nologo START-S4XL User manual

START-S4XL
START-S4XL_290113_VXX13_GB www.ebtechnology.it www.nologo.info
FUSE 5A FUSE 200mA
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 2 3 4 5 6 7 8 9 10
230Vac
20
40
60
80
100 0
2
68
MAX
4
10
MIN
2
68
OFF
4
10
FORCE PHASE
DISPLACEMENT
SLOW
DOWN
TIMES
CODE
DIP A DIP B
Reset of the control board:
Press button “CODICI” and “TIMES”
for 10 seconds
OPEN
CLOSE
CODES
230 Vac Phase
230 Vac Lamp
230 Vac Lamp
Motor 1 COMMON
Motor 1 OPEN
Motor 1 CLOSE
Motor 2 COMMON
Motor 2 OPEN
Motor 2 CLOSE
Open. Limit Switch Mot. 2
Clos. Limit Switch Mot.1
Closing photocell
Start Button
24Vac
24 Vac/12Vac elect. lock
12Vac electrical lock
STOP
PEDONALE Botton
Photocell always working
COMMON contacts -
Antenna +
Earth -wire
Light / Lamp.
Light / Lamp.
Fototest 24Vac
12Vac
24Vdc +
COM 24Vdc -
26 27 28 29 30 31
1 2 3 4 5 6 7 8
DIP C
Remove of the inputs
• Single phase for 230 Vac 2 motors
• Universal control unit for 1 or 2 motors swing
• 4 limit switches
• Separate slow down
Clos. Limit Switch Mot. 2
Open. Limit Switch Mot.1
433,92 Mhz
Radio-decode
Radio-receiver

2
Slow down
Working times learning
Eletrical adjust of the force of the motor
4 functions (apartment block included).
Functions set up throught a dip
Free contact for light indicating the open gate
Radio included which can manage codes rolling.
Small dimensions
Pedestrian door (partial opening) with separate command
Electrical lock and selecting reversing stroke
Dip esclusione di tutti gli ingressi di sicurezza.
Inputs exclusion limit switches with a DIP
The START S4XL control board is designed to move gates. It can be
connected to an oleodinamic motor or electro-mechanical motor with a
single-phase motor, in 230 Vac.
1.2 Field of application
1.1 Description of the product
Making the correct choice of installation is essential to ensuring adequate
safety and good protection against atmospheric agents. Remember that
the control unit contains powered parts and electronic components which
bytheirverynaturearesensitivetoinltrationsandmoisture.Thecontrol
unit is supplied in a container which guarantees an IP55 protection rating
if adequately installed. Install the control unit on a permanent surface that
isperfectlyat,adequatelyprotectedagainstimpactsandatleast40cm
off the ground. The cables must enter the control unit from the bottom
only; we recommend using wire leads and water-tight connections.
Whenusingtubingthatcouldllupwithwaterorifthetubingcomesfrom
anundergroundwell,thewiresmustenterarstshuntingboxplacedat
the same height as the control unit and then, from there, the wires must
be passed into the container holding the control unit, again entering from
the bottom. This prevents any evaporation of the water in the tubing from
forming condensation inside the control unit itself.
2.1 Preliminary checks
Remember that systems for automatic gates and doors must be installed
byhighlyqualiedtechniciansonlyandinfullcompliancewithcurrent
law. Before starting installation, check that the mechanical consistency
and sturdiness of the gate or door, check that the mechanical stops are
suitable to stop the movement of the gate or door even if the electrical
limit switches should fail or during manual operations.
2 Installation
1 Introduction
START-S4XL is the ongoing evolution of the START-S4 electronic control
unit, completely compatible and equipped with a sophisticated electronic
circuit that controls the motive force, detecting any obstacles at any point
in its operation.
The design has adapted the most advanced techniques to guarantee
utmostimmunityvs.noise,maximumoperatingexibilityandtomakea
wide choice of functions available.
Foreword
Thismanualprovidesallthespecicinformationyouneedtofa-
miliarize yourself with and correctly operate your unit. Read it
very carefully when you purchase the instrument and consult it
whenever you have doubts regarding use and before performing
any maintenance operations.
Safety precautions
Usingtheunitimproperlyandperformingrepairsormodications
personally will void the warranty.
Nologo declines any responsibility for damages due to inappro-
priate use of the product and due to any use other than the use
the product was designed for.
Nologo declines any responsibility for consequential damages
except civil liability for the products.
Environmental protection
measures
Information regarding the environment for customers
within the European Union. European Directive EC
2002/96 requires that units bearing this symbol on the
unit and/or on the packaging be disposed of separate-
ly from undifferentiated urban wastes. The symbol in-
dicates that the product must not be disposed of with
the ormal household wastes. The owner is responsible for dis-
posing of this product and other electrical and electronic equip-
mentthroughspecicwastecollectionfacilitiesindicatedbythe
government or local public agencies. Correct disposal and recy-
cling help prevent any potentially negative impact on the environ-
ment and human health. To receive more detailed information
regarding disposal of your unit, we recommend that you contact
the competent public agencies, the waste collection service or
the shop where you purchased the product.
Small legend
LSO - FCA limit switch open
LSC - FCC limit switch closed
START control to drive the gate
PEDESTRIAN in sliding units: control partial opening
Vac alternate current
Vdc direct current
NC normally closed
NA normally open
Isolated contact isolated from power supply

