NOBOCOOL Ecohub User manual

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 1/41
USER MANUAL
NoboEnergyControlsystemautomaticallycontrolselectricheaters,lights,andother
electricalappliancesaccordingtoindividuallydefinedweeklyprograms.
Thesystemwillhelpyoureduceenergybills,andmakeyourhouseholdmoreeco
friendly,withoutcompromisingyourcomfort.
BEFORE YOU START
ThischapterwillgiveyouessentialknowledgeoftermsandconceptsusedintheNobø
EnergyControlsystem.
HOW DOES NOBØ ECOHUB WORK?
NobøECOHUBisthecentralunitintheNobøEnergyControlSystem.The
ECOHUBcontrolsheaters,lightsandotherelectricalappliancesaccordingtoyourown
weeklyprograms.
ECOHUBisconnectedtoyourwirelessnetworkandcommunicateswithNobøEnergy
ControlAPPonyoursmartphoneortablet.FromtheAPP,yourhomeiscontrolled
accordingtoyourneedsandwishes.
Youcancontrolyourhomefromanywhereintheworld,aslongastheappisconnected
totheInternet.
WHAT IS A RECEIVER?

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 2/41
WHAT IS A RECEIVER?
NOBØECOHUBsendsradiosignalstoRECEIVERSthatcanbeplacedinheaters,power
outletsorfuseboxesaroundyourhome.EachreceiverhasauniqueIDcodeenabling
ECOHUBtosendsignalstothecorrectunit.
NOBØECOHUBiscompatiblewithallNOBØOrion700receiversandNOBØNCU
receivers,butnotwithNOBØOrion512receivers.
LIST OF RECEIVERS
NCU1RisareceiverforNobøheatersNFandNT,controllablebyECOHUB.COMFORT
temperaturesettingisonthereceiver(heater).ECOtemperatureissetwiththeNOBØ
EnergyControlAPPinterface.
NCU2RisareceiverforNobøheatersNFandNT,controllablebyECOHUB.COMFORT
andECOtemperaturesareseteitheronthereceiver(heater),orwiththeNOBØEnergy
ControlAPPinterface.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 3/41
NCUERisareceiverforNobøheatersNFandNT,controllablebyECOHUB.COMFORT
andECOtemperaturesaresetwiththeNOBØEnergyControlAPPinterface.
DCU1RisareceiverforDimplexheatersDFandDT,controllablebyECOHUB.
COMFORTtemperaturesettingisonthereceiver(heater).ECOtemperatureissetwith
theNOBØEnergyControlAPPInterface.
DCU2RisareceiverforDimplexheatersDFandDT,controllablebyECOHUB.
COMFORTandECOtemperaturesareseteitheronthereceiver(heater),orwiththe
NOBØEnergyControlAPPInterface.
DCUERisareceiverforDimplexheatersDFandDT,controllablebyECOHUB.
COMFORTandECOtemperaturesaresetwiththeNOBØEnergyControlAPPInterface.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 4/41
R80RDC700isareceiverforNobøheatersC2/C4,B4,T4,P4/P6andR3/R5,
controllablebyECOHUB.COMFORTandECOtemperaturessettingsareonthereceiver
(heater).
R80RXC700isareceiverforNobøheatersC2/C4,B4,T4,P4/P6andR3/R5,
controllablebyECOHUB.Thisreceiverhasnolocalcontrols.COMFORTandECO
temperaturesaresetwiththeNobøEnergyControlAPPinterface.
R80RSC700isareceiverforNobøheatersC2/C4,B4,T4,P4/P6andR3/R5,
controllablebyECOHUB.COMFORTtemperaturesettingisonthereceiver(heater).ECO
temperatureissetwiththeNOBØEnergyControlAPPinterface.
R80TXF700isareceiverforNobøheatersC2/C4,B4,T4,P4/P6andR3/R5.R80TXF
700canbecontrolledbyECOHUBviaaroomthermostat(TCU700orTXB700).
COMFORTandECOtemperaturesarethensetontheroomthermostat.
R80TXF700canalsobecontrolleddirectlybyECOHUB,ifthereisanECOSWITCH
temperaturesensorinthesamezone.COMFORTandECOtemperaturesarethensetin
theAPPinterface.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 5/41
2NC9700isareceiverforDimplexandewtheaters2NC8,2NW5and2NW6.COMFORT
temperaturesettingisontheheater,whileECOtemperatureissetinNobøEnergy
ControlAPPinterface.
TRB36700isacombinedfloorandroomthermostat,andeffectregulatorforwallbox
mounting.COMFORTandECOtemperaturesaresetonthereceiver(thermostat).
TXB700operatesasacentralroomthermostatinaroomwithoneormoreNobø
C2/C4,T4,P4/P6,R3/R5andSafirglassheaters.Thisthermostatcontrolsupto10
heatersintheroomviaradiosignals.COMFORTandECOtemperaturesaresetonthe
receiver(thermostat).
TR36isacombinedfloorandroomthermostatforonwallmounting.COMFORT
temperatureissetonthereceiver(thermostat).ECOtemperatureissetintheAPP
interface.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 6/41
RSX700isarailmountedrelayreceiverfordirectcontrolofelectricloads.Signalsfrom
ECOHUBswitchestheloadsonandoff.
RS700isaflushmounted10Areceiverthatswitchestheloadonandoffaccordingto
signalsfromECOHUB.
RCE700isa10Acontrolunitforpoweroutlets,thatswitchestheloadonandoff
accordingtosignalsfromECOHUB.Possibleusesarelightsandotherapplianceswitha
powercord,includingheaters.COMFORTtemperatureissetontheheater.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 7/41
TCU700isabatterypowered,wireless,roomthermostatcontrollingNOBØSafirGlass
HeatersandNOBØheaterswithR80TXFradioreceiver.TCU700communicateswiththe
heatersthroughradiosignals,andcanbeconnectedtoECOHUB.COMFORTandECO
temperaturesaresetonthereceiver(roomthermostat).
Safirisaglassheaterwithanintegratedradioreceiver.ECOHUBcancontrolSafirviaa
roomthermostat(TCU700orTXB700).COMFORTandECOtemperaturesaresetonthe
roomthermostat.Asanalternative,ECOHUBcancontrolSafirdirectlyifthereisan
ECOSWITCHtemperaturesensorinthesamezone.Inthiscase,COMFORTandECO
temperaturesaresetintheAPPinterface.
TouchisaconvectionheaterwithintegratedreceiverforECOHUB.COMFORTandECO
temperaturesaresetontheheater.
WHAT IS A TRANSMITTER?

