Nuvico EasyTrack CK-1000 User manual


DISCLAIMER
xWhile every effort has been made to ensure that the information contained in this
guide is accurate and complete, no liability can be accepted for any errors or
omissions.
xNUVICO reserves the right to change the specifications of the hardware and
software described herein at any time without prior notice.
xNo part of this guide may be reproduced, transmitted, transcribed, stored in a
retrieval system, or translated into any language in any form, by any means, without
prior written permission of NUVICO.
xNUVICO makes no warranties for damages resulting from corrupted or lost data due
to a mistaken operation or malfunction of the Camera, peripheral devices, or
unapproved/unsupported devices.
CONTROLLER KEYBOARD 1

WARNING AND CAUTION
WARNING!
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE
VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT.
CAUTION!
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to
alert the user to the presence of uninsulated “dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instruction in the literature
accompanying the product.
CONTROLLER KEYBOARD 2

FCC COMPLIANCE STATEMENT
CONTROLLER KEYBOARD 3
CE COMPLIANCE STATEMENT
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND
FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL
DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS
ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN
A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES,
USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT
INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION
MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO
COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A
RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE
IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE
INTERFERENCE AT HIS OWN EXPENSE.
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD
VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
THIS CLASS A DIGITAL EQUIPMENT COMPLIES WITH CANADIAN
ICES-003.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A EST CONFORME À LA
NORME NMB-003 DU CANADA.
WARNING
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE
USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.

IMPORTANT SAFEGUARDS
1. Read these instructions.
2. Heed all warnings.
3. Follow all instructions.
4. Do not use this equipment near water.
5. Clean only with dry cloth.
6. Do not block any ventilation openings. Install in accordance with the manufacturer's
instructions.
7. Do not install near any heat sources such as radiators, heat registers, stoves, or
other equipment (including amplifiers) that produce heat.
8. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide blade or the third prong is
provided for your safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.
9. Protect the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles, and the point where they exit from the equipment.
10.Only use attachments/accessories specified by the manufacturer.
11.Unplug this equipment during lightning storms or when unused for long periods of
time.
12.Refer all servicing to qualified service personnel. Servicing is required when the
equipment has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the equipment, the
equipment has been exposed to rain or moisture, does not operate normally, or has
been dropped.
13.CAUTION - THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED
SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE
OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
14.Use Certified/Listed Class 2 power supply transformer only.
CONTROLLER KEYBOARD 4

TABLE OF CONTENTS
WARNING AND CAUTION............................................................................................. 2
FCC COMPLIANCE STATEMENT ................................................................................. 3
IMPORTANT SAFEGUARDS......................................................................................... 4
QUICK START PAGE..................................................................................................... 6
1. INTRODUCTION......................................................................................................... 7
2. INSTALLATION.......................................................................................................... 9
2.1 Connection Diagram.............................................................................................................................9
2.1.1 Basic Installation Diagram.....................................................................................................................................................9
2.1.2 Single DVR Configuration....................................................................................................................................................11
2.1.3 Single Controller Keyboard with Two DVR Configuration ...............................................................................................12
2.1.4 Multiple Controller Keyboard Configuration......................................................................................................................13
2.2 Termination & Dip Switch Settings ................................................................................................... 14
3. OPERATION............................................................................................................. 16
3.1 Basic Operation................................................................................................................................... 16
3.1.1 Master Controller Mode
3.2 Controller Keyboard Configuration................................................................................................... 18
.......................................................................................................................................................16
4. ADVANCED OPERATION ..................................................................................................................... 24
4.1 Selection of the Camera (ID of the Camera)..................................................................................... 24
4.2 Selection of the DVR (ID of the DVR) ................................................................................................ 24
4.3 Key Description of the Controller...................................................................................................... 24
4.4 Keys for DVR ....................................................................................................................................... 25
5. SPECIFICATION .................................................................................................................................... 27
CONTROLLER KEYBOARD 5