3
2.2 Type of electrical wires
According to the installations , to the type and the quantity of the cables, the wires can be different, in the table is shown
the necessary cables for a standard installation.
The installation cables should be conformed to the IEC 60335 norm.
Power supply cable Cable 3x1,5 mm2
Motor cable (if it is not required) Cable 4 x 1,5 mm2
Lamp cable Cable 2x1,5 mm2
Antenna type RG58 Cable RG58
Cable for key selector Cable 3x0,5 o 0,75 mm2
Cable for Photocell ‘s receiver Cable 4x0,5 o 0,75 mm2
Cable for Photocell’s transmitter Cable 2x0,5 o 0,75 mm2
2.3 STANDARD INSTALLATION
2.4 Notes on connections
To guarantee operator safety and to prevent damaging the components, never make connections or insert wireless recei-
ver boards while the control unit is powered.
• Power the control unit through a 3 x 1.5 mm2cable. If the distance between the control unit and the ground sy stem
connection is more than 30 m, a ground plate must be installed in proximity to the control unit.
• If the motors do not have a cable, use the 4 x 1.5 mm2cable (open + close + common + ground).
• In connecting the part with an extremely low safety voltage, use cables with a minimum section of 0.5 or 0.75 mm2.
• Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit
• Do not connect the cables in underground cases even if they are water-tight.
• If they are not used, the inputs to the Normally Closed (NC) contacts must be jumpered to the “common”.
• If the same input has more than one contact (NC), they are placed in series.
• If they are not used, the inputs to the Normally Open (NO) contacts are left loose.
• If the same input has more than one contact (NO), they are to be placed in series.
• The contacts must be mechanical and free of any potential.
•
Rememberthatsystemsforautomaticgatesanddoorsmustbeinstalledbyhighlyqualiedtechniciansonlyandinfull
compliance with current law.
It is important to make an important risk analysis of the “ MACHINE” and of the customers requirements in order to decide
how many products should be installed.
All NOLOGO photocells dispose of a synchronisation system which permit to avoid any interference between two couples
of photocells (look the photocell’s instructions for details)
In the diagram , photocells “FOTO A” in opening they have no effect, while it provoque a complete inversion during
closing. “FOTO A2” is the serial connection of “FOTO A” or “ALT, FOTO B” is the photocell working by closing and
opening.
Installation for sliding gatesInstallations for swing gates
FOTO A
FOTO A2FOTO B
FOTO A

