Novatek Novair F700 c/w HEPA 110v User manual


© Copyright 2015 by NOVATEK Corporation
All rights reserved printed in the United States of America. No part of this manual may be used or reproduced in any
form or by any means, stored in data base or retrieval system, without prior written permission from NOVATEK
Corporation.
Making copies of this manual for any purpose other than your own personal use is a violation of the United States
copyright laws.
March 1, 2016 issue 1.0
Specifications subject to changes without notice!
If you have any questions, please contact us:
NOVATEK CORORATION
700 Schell Lane
Phoenixville, PA 19460
USA
www.novatekco.com
Toll Free 866 563-7800
Telephone: +1 610 363-7800
Fax +1 610 935-1945
Email: Sales@Novatekco.com
Refer All Communications to the Nearest
Novatek Corporation Office or Distributor.
Printed in U.S.A.

OPERATION AND MAINTENANCE MANUAL FOR
F0700 & F0705
FOR PROFESSIONAL USE ONLY
IMPORTANT SAFETY INFORMATION ENCLOSED.
READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THIS PRODUCT.
IT IS YOUR RESPONSIBILITY TO MAKE THIS SAFETY INFORMATION AVAILABLE TO
OTHERS THAT WILL OPERATE THIS PRODUCT.
FAILURE TO OBSERVE THE FOLLOWING WARNING COULD RESULT IN INJURY.
PLACING MACHINE IN SERVICE
Always install, operate, inspect and maintain this
product in accordance with all applicable standards and
regulations (local, state, country, federal, etc.).
Always use proper gauge cord with correct connections.
Be sure all cords are securely connected to the
recessed male plug.
Ensure an accessible emergency shutoff when your
machine is connected to power. Make others aware of
its location.
Do not use damaged, frayed, or deteriorated electrical
cords or connections.
Do not leave machines in operation unattended for over
4 hours without inspection.
Keep all electrical connections clear of water or other
liquid hazards.
Always turn off and unplug your machine before
performing any maintenance.
Do not operate the machine while flammable or volatile
liquids such as gasoline, diesel or jet fuel are present.
Failure to do so can result in explosion.
Keep work area clean, uncluttered and illuminated.
Do not remove any labels. Replace any damaged labels.
USING THE MACHINE
Always wear protection when operating or
performing maintenance.
Always use Personal Protective Equipment
appropriate to the work being performed. This may
include dust mask or other breathing apparatus,
safety glasses, ear plugs, gloves, apron, safety
shoes, hard hat and other equipment,
If applicable, prevent exposure and breathing of
harmful dust and particles:
Some dust created by power sanding,
sawing, and grinding, drilling, and other
construction activities contains chemicals
known to cause cancer, birth defects or
other reproductive harm. Some examples of
these chemicals are:
- Lead from lead based paints,
- Crystalline silica from bricks and
cement and other masonry
products, and
- Arsenic and chromium from
chemically treated lumber
Your risk from these exposures varies,
depending on how often you do this type of
work.
Keep others a safe distance from your work area, or
ensure they use appropriate Personal Protective
Equipment.
This machine is not designed for working in
explosive environments, including those caused by
fumes and dust, or near flammable materials.
This machine is not insulated against electric
shock.
Keep hands, loose clothing, long hair and jewelry
away from the machines blower assembly and “Air
Intake.”
To avoid accidental starting –ensure machine in
“off” position before connecting to power.
Do not carry or drag the machine by the cord.
Do not operate or maintain the machine under the
influence of medication, drugs, or alcohol.
Never us a damaged or malfunctioning machines,
Do not modify the machine, safety devices, or
accessories.
Do not use this machine for purposed other than
those recommended.
Only use accessories recommended by Novatek
Corp.
Whenever applicable, wear safety shoes, hard hat,
safety goggles, gloves, dust mask and any other
appropriate protective clothing in the work area.
Do no indulge in horseplay. Distraction can cause
accidents.
Use only proper cleaning solvents to clean parts.
Use only cleaning solvents which meet current
safety and health standards. Use cleaning solvents
in a well ventilated area.
Do clean machine any parts with diesel fuel or any
other petroleum distillates.
Do not operate the tool with broken or damaged
parts.
This tool is not designed for working in explosive
atmospheres.
NOTICE
WARNING