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 8/41
WHAT IS A TRANSMITTER?
AtransmittercommunicatesmessagestoECOHUBuponcertainevents,likeoperatinga
switchpanel.Atransmittercanalsobeasensor(temperature,magnetswitchesetc.)
thatautomaticallycommunicateseventsandstatustoECOHUB.
LIST OF TRANSMITTERS
ECOSWITCHSW4enablesyoutomanuallysetyourhometoNORMALstatus,or
temporarilyoverrideyourhometoCOMFORT,ECOorAWAY.SW4hasthesame
functionalityasthehomescreen(circlemenu)inNOBØEnergyControlAPP.
WHAT IS A ZONE?
Receiversthataresupposedtofollowthesameweeklyprogramandtemperature
settings,shouldbeplacedtogetherinaZONEintheAPP.Oneexamplecouldbeallthe
heatersinyourlivingroom.AZONEissimplyagroupofreceiversoperatinginthesame
manner.
Heaters/thermostatsshouldnotbeplacedinthesamezoneaslightsorotherappliances.
Oneroomcanconsistofseveralzones,andonezonecanincludereceiversindifferent
rooms.
Allreceiversinazoneshouldpreferablyhaveequalfunctionality.Ifazonehasbotha
heaterconnectedtoasimpleON/OFFreceiver(e.g:RCE700)andalsoanotherheater