When the control board is powered, the lights “ l.e.d. are situated in the outputs, they are switched on when on the output
there is a closed contact to the common.
Normally the red l.e.d. in the inputs “Closing limit switches” (FCC) , “opening limit switches”(FCA), STOP, FOTO
are always SWITCHED ON.
Normally the green l.e.d. in the inputs START and PEDONALE (partial opening) are switched OFF
2.5 Description of the connections
4
230 Vac Neutral 1230 Vac electrical power supplì 50 Hz Neutral
EARTH 2EARTH
230 Vac Phase 3230vac electrical power supply 50 Hz Phase
Lamp 4OutputsforLAMP(ashinglightelectroniccard)or230VACCOURTESYLIGHT
Lamp 5
M 1 Com 6Output for the connection of motor 1 COMMON POLE M 1
M 1 Opening 7Output for the connection of motor 1 POLE OPEN MOTOR 1
M 1 Closing 8Outputs for connections motor no.1 pole CLOSE
M 2 Com 9Output to connect motor no.2 pole common M2
M 2 Opening 10 Output to connect motor no.2 pole OPEN M2
M 2 Closing 11 Output to connect motor no.2 pole CLOSE
FCC M2 12 Input Closing limit switches motor no.2
FCA M2 13 Input Opening Limit Switches 2
FCC M1 14 Input for Closing limit switches of motor no.1
FCA M1 15 Input for opening limit switches of Motor 1
Photocells A 16 Input Photocell A , working only by closing (see chapter 2.3)
START 17 Input for step-by-step function START
24Vac 18 Output for 24 Vac
24Vac / 12Vac 19 Output for electrical lock 12 Vac 50 Hz 1A
12Vac Lock 20 Output for electrical lock 12 Vac 50 Hz 1A
STOP 21 Pedestrian Stop input
PEDONALE 22 Input for step-by-step function PEDESTRIAN partial opening
Photocells B 23 Input for photocells B working in Closing and in opening (see chap. 2.3)
Common 1 - 24 Common for all inputs: services, Securities, coaxial antenna cable sock.
Antenna + 25 Input for antenna (antenna cable)
light or lamp 26 Contact for Light or LAMP (without electronic card)
light or lamp 27 Contact for Light or LAMP (without electronic card)
PHOTOTEST 28 Output TEST FOR PHOTOCELL 12 Vac
12Vac 29 Output 12Vac
24Vdc + 30 Output 24Vdc +
Comm. 24Vdc - 31 Output 24Vdc - Common for inputs: services and safety

1 3 230 Vac control board power supply
4 11 230 Vac motors power supply and 230Vac lamp
12 18 Accessories power supply and services and securities inputs
19 20 Output for 12 Vac 50 Hz 1 A electrical lock, is powered for 3 seconds only by opening
21 25 Commands, safeties, antenna
26 27 Freecontactforlightindicatingopengateorlampwithoutashingcard.
28 31 Fototest and accessories tension and inputs for services and safeties.
TIMES button for working time learning and setting up of “ VELOCE ”( fast) of the pause –time. For
PEDESTRIAN ( partial opening ) learning time keep pressed till the opening of the MOTOR 1
CODES button to memorize the codes in the receiver( cancellation of the memory and codes learning)
FORCE MOTOR FORCE ADJUST
20% TO 100%
PHASE-DIS.
Setting up of the TIME PHASE DISPLACEMENT DOORS by opening and closing: Departing minimum
speed of 1 sec and , if adjusted at the maximum power, the door opens when the second door has
nishedtheworkingtime.Innextopeningwillthenewvaluevalid(0Max).
SPEED
SLOW
DOWN
Setting up of the speed of the slow down and remove of the slow down. (MINIMUM _OFF). For the most
part of the motors set up the speed at about 1/3 of the normal speed of the motor. TO remove the slow
down, turn the trimmer in OFF.
LED
OPENING
Signal lamp to indicate the status of the automation (see diagram)LED
CLOSING
LED CODES
2.6 Connections and setting up
5
OPEN
CLOSE
CODES
Theledforcodesashes:
The gate is closed
led indicating the opening
is switching on:
The gate is opening
ledinopeningashes:
The gate is in opening
slow down
led by closing is switched
on: The gate is closing
ledinclosingashes:
The gate is slowing down by
closing
ledopeningandclosingashes:
The gate is open and stop
led opening and closing and l.e.d. codes
ashes:
Fast setting up of the pause time
OPEN
CLOSE
CODES
OPEN
CLOSE
CODES
OPEN
CLOSE
CODES
OPEN
CLOSE
CODES
OPEN
CLOSE
CODES
OPEN
CLOSE
CODES