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
4
TABLE OF CONTENTS
SECTION I
Introduction ............................................................................................................................... 5
SECTION II
General Description .................................................................................................................. 5
SECTION III
Routine Maintenance................................................................................................................ 5
Control Descriptions................................................................................................................. 6
SECTION IV
Prior To Use............................................................................................................................... 7
Operation ................................................................................................................................... 7
SECTION V
Replacement Of Filters ............................................................................................................. 7
SECTION VI
Wiring Diagrams..................................................................................................................... 8,9
SECTION VII
Schematic……………………………………………………………………………………………...…10
SECTION VIII
Safety........................................................................................................................................ 11
Troubleshooting...................................................................................................................... 11
Novatek Corporation Limited Warranty................................................................................ 12

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
5
SECTION I
INTRODUCTION
This operation and maintenance manual is furnished with each NOVAIR 700. It outlines the general use and
maintenance requirements for efficient and safe operation.
READ ALL INSTRUCTIONS AND DATA IN THIS OPERATION AND MAINTENANCE MANUAL PRIOR
TO OPERATION OF THIS EQUIPMENT.
These instructions are for your protection and convenience. Please read them carefully. Failure to follow
these precautions could result in injury or death. Whenever using electric powered equipment, basic safety
precautions should be followed.
If after reading this manual you still have questions, contact a NOVATEK authorized distributor or
NOVATEK directly by dialing 1-866-563-7800.
SECTION II
GENERAL DESCRIPTION
The NOVAIR 700 is a portable, electrically powered Air Filtration machine, designed and manufactured by
Novatek Corp. The machines function is to filter air and remove suspended airborne particulates.
This unit has a three stage filtering system. The Pre-Filter (two-ply ring) stage captures the bulk of the dust
and debris. The second Pleated Filter stage captures any dust and dirt able to penetrate the Pre-Filter. The
final stage is the 99.99% - 0.3 micron HEPA Filter utilized in areas where an extremely high level of filtration
is desired.
The NOVAIR 700 requires a 115V - 3 Amp / 230v-2 Amp single phase power source.
WARNING Do not use circuits exceeding specified voltage. Higher voltage will damage controls and
could cause shock or fire hazard.
SECTION III
ROUTINE MAINTENANCE
Inspect the unit for any loose or damaged parts prior to use.
CAUTION: Be sure power supply is in the OFF position prior to inspection!
A. Clean the surfaces of the unit to remove accumulated dust or dirt. Do not use petroleum distillates,
solvents, or thinners as cleaning agents. Remove any accumulated dust and dirt from control panel.
B. Periodic checks should be made of the panel’s Controls to insure proper operation.
C. Filters should be checked hourly/daily and replaced if needed. This will help ensure proper air flow and
extend motor life.
D. Inspect ALL power connection. Be sure that the recessed plug is secure to the panel. If recessed plug
is not secured, electrical shock or shortage may occur.
E. Inspect the power cord connection for breaks, scorching, melting, oxidation, or signs of wear. If cord
shows ANY of these signs, it needs to be replaced.
CAUTION: Do not tamper with or modify the blower housing, control panel, drive motor, or wiring
scheme. Tampering or modifications could result in premature wear or failure and will void factory
warranty.

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
6
CONTROL DESCRIPTIONS
1. Circuit Breaker Switch
The green circuit breaker switch is used to show power is going to Novair and protect the controls of the
machine. This adds power to the GFCI outlets to allow daisy chaining of equipment and will trip if
maximum amperage is exceeded.
2. Variable Speed Dial
The variable speed dial can be set from 200 -700cfm depending on the desired vacuum flow. The
maximum setting is shown to the left as the dial is first turned to the “ON” position.
3. Auxiliary “GFCI” protected Outlet -115v
The auxiliary GFCI outlet can be used to daisy chain “No More” the 3 units together. The maximum of
12 Amps when the unit is in the “OFF” position and 9 Amps when the unit is in the “ON” position. You
can attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet
is working properly the green light is lit on circuit breaker.
Auxiliary Outlet -230v (Not Shown)
The auxiliary 230voutlet can be used to daisy chain “No More” the 3 units together. The maximum of 6
Amps when the unit is in the “OFF” position and 4 Amps when the unit is in the “ON” position. You can
attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet is
working properly the green light is lit on circuit breaker.
CAUTION: If the GFCI trips “UN-PLUG” the unit from the power source and check for any
potential hazards (damaged power cord, moisture, too many units plugged, etc.) causing a
power surge. Once unit is evaluated plug the unit into a new power source and push the reset
button. If unit operates as normal: continue use, if unit trips again contact Novatek at 866-563-
7800.
4. Filter change indicator
The indicator light will alert the operator when filters are loaded or when air flow is greatly decreased.
The light will come on once the pressure reaches approximately 3”of water column. Filters should be
inspected and replaced. Once filters are replaced the light will go off. If light stays on contact Novatek at
866-563-7800.
5. Power Cord
Firmly insert the female end of the power cord into a grounded power source. Visually inspect the cord
for any damage before installation into power source.
CAUTION: A loose, corroded, ill fitted or damaged cord or plug can cause injury. If cord has any
of these issues should be re-placed immediately.

