Numatics EMERSON FlowtronicD User manual

FlowtronicD
2-Port Flow Control Valve with Digital Electronics
Installation Manual
青岛秉诚自动化设备有限公司 服务热线:4006-918-365 传真:(86-532)585-10-365

CAUTION! Dangerous operating conditions may occur when using the programming interface on the valve as the valve may possibly
not react to the analog setpoint any more.
Provide for protection against uncontrolled movement of equipment when putting the valve into operation and before making any
modifications to the valve settings.
NOTICE
The information in this manual is subject to change without notice.
In no event shall Numatics be liable for technical or editorial errors or omissions. Neither is any liability assumed for accidental or consequential
damages arising out of or in connection with the supply or use of the information contained herein.
THIS MANUAL CONTAINS INFORMATION PROTECTED BY COPYRIGHT. NO PART OF THIS DOCUMENT MAY BE PHOTOCOPIED OR REPRODUCED
IN ANY FORM OR MANNER WHATSOEVER WITHOUT PRIOR WRITTEN PERMISSION FROM NUMATICS.
ESD
This product complies with the essential requirements of the EMC Directive 89/336/EEC and its amendments. It is CE-approved. A separate Declaration
of Conformity is available on request.
A separate Declaration of Incorporation relating to the EU Directive 89/392/EEC Annex II B is available on request. Please provide ordering code and
serial numbers of products concerned.
DECLARATION OF INCORPORATION
according to Machinery Directive 89/392/EEC, Annex II B
We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other machinery and that
it must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of Council Directive 89/392/
EEC, Annex IIB.
Handling, assembly and putting into service and all settings and adjustments must be done by qualified, authorised personnel only.
This product contains electronic components sensitive to electrostatic discharge.
An electrostatic discharge generated by a person or object coming in contact
with the electrical components can damage or destroy the product.
To avoid the risk of electrostatic discharge, please observe the handling
precautions and recommendations contained in standard EN 100015-1. Do not
connect or disconnect the device while it is energised.
CAUTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC SENSITIVE DEVICES
!
1
1.1
1.2
1.3
1.4
2
3
4
5
6
6.1
6.2
7
8
9
Table of Contents
FlowtronicD
Description 3
How To Order 3
Operating Elements 4
Manual Setpoint Adjustment 4
Operating Modes 4
Electrical Connection 5
Pneumatic Connection 6
Factory Settings 6
Field-programmable Settings 6
Technical Characteristics 7
Fluid Characteristics 7
Electrical Characteristics 7
Accessories 8
Maintenance and Care 8
Dimensions and Weight 8

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
3
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
1. Description
The FlowtronicDflow controller is especially designed for applications placing extreme dynamic demands on flow
control. It consists of a fast, direct-acting 2-port proportional valve and a control unit that contains all the electronics
and sensors. The FlowtronicDoffers precise flow adjustment and quickly responds to outside influences. High
accuracy is achieved by measuring the flow with two sensors. The FlowtronicDdirectly regulates the actual rate of flow
and adjusts it quickly to changing conditions.
The use of digital control electronics and a USB interface allow the FlowtronicDto be adapted to different
applications. An auto-tune function and the Numatics FlowCom PC software provide easy start-up. Diagnosis of the
FlowtronicDis made possible over the integrated LEDs and the Numatics FlowCom PC software. The FlowtronicDis
available with or without LED display and operating buttons.
1.1 How to Order
Notes:
1) Feedback input is needed for dual loop units.
Feedback
1 = Feedback output 00 ... 10 Volt
2 = Feedback output 00 ... 20 mA
3 = Feedback output 04 ... 20 mA
4 = Feedback input 0 - 10 Volt1)
5 = Feedback input 0 - 20 mA1)
6 = Feedback input 4 - 20 mA1)
8 3 3 - 3 8 0 1 0 1 1 5 0
Version (ports), body / Display
0 = (GTap) without display*
1 = (GTap) with display*
2 = 1/2 (GTap) without display
3 = 1/2 (GTap) with display
6 = (NPT) without display*
7 = (NPT) with display*
8 = 1/2 (NPT) without display
9 = 1/2 (NPT) with display
* Port size depends on flow range (1/4 or 3/8)
Command signal
0 = 0 ... 10 Volt
1 = 0 ... 20 mA
2 = 4 ... 20 mA
Digital I/O
1 = Pressure switch output
PNP ± 5 %
Flow regulation range
10 = 0.4 - 3.5 SCFM (10 - 100 Nl/min)
(1/4 - Versions 0, 1, 6 or 7 only)
20 = 0.4 - 7.1 SCFM (10 - 200 Nl/min)
(1/4 - Versions 0, 1, 6 or 7 only)
30 = 0.4 - 10.6 SCFM (12 - 300 Nl/min)
(1/4 - Versions 0, 1, 6 or 7 only)
50 = 0.7 - 17.7 SCFM (20 - 500 Nl/min)
(1/4 - Versions 0, 1, 6 or 7 only)
60 = 0.8 - 21.2 SCFM (22 - 600 Nl/min)
(1/4 - Versions 0, 1, 6 or 7 only)
99 = 1.8 - 35.3 SCFM (50 - 1000 Nl/min)
(3/8 - Versions 0, 1, 6 or 7 only)
20 = 3.5 - 70.6 SCFM (100 - 2000 Nl/min)
(1/2 - Versions 2,3,8 or 9 only)
Options
A00 = Dual loop control