Thecontrolboardhasseveralmicro-switchestoactivatealotoffunctionsinordertondsuitablesolutionsfortheuserandtomakethe
installation more safety.
3 Functions and adjustments
3.1 Use of the DIP A
1 2 3 4 5 6 7 8 9 10
DIP A
1-OFF 2-OFF automatic 1 By every order it inverts: open and close. It closes automatically at
the end of the pause time
1-ON 2-OFF condominium
shared property operation by opening and pause time it doesn’t
accept commands. it recloses automatically at the end of the pause
time
1-OFF 2-ON semi-automatic By every command it follows the procedure open-stop-close-stop-
open etc. It doesn’t re-close automatically
1-ON 2-ON automatic 2 By every command it follows open-stop-close-stop-open etc. It
recloses automatically at the end of the pause time
3
4
5
6
8
9
10
12
7
3
4
5
6
8
9
10
12
7
3
4
5
6
8
9
10
12
7
3
4
5
6
8
9
10
12
7
3-ON REVERSING
STROKE
This function starts a closing thrust at the beginning or at the end of
the manoueuvre to make easy the work of the electrical lock.
4-ON Courtesy light
In the output of the terminal board 4 and 5 there is tension at the
beginning of the opening till 2 minutes before closing, useful to
power the courtesy light.
5-ON Pre-lighting It able the pre-lighting before each manouevre.
6-ON It takes the
passage
taken form the photocells, the control board open completely then
closes but 1 sec. before according to the pause time , without any
obstacle.
7-ON Lamp in pause time the lamp is working in the pause time, too
8-ON Phototest activate the phototest (Cap. 6)
9-ON Fixed light Theoutputofthelampindicatingtheopenedgateisxedinsteadof
ashing
10-ON
Programming
time, advanced
system
It activate the time learning with an advanced system (see diagram)
3
4
5
6
8
9
10
1
2
7
3
4
5
6
8
9
10
1
2
7
4
6
8
9
10
1
2
7
4
5
8
9
10
1
2
7
4
5
6
8
9
10
1
2
4
5
6
9
10
1
2
7
4
5
6
8
10
1
2
7
4
5
6
8
9
1
2
7
5
3
6
3
3
3
3
3
7
8
9
10
6

3.2 Setting up with DIP B
1 2 3 4 5 6 7 8 9 10
DIP B
1-ON *man present
This function can able the “ Man present” function, The START com-
mand opens the closing PEDONALE command. The motors stop
when the command has been released. (*see note)
2-ON Use for Industrial
gate
the PEDONALE command has closes while the START COMMAND
has the same function of the DIP 1 and DIP 2
3-ON rolling-code
Activatetherollingcodefunction.ThecontrolboardacceptsONLY
HCS rolling code remote controls and it checks the rolling code
counter. The remote controls cannote be copied. If it is enable it
4-ON controlled gradual
de part
The motors has a minimum force for the de part and they can reach
the planned values. This function is not compatible with all gates, it
should be valued according to the installation
5-ON 1 motor
ItabletheuseofONLYonemotor.Thecontrolboardmakeall
manoeuvre and the motor. No.2 work simultaneously with motor no.1
ThetimelearningisonlyforONLYmotorno.1
6-ON Opening
displacement
If you put the DIP SWITCH in ON the opening displacement will be at
2 seconds. The closing displacement can be chosen with the trimmer
“ displacement”.
7XLeave in the OFF
8-OFF
Time learning
planned from the
user
Leave in OFF when used the planning time setting up from the user ,
otherwise look on the diagram below
9-OFF
Time learning
planned from the
user
Leave in OFF when used the planning time setting up from the user ,
otherwise look on the diagram below
10-OFF
Time learning
planned from the
user
Leave in OFF when used the planning time setting up from the user ,
otherwise look on the diagram below
3
4
5
6
8
9
10
1
2
7
3
4
5
6
8
9
10
1
2
7
4
6
8
9
10
1
2
7
4
5
8
9
10
1
2
7
4
5
6
8
9
10
1
2
4
5
6
9
10
1
2
7
4
5
6
8
10
1
2
7
4
5
6
8
9
1
2
7
5
3
6
3
3
3
3
3
7
8
9
10
4
5
6
8
9
10
2
7
3
1
4
5
6
8
9
10
1
7
3
2
*(1 ON “ Man present) to go back to the normal function.
Switched off the control board and put the DIP 1 in OFF and switch on the control board again..
DIP 8 DIP 9 DIP 10 TIME “ START “ IN OPE-
NING AND CLOSING
TIME “PEDESTRIAN” IN
OPENING AND CLOSING
ON OFF OFF 10” (seconds) 6” (seconds)
OFF ON OFF 14” (seconds) 8” (seconds)
ON ON OFF 18” (seconds) 10” (seconds)
OFF OFF ON 22” (seconds) 12” (seconds)
ON OFF ON 26” (seconds) 14” (seconds)
OFF ON ON 32” (seconds) 18” (seconds)
ON ON ON 38” (seconds) 20” (seconds)
7

