nuVita 1300 User manual

Nuvita 1300 - Digital baby scale
EN
1. Description
3. Batteries installation
6. Unit selector function
7. Funzione COMPARISON ( )
4. Normal weighing function
NOTE
2. Specications
ON/OFF button View baby's weight and other information
on how
[TARE] button Switch ON or OFF the scale.
[Kg / lb:oz] button Allows you to deduct initial tare weight.
button Allows you to change weight unit
Tasto Allows you to use COMPARISON function,
explained in this manual.
Range: from 0,02 Kg to 18 Kg / from 1 oz
to 40 lbs
Graduation: 5 gr. / 5 oz
Power supply: 2 x batteries AA (3,0 VDC)
Battery indicator: Battery icon will ash “ ” if battery
power is down.
Display: Backlighted LCD panel.
Display dimensions: 69 x 32,5 mm
Dimensions: 540 x 345 x 57 mm
Net weight: 1,95 Kg
Storage environment: -10°C – 55°C
Operating environment: 10°C – 40°C
0.2kg-3.995kg (0.005kg)
Precision of weight
measurements:
4kg-9.995kg (0.010kg)
10kg-18kg (0.015kg)
Turn the scale and remove the battery cover which is located at
the bottom.
Insert two standard batteries size AA being sure to observe the
polarity indicated in the battery compartment
Close the batteries cover and place the scale on a at and hard
surface to weight the baby. Carpet of soft surface is not suitable
for weighing.
Before putting a baby on the scale, be sure that the surface of the
scale is completely dry and not slippery.
Press “ ”to switch ON the scale.
Before putting the baby onto the scale, press [Kg/lb:oz] button to
select the weight unit.
Determined weight unit will show when the scale is switched ON
next time.
This feature allows you to weigh the amount of milk or food
given to the baby during meals.
After feeding the baby, press “ ”
button once to switch ON the scale.
Four bars and battery icon will show and
change to g.7.4.appariranno quattro
trattini.
The weight of the baby before feeding
will show.
(NOTE: This is a minus gure)
Since a baby is a moving object, the weight on the display will
uctuate during weighing process. It will take 15 seconds for the
scale to catch a weight of the moving baby and lock it. The locked
weight will show 10 seconds and then the scale will switch o
automatically).
Press “ ” button to switch ON the scale.
Four bars and battery icon will show and
change to g.4.2.
“0.000 Kg”and battery icon will show.
“0:0 lb:oz” will showif this uniti s selected.
Place the blanket on the scale. Weight of
the blanket will show.
When “Hold” appears press the [TARE]
button immediatly.
“0.000 Kg”(0:0 lb:oz will show if this uniti s
selected), TARE and battery icons will show.
NOTE: Leave the blanket on the scale. If
you remove the blanket from the scale, the
display will show a negative weight.
Put the naked baby onto the blanket. Net
weight of the naked baby will show when
“Hold” appears. The scale will switch o
automatically after 10 seconds.
“0.000 Kg”and battery icon will show.
“0:0 lb:oz” will show if lb:oz uniti s
selected.
Put the baby onto the scale. The weight is
determined when “Hold” appears.
“Err” will show if the scale is overloaded.
Press “ ”button to switch ON the scale.
Four bars and battery icon will show and
change to g.5.2.
1.
2.
3.
4.
1.
2.
3.
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
2.
3.
4.
1.
Fig. 4.1
Fig. 4.2
Fig. 4.3
Fig. 4.4
Fig. 5.1
5. TARE function
This feature allows you to weigh and to exclude the weight of any
tissue or blanket placed on the scale when weighing the baby
naked.
Fig. 5.2
Fig. 5.3
Fig. 5.4
Fig. 5.5
Fig. 5.6
Fig. 5.7
Fig. 7.3
Fig. 7.4

Put the baby fed with milk onto the scale,
weight of milk fe to the baby will show.