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
7
SECTION IV
PRIOR TO USE
A. Wrap and inspect power cord.
B. Remove any excess dust/dirt from exterior housing and control panel.
C. Be sure the HEPA Filter and Pre-Filters are installed properly with a positive seal.
D. Insure the unit is connected to a 115 volt grounded outlet.
E. Make sure unit is safely positioned as not to impede any entrances or exits of the work area.
F. If applicable, check exhaust port connections for tight seal.
CAUTION: Insure power cord is securely attached to control panel and in good condition.
OPERATION
A. When utilized in containment, the Novair 700 should be positioned a minimum distance away from the
entrance and located towards the center of the containment.
B. When working with contaminants, insure the HEPA filter is correctly installed and sealed.
C. Install the pre-filter and pleated filters into unit.
D. Insert the female end of the power cord, into the grounded 115v outlet.
E. To begin operation, depress the green circuit breaker switch to the on position. The green light will be lit
on the breaker if working properly. This must be in the on position to use GFCI outlet.
F. Turn the variable speed dial to operate the fan from 200 -700CFM from high to low.
G. A total of three units can be connected together to create a negative pressure in different parts of the
containment area.
SECTION V
REPLACEMENT OF FILTERS
The work atmosphere will impact the frequency of filter replacements. Once the filters load and the pressure
reaches approximately 3”the visual alarm will light.
CAUTION: Always wear approved respirators and personal protective equipment during filter
replacement. Please observe all Federal, State, and Local regulations regarding the handling and
disposal of hazardous materials.
PRE-FILTER REPLACEMENT
A. Set the variable speed and circuit breaker power switches to the off position. Disconnect power supply.
B. Remove inlet panel to expose the pre and pleated filters.
C. Reach in and remove the pre-filter and dispose of pre-filter accordingly.
D. Replace the discarded pre-filter with a new pre-filter.
E. Reinsert the inlet panel.
F. Plug in power cord to 115v grounded outlet and turn the circuit breaker to the “ON” position. Turn the
variable speed controller to the “High” position. If the visual alarm light is still on the pleated filter should
be inspected.
PLEATED FILTER REPLACEMENT
A. Follow steps A-D listed above referencing Pre-Filter replacement.
B. Reach in and remove the pleated filter and dispose of pleated filter accordingly.
C. Replace the discarded pleated filter with a new unused pleated filter.
D. Reinstall the pre-filter.
E. Reinsert the inlet panel.
F. Plug in power cord to 115v grounded outlet and turn the circuit breaker to the “ON” position. Turn the
variable speed controller to the “High” position. If the visual alarm light is still on the HEPA filter should
be inspected.
HEPA FILTER
A. Follow steps A-D listed above for pre-filter replacement.
B. Locate and remove the (8) hex flange filter screws on the housing filter frame exposing the HEPA filter.
C. Firmly grasp the HEPA filter and dispose of HEPA filter accordingly.

