NOVAPRO CRYSTE PURIFUME DUCTLRESS User manual

OPERATING INSTRUCTIONS
PURIFUME_DUCTLESS
www.cryste.co.kr
READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE MACHINE
CR-RF-Ver 1.0 2017 04
www.cryste.co.kr
801, ACE hightech City B/D 2 Dong, 775, Gyeongin-ro,Yeongdeungpo-Gu, Seoul, KOREA
HEAD OFFICE ( NOVAPRO CO.,LTD. )
1204, 302-dong, SSangyoung 3rd Bucheon Technopark, 36-1, Samjung-dong,
Ojung-gu, Bucheon shi, Gyunggi-do, Korea
Tel: +82 - 32 - 624 - 2776~8 Fax: +82 - 32 - 624 - 2779
FACTORY

1. Caution
1.1 Guideline for Using Operation Manual
1.2 Safety Warning & Caution
2. Product Configuration
2.1 Features and Use
2.2 Structure
2.3 Components and Specification
3. Safety of the Product
3.1 Filter Function
3.2 Installation
4. Operation
4.1 Display
4.2 Instruction
4.3. Description of Key Button
4.4 Operation Procedure
5. Trouble Shooting
5.1 Maintenance
5.2 Filter Replacement
5.3 Checkpoint for failure
5.4 Service Contact
6. NOVAPRO Introduction
7. Product Warranty
CONTENTS
&DXWLRQ
This Operation Manual contains important information for preservation of product
functions and safe use of the Product. Please pay special attention to safety cautions
and warnings before using the Product. Keep this Manual near the Product for quick
reference. If you sell or lease the Product, forward this Manual to the next user to
ensure correct and safe use.
Do not place flammable or explosive
material near the Product.
It may cause fire.
Avoid hot / humid area and install the Product
in a well-ventilated place.
It may cause electric shock, fire, failure or deformation.
The Product is very heavy; it should be moved
by two or more people.
It may cause injury.
Avoid combustible area for safety.
It may cause fire.
Do not tumble the Product during connection of other equipment.
It may cause injury or damage to the Product.
Be sure to plug into wall outlet.
It may cause failure or electric shock by a short circuit.
Do not simultaneously use many devices plugged in a multiple socket.
It may cause fire by overheating in the socket.
*XLGHOLQHIRU8VLQJ2SHUDWLRQ0DQXDO
6DIHW\:DUQLQJ&DXWLRQ
03~04
05~07
07~08
09~10
11~12
14
15
CRYSTE PURIFUME_DUCTLESS
Ductless Fume Hood

PURIFUME_DUCTLESS 04 05
Be sure the rated voltage is compatible with the Product.
It may cause failure by lower power supply and fire by a short circuit.
Do not touch power plugs with wet hands.
It may cause electric shock.
Do not disassemble or alter the Product without authorization.
It may cause damage to the Product, malfunction, fire or electric shock.
Do not install the Product susceptible to high changes in voltage.
It may cause fire.
Do not apply impact to the Product.
It may damage the internal glass.
Do not place excessive amount of apparatus inside the Product.
It may impede air circulation and raise the temperature.
Do not unplug the Product during operation.
It may cause electric shock or failure.
Keep the Product away from walls (approx. 30cm) to ensure good ventilation.
Do not install the Product at places of poor ventilation or on a
carpet or sitting cushion.
PURIFUME_DUCTLESS is designed for purifying hazardous gases with specified filters
and re-circulating filtered air into laboratory. It is suitable for where duct system cannot
be installed, where movable fume hood is preferred, and where air loss should be
minimized to reduce energy consumption.
3URGXFW&RQILJXUDWLRQ
)HDWXUHVDQG8VH
1) Cartridge type filter can be easily replaced.
2) It is a movable fume hood without installing duct system.
3) Corrosion-resistant PMMA acryl walls give a wide viewing angle.
4) Air velocity in the chamber can be monitored in real time by Anemometer.
5) Long last LED Lamp is equipped.
6) There are utility holes for sockets of electrical power, water, and gas supply.
7) User can estimate time to replace the filter by observing Filter Check Cartridge.
8) Only the upper body can be used on a table without the base stand.
9) According to handled chemicals, various materials of working table are adoptable.
10) Water Valve / Gas Valve / Cup Sink (option)
6WUXFWXUH
Do not open and close the door too often during operation.
It will invite the external air in and change the internal
temperature of the Product.
Z
Max. 3 layered filter
Analog air velocity
monitor
Filter check cartridge
HEPA filter (option)
Carbon filter
Pre filter
Hybrid filter
Acid filter (option)
NH filter (option)
Easy to access and
check
Cup sink (option)
For water demand
in the chamber
Leak-tight sump
Utility holes for sockets of
power supply, gas, etc.
Prevents reagent
leakage
Leveling casters
Pass through
ports
Gas valve (option)
Door fixer
Low noise blower
Worktable surface materials
Ceramite (standard)
Phenolic laminate (option)
Ceramite Phenolic laminate
Filter life time check