1 2 3 4 5 6 7 8
DIP C
remove the inputs
3.3 Setting up and enables of the inputs in the DIP C
1-ON
FCC M2
12 Exclusion of the inputs closing limit switches of motor. No.2
2-ON
FCA M2
13 Exclusion of inputs of the opening limit switches motor no.2
3-ON
FCC M1
14 Exclusion of the inputs of the closing limit switches motor no.1
4-ON
FCA M1
15 Exclusion of inputs of the opening limit switches motor no.1
5-ON
Fotocellula A
16 Exclusion of the input of photocell working in closing.
6-ON
STOP
21 Exclusion of the input STOP
7-ON
Fotocellula B
23 Exclusion input photocell always activated.
8-ON Radio
DECODE It activate the radio-receiver
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
8
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10

4 Memorisation of the remote controls
Thecontrolboardcanacceptdifferenttypeofcodes,therstmemorizedremotecontrol,denethetype,consequentely,othertypeofcodes(differentfrom
therstremotecontrol)cannotbelearnt.Thecontrolboardacceptstandardcodesfrom12to64bitandonlythexedpartofthecodefortherollingcode
HCS©, but using the DIP 13 ( 3 of DIP B) the rolling code counter can be checked. In this way the remote control cannot be copied. The memory capacity
isabout200rollingcoderemotecontrols.Therstmemorizedremotecontroldenesthetypeofcodethatthereceivershouldlearn,consequentially,the
next remote controls should have the same type of code.
This operation cancel all previous memorized codes. It is not previewed the cancellation of a single remote control
Itisnecessarytoresetthememorybeforelearningtherstremotecontrolinorderthatthepreviouslymemorizedcodescanbeusedintheinstallation.
The cancellation of the memory (all codes) is possible only when the gate is closed.
1Make sure that the gate is in closed position
2PushthecodesbuttonuntiltheL.E.D.CODICEashesANDreleaseit
Wait until the reset of the memory.
4.2 Learning of the remote control
TheremotecontrolscanbelearntONLYwhenthegateisCLOSED.
- If you need to learn a new remote control repeat the same operation
- When you push the remote control’s button and the L.E.D. codes is switched ON, it means that the remote control is not compatible.
-Whenyoupushtheremotecontrol’sbuttonandtheL.E.D.codesashesslowly,itmeansthatthememoryisFULL.
- In this card is not previewed the cancellation of a single remote control ‘s code.
4.1 FULL CANCELLATION of the memory
CODES
1Make sure that the gate is CLOSED
2Press and release the CODICI button, l.e.d. CODICI will lit on
3Pressthebuttonoftheremotecontrol,ifithasbeenmemorizedl.e.d.CODICIwillash
1PressandreleasetheCODICIbutton,theL.E.D.CODICIisxed.
2PushtheCODICIbuttonagainandtheL.E.D.CODICIashesandthenisxed.
3Press the button of the remote control for example if the button no.2 has been learnt, the L.E.D. CODES
START
CODES
PEDONALE
CODES
9

