to properly ground the actuator
by using the earth screws provided on the
inside and outside of the actuator body.
14-5 Be sure to wire and energize the heater as shown in the wiring diagram.
14-6 Each actuator must be powered by their own individual relays to prevent voltage
feedback and actuator damage.
14-7 After the wiring is completed in the actuator, use wire ties to group the wires together
and clean up their appearance. Be certain that the wires are secure and away from any
moving parts. Remove any loose debris before replacing the cover.
14-8 When all the work is completed, remount the top cover and secure it using the four cover screws.
14-9 Apply power and do a final check to confirm proper operation.
Main power must only be applied when the top cover is remounted on the
actuator body. If the main power is on while wiring the actuator,
stop work immediately and turn the power off, only then is it safe to proceed.
Interior / Exterior earth / ground terminal
10 Emico Noah
NOAH ACTUATION CO.,LTD.

16-1
17-1
16-2
16-3
16-4
16-5
16-6
16-7
It is recommended that the actuator be cycled every two weeks after purchase.
To minimize the effects of condensation in the actuator, conduit entries should be sealed
properly and the heaters should be energized regularly.
15. Maintenance
16. Warranty Void Information
Failure or damage caused by misuse or abuse.
17. Warranty
One year limited warranty from the factory release date.
Failure or damage caused by unauthorized modifications or repairs done to the actuator.
Failure caused by the unauthorized modification / change or the wiring.
Failure caused by water entering the actuator due to improper sealing of the cable entries.
Failure caused by improperly set limit switches.
Failure caused by fire, flood damage or other "Acts of God".
Failure occurring more than one year after shipment date.
11 Emico Noah
SA SERIES MANUAL

18. Wiring
19. Dimension
CLS : Close Limit Switch (250VAC 3A)
OLS : Open Limit Switch (250VAC 3A)
ACLS : Aux Close Limit Switch (250VAC 3A)
AOLS : Aux Open Limit Switch (250VAC 3A)
NOAH ACTUATION CO.,LTD.
12
http://www.emico.co.kr
SA003 BASE
11 20
9
130
50
114132.5
80
Cable Entries
※Option
1. 2-M20x1.5
2. 2-NPT1/2”
2-PF1/2”
11 DP20
Drive Insert (Option)
Table of contents
Other NOAH ACTUATION Controllers manuals
Popular Controllers manuals by other brands

oventrop
oventrop Aktor M ST operating instructions

Baccara
Baccara G75-DFC Installation operation & maintenance

WEIHONG ELECTRONIC
WEIHONG ELECTRONIC Ncstudio Programming manual

SOMFY
SOMFY Animeo KNX RS485 operating manual

Azbil
Azbil Infilex ZM WY5122 Specifications & instructions

PXM
PXM Wireless DMX manual