The current active power monitored timely.
The power factor monitored timely.
The frequency of voltage monitored timely.
Power using time in total can be record.
Measurement of the quantity of CO2 which generated when power using.
(Notes: 0.555kg CO2 generated when 1 KWh electricenergy consumed.)
The overload threshold can be set, warning will happen when overload happened.
Displayed by LCD which with large size.
1. Plug in the powerbay set, and then plug in the power using equipments.
2. The total used energy, active power, current voltage, current, power using time in total, frequency,
and CO2 generated can displayed on LCD.
3. LCD shown the active power value continuously when power on, the backlight lighted at the same
time and will be off after 5 seconds.
4. Display when pressthe buttons: The active power value, power factor, current, voltage, frequency,
power using time in total, total used energy, and CO2 generated will displayed on LCD in cycle or
reverse cycle when press the "▼" or "▲" button.
5. Warning when overload happened When the current power exceed the limited power quota
continuously, warning will happen,backlight will blink and stopped after didn't overload for a few
times. How to set the overload threshold: Press the "▼" or "▲" button until the current power value
shown on LCD, press the "set" still for 2 seconds, nowLCD show as "XXXX W" and the rightest "X"
blinking. Press the "▼" or "▲" button untilthe blinking "X" shown as what number you want, and then
press the "OK", this bit setaccomplished. Nowthe next "X" blinking, set the following bits with the
same steps. LCD shown the current power value after threshold set accomplished. The threshold
value wouldn't more that 2200W, or else LCD will shown "Err1" for 3 seconds and the threshold
should be set again.
6. Clear the power using time in total: Press the "▼" or "▲" button until the power using time in total
shown on LCD, press the "set" still for 2 seconds, nowthe numbers on LCD blinking,press "OK",
time clear accomplished and LCD shown the power using time in total. Clear the power used in total:
Press the "▼" or "▲" button until the power used in total shown on LCD, press the "set" still for 2
seconds, nowthe numbers on LCDblinking, press "OK", clearance accomplished, and the value of
CO2 generated cleared too. LCD shown the power used in total.