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
8
D. Carefully Inspect the new HEPA filters gasket for cracks, gaps or defects. Any defective gaskets must
be replaced.
E. The HEPA filter has two sides. One side is has a gasket, the other does not. Insert the side with the
gasket of the HEPA filter first and press firmly against the housings internal rib.
F. Install the housing filter frame and reinstall the (8) hex flange filter screws. Tighten the screws to
properly seal and secure the HEPA filter in place.
G. Reinstall pre -filter and pleated-filter. (Reference Pre-Filter and Pleated Filter Replacement).
H. Insert the housing inlet panel.
SECTION VI
WIRING DIAGRAM -115v

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
9
WIRING DIAGRAM -230v

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
10
SECTION VII
Schematic

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
11
SECTION VIII
SAFETY
Novatek Negative Air Machines are highly efficient systems designed to reduce air borne particulates. To
insure proper operation, the following safety precautions should be strictly adhered to:
A. Do not leave machine unattended when connected to a power source. Turn OFF electric supply and
disconnect from power source when not in use and/or before servicing.
B. Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an
Authorized Repair and Service Center.
NOTE: Always replace worn or damaged components with genuine NOVATEK parts. Failure to
comply could result in equipment failure and will void warranty.
C. Remove any loose clothing and adornments prior to operation.
D. Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly.
E. Turn off power prior to any filter inspection and replacement.
F. Do not operate unit with flammable or combustible liquids or gases present.
G. Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
H. Never operate the unit if there is any possibility of contact with the blower wheel.
I. It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient
operating condition.
J. Stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100
degrees Fahrenheit. (Failure to comply will void warranty.)
TROUBLESHOOTING
A. Basic issues listed below. For any further problems not listed, call your local distributor or Novatek at
866-563-7800.
Problem
Cause
Solution
Unit will not operate
No power to unit
Variable speed controller not on
GFCI green light off (115v)
Circuit breaker green light not on
Building circuit breaker tripped
Defective power cord
Check power at outlet
Turn dial switch on
Push reset on GFCI outlet
Turn on Breaker switch
Reset panel breaker
Check power cord
connections
Fan Wheel not turning
Obstruction block fan
Variable speed controller not on
No power to Unit
Remove Obstruction
Turn dial switch on
Check power at outlet
Circuit breaker on unit or
building panel trips
Overloaded circuit on control panel
Overloaded circuit at panel box
Unplug any equipment
from GFCI
Unplug any additional
equipment from outlet
Filter change light
illuminated
Filters are full/loaded
Inlet panel restricted
Change filters; refer to
section V in manual
Check ducting; eliminate
bends

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]*
12
NOVATEK CORPORATION LIMITED WARRANTY
ELECTRICAL COMPONENTS utilized in the NOVAIR product line are warranted to be
free from defects in material and workmanship for a period of 180 DAYS from date of
purchase from Novatek. The remaining materials in the NOVAIR are warranted to be
free from defects in material and workmanship for a period of 1 YEAR from the date of
purchase from Novatek. This warranty does not extend to accessories.
This warranty applies only to UNITS purchased from the NOVATEK CORPORATION or
authorized retailers. This warranty does not apply to any UNIT which has been abused,
misused, modified or repaired by someone other than the NOVATEK CORPORATION
or its authorized repair center.
If a UNIT proves defective in materials or workmanship within one year of purchase, it
should be returned to NOVATEK CORPORATION via pre-paid transportation. The
return must be accompanied by a RETURN MERCHANDISE AUTHORIZATION
NUMBER (R.M.A. #) obtained from NOVATEK CORPORATION. The Return
authorization number must be clearly marked on the outside of the package being
returned. Any returned merchandise that does not have a return merchandise
authorization number clearly marked on the outside of the package will be refused and
returned to sender.
Warranty claims will only be considered upon proof of purchase date. NOVATEK
CORPORATION will, at its discretion, REPAIR or REPLACE DEFECTIVE PARTS.
Repairs or replacements parts are warranted as above for the remainder of the original
warranty period. The sole liability of NOVATEK CORPORATION and the user’s
exclusive remedy under this warranty is limited to the repair or replacement of the
defective product.
THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED AND NOVATEK
CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES OR ANY OTHER EXPENSES OR REPAIR OR REPLACEMENT
AS DESCRIBED ABOVE.
All warranty claims should be forwarded to:
NOVATEK CORPORATION
700 Schell Lane
Phoenixville, PA 19460
ATTENTION: CLAIM AND SERVICE DEPARTMENT
R.M.A. # ____________
CALL Toll Free at 1-866-563-7800 for your RMA number PRIOR TO SHIPPING.
Also include a brief description of the problem as well as a phone number, contact name
and return address in case NOVATEK CORPORATION service personnel has to get in
contact with you.