5 TIME LEARNING
The gate is in closed position
1Put in OFF the switch no. 10 of the DIP A The automation is in the CLOSED position.
2* Push the button TIMES TherstmotorOPENS
... after the phase-deplacement, automatically... ... the second motor OPENS
3Push the button TIMES (or START) (If the opening limit switches are
not available)
Therstmotorstops,waituntilthesecond
motor stops.
... If the limit switches are available, wait until both motors are
stopped.
Leave the PAUSE TIME you need.
4Push the TIMES button The second motor CLOSES
... after the phase-deplacement time... ...therstmotorcloses.
5Press the TIMES button (or START) (if the limit switches are not
available)
The second motor stops, wait until the
rst motor stops.
END OF LEARNING TIME.
... if the limit switches are available wait when both motors stop.
The second motor stop, wait until thee
rst
motor stops.
END OF LEARNING TIME
5.1 TIME LEARNING: NORMAL WAY
10
7
8
9
*AftertherstpushoftheTIMESbuttonyoucanusetheterminalboardno.17
or the remote control as START as well.
The control board START S4XL has two way to plan the working time.
NORMAL WAY: use this way when all doors are the same and the motors are the same.
ADVANCED SYSTEM: use this way when you want top lan the exactly slown down and / or the doors have different
functions ways.
TIMES
10

The gate is in closed position
1Porre e lasciare in ON l’interruttore 10 del DIP A The gate is in closed position
2 * Push the button TIMES TherstmotorOPENS
3Push the button TIMES (or START) If the slow down are active
(trimmer see. Slow down) ... Therstmotorslowsdownwhenopening
4Push the TIMES button (or START) (if the opening limit switches of
motor no.1is not available). Motor no.1 stops , the motor no.2 OPENS
4 a ... If the limit switch is available wait until the rst motor stops Motor no.1 stops, then motor no.2 OPENS.
5Push the TIMES button (or START) if thee slows down are active
(trimmer V. Slow down) ... the second motor slows down when opening
6Push the button TIMES ( or START) ( if the opening limit switches
motor no.2 is not available)
The second motor stops, it counts the pause
time.
6 a ... If the limit switches is available wait until motor no.2 stops. The motor no.2 stops, it counts the pause time.
Let the wishing PAUSE TIME runs.
7Push the TIMES button (or START) the second motor CLOSES.
8Push the TIMES button (or START) if the slow down are active
(trimmer see Slow down) the second motor slows down when closing
9Push the TIMES button (or START) ( if the closing limit switch of
motor no.2 is not available)
Thesecondmotorstops,therstmotor
CLOSES
9 a ... if the limit switch is available wait until motor no. 2 stops The motor no. 2 stops, motor no.1 closes
10 Push the TIMES button (or START) if the slow down are active
(trimmer see Slow down) The motor no.1 slows down when closing
11 Push the button TIMES ( or START ) if the closing limit switches of
motor no.1 is not available
Motor no.1 stops. End of ADVANCED
LEARNING TIME.
11 a ... if the limit switches is available wait the stop of motor no.1 Motor no.1 stops. End of ADVANCED
LEARNING TIME.
5.2 TIMELEARNING:ADVANCEDSYSTEM
10
7
8
9
TEMPI
The gate is in closed position
1Push and keep pressed the TIMES button till the motor no.1 OPENS,
then release the TIMES button. The motor no.1 OPENS
2Push TIMES button Therstmotorstops
Let the pause time run FOR THE PARTIAL OPENING.
3Push the TIMES button The motor no.1 CLOSES.
4Push the button TIMES (if the closing limit switches of motor no.1 is
not available) Motor no.1 stops. The door is closed. End
4 a ... If the limit switch is available wait until the motor no.1 (
pedestrian use) stops when closing
Motor no.1 stops by closing limit switches. The
pedestrian door is closed. End.
5.3 TIME LEARNING: WHEN PARTIAL OPENING
TIMES
11
*AftertherstpushoftheTIMESbuttonyoucanusetheterminalboardno.17
or the remote control as START as well.

