NURSAL ZX-581 User manual

www.nursal.co/warranty
facebook.com/nursalonline
Care for Your Loved Ones
ELECTRONIC PULSE MASSAGER ZX-581
USER MANUAL
TAP
KNEAU
CUPPING
ACU
NECK SHOULDER BACK
ELBOW WAIST HIP
THIGH KNEE ANKLE
RANDOM
SPEED SPEED
_+

NOTE
1. Avoid touching the pads when the unit is on.
2. Do not use near the heart, head or carotid.
3. Not for use by pregnant women.
Register within 2 weeks after receiving your new product.
www.nursal.co/warranty
PLEASE VISIT NOW
CUSTOMER SERVICE
[email protected] @nursalonline
ACTIVATE YOUR 12 MONTH WARRANTY
& GET EXCLUSIVE GIFT

A Big Thank You
We’re thrilled that you have chosen to purchase the Electric
Gooseneck Kettle. At NURSAL, we’re committed to providing you
with products that enhance your daily life. We also aim to give our
customers excellent support. Should you have any questions or
feedback about your new product, simply get in touch with our
customer support team at 1-855-556-6888, or by email at
Enjoy your new product!

CONTENTS
Introduction
Features
Safety Warnings
Environmental condition for transport and storage
Cleaning and Maintenance
Sterilization Methods
Set up
Operating the Product
Best Practices
Trouble Shooting
Use Positions Diagrams
Warranty Card
01
02
03
05
06
06
07
08
09
10
11
12

INTRODUCTION
This Electronic Pulse Massager is a user friendly product. This Electronic
Pulse Massager delivers electronic impulses to tired and sore muscles.
These impulses are generated by the device and delivered through
electrodes to the direct proximity of the target muscles. The impulses
mimic the action potential coming from the central nervous system to
trigger contraction of the muscles. Some programs will improve
resistance to fatigue and increase endurance, while others can improve
force produced by the muscle.
This device is portable, compact and stylish, as well as being controlled
by a micro-processor. It may be helpful in relieving minor aches and
pains in various parts of the body such as the waist, shoulders, Joints,
hands and feet. The device is especially helpful in relieving stiff neck
muscles and sore muscles from over exercising. Using it responsibly
and properly will provide you with a relaxing pulse massage. You will feel
a real difference this device can make to your life.
- 01 -
@nursalonline [email protected]

FEATURES
1. Liquid crystal display
2. Low frequency
3. Adjustable speed and intensity
4. 15 selectable massage models
5. 1-110Hz pulse width
6. Powered by 3 AAA batteries (1.5V)
7. Maximum operating current 10-30mA; dormant current ≤10uA
8. Included accessories: 4 pairs of electrode pads, 4 wires.
9. FDA 510(K) approved.
- 02 -
@nursalonline [email protected]

SAFETY WARNINGS
- 03 -
@nursalonline [email protected]
DANGER
1. Do not use this unit if you are using an implanted electronic medical
device such as pacemaker or other life-maintaining device.
2. Do not use this unit if you are wearing electrode medical devices
for monitoring health functions.
WARNING
1. If you have any of the following conditions, please consult your
physician before purchasing or using this device:
Acute conditions, malignant tumors, infectious diseases, pregnancy,
implanted devices, heart disease, high fever, abnormal blood
pressure, lack of skin sensation or numbness in the extremities,
abnormal skin conditions or any condition requiring the active
supervision of a physician.
2. Please remove the battery from the device when it is not in use.
NOTICE
Do not use this device while driving.
Do not use this device while sleeping.
Do not use this device in areas with high humidity such as a bathroom.
Keep this device out of reach of children.
Stop using this device and consult your physician at once if you feel pain,
discomfort, dizziness or nausea.
Do not attempt to move the electrode heads while the device is in
operation.
Do not use the device near the heart, on the head, near the mouth,
pudendum or blemished areas of skin.
Keep the device away from wet, hot place and out of direct-sunlight.
Store the device in a cool, dry place.
Do dispose of batteries according to the local laws and regulations of
your region.

- 04 -
@nursalonline [email protected]
Medical electrical equipment needs special precautions regarding
EMC and needs to be installed and put into service according to the
EMC information provided. Portable and mobile RF communication
equipment can affect medical electrical equipment.

