Surge Protection
Tester
SPT-02
Digital MultifunctionTester
Insulation Resistance
Continuity
Voltmeter (AC & DC)
MOV Tester
Gas Discharge Tube Tester
Diode Tester
!
CAUTION - RISK OF ELECTRIC SHOCK
CAUTION - READ THE MANUAL BEFORE OPERATION
CAUTION - RISK OF ELECTRIC SHOCK
Safety Information
The SPT-02 has been designed with safety in mind but does not guard against misuse.
Exercise caution when connecting the leads to an external circuit.Never touch exposed
conductors. Never use the tester during a lightning storm. Always wear appropriate
protective clothing such as rubber gloves and shoes.
During Insulation,Voltage Switching and Limiting tests, high voltages are emitted from
the device. Never touch the conductors during these tests. For added protection use
the alligator clips provided to ensure the unit is properly connected.
Always disconnect the tester when checking the fuse or batteries. Before use, check
the condition of the test leads and internal fuses. Only use 20mm 250V 500mA fuses.
For accurate results this unit should be calibrated annually.
Operation
To start up the SPT-02 press the ON key. The unit will perform a battery test upon
start up and inform the user of the current battery voltage.To power down the unit
press the OFF key.
Voltmeter
The voltmeter is selected by pressing the V key on the SPT-02. The voltmeter is an
Automatic AC/DC meter with a DC range of 950V and a AC range of 750V.
Smart Hold
The smart hold feature is enabled by pressing the Vkey when the voltmeter is enabled.
The smart hold feature will hold the last value present at the leads while the unit is
disconnected.This allows the operator to concentrate on the leads during inspection.
250V, 500V, 1kV Insulation Resistance Tests
The insulated resistance tests are enabled by pressing the respective 250V, 500V or
1kV keys.The Insulation resistance tests require the circuit to be voltage free. Once
the meter is connected to the circuit press the TEST key to begin the resistance
test. The insulation resistance (IR) results are displayed on the LCD. The Dielectric
Absorption Ratio (DAR) is the ratio of IR at 1 minute divided by the IR at 30 seconds.
The Polarisation Index (PI) is the ratio of IR at 10 minutes divided by the IR at 1 minute.
For safety the unit displays a bar graph to indicate when the unit has been discharged.
To stop the test, press the TEST key again.
Continuity Tests
The continuity tests are enabled by pressing the respective Ωor kΩ keys.The range
of the Ω test is between 0.01Ω and 2kΩ and the range of the kΩ is between 1Ω and
400kΩ. To measure the continuity simply connect the leads to the circuit.
Auto Null
To re-null the device’s leads and fuse for continuity testing connect the leads together
and press the Auto Null key.The result of this is stored in non-volatile memory and
therefore only needs to be performed when the leads or the fuses are changed.
Buzzer
To enable the buzzer function, press the Buzzer key. In this mode the unit will produce
an audible tone when the resistance between the leads is less than 3 ohms.This function
is helpful for circuit tracing.
Diode Test
The diode test function is enabled by pressing the Diode key.This test injects a current
of about 1mA into the circuit.The forward voltage is displayed on the LCD.
Voltage Limiting Test
The voltage limiting test function is enabled by pressing the MOV key. This test
measures the rating of voltage limiting devices such as Metal OxideVaractors or Silicon
Avalanche Diodes at a current of 1mA and a voltage up to 1020V.
To test the device, remove it from its circuit and place the leads across the mode of
protection for testing. Press the TEST key to begin the test.The unit will increase the
voltage until the leakage current of the device reaches 1mA.The 1mA rating and the
maximum AC and DC operating voltage will be displayed on the LCD.
Note: Measurements of SPDs with intact display hardware will be inaccurate due to the current required
to drive the hardware.
Voltage Switching Test
The voltage switching test function is enabled by pressing the GAZ key. This test
measures the rating of voltage switching devices such as Gas Discharge Tubes and
Thyristor Surge Protection Devices at a current of 1mA and a voltage up to 1020V.
To test the device, remove it from its circuit and place the leads across the mode of
protection for testing. Press the TEST key to begin the test.The unit will increase the
voltage until the trigger voltage is reached.The trigger voltage and the maximum AC
and DC operating voltage will be displayed on the LCD.
MOV Test
Measuring Range 5 -- 1020 V DC
Voltage Accuracy ± 3%
GDT Test
Measuring Range 5 -- 1020 V DC
Voltage Accuracy ± 3%
Voltmeter
DC Voltage 0 -- 950 V
AC Voltage 0 -- 700V
Resolution 1V
Voltage Accuracy ± 3%
Insulation Resistance
Test voltage 250, 500, 1000V
Measuring Ranges 250V: 0.2MΩ -- 2GΩ
500V: 0.2MΩ -- 4GΩ
1000V: 0.2MΩ -- 8GΩ
Accuracy 0.2MΩ - 4GΩ : ± 3%
4GΩ -- 8GΩ : ± 5%
Short Circuit Current 1.2mA
Polarisation Index (PI) on all ranges
Dialectric Absorbtion Ratio (DAR)
on all ranges
KΩ Test
Ranges 1 -- 400kΩ
Short Circuit Test Current ≥ 1.3mA
Continuity
Ranges 0.01 -- 100Ω
100 -- 300Ω
300 -- 1999Ω
Accuracy 0.01 -- 100Ω : ± 1.0%
100 -- 300Ω : ± 1.5%
300 -- 1999Ω : ± 2.0%
Auto Null up to 5Ω
Buzzer up to 3Ω
Diode Test
Test Voltage 5V DC
Max Test Current 1.5 mA
Resolution 0.1V
Measurement Voltage 0 -- 4.5V
Accuracy ± 3%
General
Fuse 500mA 250V Fast Blow
Display 2 Line x 16 Character LCD
Dimensions 205 (L) x 90 (W) x 55 (D)
Weight 1.5kG
Power Source 1.5V AA x 6
Storage Temperature -20˚C to 70˚C
Accessories Test Leads
Fuse (0.5A 250V)
Heavy Duty Case
Instruction Manual
Batteries
Global Solutions
in Lightning and Surge Protection
© 2012 Powercom Consultants Pty Ltd
Limited Warranty
We guarantee that this product is free form defective materials or production issues for 12 months and
agree to repair or replace a product which is found defective during normal use. Consult this manual for
instructions for correct use of this device.
This warranty does not apply to products that have been repaired or altered by unauthorised persons.
The purchaser agrees to assume all liability for any damages or injury which may result from use or misuse
of this device.
Product specications may change without notice
Distributed by: PowerCom Solutions Pty Ltd