The gate is in pause
1Push and release the TIMES button THE L.E.D. for opening and closing are switched on
The new PAUSE TIME run.
2Press and release the TIMES button The gate CLOSES. End of the fast learning time
and PAUSE TIME.
5.4 TIME LEARNING: Pause (fastest way)
TIMES
5.5 Cancel of the memory code of the control board
The cancellation of the control board , put the original times of the control board.
Keep pressed both PULSANTE CODICI and PULSANTE TIMES for 10 seconds till the three l.e.d. OPEN, CLOSE and
CODES are switched off. The cancellation of the memory of the control board doesn’t cancel the memorized codes: it is
two different memories.
12
6 Manuals for the TEST function
Now the control unit check the TEST
function of all devices and the the gate opens with a little bit delayed
8
6
9
10
7
8
Make all connections to the TEST as shown in the manuals
1When the control unit is turned off, put the DIP8 of DIPA in OFF position
2PowerthecontrolunitandwaittheashingoftheL.E.D.
3Put the DIP8 of DIPA in ON position
4Let the gate opens with START control or try with the memorization of the working time ( Paragraph 5.1)
The TEST function is compatible with devices with slower response ( for example TRANSCEIVER) so the opening ma-
noeuvre can be a little bit delayed. Besides you can test the devices in the STOP input.
To check that all devices are connected to the inputs FOTO, FOTOSTOP ( Photo-beam B) and STOP and if the TEST function is avail-
able, make the following procedure
9
10
7
7
7
DIP A
DIP A

13
7 Declaration of CE conformity
(according to EC Directive 98/37, Attachment II, part B)
The undersigned Ernestino Bandera,
Administrator
DECLARES THAT:
Dairago, 14 giugno 2007
The Administrator
Ernestino Bandera
THE PRODUCT COMPLIES with what is outlined in the European Community directive:
EC 98/37 (EEC 89/392 modied)
ECDIRECTIVE98/37ISSUEDBYTHEEUROPEANPARLIAMENTANDCOUNCIL
on June 22, 1998 harmonizing the legislation of the member countries regarding
machinery.
Reference: Attachment II, part B (EC Declaration of Conformity issued by the manufacturer).
THE PRODUCT COMPLIES
with what is outlined in the following European Community
directives, as modied by EEC Directive 93/68 issued by the
EUROPEAN COUNCIL on July 22, 1993
73/23/CEE withwhatisoutlinedinthefollowingEuropeanCommunitydirectives,asmodied
by EEC Directive 93/68 issued by the EUROPEAN COUNCIL on July 22, 1993
Reference to harmonized standards: EN 60335-1
89/336/CEE EECDIRECTIVE89/336ISSUEDBYTHEEUROPEANCOUNCILonMay3,1989,
harmonizing the legislation of the member countries regarding electromagnetic
compatibility
Reference to harmonized standards: EN 61000-6-2 EN 61000-6-3
THE PRODUCT COMPLIES
with the essential requirements of article 3 of the following
European Community Directive, for the use for which the
product is designed:
1999/5/CE ECDIRECTIVE1999/5ISSUEDBYTHEEUROPEANPARLIAMENTAND
COUNCIL on March 9, 1999 regarding wireless units and telecommunications
terminals and their reciprocal recognition
Rifering to the standars norms: ETSI EN 300 220-3 ETSI EN 301 489-1 ETSI EN 301 498-3
The directive 98/37/Ce remind that it is not allowed the function of the product until the machine, for which
the product is included, is not indentify and declared conformed to the 98/37/ce directive.
Company: EB TECHNOLOGY SRL
Adress: Corso Sempione 172/5
21052 Busto Arsizio VA Italy
Product’s name: START-S4XL
Single phase for 230 Vac
2 motors
EB TECHNOLOGY S.r.l.
Corso Sempione 172/5,
21052 Busto Arsizio VA Italia
tel. +39 0331.683310
fax.+39 0331.684423
posta@ebtechnology.it
www.ebtechnology.it
NOLOGO S.r.l.
via Cesare Cantù 26,
20020 Villa Cortese MI Italia
tel. +39 0331.430457
fax.+39 0331.432496
www.nologo.info

