  9. NRG Systems SYMPHONIEPLUS 3 User manual

NRG Systems SYMPHONIEPLUS 3 User manual

Other NRG Systems Data Logger manuals

NRG Systems SymphoniePLUS User manual

NRG Systems

NRG Systems SymphoniePLUS User manual

NRG Systems SymphoniePLUS3 User manual

NRG Systems

NRG Systems SymphoniePLUS3 User manual

NRG Systems LOGR-S User manual

NRG Systems

NRG Systems LOGR-S User manual

NRG Systems SymphoniePRO User manual

NRG Systems

NRG Systems SymphoniePRO User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

MadgeTech PRTemp140 Product user guide

MadgeTech

MadgeTech PRTemp140 Product user guide

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Symphonie_Sensor_Connections_Instructions | Rev 2.0 | 23 February 2015 | support@renewableNRGsystems.com || 1
NRG Sensor Connections to Symphonie
Introduction
These instructions will assist you in connecting standard NRG sensors to a Symphonie logger and also provide
the default slope and offset for each sensor type. These default values are preloaded in the Symphonie logger
(except for iPack voltmeter) and the Symphonie Data Retriever (SDR) software. The values are included here
as a quick reference only - please see the Symphonie manual for logger channel configuration.
Connections
NRG #40
Anemometer
RH-5
Relative Humidity
Sensor
BP-20
Barometric Pressure
Sensor
Li-200SA
Pyranometer
Model 110S
Temperature
Sensor
Rain Gauge
(Novalynx)
Wind Direction Vane
Red Dot
(-) Black
White
(+) Red
NRG #200P
N
White
Logger
Grounding
Wire clamps to
Ground Rod
Ground wire lug
attaches here
Bare shield wire
Bare shield wire
Bare shield wire
White (inner)
White
Red
Black
Bare (outer)
White
Black
Red
Red
White
Black
Black
Ground
Rod
Symphonie wiring panel
Symphonie Sensor Connections
Bare shield wire
Red
Black
Red
White
Black
(+)White
(-)Black
Bare shield wire
Sensor Shield (bare) Wires
Connect to any of the
15 shield terminals
Signal
Symphonie_Sensor_Connections_Instructions | Rev 2.0 | 23 February 2015 | support@renewableNRGsystems.com || 2
Default Slope and Offsets for Symphonie
Both the Symphonie logger and SDR software come loaded with default slope and offset values for our standard
sensors. Please note that these settings are specific to Symphonie and may not be the same values used for
other data loggers. Some sensors are provided with sensor specific values that may be used in place of these
defaults.
Sensor Default Slope and Offsets for use with Symphonie
Sensor
Slope
Offset
Scaled Units
NRG #40 Anemometer
0.765
0.35
m/s
NRG #200P Wind Direction Vane
0.351
0
degrees
NRG #110S Temperature Sensor with Radiation
Shield
0.136
-86.38
C
NRG #BP20 Barometric Pressure Sensor
0.4255
650
mB
Relative Humidity Sensor
0.097
0
%RH
Li-Cor #LI-200SA Pyranometer
1.32
0
W/sqm
Rain Gauge-Tipping Bucket
0.254
0
mm
***iPack Voltmeter SCM***
0.021
0
Volts