QUICK START PAGE
1. Controller Keyboard
CK-1000 Vx.xx
Password :
The Factory Default Password for the Controller Keyboard is “9999”.
2. DVR
[EV-Series DVR] [APEX-Series DVR]
The Factory Default Password for the DVR is “000000”. (Six zeros)
You must hold onto (Shift), and enter number keys when entering password for the
DVRs.
CONTROLLER KEYBOARD 6

1. INTRODUCTION
ABOUT THIS MANUAL
Thank you for purchasing NUVICO product.
The controller is designed to control up to 64 EasyTrakTM PTZ speed dome cameras. (It
is expandable up to 255 cameras when in simplex control mode). Rollover key functions
make it capable of controlling a variety of external switching devices such as EV / APEX
Series Digital Video Recorders.
* Before installing and using this controller keyboard, please read this manual fully
and carefully and be sure to keep it handy for later use.
Key Features
xThe capability of controlling a camera’s panning and tilting movement with
variable speed from 0.1q/sec to 90q/sec (64 speed steps). It has capability to
manually override the zoom camera’s auto focus and auto iris functions. Speed is
inversely proportional to the zoom ratio. With (Shift) key pressed, it enables
the wide zoom speed mode.
xThe ability to define and recall up to 248 presets, which are immediate camera
call-ups of preset position view, with automatic zoom and focus.
xProgram 4 patterns, which comprise a sequential series of pan, tilt, zoom, and
focus movements from a single camera.
xOne define (continuous rotation) with 16 scans.
x8 tours consisting of 64 presets, patterns, scans and alternate tours. It is
expandable to over 512 functions with nested tours.
xManual override mode of auto focus or auto iris is switched to Auto Iris/Focus
mode by slight movement of the joystick handle.
xProgrammable user preferences (alarm, preset, title, etc.).
xTwo levels of password, administrator and user, are supported for higher security.
xOne Master and multiple slave Keyboards are supported for distributed control.
xDVR system (Max 99) can be controlled remotely.
xDome cameras’ programmed data can be downloaded to none volatile memory
space in the joystick controller for the purpose of transfer to a new dome
cameras.
CONTROLLER KEYBOARD 7

Content Verification
Before installing the controller Keyboard, please make sure that the following items are
included in the box:
1. Controller Keyboard
2. 12VDC SMPS Power Transformer
3. Power Cord
4. This Instruction Manual
5. Junction Box: J-Box (Optional)
6. 3m Cable: Data cable (Optional)
7. M4 Self Tapping Screws (Optional)
If any of these materials are missing, please contact your distributor or NUVICO
Technical Support for assistance.
CONTROLLER KEYBOARD 8

2. INSTALLATION
2.1 Connection Diagram
2.1.1 Basic Installation Diagram
4 ALARM INPUT
1 AUX OUTPUT
HEATER
AC24V
AC24V
POWER
DOME
CONTROLLER
RXA
RXB
RS-485
HALF DUPLEX MODE
VIDEO
POWER
AC 24V
STP AWG#22
REAR
REAR
STP AWG#22
AC 24V
POWER
COM Port of the DVR
RS-485+/RS-485-
RS-485+
RS-485-
CONTROLLER KEYBOARD 9

Figure 1 – Basic installation diagram (w/o J-Box)
Figure 2 – Basic installation diagram with J-Box
CONTROLLER KEYBOARD 10

2.1.2 Single DVR Configuration
AC 24V
POWERPOWER
AC 24V
BNC
SPOT MONITOR MAIN MONITOR
BNC
BNC
AWG # 24
HALF DUPLEX MODE
RS-485
RXB
RXA RS-485-
RS-485+
CONTROLLER
DOME
VIDEO
RS-485+/RS-485-
POWER
AC24V
AC24V
HEATER
1 AUX OUTPUT
4 ALARM INPUT
RS-485+
RS-485-
Figure 3 – Single DVR
CONTROLLER KEYBOARD 11

2.1.3 Single Controller Keyboard with Two DVR Configuration
CONTROLLER KEYBOARD 12
4 ALARM INPUT
1 AUX OUTPUT
HEATER
AC24V
AC24V
POWER
RS-485+/RS-485-
VIDEO
AWG # 24
BNC
MAIN MONITORSPOT MONITOR
BNC
AC 24V
POWER POWER
AC 24V
RS-485+
MAIN MONITOR
RS-485-
Camera 1~16 Camera 17~12( 15)
Figure 4 – Two DVR