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
4
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
1.2 Operating Elements
1.3 Manual Setpoint Adjustment (Hand)
1.4 Operating Modes
1 Proportional solenoid cover
2 Power supply, M12 connector
3 USB port, M12B connector
4 Operator buttons
5 3-digit display of flow
6.1 Green LED
OFF: Setpoint ≠feedback
ON: Setpoint = feedback
Flashing: Overtemperature
6.2 Yellow LED
OFF: Normal
ON: Manual operation
Flashing: AUTOSAFE enabled
6.3 Red LED
OFF: Normal
ON: Low voltage
Flashing: Overvoltage
3
2
6.3
5
4
1
6.1 6.2
After an interruption in the power supply, press both arrow buttons located beneath the display during power up to
switch to the manual mode. The operating mode is indicated by the letters “H n d” in the display.
The "H n d" display disappears when the arrow buttons are released.
Press the left arrow button or DOWN arrow to reduce the flow, press the right arrow button or UP arrow to increase
the flow. The yellow LED is on permanently during manual mode.
Exit this operating mode by pressing both arrow buttons simultaneously or by turning off the power supply for a
short time.
Shut-off:
If the command signal falls below 0.5 %, the control valve is switched off and the flow is interrupted.
Overtemperature:
If the temperature of the internal control electronics exceeds 100°C the green LED starts to flash.
Undervoltage / overvoltage:
If the supply voltage is less than 19 V or more than 30 V, the control valve is switched off and the valve is locked. The
red LED lights up constantly to indicate undervoltage or flashes to indicate overvoltage.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
5
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
2. Electrical Connection
1) The valve must only be supplied with 24V DC at a tolerance of +15%/-10% and a max. ripple of 10% (no supply via
diode bridge). Overvoltage or a ripple rate exceeding these tolerances can damage the electronics.
2) The max. current at the digital output is 200 mA/4.8W (PNP output). The output is protected against short circuit and
overload.
3) If a relay (inductive load) is connected to the digital output, a freewheel diode or a varistor must be used.
4) A shielded cable must be used for protection against interference and EMC.
5) The valve body must be grounded with the earthing terminal PE (dia. M4)
5-pin M12 female connector
(view on soldered side)
250 Ohm at
current setpoint
Valve
M12 connector
+24V supply voltage
Supply voltage GND
Setpoint GND
(only for 6-wire cable)
Setpoint
0-10V
(or 0-20 / 4-20mA)
Feedback
0-10V
(or 0-20 / 4-20mA)
Control
Analog output:
Only at current output:
max. 500 ohm
Digital output: PNP when setpoint is reached
(setpoint=feedback)
Inductive
load
M4 connection on valve body
Connector housing
Shield
=200mA max./4.8W
Connector Pin Out
2
14
3
5
PIN Description
1 +24 VDC Supply
2 Command Signal
3 +0 VDC Common (Supply)
+0 VDC Common (Command Signal)*
4 Analog output (feedback)
5 Digital output (pressure switch)
Body EMC shield
*A 6-wire cable with separate common for the command signal is used for cable
lengths over 2 m to minimize the voltage drop for the command signal.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
6
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
3. Pneumatic Connection
The air flow is from port 1 in the direction of the arrow.
• Setpoint offset: 0 l/min flow rate at a command signal of 0 Volt or 0/4 mA.
• Span: Max. specified flow at a command signal of 10 V / 20 mA.
• Minimum hysteresis.
• The control parameters, setpoint offset, setpoint span and window size of the digital output are factory-
programmed.
Parameter set: factory settings
Setpoint offset: 0%
Setpoint span: 100%
Setpoint ramp: no ramp
Shut-off: ON; the flow rate is 0 at a command signal below 0.5%
Controller structure: PID
Proportional gain: 0.1
Integration time: 0.2 sec
Derivation time: 0 msec
Window size: 5 %
Display
The actual flow rate is displayed in Nl/min during normal operation.
Hnd indicates that the Manual mode has been selected.
Push Buttons
To enter the Manual mode, press and hold both pushbuttons simultaneously and power off and power up again.
"Hnd" appears in the display.
Use the UP button to increase the flow rate and the DOWN button to decrease it. The actual flow rate is displayed.
Quick presses on the buttons allow you to make slight changes in the flow rate.
Inch screw connections (pipe threads) must be used.
Each screw connections must be lined with a fitting synthetic sealing disc.
Do not use Teflon sealing tape or hemp as they may get inside the valve and damage it.
The diameter of the pneumatic lines must be adjusted to the nominal diameter of the valve. The diameter of outlet line
(2) must be larger or equal to that of inlet line (1).
The supply pressure must not exceed 8 bar (116 psi).
OutletPressure supply
4. Factory Settings
5. Field-Programmable Settings