TRANSPORT AND STORAGE SYMBOLS
- 05 -
@nursalonline [email protected]
FDA
510(K)
Fragile product
Product package
should be recycled
FDA 510(K) approved
Type B applied part
Attention, see operating
manual for user
instructions.
Keep the product in a
dry place, away from
water and rain.
Maximum of 4 stacked
cartons.

CLEANING AND MAINTENANCE
Please use water or neutral detergent to clean the device first then use a
dry cloth to wipe it again. Using volatile liquids to clean the device is
prohibited.
STERILIZATION METHODS
The electrode pads supplied with the device are disposable, and should
be replaced when their adhesiveness wears out. Contact the retailer for
replacements. Do not let the sticky side of the pad touch anything,
including greasy finger tips.
- 06 -
@nursalonline [email protected]

SET UP
Unpack the product, take the product and the batteries out and insert
the batteries into the battery compartment at the rear. Then connect the
electrode pad wires into the device.
- 07 -
@nursalonline [email protected]
TAP
KNEAU
CUPPING
ACU
NECK SHOULDER BACK
ELBOW WAIST HIP
THIGH KNEE ANKLE
RANDOM
SPEED SPEED
_+

OPERATING THE PRODUCT
1. Power button: Turns the device ON/OFF.
2. Independent channel A and channel B (A1 & A2, B1& B2), 4
channels.
3. 20 intensity levels:
Intensity “+” button: Press once to increase the strength by one level.
Intensity “-” button: Press once to decrease the strength by one level.
4. 10 pulse levels:
Speed “+” button: Press once to increase the pulse speed by one level.
Speed “-” button: Press once to increase the pulse speed by one level.
5. Auto setting:
NECK/SHOULDER/BACK/ELBOW/WAIST/HIP/THIGH/ KNEE/ANKLE
SCRAPING/TAP/CUPPING/ACU/KNEAD/RANDOM
- 08 -
@nursalonline [email protected]

BEST PRACTICE:
1. Treat the area for at most 10-15 minutes.
2. Use 1-2 times per day.
3. Select an intensity level that is comfortable for you.
4. Select a speed level that is comfortable for you.
5. Start your first session with a low intensity setting and for a short
duration while getting used to the using the device.
6. If you feel pain, dizziness, discomfort or nausea, seek medical advice
from your doctor.
- 09 -
@nursalonline [email protected]

TROUBLESHOOTING
If your device is not operating properly, please check it for the following
problems. If the recommended solution does not solve the problem,
please return it to an authorized dealer for repair.
- 10 -
@nursalonline [email protected]
PROBLEM CAUSE SOLUTION
Stimulation is
weak or non-
existent
Skin turns red
Skin feels numb
The treatment is time
too long.
The electrode heads
are dirty.
The electrode heads
are too closely
touching the skin.
Use the device for a
shorter time.
Clean with a damp
cloth.
Remove and place
on the skin again.
The electrode heads
are not in close
contact with the skin.
The electrode heads
are touching each
other.
The wires are not
connected properly
to the electrode heads
and the main device.
The batteries dead.
Remove the electrode
heads, clean them and
place them back on
the skin.
Separate the electrode
heads.
Disconnect, clean and
reconnect all parts.
Replace the batteries.

- 11 -
@nursalonline [email protected]
Device does not
turn on
Pads are not sticky Pads have deteriorated. Contact us for
replacement pads.
Batteries installed
incorrectly.
The batteries are dead.
Remove and re-install
batteries correctly.
Replace the batteries
with new ones.
AREAS ON THE BODY THE PADS CAN BE USED

- 12 -
@nursalonline [email protected]
WARRANTY CARD
Warranty Card Certificate
Product model
Product name
Date of purchase
Purchase location
Retailer’s Name
Retailer’s phone no.
Problem with the product
ZX-581
Electronic Pulse
Massager

NOTE
1. Avoid touching the pads when the unit is on.
2. Do not use near the heart, head or carotid.
3. Not for use by pregnant women.
Register within 2 weeks after receiving your new product.
www.nursal.co/warranty
PLEASE VISIT NOW
CUSTOMER SERVICE
[email protected] @nursalonline
ACTIVATE YOUR 12 MONTH WARRANTY
& GET EXCLUSIVE GIFT
Table of contents
Other NURSAL Massager manuals