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 9/41
withanadvancedreceiver(e.g:R80RDC700),thesimplerreceiverwilllimitthe
functionalityinthezone.Thetwoheatersshouldeachbegivenaseparatezone,tobe
abletoexploitthefunctionalityoftheadvancedheater.
Applianceswithspecialpatternsofuse(e.g.engineheaters)shouldeachhavea
separatezone.Nameeachzoneforeasyrecognition.
ThisapartmenthasbeendividedintofourZONES,eachnamedforeasyrecognition.Eachreceiver
canonlybeincludedinoneofthezones,sinceitcanonlyfollowoneweeklyprogramatatime.
WHAT IS A WEEKLY PROGRAM?
EachZONEmustbegivenaWEEKLYPROGRAMtellingthereceiversinthezonehowto
actduringaweek.ForeachdayoftheweekyoucanspecifyperiodsasCOMFORT,
ECO,AWAYorOFF,andthereceiverswillreactaccordingly:
COMFORT
YourpreferredCOMFORTtemperatureisseteitherontheheater,orinNOBØEnergy
ControlAPP,dependingonyourtypeofreceiver.
ONOFFreceiverswillbeONwhenthezoneisinCOMFORTstatus.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 10/41
ECO
YourpreferredECOtemperatureisseteitherontheheater,orinNOBØEnergyControl
APP,dependingonyourtypeofreceiver.
ONOFFreceiverswillbeOFFwhenthezoneisinECOstatus.
AWAY
AWAYtemperaturisfixedto7°Candcannotbealtered.ONOFFreceiverswillbeOFF
whenthezoneisinAWAYstatus.
OFF
Allreceiversareswitchedoffcompletely.
SYSTEM SETUP
ThischapterexplainshowtoinstallNOBØECOHUB,andhowtoaddreceiversandother
systemunits.
ECOHUB SETUP
Importantinfo:
NobøECOHUBcommunicateswithwirelessradiosignals.ECOHUBmustbemountedon
awallforoptimalrange.Somebuildingmaterials,likereinforcedconcrete,massive
timberetc.mayreducethesignalrange.Inthecaseofsignalsnotreachingareceiver,
movingtheECOHUB12metrestothesidecouldbeenoughtoavoidtheobstacle.
Installthesystem,andmakesureallyourreceiversreactproperly,beforefinalmounting
oftheECOHUBonthewall.
Systemsetup:

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 11/41
ConnectthepowercordtotheECOHUBandplugitintoapoweroutlet.
ECOHUBmustbeconnectedbycable(ethernetcable)toalocalnetworkwitha
wirelessrouter.Thecablecanbeconnecteddirectlytotherouter,ortoawalloutlet
elsewhereinthebuilding.
Makesureyoursmartphoneortabletisconnectedtothesamewirelessnetworkand
startNOBØEnergyControlAPP.Whenconnectedtopowerandalocalnetwork,
ECOHUBwilltransmititsIDcodeonthewirelessnetwork.
ToinstallECOHUB,followtheAPPsetupwizard.TheAPPwillsearchforanECOHUB,
anddisplaytheresultsonthescreen.PresstheIDcodecorrespondingtoyourECOHUB.
IfmorethanoneECOHUBisconnectedtothesamewirelessnetwork,thecorrectone
mustbeselectedinthesetupwizard.ChecktheIDcodeatthebackofthe
ECOHUBandselectthecorrespondingIDintheAPP.
(NB!OnlyoneECOHUBcanbeinstalledatatime.)
Forsecurityreasons,youwillbeaskedtotypeinthe3lastdigitsofyourECOHUBID
code.TheIDcodeisatthebackofyourECOHUB.
DonotmounttheECOHUBonthewalluntilthesetupisfinished.Incaseyouneedto
checktheIDcodeagain.
CONTROL VIA THE INTERNET