PURIFUME_DUCTLESS 06 07
1) Main Body 2) Operation Manual 3) Carbon Filter set 4) Power Cord
&RPSRQHQWVDQG6SHFLILFDWLRQ
Standard Specification
Size
Pre Filter
Carbon Filter
Inlet Hole
Lamp
Noise (dB)
Bright (Lux)
Plup Type
Power Consumption
Safety
Inner(W x D x H)mm
Out(W x D x H)mm
Outside
Inside
Worktop
Filter Check Cartridge
Ceramite 30mm
Polyester fibers
Hybrid Filter
ɮ,QOHW+ROH
LED lamp
30W
<60dB
>700Lux
Controller LED lamp, Blower switch ON / OFF
Transparency acrylic 8mm ( PMMA )
Stand - H (mm) 662 (+10mm Adjustable with Leveling Caster)
ORDER NO.
900 x 625 x 790
920 x 660 x 1100
PFD900
1200 x 625 x 790
1220 x 660 x 1100
PFD1200
MODEL PURIFUME_DUCTLESS 900 PURIFUME_DUCTLESS 1200
Options
PFD-OP1
Item Order NO. Description
Applicable Model
Purifume
Ductless900 Purifume
Ductless120
0
PFD-OP2
PFD-OP3
PFD-OP4
PFD-OP5
PFD-OP6
PFD-OP7
PFD-OP8
PFD-OP9
PFD-OP10
PFD-OP11
PFD-OP12
PFD-OP13
PFD-OP14
PFD-OP15
PFD-OP16
PFD-OP17
PFD-OP18
Spare parts
PFD-SP1
Item Order NO. Description
Applicable Model
Purifume
Ductless900 Purifume
Ductless1200
PFD-SP2
PFD-SP3
PFD-SP4
PFD-SP5
PFD-SP6
PFD-SP7
PFD-SP8
PFD-SP9
PFD-SP10
Filter Check Cartridge Carbon Filter Gas valve
Epoxy powder coated Steel plate
Filter life time check
AC 220~230V, 50/60Hz, 1Phase
Fuse installed Noise Filter / Filter life time check
)LOWHU)XQFWLRQ
6DIHW\RIWKH3URGXFW
Step One
Step Two
Step Three
Filter Structure
HEPA filter
0.3㎛particles removal 99.993%
3
Pre filter
Pre filter
Primarily filters intake air, so that it is helpful to
lengthen other filter’s lifespan.
Carbon filter
HEPA filter
Carbon filter
Hazardous gases, foul air (acid and alkali)
and VOCs removal
1)Standard: Hybrid type (Acid + NH + VOCs)
2)Option: Acid type (Acid + VOCs)
3)Option: NH type (NH + VOCs)
3
3
Acid Filter Set -900
NH Filter Set -900
Acid Filter Set -1200
NH Filter Set -1200
HEPA Filter -900
HEPA Filter -1200
Without Stand
SUS 304 Work Top-900
SUS 316 Work Top-900
Phenol Laminate Work Top-900
SUS 304 Work Top-1200
SUS 316 Work Top-1200
Phenol Laminate Work Top-1200
CUP Sink
Square Sink
Gas Valve & Cock
Water Valve & Cock
Additional Inlet Hole
3
3
Replace to Acid Filter (Acid +VOCs)
Replace to Acid Filter (Acid +VOCs)
Replace to NH Filter(NH +VOCs)
Replace to NH Filter(NH +VOCs)
Add HEPA Filter
Add HEPA Filter
When customer needs only top part
Apply SUS 304 Material to Work top
Apply SUS 316 Material to Work top
Apply SUS 304 Material to Work top
Apply SUS 316 Material to Work top
Apply Phenol Laminate Material to Work top
Apply Phenol Laminate Material to Work top
Add Cup sink to Work Top (L190*W110*H170mm)
Add Square sink to Work Top (L540*W335*H240mm)
When customer wants to use Gas inside a fumehood
When customer wants to use Water inside a fumehood
When customer wants to have more inlet hole
3
33
3
Hybrid Filter Set-900
Acid Filter Set-900
NH Filter Set-900
Hybrid Filter Set-1200
Acid Filter Set-1200
NH Filter Set-1200
Cup Sink & Trap(PP)
Square Sink & Trap(PP)
Gas Valve & Cock
Water Valve & Cock
Filter Check+Pre Filter+Hybrid Filter
Filter Check+Pre Filter+Acid Filter
Filter Check+Pre Filter+NH Filter
Filter Check+Pre Filter+Hybrid Filter
Filter Check+Pre Filter+Acid Filter
Filter Check+Pre Filter+NH Filter
Cup Sink Set (PP)
Square Sink Set (PP)
Gas Valve & Cock
Water Valve & Cock
3
3
3
3