DICHIARAZIONE DI CONFORMITA’
Il sottoscritto, rappresentante il seguente cos-
truttore, dichiara che l’apparecchio denomi-
nato
START-S4XL
risulta conforme a tutte le norme tecniche
relative al prodotto entro il campo di applica-
bilità delle Direttive Comunitarie 73/23/CEE,
89/336/CEE e 99/5/CEE
Sono state eseguite tutte le necessarie prove
di radiofrequenza
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
Questa dichiarazione viene emessa sotto la
sola responsabilità del costruttore e, se appli-
cabile, del suo rappresentante autorizzato.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Amministratore
DECLARATION OF CONFORMITY
The undersigned, representative of the fol-
lowingmanifacturer, hereby certies that the
equipment known as
START-S4XL
complies with all technical requirements
concerning this product within the domain of
application of the EC Directives 73/23/CEE,
89/336/CEE and 99/5/CEE
All necessary radiofrequency tests have been
performed
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
This declaration is rendered under the man-
ifactu-rer’s sole responsability, and if appli-
cable, under responsability of his authorized
representative.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Administrator
DÉCLARATION DE CONFORMITÉ
Le soussigné, représentant du constructeur
suivant certie que les appareils ci-dessus
référencés
START-S4XL
sont conformes à toutes les normes tech-
niques relativement au produit dans le
domaine d’application des Directives Eu-
ropéennes 73/23/CEE, 89/336/CEE et 99/5/
CEE
Toutes les essais de radiofréquence néces-
saires ont été effectués
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
Cette déclaration est présentée sous la seule
responsabilié du constructeur et, si applica-
ble, de son représentant autorisé.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Administrateur
KONFORMITÄTSZERTIFIKAT
Der Unterzeichner bescheinigt, dass das
Produkt
START-S4XL
allen technischen Produktegesetzen, laut den
Europäische Gesetzen 73/23/CEE, 89/336/
CEE e 99/5/CEE, entspricht.
Alle Radiofrequenzprüfungen haben bei der
nachstehenden Firma stattgefunden:
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
Diese Bescheinigung wird unter der alleinigen
Verantwortung des Herstellers ausgestellt
und dort woanwenbar, auch unter der des be-
fugten Vertreters.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Verwalter
DECLARACIÓN DE CONFORMIDAD
Elabajormante,representanteelfabricante
siguiente, declara que el equipo denominado
START-S4XL
es conforme con todas las normas técnicas
correspondientes al producto en el campo
de aplicación de las Directivas Comunitarias
73/23/CEE, 89/336/CEE y 99/5/CEE
Han sido realizadas todas las necesarias
pruebas de radiofrequencia.
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
Esta declaración se expide bajo la exclusiva
responsabilidad del fabricante y, si de apli-
cación, de su representante autorizado.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Administrador
DECLARACÃO DE CONFORMIDADE
O abaixo-assinado, represendo o seguinte
construtor declara que o aparelho denomi-
nado
START-S4XL
é conforme a todas as normas técnicas relati-
vas ao produto dentro o campo de aplicabili-
dade das Diretivas Comunitarias 73/23/CEE,
89/336/CEE e 99/5/CEE
Foram executadas todas as necessárias pro-
vas de rádio frequência.
EB TECHNOLOGY SRL
Corso Sempione 172/5
21052 Busto Arsizio (Va)
Italia
Esta declaração verm emitida somente com a
responsabilidade do construtor e, se aplicáv-
el, do seu representante autorizado.
Busto Arsizio (Va) - Italia, 14/06/2007
ERNESTINO BANDERA
Administrador
Table of contents
Other nologo Receiver manuals
Popular Receiver manuals by other brands

Comfort audio
Comfort audio Comfort Contego T900 user manual

SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT S2T-DC06 quick start guide

Icom
Icom IC-RP1510 operating manual

CO/Tech
CO/Tech 51058GB 30 Series operating instructions

Global Sat
Global Sat EM-411 Product user manual

Rocket Fish
Rocket Fish RF-WFD301 Quick setup guide