2.1.4 Multiple Controller Keyboard Configuration
Camera 17~12( 15)Camera 1~16
AWG # 24
BNC
AC 24V
POWER POWER
AC 24V
1ST MAIN MONITOR 2ND MAIN MONITORSPOT MONITOR
4 ALARM INPUT
1 AUX OUTPUT
HEATER
AC24V
AC24V
POWER
VIDEO
RS-485+
RS-485-
RS-485+/RS-485-
Figure 5 – Two DVR with Slave Controller
Master K/B Setup
Shft
CONTROLLER KEYBOARD 13
+ Menu ÎPort ÎSlave
SLAVE SETUP MENU
Device : Controller
Baud Rate : 9600bps
Slave K/B Setup
Shft ÎNetworks+ Menu
NETWORKS
Slave ID :1 --- ID setup
Baud Rate : 9600bps

2.2 Termination & Dip Switch Settings
The first and last devices in an installation (dome and controller keyboard) must have
the data line terminated by setting the DIP switch. Without proper termination, there
may be control signal errors. Total length of the cable for communication should not
exceed 0.74 Mile or 1.2 Kilometer.
SW1:Termination ON
TERMINATION ON
S1:Dome1 port Termination On
S3:Dome2Termination ON
Repeater
DVR Termination ON
SW1:Termination ON
SW1:Termination ON
S1:Dome1 port Termination On DVR Termination ON
SW1:Termination ON
SW1:Termination ON SW1:Termination ON
SW1:Termination ON SW1:Termination ON
DVR Termination ON
S4:DVR port Termination On
S1:DOme1 port Termination On DVR Termination ON
SW1:Termination ON SW1:Termination ON
S1:DOme1 port Termination On
TERMINATION ON
Figure 6 – Termination
CONTROLLER KEYBOARD 14

CONTROLLER KEYBOARD 15
S4:DVR Port Termination ON
DATA1
DATA1
IN OUT
S5:Slave port termination ON
Last DVR
DVR2
DVR1
S1:Dome1 Port Termination ON
DVR Terminatio
SW1:Termination ON SW1:Termination ON
S8:Slave mode ON S8:Slave mode ON S8:Slave mode ON
n ON
TRX1
DC 12V
+
S1:DOME1 PORT TERMINATION
S2:DOME2 PORT TERMINATION
S3:SLAVE PORT TERMINATION
S4:DVR PORT TERMINATION
DATA1 DATA2
S1
OFF
ON
S8:OFF-MASTER /
S7:RESERVED
S6:RESERVED
S5:RESERVED
ON-SLAVE
-G G-+
TRX2
RS-485
S2 S3 S4
S1
1234
Figure 8 – Termination and Switches
Figure 9 – Termination of Slave controller
Figure 7 – Rear View of the Keyboard
S5 S6 S7 S8
S2
4321

3. OPERATION
3.1 Basic Operation
Principal of operation in the programming (editing) mode.
Button or Joystick movement in menu Function
Joystick
left or right
Go into the sub-menu items.
Execute the command(exit)
Change value.
Navigate through the menu items.
Joystick
up or down Navigate through the menu items.
Zoom
handle twist Change value.(Increase / Decrease)
Enter editing title mode.
SHFT + Joystick
Turbo speed.
ESC
Escape from the menu without change.
Home
or
Off
button Delete value or name of the field.
3.1.1 Master Controller Mode
As the DIP S/W position 8 OFF, the joystick controller works as master controller. Position 8 ON,
controller will work as slave controller.
When the joystick controller is powered on, a password will be required to access the controller keyboard.
CONTROLLER KEYBOARD 16
Master Controller mode
CK-1000 Vx.xx
Password :
CK-1000 Vx.xx
Password :
S8 ON : Slave Controller mode
Unless you have changed the passwords, the factory default for the administrator’s password is 9999+Enter and
1111+Enter for the user-level password.
If you have forgotten your password and are no longer able to access the administrative
controls to your unit, please contact your distributor or NUVICO Technical Support for
assistance.
Press and then consecutively. (9999+Enter), , ,
9
,
9
,
9
,
9