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 12/41
CONTROL VIA THE INTERNET
WhentheapphasbeenconnectedtoanECOHUBonalocalnetwork,theappcanalso
beoperatedremotelyviatheInternet.
Thesystemsecurityisbasedonyourlocalnetworkbeingprotectedfromunauthorized
access.Pleasemakesureyourlocal,wirelessnetworkispasswordprotectedagainst
intruders.Becarefulwhenallowingotherstoaccessyournetwork.Anyonewhohas
connectedtheirapptoyourECOHUB,willlaterbeabletocontrolitremotelyviathe
Internet.
WhentheappandtheECOHUBconnectviaalocalnetwork,theyautomatically
exchangeencryptionkeys.Thisistoensureasecure,encryptedcommunicationviathe
InternetbyarobustAESencryption.Theencryptionkeysaregeneratedbytheapp,and
aresavedintheappandtheECOHUBtopreventanyonlinesurveillance.
IfyoudonotwishtocontrolyoursystemviatheInternet,the"Allowcontrolvia
Internet"optioncanbeswitchedoffunder“Settings”.Thisoptioncanonlybechanged
whenconnectedtothelocalnetwork.IftheInternetcontroloptionisswitchedoffand
thenbackonagain,allprevioususers(apps)areresetfromaccessingtheECOHUBvia
theInternet.Toregainaccess,theappandtheECOHUBmustexchangenew
encryptionkeys.Thisisdonesimplybystartingtheappwhileconnectedtothelocal
network.
ADVANCED ECOHUB SETUP
IfthesearchforECOHUBinthesetupwizardfails,andnoHUBsarefound,press
“advanced”toinstalltheECOHUBmanually.
Foradvancedinstallation,youwillneedtheIPaddressallocatedtotheECOHUBonyour
network.TheIPaddresscanbefoundbyloggingontotherouter.Seeyourwireless
routermanual,oraskyourinternetserviceproviderformoreinfo.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 13/41
Intheadvancedsetupscreen,enterboththeIPaddressANDtheentire12digitID
codefromthebackofyourECOHUB,andpress“verify”.
Ifunsuccessful,pleasecheckthefollowing:
(onlyrelevantforuserswithspecialnetworkconfiguration)
Makesurethereisnofirewallbetweenyourwirelessandcablednetwork(TCPtraffic
mustbeallowedonport27779.)
Makesureyourwirelessnetwork(connectedtotheAPP)isthesamelogicallocal
network(LAN)asyourcablednetwork(connectedtotheECOHUB)
MakesureyournetworkallowsUDPbroadcasttraffic(onIP255.255.255.255,port
10000).
ADDING RECEIVERS AND TRANSMITTERS
WhenNobøECOHUBhasbeenregistered,othersystemunits(receiversand
transmitters)canbeadded.Select(+)“Addnew>systemunit”inthemainmenu.
Toinstallreceivers,switchpanels,sensorsetc.,theirIDcodemustberegisteredbythe
APP.Thiscanbedoneintwoways:
MANUAL REGISTRATION
Manualregistration1.
Automaticsearch2.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 14/41
Select“(+)Addnew”inthemainmenu,select“systemunit”andthen“manual
registration”.
TheIDcodeisa12digitnumberprintedonthereceiver.Enterthisnumberintothe
textboxesonthescreen.Press“+”toentermoreunitsatthesametime.Itisadvisedto
registeronlyonezoneatatime.
TheNOBØECOproductrangealsohastheIDcodeprintedasQRcode.TheQRcode
canbescannedfromtheAPP.
Orion512productsarenotcompatiblewithECOHUB.
Batterypoweredreceiversortransmitters(TCU700,ECOSWITCH)needpairingwiththe
ECOHUBiftheIDcodehasbeenaddedmanually.Duringtheinstallation,theAPPwill
notifyyouwhenaunitneedspairing.
Theunitisactivatedforpairinginthesamewayasforautomaticsearch.Seetheunit
usermanualformoreinformation.
AUTOMATIC SEARCH
AllNobøECOproducts,plusafewOrion700products(R80RSC700,R80TXF700,
TCU700roomthermostat,Safirglassheater)canconnecttotheAPPandECOHUBby
automaticsearch.
Select“automaticsearch”intheAPP.Next,youwillbeaskedtoswitchonyoursystem
unit,andtheunitwillsenditsIDcodetoECOHUB.Morethanoneunitcanbe
connectedatonce.Justswitchononeunit,andcheckthatitappearsintheAPP
overviewbeforeswitchingonanother.Thesearchcanbepausedifneeded.
Itisadvisedtoregisteronezoneatatime.
HOW TO SWITCH ON A RECEIVER/TRANSMITTER FOR
AUTOMATIC SEARCH

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 15/41
NCU1R,NCU2R,NCUER:inserttheunitintotheheater.Turntheheater’spower
switchfromOFF(0)toON(1).
R80RSC700,R80TXF700:inserttheunitintotheheater.Turntheheater’spower
switchfromOFF(0)toON(1).
TCU700:Pressandholdtherightbuttonuntilthemenuappears.Pressdownandselect
EC700.Presstherightbuttonagaintoconfirmtheselection.TCU700willthenconnect
toyourECOHUBorOrion700controlunit.
Safir:Turntheheater’spowerswitchfromOFF(0)toON(1).
ECOSWITCHSW4:Pressthecenteroftheswitchonce,sothatallfourcornersare
presseddown.TheswitchlightflasheswhilesearchingforECOHUB

