Electrostatic Settings
Select ChargerMode
The Select Charge modes are non-adjustable
electrostatic settings. The LEDs above the Select
Charge mode buttons indicate the selected mode.
The Select Charge Modes and electrostatic setpoints
are:
Re-Coat: 100 kV, 15 μA
Metallics: 50 kV, 50 μA
Deep Recesses: 100 kV, 60 μA
Re-Coat Metallics Recesses
NOTE: If you press the STD/AFC selection button
while using a Select Charge mode, the controller
switches to STD or AFC mode. Pressing the +or −
keys have no effect in Select Charge Mode.
Custom Electrostatic Mode
Custom Mode is the default electrostatic mode. In
Custom mode, both kV and μA can be adjusted
independently. Both the STD and AFC LEDs light
when this mode is configured.
Use the View button to toggle the display
between kV and uA.
Use the +and −buttons to select the desired
setpoint. The longer a button is pressed the faster the
units change.
SThe valid STD (kV) range is 0 or 25−100 kV.
SThe valid AFC (μA) range is 5−100 μA.
Classic Electrostatic Mode
Classic Mode is the optional electrostatic mode. The
controller must be configured to use this mode. Refer
to your system manual.
In Classic mode you can choose to control kV (STD)
output or μA (AFC) output, but not both at the same
time. AFC allows you to set a top limit for current
output. As current output increases, kV output
decreases.
Press the STD/AFC button to toggle between
STD and AFC mode.
Press the View button to toggle the display
between kV and μA.
Press the +or −buttons to select the desired
setpoint. The longer a button is pressed the faster the
units change. Valid ranges for kV and μA are the
same as in Custom Mode.
Encore LT PE Mode
To configure the controller for the Encore PE system,
set function number 3 (Electrostatic Control) to
setting 2 (Encore PE).
When the controller function number 3 is set to PE,
the electrostatic settings will allow the user to control
both kV and μA (custom mode) and they will be able
to control the μA setting to values less than 3.0μA in
0.1μA increments.
Powder Flow Settings
Smart Flow Mode −This is the factory default mode.
In this mode, you set the Total Flow rate and the Flow
Air %. If you decrease the flow air %, the flow air
pressure decreases, but the atomizing air pressure
increases, so that the result is that the powder
velocity remains the same. The Smart Flow LED
lights when the controller is configured for Smart
Flow mode.
Classic Flow Mode −This is the standard method of
setting powder flow and velocity, by setting flow and
atomizing air percentages separately and balancing
them manually for optimum results. When the
controller is configured for Classic Flow mode, the
Smart Flow LED is off.