PURIFUME_DUCTLESS 08 09
2SHUDWLRQ
GolwhGmGOGvGP
Certified by KIMM.
Certificate No.: KIMM -14 -1112.
NSF49/EN 12469 standard requires
filter efficiency at
99.99% at 0.3༁
Filter frame
Filtration sheet
Aluminum
separator
Disordered filter strain distribution
,QVWDOODWLRQ
Please observe the safety instructions for proper use.
The following information is related to safety during use of the Product,
which requires your special attention.
1) Install the chamber on a level ground. An adjusting device is installed to prevent
the chamber from moving during use.(If the Product is not leveled,an accident may
occur during mixing.)
2) Install the Product at sufficient space to ensure good ventilation.
- Install away from heat, moisture, dust, vibration.
- Install under the shade away from direct sunlight.
3) The Product is heavy.
(It requires more than two people to move.)
4) Insert the power plug on the consent of correct power rate.
- The Product works with 220VAC, 50/60Hz.
- Do not place a device that uses heavy current near the Product as it may affect the Product.
- Remove the power plug from the consent when the Product is not in use for a long period of time.
- Take care that the power cord is not damaged,twisted or exposed from the sheath as it may
cause electric shock or fire.
5) Do keep a safe distance away from the front door of hood when in use.
6) Do not put your head into the chamber when it is contaminated by treating hazardous chemicals.
7) Do not use the device in purpose of storing, neither place flammable or explosive material inside.
8) Make sure to close the pass-through ports when the device is not in use.
'LVSOD\
,QVWUXFWLRQ
'JMUFS
UFTU
IPMF
"JS
7FMPDJUZ
.POJUPS
-&%
-BNQ
CVUUPO
0/
0''
CVUUPO
'JMUFS
$IFDL
$BSUSJEHF
Filter Maintenance
Filter Check Catridge
Allows user to expect filter
replacement time
Glass tube structured for
protecting from humidity.
Acid reaction NH reaction
Orange Pink Red Orange Green Blue-green
Normal Contaminated Normal Contaminated
3
Power check
Press ON button to operate hood
Check the particle level to know filter status through the hole
Press LED Lamp button to light on
Check the filter through Filter Check Cartridge
Filter Replacement System
Convenient filter replacement :
Easy to replace very quickly.
The proper filters can be chosen according to
application(or chemical properties),
which enables to lengthen the life span of filters.