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
7
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
5. Field-Programmable Settings (Cont'd)
Push Buttons (Cont'd)
Longer presses allow you to make larger changes in the flow rate.
Press both pushbuttons simultaneously to exit the "Manual mode" and return to the "Regular mode". Pressing the UP
or DOWN button in "Regular mode" causes the display to blink and show the setpoint in %. Press the UP or DOWN
button again to display the actual flow rate.
Autotune
AUTOTUNE determines the forward current the proportional valve needs to open. This control parameter, called for-
ward offset, is permanently stored.
AUTOTUNE can be activated in the three following ways:
1. Press and hold the AUTOTUNE button, switch the supply voltage off and on again, and release the AUTOTUNE but-
ton.
2. Over the Numatics FlowCom operating software.
3. If the appropriate option has been selected over the operating software, AUTOTUNE can be activated over the digital
input (M12, Pin 5).
After having determined the forward offset, the device will automatically go into Regular mode.
Construction Installation
Directly operated valve Assembly position: any (solenoid upright preferred)
Body: Aluminium
Internal parts: Aluminum, brass, stainless steel
Seals: NBR
6.1 Fluid Characteristics
Fluids: Air or nitrogen (N2), filtered at 50 µm, without condensate, lubricated or not
Max. Air Pressure (MAP): 8 bar (116 psi)
Temperature Fluid: 32ºF to 122º F (0ºC to +50ºC)
Ambient: 32ºF to 104ºF (0ºC to 40ºC)
Setpoint - Analog: 0 - 10 V (100 kW), 0/4 to 20mA (resistance 250 W)
Feedback - Analog: 0 - 10 V, 0/4 to 20 mA (max. load 500 W)
Flow accuracy
Hysteresis: ± 3%
Linearity: ± 3%
Repeatability: ± 1.5%
Calibration Conditions
Ambient Temperature: 72.5ºF±4.5ºF (22.5ºC± 2.5ºC)
Fluid: Air
Dynamic Performance
Response Time: <200 ms
Other Features: Auto-tune, error display by 3 LEDs
6. Technical Characteristics
6.2 Electrical Characteristics
Flow Regulation Range Voltage * Max. Power
(W)
Max. Current
(mA)
Insulation
Class
Degree of
Protection Electrical Connection
Up to 1000 NI/min 24 VDC = ± 10% 30 1250 H IP 65
- 5-pin M12 connector
- USB connection with 4 pin
M12 connector
2000 NI/min 24 VDC = ± 10% 34 1400 H IP 65
- 5-pin M12 connector
- USB connection with 4 pin
M12 connector
* Max. ripple: 10 %

Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
8
FlowtronicD
Installation
Manual
2-Port Control Valve with
Digital Electronics
7. Accessories
M12x1 connector
M12x1 USB connector
M4 for ground screw
0.43 (11)
4.66 (118.3)
0.83 (21)
0.09 (2.35)
1.97 (50)1.38 (35)
5.10 (129.6)
8.35 (212)
0.20 (5) 7.95 (202)
5.48 (139.2)
6.22 (158)
7.13 (181)
1/4, 3/8, 1/2
NPT or GTap
1/4, 3/8, 1/2
NPT or GTap
Mounting with
4xM4 screws from top
or 4xM5 from bottom
Weight: 4.08 (1.85)
No special maintenance or care required.
8. Maintenance and Care
9. Dimensions and Weight
PC Software & Cable Connector Model number
FlowtronicDsoftware "Numatics-FlowCom-Light" -
free download at Numatics.com 88100895
FlowtronicDsoftware "Numatics-FlowCom-Expert" - CD-ROM 88100896
USB cable for connection of FlowtronicDto PC 88100897
Micro Female 5 Pole 90 Degree 6 Wire 22 AWG Euro Color Code, Shielded
3 Meter TD0503MMS000671Y
5 Meter TD0505MMS000671Y
5 Pin 12mm FEMALE 90 DEGREE Field Attachable Connectors
PG 9 Cable Gland TD05F20000000000
5 Pin 12mm FEMALE Straight Field Attachable Connectors Model number
PG 9 Cable Gland TC05F20000000000
Micro Female 5 Pole Straight 6 Wire 22 AWG, Shielded
3 Meter TC0503MMS000671Y
5 Meter TC0505MMS000671Y

FlowtronicDManual Rev 01/12
© Numatics Inc. 2010 - 2012
World Class Supplier of Pneumatic Components
World Headquarters
USA Numatics, Incorporated
46280 Dylan Drive
Novi, Michigan 48377
P: 248-596-3200
F: 248-596-3995
Canada Numatics, Ltd
P: 519-758-2700
F: 519-452-3995
Mexico Numatics de Mexico S.A. de C.V.
P: 52-222-284-6176
F: 52-222-284-6179
Table of contents
Other Numatics Control Unit manuals