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 16/41
R80RDC700ogR80RXC700:Requiremanualregistration.
2NC9700:Requiresmanualregistration.
TRB700,TXB700:Requiremanualregistration.
RCE700,RS700ogRSX700:Requiremanualregistration.
Touch:Requiresmanualregistration.
NAME AND ASSIGN UNITS TO A ZONE
WhenoneormoreIDcodesareregistered,eachunitshouldbegivenaname.Entera
namethatiseasytorecognise.E.g.“HeaterDiningroom”,“TowelheaterBath”etc.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 17/41
Everyunitmustbeassignedtoazone.Aunitwillbeaddedtothepreviouslyselected
zone,unlessyouchooseadifferentzoneinthedropdownmenu.Anewzonecanalso
beaddedviathedropdownmenu.Givethezoneanamethatiseasytoremember.E.g.
“HeatLivingroom”.
REMOVING SYSTEM UNITS
Allsystemunits(receiversandtransmitters),zonesandweeklyprogramsyouhave
addedyourself,canberemovedfromtheECOHUBifneedbe.TheDefaultweekly
programcannotbedeleted.
Removereceivers/transmitters
Receiversandtransmittersareremovedbypressing inthemenu,andselecting
SystemUnit.Selectoneormoreunitsforremoval.
Removezones
Press inthemenu,andselect Zone.Selectoneormorezonesforremoval.NB!
All
receivers/transmittersinthezonewillberemovedaswell.
Removeweeklyprogram
Press inthemenu,andselectWeeklyProgram.Selectoneormoreprogramsfor
removal.
Zonesusingaremovedprogramwillreturntothedefaultprogram(factorysettings).
TheDefaultprogramcannotbedeleted.
REMOVE ECOHUB
RemovingECOHUBfromanAPPmeanstheenergycontrolsystemcannolongerbe
controlledbythisparticularphoneortablet.Otherphonesortabletsconnectedtothe
sameECOHUBwillnotbeaffected,andcanstillbeusedasnormal.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 18/41
ToremoveECOHUB,select inthemenu,andthen ECOHUB
MENUS AND FUNCTIONS
ThischapterwillexplainthescreensintheAPP,andwheretofindthevariousfunctions.
STATUS AND ZONES
TheHOMEscreeninNobøEnergyControlAPPisdividedintwoviews:STATUSand
ZONES.Swipesidewaystonavigatebetweentheviews.
STATUSview(Circlemenu)isthemaincontrolofyourhousehold,andshowsactive
status.Whenthecenterofthecircleisgreen,yourhomeisinNormalstatus.Thismeans
allzonesautomaticallyfollowtheirindividualweeklyprograms.TheCirclemenuallows
youtooverrideyourhometo“COMFORT”,“ECO”,or“AWAY”whenneeded.Thecircle
showstheactivestatusingreen.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 19/41
SwipinglefttakesyoutotheZONESview,listingallthezonesinyourhome.Tapazone
bartodisplaythesystemunitswithinthezone.Toenterthesettingsscreenforazone,
tapthewrenchicon.
Othermenuitemsareplacedundermenubuttontopleft.
OVERRIDES
Ifyouarrivehomeearlierthanexpectedonacoldwinterday,ORtravelsomewherefor
theweekend,ORgoonholidayfortwoweeks,thenormalweeklyprogramcaneasilybe
changedtemporarily.Thisiscalledanoverride.
Anoverrideinterruptsthenormalweeklyprogram,replacingitwiththeselectedstatus
“COMFORT”,“ECO”or“AWAY”foralimitedtime.
NobøEnergyControlhasfourtypesofoverrides:CONSTANT,NOW,FROMTO,and
TIMER.
Override:CONSTANT
ACONSTANToverridewilllastuntilyouchoosetostopitmanually.Theoverrideisuseful
ifthetimeforreturntoNormalstatusisuncertain.

4/14/2016 SkriverBrukermanualDigitalbrukermanual
http://help.nobo.no/skriver/?chapterid=344&chapterlanguageid=2 20/41
Override:NOW
ANOWoverridewilllastuntilthereistobeastatuschangeintheNormalweekly
program.Astheweeklyprogramchangesstatus,theoverrideisterminatedandthe
systemreturnsautomaticallytoNormalstatus.Inthecaseofaweeklyprogramwithno
statuschanges,aNOWoverrideisterminatedat3AM.
Override:FROMTO
AFROMTOoverrideallowsyoutoselectdateandtimeforwhentheoverridestartsand
stops.
Override:TIMER
ATIMERoverridelaststhenumberofdaysandhoursselected.DefaultTIMERdurationis
2days(48hours)unlessyouchangeit.
SIMPLE OVERRIDES
IntheHOMEscreen,thecirclemenuallowsyoutooverrideallyourzonestoanystatus
“COMFORT”,“ECO”,or“AWAY”foralimitedtime.Youcanterminateanoverrideatany
timebypressing“Normal”atthecentreofthecircle.
Comfort
Asingletapon”COMFORT”startsaNOWoverride.TheNormalweeklyprogramisput
onhold,andallzoneschangetoCOMFORTstatus.Theoverrideisterminated
automaticallywhenallthezoneshavechangedstatusonce.Inthecaseofaweekly
programwithnostatuschanges,theNOWoverrideisterminatedat3AM.Whenthe
zoneshavechangedbacktoNormal,thecentreofthecirclemenuwillturngreen.
AnoverridecanbeterminatedatanytimebypressingNormaloradifferentoverride.
Table of contents
Other NOBOCOOL Control System manuals