5.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fig. 7.5
EXAMPLE
WARRANTY - TERMS AND CONDITIONS
Warning and general safety rules
If the weight of the baby before feeding is 8,0 Kg, this 8,0 Kg will be
stored after the baby is weighed by using normal weighing function
(see chapter 4). “-8,000 Kg”(minus 8,0 Kg) will show when this “ ”
button is pressed. Then put the baby with milk fed on the scale.
Weight of the milk fed to the baby will show. If the baby is fed with
320 gr. (weight) of milk, “0,320 Kg” will show. The total weight of the
baby with milk fed is:
8,000 Kg + 0,320 Kg = 8,320 Kg
The scale will switch OFF automatically after 10 seconds.
This product benets of a warranty of 24 months on material and
manufacturing defects, starting from the date of purchase (see sales
slip).
The warranty of 24 months does not include damages caused by the
usual use of parties identied as “consumable”(e.g., batteries, brush
heads or parts subject to usury).
The legal guarantee of 24 months is void if:
The manufacturer, distributor and all the parties involved in the
sale do not assume any liability for losses and economic damage
from any malfunction of the product. In accordance with current
regulations the manufacturer, distributor and all the parties
involved in the sale are not responding in any case for damages,
including direct, indirect ones, loss of net income, loss of savings
and additional damage and other details consequences going
beyond the damage caused by the breach of warranty, contract,
strict liability, wrongdoing or due to other causes, resulting from
the use or inability to use the product and/or paper and electronic
documents, including the lack of service.
For further information on the help service visit the website www.
nuvitababy.com
The following is excluded from the legal guarantee of 24 months:
Read the instructions of this manual before using this appliance.
It contains important information regarding the use of this
appliance and safety rules.
Any incorrect operation and improper use may damage the
appliance and cause danger to the user.
Never leave the baby unattended during weighing
Use the scale only to weight babies below the maximum
capacity. Over loading will cause damage and danger.
To clean the balance use a soft cloth dampened with a bit of
water. Do not immerse the scale in liquid or rinse under running
water.
For cleaning do not use detergents or solvents aggressive or
abrasive
When the scale is in use, keep away from any electromagnetic
wave source such as microwave oven, mobile phones and
wireless network.
Do not short circuit the battery poles.
Do not try to repair the appliance by yourself to avoid any
dangers related to electricity.
Never let children play with any packing materials, especially
plastic bags. Plastic bags may cause suocation.
In case o fan electrostatic malfunction, reinstall batterie sto
resume normal performances.
If the display shows the error message“Err”, switch OFF the scale.
Then switch ON again and follow the instructions.
Never leave anything onto the platform of scale when not in use.
Do not use the balance to a sustained load as it can damage the
mechanism of measurement.
Stored weight record will be deleted when new batteries are
inserted.
The scale will switch OFF automatically in1 minute after the
scale is switched ON and not in use. To switch OFF the scale
immediatly, press “ ” button and hold about half second.
Avoid abrupt movement or that the scale falls.
The scale is intended for private use and to measure the weight
of the baby. It is not allowed to use the scale in medicine or for
purposes other than private use.
As the scale is intended exclusively for private use is exempt
from the requirement to submit the instrument to the periodic
inspections of the law, stating that they are to protect the
accuracy and reliability of the regularity of transactions.
The product has undergone aesthetic damage due to improper
use not in accordance with instructions in the manual.
This product has been modied and/or tampered with.
The cause of the failure was due to poor maintenance of the
individual components and/or accessories and/or supplies (e.g.
oxidation and/or scaling due to the retention of water or other
liquids, sediment blocking the sensor, leak of corrosive liquid from
batteries).
Costs related to replacements and/or repair of parts subject to
wear or costs for ordinary maintenance of the product.
The costs and risks involved in transporting the product to and
from the store where you purchased or otherwise authorized
collection centre to receive the products under warranty.
Damage caused by or resulting from improper installation
or improper use not in accordance with the directions in the
instruction manual.
Damage due to natural disasters, accidental events or adverse
conditions not compatible with the product.
Defects that have a negligible eect on product performance.
Other manuals for 1300
1
Other nuVita Scale manuals