Basic Confidence Check
Once all cables have been terminated, power up the CRC200S and check that the opening screen
is displayed as follows:
C
R
C
2
0
0
m
V
x
. x
x
N
o
d
e
: N
Key: CRC200m = Clock & Data mode
CRC200w = Wiegand mode
Vx.xx = firmware version number
Node: N - this indicates the node id. where the
CRC200S is part of a network. For stand-alone
operation, this can be ignored.
Also check that the connected readers have the correct ready status displayed (refer to the
manufacturer’s handbook).
Configuring the CRC200S
The CRC200S has a wide range of configurable features. The factory default settings support
standard sequentially numbered Clock & Data cards with no additional features activated. This
guide explains how to configure only those items required for basic operation using standard
Clock & Data format cards. Refer to the CRC200S User Guide if you are using Wiegand format
cards and/or wish to activate additional features. The full menu structure is shown at the end of this
guide for general guidance.
The required basic programming actions are:
1. Set relay operation times
2. Add and validate cards as required (with or without cards available)
Once these actions have been carried out, the CRC200S is ready for basic use.
Programming
The CRC200S is programmed using the 12 buttons and the LCD display.
Note: The CRC200S is factory set to ‘210’ mode. These instructions are based on it being in
this mode. If the mode has been changed, refer to the CRC200S User Guide.
Configure Relay Operation Time
Press once and then press repeatedly until ‘Installer’ is displayed:
I n
s
t a
l l e
r
Press to enter the installer menu
C
o
n
f i g
Press to display the first parameter
C
o
n
f i g
R
e
l a
y
1
: x
x
x
>
Enter a value between 1 and 30 to set the operate time for
Relay 1 in second (or enter ‘0’ for 500ms) & then press
repeatedly until the following screen is shown:
C
o
n
f i g
R
e
l a
y
2
: x
x
x
>
Enter a value between 1 and 30 to set the operate time for
Relay 2 in second (or enter ‘0’ for 500ms) & then press
Press 3 times to exit Programming mode