Popular Test Equipment manuals by other brands

Viavi T-BERD MTS 5800 Quick Card

Viavi

Viavi T-BERD MTS 5800 Quick Card

Integrity Shark Base Instruction

Integrity

Integrity Shark Base Instruction

BC Biomedical ULT-2000 series user manual

BC Biomedical

BC Biomedical ULT-2000 series user manual

WIKA CalibratorUnit CPU6000 Series operating instructions

WIKA

WIKA CalibratorUnit CPU6000 Series operating instructions

SCS TB-9031 user guide

SCS

SCS TB-9031 user guide

Metra Electronics MTLTB02 user manual

Metra Electronics

Metra Electronics MTLTB02 user manual

Dräger Alcotest 9510 Standard IR Instructions for use

Dräger

Dräger Alcotest 9510 Standard IR Instructions for use

National Instruments PXIe-5672 Getting started guide

National Instruments

National Instruments PXIe-5672 Getting started guide

AGI EZTest Hazmon manual

AGI

AGI EZTest Hazmon manual

NEO TOOLS 99-043 Original instruction manual

NEO TOOLS

NEO TOOLS 99-043 Original instruction manual

Dantel 05615 Installation & operation manual

Dantel

Dantel 05615 Installation & operation manual

Hanwei Alco Smart AT6000 Operation manual

Hanwei

Hanwei Alco Smart AT6000 Operation manual

Opus Triplog AlcoTrue user manual

Opus

Opus Triplog AlcoTrue user manual

Ripley Miller DLS355 user guide

Ripley

Ripley Miller DLS355 user guide

Fluke CableIQ user manual

Fluke

Fluke CableIQ user manual

Factair F6001 operating manual

Factair

Factair F6001 operating manual

Viavi SmartOTDR Mainframe user manual

Viavi

Viavi SmartOTDR Mainframe user manual

ELMED ISOTEST 4S Operation manual

ELMED

ELMED ISOTEST 4S Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.