Press POWER keyto switch scaleson
Use …and †keysto selectrequired denomination
Placebanknotesorcoinsofthe samedenomination onthescales.Removeto
registeracountorpress ENT
˜
keyto abort count.
When scalesare emptyENT keyisused to reset running totals:
Press ENTkeytoreset running totalsforcurrent denomination
Press and holdENTkeyto reset runningtotalsforalldenominations
Use AUTO ►keyto auto scroll denominationsand select scrolldirection:
►Lowerto higherdenomination scroll symbol
Higherto lowerdenomination scroll symbol
► Lowerto higherand backto lowerdenomination scroll symbol
Use PRINT keyto displayprint functions(section 3.0)
Press and holdPOWER keyto switchscalesoff.
2.0 SETUPMENU
Press and holdPOWERkeyto switch scalesoff
Press ESC keyto entersetup menu. When finished, press again toexit
2.1 STANDBYTIME
Tosavebatterypowerthe scaleswill enterstandbyafteraperiod ofinactivitydetermined
by STANDBY setting. Select shortest practicalstandbytime
Highlight STANDBY using ‡and ˆkeys
Change standbytime using …and †keys
2.2 LCD DISPLAYCONTRAST
Highlight CONTRAST using ‡and ˆkeys
Use …and †keysto change LCD contrast to personalpreference
2.3 BACKLIGHTTIME
LCD backlightusessignificantamountofbatterypower. Tosavebatterypowerthe
backlightwill be switched offafteraperiodofinactivitydetermined by BACKLIGHT
setting. Selectshortestpractical backlight timeor disable completely
Highlight BACKLIGHT using ‡and ˆkeys
Change LCD backlight timeusing …and †keys
2.4 SETTIMEAND DATE
Highlight SETTIME&DATE using ‡and ˆkeys
Press ENTkeytodisplaycurrent time and date
Use ‡and ˆkeystoselect time ordateand press ENTkey
Use …and †keysto change between HRS-MIN-SEC and DD-MM-YY
Press ENTkeytoset
Press PRINTkeyto displayprint menu
PrintSinglePrintrunning totalsforcurrentlyselected denomination
PrintTotalPrintgrand total
4.0 WEIGHINGSCALES
Press and holdPOWERkeyto switch scalesoff
Press ˆkeyto enterweighing scales
Use …and †keysto change engineeringunits
(Availableunits: grams,pounds, ounces)
Placeup to 3Kgofweight on thescales
Use PRINTkeyto print the result
5.0 CALIBRATION MENU
Allow5 to 10 minuteswarm-up time (scaleson)before attempting calibration
(Insetup menu,change standbytimeto15 minutesto
stop scales fromswitching off. When
finished, reducestandbytimetosavebatterypower)
If red lightis flashingconnectachargerand fullychargethe scales beforeattempting
calibration. (It isrecommendedtocalibratescalesrunning of batterypower)
Place scaleson aflat, stable surface.Donotleanormakecontactwiththe surfaceduring
calibration.Makesurethe roomis freefromstrong airdraftscaused byairconditioning or
open windows
To entercalibrationmenu, switch scalesoff and press ESCkey
Select calibration menu and press ENTkey
5.1 CALIBRATINGSCALES
Tomaintain accuracy,thescalescanbe calibrated atanytimeusing aprecise100g
weight (notincluded)
Select CALIBRATESCALES fromcalibrationmenu
Start calibration and followscreen prompts
Use ESC keyto abort calibrationat anytime
On completion, select oneoftwooptions:
Ifanybanknotesorcoinswere previouslycalibrated select
CURRENTSETTINGS otherwise select FACTORYDEFAULTS
5.2 CALIBRATINGSCOOP
Touseadifferentscoop totheone supplieditmust firstbe calibrated
Select CALIBRATESCOOP fromcalibrationmenu
Start calibration and followscreen prompts
Use ESC keyto abort calibrationat anytime
5.3 CALIBRATINGBANKNOTES AND COINS
Thescalesarecalibratedforaparticular currencyand normallydo notneedrecalibration
Forcalibration, refertoa separate document: