Nvidia Spectrum SN2000 Instructions for use

Exported on Sep/19/2022 02:25 PM
NVIDIA Spectrum SN2000 1U Switch Systems
Hardware User Manual
10/25/40/50/100GbE Open Ethernet Switch Systems Models: SN2700, SN2740, SN2410,
SN2201, SN2100, SN2010

2
Table of Contents
Ordering Information .......................................................................... 6
SN2700 Ordering Part Numbers ....................................................................6
SN2410 Ordering Part Numbers ....................................................................7
SN2100 Ordering Part Numbers ....................................................................8
SN2010 Ordering Part Numbers ....................................................................9
SN2201 Ordering Part Numbers ....................................................................9
Introduction....................................................................................11
Speed and Switching Capabilities ............................................................... 13
Management Interfaces, PSUs and Fans ........................................................ 14
Features ............................................................................................. 15
Certifications ....................................................................................... 15
Installation.....................................................................................16
System Installation and Initialization ........................................................... 16
Safety Warnings .................................................................................... 16
Air Flow.............................................................................................. 17
Package Contents .................................................................................. 18
System Mounting Options ......................................................................... 19
SN2700 Static Rail Kit ............................................................................. 19
Removing the System from the Rack........................................................ 23
SN2700 Telescopic Rail Kit ........................................................................ 24
Removing the System from the Rack........................................................ 27
SN2740/SN2410 Static Rail Kit ................................................................... 28
SN2100/SN2010 Side by Side Mounting Rail Kit................................................ 31
SN2100/SN2010 Static Single Switch Rail Kit .................................................. 36
SN2201 Tool-Less Rail Kit ......................................................................... 38
Tool-Less 4-Post Mounting Rail-Kit........................................................... 38
Tool-Less 2-Post Mounting Rail-Kit........................................................... 42
Cable Installation .................................................................................. 44
Splitter (Breakout) Cables and Adapters ................................................... 46
Initial Power On .................................................................................... 49
System Bring-Up.................................................................................... 50
Configuring Network Attributes Using NVIDIA Onyx (MLNX-OS) ......................... 50

3
Configuring Network Attributes Using Cumulus Linux .................................... 54
FRU Replacements ................................................................................. 54
Power Supply ................................................................................... 54
Fans .............................................................................................. 55
Interfaces ......................................................................................57
Data Interfaces ..................................................................................... 57
Supported Passive Cables in SN2010bM..................................................... 58
Speed ................................................................................................ 58
I2C/RS232 (Console) ............................................................................... 59
Management ........................................................................................ 59
USB ................................................................................................... 59
Reset Button ........................................................................................ 60
Status and Port LEDs............................................................................... 60
LED Notifications................................................................................... 60
System Status LEDs ............................................................................ 61
Fan Status LEDs ................................................................................ 62
Power Supply Status LEDs..................................................................... 63
Unit Identification LED........................................................................ 65
Bad Port LED .................................................................................... 65
Port LEDs ........................................................................................ 66
Inventory Information ............................................................................. 68
Software Management .......................................................................71
Upgrading Software................................................................................ 71
NVIDIA Onyx (MLNX-OS) Software Upgrade................................................. 71
Switch Firmware Update...................................................................... 71
Cumulus Linux Software Upgrade ........................................................... 71
Troubleshooting ...............................................................................72
Specifications..................................................................................74
SN2700 Series....................................................................................... 74
SN2740 Series (End of Life)....................................................................... 75
SN2410 Series....................................................................................... 75
SN2100 Series....................................................................................... 76
SN2010 Series....................................................................................... 77
SN2201 Series....................................................................................... 78

4
Appendixes.....................................................................................80
Accessory and Replacement Parts ............................................................... 80
Thermal Threshold Definitions................................................................... 81
Interface Specifications........................................................................... 82
QSFP28 Pin Description ....................................................................... 82
SFP28 Pin Description ......................................................................... 84
RJ-45 CONSOLE and I²C Interface ........................................................... 85
RJ45 to DB9 Harness Pinout .................................................................. 86
RJ45 to RJ45 Harness.......................................................................... 86
Disassembly and Disposal ......................................................................... 87
Disassembly Procedure........................................................................ 87
Disposal.......................................................................................... 87
Document Revision History ..................................................................89

5
Relevant for Models: SN2700, SN2740, SN2410, SN2100, SN2010 and SN2201.
About this Manual
This manual describes the installation and basic use of NVIDIA Ethernet switches based on the NVIDIA
Spectrum IC device.
Ordering Information
SeeIntroduction.
Intended Audience
This manual is intended for IT managers and system administrators.
Related Documentation
Document Description
1NVIDIA Onyx (MLNX-OS) User Manual This document contains information regarding the
configuration and management of the NVIDIA
Onyx (MLNX-OS) software. See https://
www.nvidia.com/en-us/networking/ethernet-
switching/onyx/.
2Cumulus Linux User Guide This document contains information regarding the
configuration and management of the Cumulus®
Linux® software. See https://docs.nvidia.com/
networking-ethernet-software/cumulus-linux-51/
.
3Open Network Install Environment
(ONIE) Quick Start Guide
See https://github.com/opencomputeproject/
onie/wiki/Quick-Start-Guide/.
4Hands-on workshops Cumulus on-site/remote training: https://
academy.nvidia.com/en/cumulus-linux-boot-
camp/
NVIDIA Onyx on-site/remote training: https://
academy.nvidia.com/en/course/onyx/?cm=242
5On-site/remote services For any tailor-made service, contact nbu-
Revision History
A list of the changes made to this document are provided in Document Revision History.

6
Ordering Information
The following table lists ordering information for the available systems.
Please pay attention to the airflow direction when ordering your system. For more details, seeAir
Flow.
SN2700 Ordering Part Numbers
Part Number Legacy Part
Number
Marketing Description
920-9N101-00F4-
0X0
MSN2700-BS2F NVIDIA Spectrumbased 40GbE, 1U Open Ethernet Switch with NVIDIA
Onyx (MLNX-OS), 32 QSFP28 ports, 2 Power Supplies (AC), x86 CPU,
Standard depth, P2C airflow, Rail Kit, RoHS6
920-9N101-00F4-
0C0
MSN2700-BS2FC NVIDIA Spectrum40GbE 1U switch w/Cumulus Linux, 32 QSFP28
ports, 2 AC PSUs, x86 2-core, standard depth, P2C airflow, Rail Kit,
RoHS6, (Cumulus License Key is required)
920-9N101-00R4-
0X0
MSN2700-BS2R NVIDIA Spectrumbased 40GbE, 1U Open Ethernet Switch with NVIDIA
Onyx (MLNX-OS), 32 QSFP28 ports, 2 Power Supplies (AC), x86 CPU,
Standard depth, C2P airflow, Rail Kit, RoHS6
920-9N101-00F7-
0X0
MSN2700-CB2F Mellanox Spectrum based 100GbE 1U Open Ethernet Switch with
Onyx, 32 QSFP28 ports, 2 Power Supplies (AC), x86 CPU, short depth,
P2C airflow, Rail Kit
920-9N101-00R7-
0X0
MSN2700-CB2R Spectrum based 100GbE, 1U Open Ethernet Switch with Onyx, 32
QSFP28 ports, 2 Power Supplies (AC), x86 CPU, Short depth, Reverse
airflow, Rail Kit, RoHS6
920-9N101-00F7-
1C1
MSN2700-CSBFC Mellanox Spectrum based 100GbE 1U Open Ethernet Switch with
Cumulus Linux, 32 QSFP28 ports, 2 Power Supplies (DC), x86 CPU,
standard depth, P2C airflow, Rail Kit
920-9N101-00F7-
0X4
MSN2700-CS2F NVIDIA Spectrumbased 100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx (MLNX-OS), 32 QSFP28 ports, 2 Power Supplies (AC), x86
CPU, Standard depth, P2C airflow, Rail Kit, RoHS6
920-9N101-00F7-
0C1
MSN2700-CS2FC NVIDIA Spectrum100GbE 1U switch w/Cumulus Linux, 32 QSFP28
ports, 2 AC PSUs, x86 2-core, standard depth, P2C airflow, Rail Kit,
RoHS6, (Cumulus License Key is required)
920-9N101-00F7-
0N1
MSN2700-CS2FO NVIDIA Spectrumbased 100GbE 1U Open Switch with ONIE, 32
QSFP28 ports, 2 Power Supplies (AC), Standard depth, x86 CPU, P2C
airflow, Rail Kit, RoHS6
920-9N101-00R7-
0X2
MSN2700-CS2R NVIDIA Spectrumbased 100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx (MLNX-OS), 32 QSFP28 ports, 2 Power Supplies (AC), x86
CPU, Standard depth, C2P airflow, Rail Kit, RoHS6
920-9N101-00R7-
0C0
MSN2700-CS2RC NVIDIA Spectrum100GbE 1U switch w/Cumulus Linux, 32 QSFP28
ports, 2 AC PSUs, x86 2-core, standard depth, C2P airflow, Rail Kit,
RoHS6, (Cumulus License Key is required)
920-9N101-00R7-
0N0
MSN2700-CS2RO NVIDIA Spectrum based 100GbE 1U Open Ethernet switch with ONIE,
32 QSFP28 ports, 2 power supplies (AC), x86 CPU, standard depth,
C2P airflow, Rail Kit

7
Part Number Legacy Part
Number
Marketing Description
920-9N101-00F7-
1N0
MSN2700-CBBFO NVIDIA Spectrum based 100GbE, 1U Open Ethernet Switch with ONIE,
32 QSFP28 ports, 2 power-supplies (DC), x86 CPU, short depth, P2C
airflow, Rail Kit
SN2410 Ordering Part Numbers
Part Number Legacy Part
Number
Marketing Description
920-9N112-00F7-0
X0
MSN2410-BB2F Mellanox Spectrum based 10GbE/100GbE 1U Open Ethernet switch
with Onyx, 48 SFP28 ports and 8 QSFP28 ports, 2 Power Supplies
(AC), x86 CPU, short depth, P2C airflow, Rail Kit
920-9N112-00F7-0
C3
MSN2410-BB2FC NVIDIA Spectrum10GbE/100GbE switch w/Cumulus Linux, 48 SFP28
ports + 8 QSFP28 ports, 2 AC PSUs, x86 2-core, short depth, P2C air
flow, Rail Kit, (Cumulus License Key is required)
920-9N112-00F7-0
N3
MSN2410-BB2FO NVIDIA Spectrumbased 10GbE/100GbE 1U Open Ethernet switch with
ONIE, 48 SFP28 ports, 8 QSFP28 ports, 2 power supplies (AC), x86
dual core, Short depth, P2C airflow, Rail Kit, RoHS6
920-9N112-00R7-
0X2
MSN2410-BB2R NVIDIA Spectrumbased 10GbE/100GbE 1U Open Ethernet switch with
NVIDIA Onyx (MLNX-OS), 48 SFP28 ports, 8 QSFP28 ports, 2 power
supplies (AC), x86 dual core, Short depth, C2P airflow, Rail Kit,
RoHS6
920-9N112-00R7-
0N1
MSN2410-BB2RO NVIDIA Spectrum based 10GbE/100GbE 1U Open Ethernet switch with
ONIE, 48 SFP28 ports and 8 QSFP28 ports, 2 power supplies (AC), x86
CPU, short depth, C2P airflow, Rail Kit
920-9N112-00R7-
0C3
MSN2410-BB2RC NVIDIA Spectrum based 10GbE/100GbE 1U Open Ethernet switch with
Cumulus Linux, 48 SFP28 ports and 8 QSFP28 ports, 2 power supplies
(AC), x86 CPU, short depth, C2P airflow, Rail Kit
920-9N112-00F7-0
X2
MSN2410-CB2F NVIDIA Spectrumbased 25GbE/100GbE 1U Open Ethernet switch with
NVIDIA Onyx (MLNX-OS), 48 SFP28 ports, 8 QSFP28 ports, 2 power
supplies (AC), x86 dual core, Short depth, P2C airflow, Rail Kit,
RoHS6
920-9N112-00F7-0
C2
MSN2410-CB2FC NVIDIA Spectrum25GbE/100GbE switch w/Cumulus Linux, 48 SFP28
ports + 8 QSFP28 ports, 2 AC PSUs, x86 2 core, short depth, P2C air
flow, Rail Kit, (Cumulus License Key is required)
920-9N112-00F7-0
N2
MSN2410-CB2FO NVIDIA Spectrumbased 25GbE/100GbE 1U Open Ethernet switch with
ONIE, 48 SFP28 ports, 8 QSFP28 ports, 2 power supplies (AC), x86
dual core, Short depth, P2C airflow, Rail Kit, RoHS6
920-9N112-00R7-
0X1
MSN2410-CB2R NVIDIA Spectrumbased 25GbE/100GbE 1U Open Ethernet switch with
NVIDIA Onyx (MLNX-OS), 48 SFP28 ports, 8 QSFP28 ports, 2 power
supplies (AC), x86 dual core, Short depth, C2P airflow, Rail Kit,
RoHS6
920-9N112-00R7-
0C2
MSN2410-CB2RC NVIDIA Spectrum25GbE/100GbE switch w/Cumulus Linux, 48 SFP28
ports + 8 QSFP28 ports, 2 AC PSUs, x86 2 core, short depth, C2P air
flow, Rail Kit, (Cumulus License Key is required)

8
Part Number Legacy Part
Number
Marketing Description
920-9N112-00R7-
1C0
MSN2410-CBBRC NVIDIA Spectrum based 25GbE/100GbE 1U Open Ethernet switch with
Cumulus Linux, 48 SFP28 ports and 8 QSFP28 ports, 2 power supplies
(DC), x86 CPU, short depth, C2P airflow, Rail Kit
SN2100 Ordering Part Numbers
Legacy Part
Number
Part Number Marketing Description
920-9N100-00F4-0
X0
MSN2100-BB2F Mellanox Spectrum based 40GbE 1U Open Ethernet Switch with Onyx,
16 QSFP28 ports, 2 Power Supplies (AC), x86 CPU, short depth, P2C
airflow. Rail Kit must be purchased separately
920-9N100-00F4-0
C0
MSN2100-BB2FC NVIDIA Spectrum40GbE 1U switch w/Cumulus Linux, 16 QSFP28
ports, 2 AC PSUs, x86 2 core, short depth, P2C airflow, Rails to be
purchased separately, (Cumulus License Key is required)
920-9N100-00R4-0
X0
MSN2100-BB2R NVIDIA Spectrumbased 40GbE, 1U Open Ethernet Switch with NVIDIA
Onyx (MLNX-OS), 16 QSFP28 ports, 2 AC PSUs, x86 2-core, short
depth, C2P airflow, Rail Kit must be purchased separately, RoHS6
920-9N100-00R4-0
N0
MSN2100-BB2RO NVIDIA Spectrum based 40GbE 1U Open Ethernet switch with ONIE,
16 QSFP28 ports, 2 power supplies (AC), x86 CPU, short depth, C2P
airflow. Rail Kit must be purchased separately
920-9N100-00F7-0
X0
MSN2100-CB2F NVIDIA Spectrumbased 100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx (MLNX-OS), 16 QSFP28 ports, 2 AC PSUs, x86 2-core,
short depth, P2C airflow, Rail Kit must be purchased separately,
RoHS6
920-9N100-00F7-0
C0
MSN2100-CB2FC NVIDIA Spectrum100GbE 1U switch w/Cumulus Linux, 16 QSFP28
ports, 2 AC PSUs, x86 2-core, short depth, P2C airflow, Rails to be
purchased separately, (Cumulus License Key is required)
920-9N100-00F7-0
N0
MSN2100-CB2FO NVIDIA Spectrumbased 100GbE 1U Open Switch with ONIE, 16
QSFP28 ports, 2 AC PSUs, x86 2-core, short depth, P2C airflow, Rail
Kit must be purchased separately, RoHS6
920-9N100-00R7-0
X0
MSN2100-CB2R NVIDIA Spectrumbased 100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx (MLNX-OS), 16 QSFP28 ports, 2 AC PSUs, x86 2-core,
short depth, C2P airflow, Rail Kit must be purchased separately,
RoHS6
920-9N100-00R7-0
C0
MSN2100-CB2RC NVIDIA Spectrum100GbE 1U switch w/Cumulus Linux, 16 QSFP28
ports, 2 AC PSUs, x86 2-core, short depth, C2P airflow, Rails to be
purchased separately, (Cumulus License Key is required)
920-9N100-00R7-0
N0
MSN2100-CB2RO NVIDIA Spectrum based 100GbE 1U Open Ethernet switch with ONIE,
16 QSFP28 ports, 2 power supplies (AC), x86 CPU, short depth, C2P
airflow. Rail Kit must be purchased separately

9
SN2010 Ordering Part Numbers
Part Number Legacy Part
Number
Marketing Description
920-9N110-00F7-0
X2
MSN2010-CB2F NVIDIA Spectrum-based 25GbE/100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx, 18 SFP28 and 4 QSFP28 ports, 2 Power Supplies (AC),
short depth, x86 quad core, P2C airflow, Rail Kit must be purchased
separately
920-9N110-00F7-0
C3
MSN2010-CB2FC
NVIDIA Spectrum-based 25GbE/100GbE 1U switch w/Cumulus Linux, 18
SFP28 and 4 QSFP28 ports, 2 AC PSUs, x86 4-core, short depth, P2C
airflow, Rails to be purchased separately, (Cumulus License is provided
at no cost with purchase of SUP-SN2010-CL-XX)
920-9N110-00F7-0
C0
MSN2010-CB2F3C NVIDIA Spectrum based 25GbE/100GbE, 1U Open Ethernet switch with
Cumulus Linux, 18 SFP28 and 4 QSFP28 ports,2 power supplies (AC),
x86 CPU, 32G RAM and 30G SSD, short depth, P2C airflow, Rail Kit
must be purchased separately
920-9N110-00F7-0
N0
MSN2010-CB2FO
NVIDIA Spectrum-based 25GbE/100GbE, 1U Open Ethernet Switch with
ONIE, 18 SFP28 ports and 4 QSFP28 ports, 2 Power Supplies (AC), x86
quad core, short depth, P2C airflow, Rail Kit must be purchased
separately
920-9N110-00R7-0
X2
MSN2010-CB2R NVIDIA Spectrum-based 25GbE/100GbE, 1U Open Ethernet Switch with
NVIDIA Onyx, 18 SFP28 ports and 4 QSFP28 ports, 2 Power Supplies
(AC), short depth, x86 quad core, C2P airflow, Rail Kit must be
purchased separately
920-9N110-00R7-0
C2
MSN2010-CB2RC Spectrum-based 25GbE/100GbE 1U switch w/Cumulus Linux, 18 SFP28
and 4 QSFP28 ports, 2 AC PSUs, x86 4-core, short depth, C2P airflow,
Rails to be purchased separately, (Cumulus License is provided at no
cost with purchase of SUP-SN2010-CL-XX)
920-9N110-00R7-0
N0
MSN2010- CB2RO NVIDIA Spectrum based 25GbE/100GbE 1U Open Ethernet switch with
ONIE, 18 SFP28 ports and 4 QSFP28 ports, 2 power supplies (AC), x86
CPU, short depth, C2P airflow. Rail Kit must be purchased separately
SN2201 Ordering Part Numbers
Part Number Legacy Part
Number
Marketing Description
920-9N110-00F1-0
C0
MSN2201-CB2FC Nvidia Spectrum based 1GBase-T/100GbE 1U Open Ethernet switch
with Cumulus Linux, 48 RJ45 ports and 4 QSFP28 ports, Dual Power
Supply (AC), x86 CPU, short depth, P2C airflow, 4-post Rail kit.
920-9N110-00F1-0
N1
MSN2201-CB2FO Nvidia Spectrum based 1GBase-T/100GbE 1U Open Ethernet switch
with ONIE, 48 RJ45 ports and 4 QSFP28 ports, Dual Power Supply (AC),
x86 CPU, short depth, P2C airflow, 4-post Rail kit.
920-9N110-00R1-0
C0
MSN2201-CB2RC Nvidia Spectrum based 1GBase-T/100GbE 1U Open Ethernet switch
with Cumulus Linux, 48 RJ45 ports and 4 QSFP28 ports, Dual Power
Supply (AC), x86 CPU, short depth, C2P airflow, 4-post Rail-kit.

10
Part Number Legacy Part
Number
Marketing Description
920-9N110-00R1-0
N1
MSN2201-CB2RO Nvidia Spectrum based 1GBase-T/100GbE 1U Open Ethernet switch
with ONIE, 48 RJ45 ports and 4 QSFP28 ports, Dual Power Supply (AC),
x86 CPU, short depth, C2P airflow, 4-post Rail kit.

11
Introduction
NVIDIA Spectrum®based 1U switch systems are an ideal spine and Top of Rack (ToR) solution,
allowing maximum flexibility, with port speeds spanning from 10Gb/s to 100Gb/s per port, and port
density that enables full rack connectivity to any server at any speed. The uplink ports allow a
variety of blocking ratios that suit any application requirement. Powered by the NVIDIASpectrum
ASIC, the systems carry whopping switching and processing capacities in a compact 1U form factor.
Keeping with the NVIDIA tradition of setting performance record switch systems, the
NVIDIASpectrum-based systems introduce the world’s lowest latency for 100GbE switching and
routing elements, and do so while having the lowest power consumption in the market. They enable
the use of 10, 25, 40, 50 and 100GbE in a large scale without changing power infrastructure
facilities.
The NVIDIASpectrum-based 1U switch systems are a part of NVIDIA’s complete end-to-end solution,
which provides 10GbE through 100GbE interconnectivity within the data center. Other devices in this
solution include ConnectX®-4 based network interface cards, and LinkX®copper or fiber cabling/
transceivers. This end-to-end solution is topped with NEO, a management application that relieves
some of the major obstacles standing in the way when deploying a network. NEO enables a fully
certified and interoperable design, speeds up time to service and RoI. The systems introduce
hardware capabilities for multiple tunneling protocols that enable increased reachability and
scalability for today’s data centers. Implementing MPLS, NVGRE and VXLAN tunneling encapsulations
in the network layer of the data center allows more flexibility for terminating a tunnel by the
network, in addition to termination on the server endpoint.
While NVIDIA Spectrum provides the thrust and acceleration that powers the switch systems, they
get yet another angle of capabilities, running with a powerful x86-based processor, which allows
them to not only be the highest performing switch fabric elements, but also grants them the ability
to incorporate a Linux running server into the same device. This opens up multiple application
aspects of utilizing the high CPU processing power and the best switching fabric, to create a
powerful machine with unique appliance capabilities that can improve numerous network
implementation paradigms. The NVIDIA Spectrum-based 1U switch systems support the Open
Network Install Environment (ONIE) for zero touch installations of network operating systems. While
all Ethernet systems can be purchased preloaded with NVIDIA Onyx (MLNX-OS), the SN2000 switches
are offered with Cumulus Linux as well, and support SONiC (Software for Open Networking in the
Cloud) as an alternative operating system.
For a full list of all available ordering options, see .Ordering Information vAdding_SN2201.
Front View

12
SN2700
SN2740
SN2410
SN2100
SN2010
Rear View

13
SN2700 and SN2410
SN2740
SN2100
SN2010
SN2201
SN2201
Speed and Switching Capabilities
The table below describes maximum throughput and interface speed per system model.

14
System
Model
1GbT RJ45
Interfaces
1/10/25GbE SFP28
Interfaces*
40/50/100GbE QSFP28
Interfaces*
Max
Throughput
SN2700 32** 64
(using QSFP to SFP
splitter cables)
32 6.4Tb/s
SN2740 32** 64
(using QSFP to SFP
splitter cables)
32 6.4Tb/s
SN2410 48*+8** Total 64, 48SFP+16
(using QSFP to SFP
splitter cables)
8 4Tb/s
SN2100 16** 64
(using QSFP to SFP
splitter cables)
16
(or 32 50GbE interfaces
when using QSFP to
2xQSFP splitter cables)
3.2Tb/s
SN2010 18*+4** Total 34 - 18SFP+16
(using QSFP to SFP
splitter cables)
4
(or 8 50GbE interfaces
when using QSFP to
2xQSFP splitter cables)
1.7Tb/s
SN2201 48+4** 16
(using QSFP to SFP
splitter cables)
4
(or 8 50GbE interfaces
when using QSFP to
2xQSFP splitter cables)
448Gb/s
(*) Requiring a 1GBT SFP module
(**) Requiring a QSA adapter and a 1GBT SFP module
Management Interfaces, PSUs and Fans
The table below lists the various management interfaces, PSUs and fans per system model.
System
Model
USB MGT Console PSU Fan
SN2700 Rear Rear (2 ports) Rear 2 units 4 units
SN2740 Front Front (1 port) Front 2 units 4 units
SN2410 Rear Rear (2 ports) Rear 2 units 4 units
SN2100 Front (mini USB) Front (1 port) Front 2 units (non-
replaceable)
4 units (non-
replaceable)
SN2010 Front Front (1 port) Front 2 units (non-
replaceable)
4 units (non-
replaceable)

15
System
Model
USB MGT Console PSU Fan
SN2201 Front Front (1 port) Front 2 units 4 units
Features
For a full feature list, please refer to the system’s product brief. Go to https://www.nvidia.com/en-
us/networking/. In the main menu, click on Products > Ethernet Switch Systems, and select the
desired product page.
Certifications
The list of certifications (such as EMC, Safety and others) per system for different regions of the
world is located on the NVIDIA website athttp://www.mellanox.com/page/
environmental_compliance.

16
Installation
System Installation and Initialization
Installation and initialization of the system require attention to the normal mechanical, power, and
thermal precautions for rack-mounted equipment.
The installation procedure for the system involves the following phases:
Step Procedure See
1 Follow the safety warnings
Safety Warnings
2 Pay attention to the air flow consideration within
the system and rack
Air Flow
3 Make sure that none of the package contents is
missing or damaged
Package Contents
4 Mount the system into a rack enclosure 19" System Mounting Options
5 Power on the system
Initial Power On
6 Perform system bring-up System Bring-Up
7 [Optional] FRU replacements FRU Replacements
Safety Warnings
Prior to the installation, please review the Safety Warnings. Note that some warnings may not apply
to all models.
The rack mounting holes conform to the EIA-310 standard for 19-inch racks. Take
precautions to guarantee proper ventilation in order to maintain good airflow at ambient
temperature.
Unless otherwise specified, NVIDIA products are designed to work in an environmentally
controlled data center with low levels of gaseous and dust (particulate) contamination.
The operation environment should meet severity level G1 as per ISA 71.04 for gaseous
contamination and ISO 14644-1 class 8 for cleanliness level.

17
•
•
Air Flow
The systems are offered with two air flow patterns:
Power (rear) side inlet to connector side outlet - marked with blue power supplies/fans FRUs’
handles or blue dots that are placed on the power inlet side.
Air Flow Direction Marking - Power Side Inlet to Connector Side Outlet
Connector (front) side inlet to power side outlet - marked with red power supplies/fans FRUs’
handles or red dots that are placed on the power inlet side.
Air Flow Direction Marking - Connector Side Inlet to Power Side Outlet
The table below provides an air flow color legend and respective OPN designation.
•
•
The following information does not apply to SN2100/SN2010. In the SN2100/SN2010
systems, the fan units are non-replaceable.
The drawings are provided for illustration purposes only. The panel and modules
design may vary depending on the system.
All servers and systems in the same rack should be planned with the same airflow direction.
All FRU components need to have the same air flow direction. A mismatch in the air flow
will affect the heat dissipation.

