MAINTENANCE
All machine parts should be regarded as contaminated when removed from the hazardous area and
appropriate action taken to prevent dust dispersal.
Disconnect from the power supply during cleaning, maintenance or when replacing parts.
Ensure the plug is removed from the Power socket outlet.
Maintenance must be carried out in a suitable non hazardous area with facilities for cleaning the area
after servicing, and with suitable ventilation.
Maintenance and cleaning work must always be carried out by competent authorised personnel equipped
with suitable personal protection.
If the cloth seal is found to be damaged or badly contaminated, you must replace. If only mildly
contaminated, either wipe clean or wash with a mild detergent (ensure it is dry before replacing).
plastic bag and disposed of in accordance with current regulations. Replace the items that cannot be
satisfactorily cleaned using approved manufacturer parts.
Regularly examine the supply cord for damage, such as cracking or ageing. If damage is found,
replace the cord before further use.
All parts of this vacuum are safety critical only replace with the genuine Numatic spare parts.
For user servicing, the machine must be dismantled, cleaned and serviced, as far as is
exhaust ventilation where the machine is dismantled, cleaning of the maintenance area and
suitable personal protection.
In class H machines the outside of the machine should be decontaminated by vacuum cleaning methods
and wiped clean or treated with a sealant before being taken out of the hazardous area and appropriate
action taken to prevent dust dispersal. (HSE Risk Assessment needed).
A competent person shall perform a technical inspection at least annually, consisting of, for
mechanism.
Replacing HEPA Fliters Process.
Replacing HEPA Fliters Process.
Remove the Head assembly and place in a safe area.
accordance with current regulations.
Re-assemble the machine in reverse order. (Screw torque 2.5Nm).
During this process please look carefully at all seals between mating parts and check for any damage.
If seals have been damaged, please contact the machine manufacturer to obtain an approved
replacement part.