PURIFUME_DUCTLESS 10 11
7URXEOH6KRRWLQJ
1) Clean with neutral detergent and remove water after washing.
2) Do not open and close the door too often.
- It may affect the Product performance.
3) If the Product is not in use for a while, close the pass-through ports completely and
wrap around the whole body with vinyl.
4) Do not operate the Product while explosive or inflammable chemical placed inside
the Product.
6) To Clean inside the Product
- Do not use chemical (such as benzene, thinner) but neutral detergent to clean the Product.
1) Disconnect the Power Cord from the body.
2) Unscrew tow bolts and open the cover forward.
3) Turn Buckle and pull out the filter.
4) Take away an old filter and install a new filter.
The filter is not reusable, so it must be replaced regularly after used.
Filter’s lifespan depends on chemical type / density and operation time.
0DLQWHQDQFH
)LOWHU5HSODFHPHQW
'HVFULSWLRQRI.H\%XWWRQ
2SHUDWLRQ3URFHGXUH
3) Air Velocity Monitor
1) ON/OFF Button
Flow Dynamics
Plug on the power cord and
press the button to operate hood.
2) LED Lamp Button
Press the button to light on.
Analog Air Velocity Monitor allows
users to easily monitor current air
velocity. (Normal range: 0.3 ~ 0.7 m/s)
Flow Dynamics
Room Air
Fume Air
Filtered Air
Installation of the product
Put in the power cord
Turn on the power switch
Check the filter check cartridge
Press LAMP botton to light on
Press ON botton to operate hood
Power check
Check if the filter is capable
]Gt
XYGo
_Go
]Go
[Go
XWGt XYGt X_Gt
)&1"'JMUFS
$BSCPO'JMUFS
1SF'JMUFS
5VSO#VDLMF
4) Replacement Check Table

PURIFUME_DUCTLESS 12 13
2SHUDWLRQDO'LDJUDP
Problems Description and Corrective Actions
The Product does
not work.
- Check if the power plug has been removed from the power consent.
- Check if the power switch has been lowered.
- Check if there is power failure.
- Check if the fuse in the rear consent socket has been broken.
The hood does
not work.
- Check if the On/Off Button turns on.
- Check if the power cord is plugged on the consent of
correct power rate.
The power is properly
supplied but the Product
does not work.
There is smoke coming
from the upper part of
the incubator.
Controller malfunction
- Press the START/STOP button on the Controller to supply power.
- Use the Power Switch to turn power off and contact Service team.
- Check if there is a device using momentary high current
around the Product.
Symptoms during operation and phenomena caused by misuse or user mistake are given
for your reference. Please check the following before contacting the Service Center for A/S
for quick and accurate diagnosis of the problem.
&KHFNSRLQWIRUIDLOXUH
1) Defects under normal operation are warranted for one year from the date of purchase.
When you request a warranty service, please inform the followings to NOVAPRO.
Area and details of the defect (As detailed as possible)
Model name
Date of purchase
The returned Product to us for repair on a freight prepaid basis.
2) The following defects are charged even if warranty period has not expired.
Any defect due to operator’s mistake including unauthorized repair of alteration.
Any defect from transportation or mishandling of the Product.
Any defect due to natural disaster including fire,flooding or power surge.
Any defect from the violation of the operation manual.
3) Please contact customer service of the main or branch office of NOVAPRO.
6HUYLFH&RQWDFW
ۋ٣ࢁ֟ࢢėşԕŒࠄş
Lamp Switch
Main & SMPS
Limit Switch
Blower Switch
Option
LED Switch Blower
IEC Inlet Filter Power Switch