18
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Direction Description and OPN Designation
Connector side inlet to power side outlet. The airflow direction is indicated
by red latches or by red dots that are placed on the power inlet side.
OPN designation is “-R”.
Power side inlet to connector side outlet. The airflow direction is indicated
by blue latches or by blue dots that are placed on the power inlet side.
OPN designation is “-F”.
Package Contents
Before installing your new system, unpack it and check against the parts list below that all the parts
have been sent. Check the parts for visible damage that may have occurred during shipping.
The SN2700 and SN2410 package content is as follows:
1 – System
1 – Rail kit
1 – Power cable for each power supply unit – Type C13-C14
1 – Cable retainer for each power supply unit
1 – DB9 to RJ-45 2m harness
1 - RJ-45 to RJ-452m harness
The SN2100/SN2010 package content is as follows:
1 – System
1 – Power cable for each power supply unit – Type C13-C14
1 – DB9 to RJ-45 2m harness
The SN2201 package content is as follows:
1 – System
1 – Rail kit
1 – Power cable for each power supply unit – Type C13-C14
1 – DB9 to RJ-45 2m harness
1 - RJ-45 to RJ-452m harness
A designated rail kit for the SN2100/SN2010 systems can be purchased separately.

19
•
•
•
•
•
System Mounting Options
The systems are shipped with the rail-kits specified in the following table:
System Model Rail Kit
SN2700
SN2700 Static Rail Kit
Optional:
SN2700 Telescopic Rail Kit
SN2410, SN2740 SN2740/SN2410 Static Rail Kit
SN2100, SN2010
The systems are shipped without a rail kit. A designated rail kit can
be purchased separately.
For installation instructions, see SN2100/SN2010 Side by Side
Mounting Rail Kit.
SN2201 SN2201 Tool-Less Rail Kit
SN2700 Static Rail Kit
Part Number Legacy Part Number Rack Size and Rack Depth Range
930-9BRKT-00JC-000 MTEF-KIT-A Short (17”-24”) or Standard (24”-34”)
The following parts are included in the static rail kit (see figure below):
2x Rack mount rails (A)
2x Rack mount brackets (B)
2x Rack mount blades (C)
8x M6 Standard cage nuts¹ ² and 8x M6 Standard pan-head Phillips screws¹ (D)
4x Phillips100 DEG F.H TYPE-I ST.ST 6-32 X 1/4 screws with a round patch (E)
¹ Other threads are available by special order: M5, 10-32, 12-24.² G-type cage-nut is available by
special order.
Rack Rail Kit Parts
If anything is damaged or missing, contact your sales representative at

20
•
•
•
Prerequisites:
Before mounting the system to the rack, select the way you wish to place the system. Pay attention
to the airflow within the rack cooling, connector and cabling options.
While planning how to place the system, consider the two installation options shown in the figure
below, and review the following points:
Make sure the system air flow is compatible with your installation selection. It is important to
keep the airflow within the rack in the same direction.
Note that the part of the system to which you choose to attach the rails (the front panel
direction, as demonstrated in Option 1 or the FRUs direction, as demonstrated in Option 2)
will determine the system’s adjustable side. The system’s part to which the brackets are
attached will be adjacent to the cabinet.
The FRU side is extractable. Mounting the rack brackets inverted to the FRU side (Option 2)
will allow you to slide the FRUs, in and out.
Installation Option 1 & Option 2
This manual suits for next models
6
Table of contents
Other Nvidia Switch manuals

Nvidia
Nvidia QM9700 User manual

Nvidia
Nvidia DU-07764-001 User manual

Nvidia
Nvidia Spectrum-4 SN5000 2U Instructions for use

Nvidia
Nvidia Mellanox SB7700 Instructions for use

Nvidia
Nvidia QM87 Series User manual

Nvidia
Nvidia P1453 User manual

Nvidia
Nvidia QM87 Series Installation instructions

Nvidia
Nvidia Spectrum-3 SN4000 Series Instructions for use

Nvidia
Nvidia TQ8 00 Series User manual

Nvidia
Nvidia Spectrum-2 SN3000 1U User manual