The controller keyboard will be displayed the following screen and is ready to control dome cameras.
CAMERA
Press key will get you back to system mode (camera control) from DVR control
LCD display in System mode
Cam : 001N
Camera ID & Time
PM 09 : 34 : 04
When you need to control the DVR, press key. The LCD screen will be shown following DVR mode.
DVR
LCD display in DVR mode
DVR : 001 Cam : 001N
CONTROLLER KEYBOARD 17
PM 09 : 34 : 04
Press key to go back to the system mode from the DVR control mode.
CAMERA

3.2 Controller Keyboard Configuration
If the user needs to setup the network, change passwords, or perform special tasks such as Uploading
and Downloading programmed data from the dome cameras, hold down key, and then press key
(Shift + Menu.) You will see the following menu. Joystick Up/Down scrolls menu items, turn the joystick
to Right to enter the sub-menu.
MAIN MENU ( + = Shft + Menu )
CONTROLLER KEYBOARD 18
Configuration
Port
Camera
DVR
Time/Date
Alarm
Alias Preset
Schedule
Data
Slave Control SetUp
LCD
Exit
Key Beep : ON / OFF
Key Lock : NO / 1Min ~30Min
Chg User Password
Chg Admin Password
Factory Default
Sa
v
e
a
n
d
Exi
t
MASTER MENU SLAVE MENU
Configuration
Networks
Time/Date
LCD
Exit
Slave Controller Mode
(
S8 ON
)
Master Controller mode
CONFIGURATION (Shft + Menu ÎCONFIGURATION)
Key Beep : ON / OFF
Alarm Beep : ON / OFF
Key Lock : NO / 1Min ~30Min
Chg User Password
Chg Admin Password
Factory Default
Save and Exit
Slave Controller Mode
(
S8 ON
)
- Key Beep: ON - Enable key beep sound
OFF - Disable beep sound.
- Key Lock: 1Min ~ 30Min - After elapsed setup time, keyboard locks automatically.
NO - Disable Auto Key-Lock function.
User needs the login password to operate the Keyboard again.
- User Password: Simple operation (changing setup and programming disabled)
Password: Enter current user’s password.
New Password: Enter 1~6 digits new password.
Confirm Password: Confirm 1~6 digits new password.
- Admin Password: Fully accessible menu (changing setup and programming enabled)
Password: Enter current admin password.
New Password: Enter 1~6 digits for new password.
Confirm Password: Confirm 1~6 digits for new password.
Note: Factory default Administrator’s password is 9999+Enter and user password is 1111+Enter.

- Factory Default: This function is used to reset the controller keyboard to the factory default setting,
It will erase all data and programming.
- Save and Exit: Save the programmed data and return to the previous Menu
(To exit without saving, press key)
CONTROLLER KEYBOARD 19
Dome1
Dome2
Slave
DVR
Alarm
Exit
Device : Camera / DVR / None
Baud Rate : 9600 / 2400~230K
Save and Exit
Device : Camera / AUX IN
/ AUX I/O / None
Baud Rate : 9600 / 2400~230K
Save and Exit
PORT (Shft + Menu ÎPORT) NETWORKS (Shft + Menu ÎNETWORKS)
Slave ID : 1
Baud rate : 9600
Save and Exit
Master Controller mode
Dome1 (Shft + Menu ÎPORT
Î
Dome1)
Device: Select Device to be controlled (Camera / DVR / None)
Baud Rate: Communication speed (2400/ 4800/ 9600/19200/ 38400/ 57600/ 11.5K /230K)
Save and Exit, Press key to exit without saving the data.
ESC
ESC
Slave Controller Mode
(
S8 ON
)
Dome2 (Shft + Menu ÎPORT
Î
Dome2)
Device: Select Device to be controlled (Camera / AUX IN / AUX I/O / None)
Baud Rate: Communication speed (2400/ 4800/ /19200/ 38400/ 57600/ 11.5K /230K)9600
ave and Exit, Press key to exit without saving the data.S
ESC