PURIFUME_DUCTLESS 14 15
SERIAL NO
TEL
352'8&7 :$55$17<
1. (SELLER) Warrants to the original purchaser only against failure due to
manufacturing defects for the period specified herein.
2.The following conditions are excluded from this warranty.
Any repair will be charged even within period of warranty.
-Deterioration or damage caused by carelessness of users or arbitrary repair /
alteration.
-Breakdown caused by user’s failure to comply with user guide-spare parts
-Damage caused by act of god (Fire, Seawater, Flood, Etc.)
-When users requested reinstallation or moving of product.
3. Be sure to present this product warranty when claiming services.
4.This product warranty was prepared per compensation criteria for
consumers’ damages and cannot be re-issued. Please keep this cautiously.
Product Name Warranty period
One year from purchase
Model
Purchased on
Customer’s Address
Customer’s Name
YR MON DAY
Before you request service:
1. Before submitting claims, please check for the operation method
in the user guide and checklist before a/s request.
2. If problem continues despite check of user guide,
stop operating and unplug the product, and contact our call center.
Tel: +82 - 2 - 338 - 0059 Fax: +82 - 2 - 338 - 0079
801, ACE hightech City B/D 2 Dong, 775, Gyeongin-ro,Yeongdeungpo-Gu, Seoul, KOREA
Manufacturer and Sales office
NOVAPRO CO.,LTD. www.cryste.co.kr
129$352,QWURGXFWLRQ
:RUOG1HZ3LRQHHULQ%LRPHGLFDO/DERUDWRU\(TXLSPHQW
ZLWK%HWWHU4XDOLW\DQG+LJKHU9DOXH
NOVAPRO Co.,Ltd is one of the leading companies of laboratory and biomedical
technology equipment.
Constantly changing market developments and individual customer requirements
are the biggest challenges for us currently.
To achieve these goals, NOVAPRO has built our own R&D center so as to improve
the functions & features of products continuously. Add to this competitiveness,
all of manufacturing experts, technicians and sales managers collaborate closely
in making customers satisfied.
CRYSTE, of NOVAPRO represents the quality of our products as implementing
IQ, OQ, PQ, and as acquiring global certifications such as CE, ISO 9001.
Based on thorough plan for "high quality" like above, we have increasingly been
developing new products and have invested to the state of the art technology.
Now we are facing another important phase in our company history and preparing
a powerful leap for the future with recent development of centrifuge lines.
Our reliable and strong centrifuge lines are applicable to use in laboratory
and medical field,also.We truly believe that the centrifuges can make valuable
and impact contributions in your laboratories.
CRYSTE will help customers to have what they need in getting better work results.
We believe it is the only shortcut in building Win-Win relationship with customer
permanently.
We, CRYSTE,strongly promise we will have responsibility, passion and conviction
same as when we first began.
CRYSTE PURIFUME_DUCTLESS
Ductless Fume Hood
PURIFUME_DUCTLESS 900 / 1200
Table of contents
Popular Laboratory Equipment manuals by other brands

Sartorius
Sartorius Maxicaps MR Virosart HF Instructions for use

Thermo Scientific
Thermo Scientific Pierce G2 user manual

Keysight
Keysight 11636C Operating and service manual

OCULUS
OCULUS Mesotest II instruction manual

Thermo Scientific
Thermo Scientific SSRZ Instruction Notice

Thermo Scientific
Thermo Scientific SmartView SV100A user guide

tbs electronics
tbs electronics ATP1-120 instruction manual

Waters
Waters ACQUITY UPLC I-Class IVD System guide

Micromeritics
Micromeritics GEMINI VII Operator's manual

Renfert
Renfert Easyclean TEC Translation of the original manual

Atlas
Atlas SUNTEST CPS+ operating manual

SCHOTT
SCHOTT ColdVision Light Source Programming guide