NVT Phybridge EC-LINK+ User manual

MADE IN CANADA
Long Reach PoE over Coax
Fast Ethernet and PoE++ (Up to 50W) over Coax
UPC: 735890500162PN: NV-ECLK-PLS
EC-Link+(NV-ECLK-PLS)
• Paired with CLEER24, EC10 or EC-Base
• Up to 50W PoE on 4-pairs
• Local power option
• IEEE compliant
EC-Link+Quick Install Guide
1. Remove the EC-Link+ from its packaging.
2. Must ensure cable is properly terminated before connecting any EC product.
3. Remove all legacy equipment from the Coax cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are
not connected when you connect the EC-Link+.
4. Connect the Network Infrastructure cable from the CLEER24 switch, EC10 switch, or
EC-Base to the EC-Link+ (LRE side).
5. Using CAT5 or higher category cable, connect the endpoint to EC-Link+ (Endpoint side).
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright 2019 NVT Phybridge
445-0022-A
The EC-Link+ Adapter enables extended Ethernet and PoE reach beyond traditional
distances using Coax infrastructure. When paired with the CLEER24 Switch, EC10 Switch or
EC-Base Extender, the Adapter delivers 10/100 Mbps, symmetrical full duplex. The EC
offering is designed specifically to enable easy deployment over Coax for reaches beyond
that of standard Ethernet eliminating the costs and disruption associated with IDF closet
requirements.
EC-Link+ Adapter Applications
NV-ECLK-BSE*
Standard PoE Switch
NV-CLR-024/NV-EC-10
Local Power Option
Coax Cable
up to 6,000ft (1,830m)
To Application
3 51 9 11715 1713 21 2319 27 2925 33 3531 39 4137 45 4743
4 62 10 12816 1814 22 2420 28 3026 34 36
SFP+1
SFP+2
SFP1
SFP2
32 40 4238 46 4844
10/100 Mbps (full duplex, symmetrical) & PoE+ over Coax with up to 6,000ft (1,830m) reach.
13 5 7
24 6 8
17 19 21 23
18 20 22 24
911 13 15
10 12 14 16
24
23
2221
20191817
16
15
1413
12
11
10987
6
5
43
2
1
RUN
ALARM
FAULT
Reset
GBE2
GBE1
1357
2 4 6 8
9
10
POWER
IP ENDPOINT
EC-Base
Long Reach PoE over Coax
C
NV-ECLK-PLS
EC-LINK+
EC-Link+
Long Reach PoE over Coax
Local Power Option
Coax Cable
up to 6,000ft (1,830m)
IP ENDPOINT
NV-ECLK-PLS
EC-Link+
Long Reach PoE over Coax
EC-Link+
Long Reach PoE over Coax To Endpoint
To LRE
37-55V
DC IN
Link/Speed
Green:
100Mbps
Orange:
10Mbps
DC IN
SPD
100 GR 10 OR
TO LRE 37-55V Link Activity
TO ENDPOINT ACTLNK
*Base Extender can be powered locally for use with non-PoE switches.
EC-Link+
Long Reach PoE over Coax
EC-Link+
Long Reach PoE over Coax

Note the following:
All of the above instructions provide basic installation information necessary for the proper
and safe functioning of this equipment. Persons installing or maintaining this product must
read all of the safety instructions and the parts of system grounding, which are applicable
to the system being maintained. Only trained, qualified service personnel shall install or
maintain this product.
Compliance and Environmental Information
All the compliance and environmental information is available on our website
www.nvtphybridge.com
• Refer to the CLEER24 or EC10 Quick Install Guides under “Safety Warnings” for the EC adapters
• Reportez-vous aux Quick Install Guides CLEER24 ou EC10 sous “Safety Warnings” pour les adaptateurs EC
• Beachten Sie die CLEER24- oder EC10- Quick Install Guides unter “Safety Warnings” für die EC-Adapter
• Consulte las Quick Install Guides CLEER24 o EC10 bajo “Safety Warnings” para los adaptadores EC
• Katso CLEER24- tai EC10 Quick Install Guides EC-sovittimien “Safety Warnings” alla
• Raadpleeg de CLEER24 of EC10 Quick Install Guides onder “Safety Warnings” voor de EC-adapter
• Se CLEER24 eller EC10 Quick Install Guides under “Safety Warnings” för EC-adaptrarna
• Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere
• Ανατρέξτε στους οδηγούς CLEER24 ή EC10 Quick Install Guides στην ενότητα “Safety Warnings” για τους προσαρμογείς EC
• Fare riferimento alla sezione CLEER24 o EC10 Quick Install Guides sotto “Safety Warnings” per gli adattatori EC
• Consulte o CLEER24 ou EC10 Quick Install Guides em “Safety Warnings” para os adaptadores EC
• Irreferi għall-CLEER24 jew EC10 Quick Install Guides taħt “Safety Warnings” għall-adapters EC
• Vaadake CLEER24 või EC10 Quick Install Guides alusel “Safety Warnings” EC adapterid
• A EC adapterek “Safety Warnings” című részében olvassa el a CLEER24 vagy a EC10 Quick Install Guides című részt
• Nanašajo na CLEER24 ali EC10 Quick Install Guides pod "Safety Warnings" za EC adapterji
• Další informace naleznete v příručkách CLEER24 nebo EC10 Quick Install Guides v části "Safety Warnings" pro adaptéry EC
• Kreiptis į CLEER24 ar EC10 Quick Install Guides pagal "Safety Warnings" Už EC adapteriai
• Skatiet CLEER24 vai EC10 Quick Install Guides zem "Safety Warnings,” lai EC adapteri
• Pozrite si CLEER24 alebo EC10 Quick Install Guides v časti "Safety Warnings" pre adaptéry EC
• Sjá CLEER24 eða EC10 Quick Install Guides undir "Safety Warnings " fyrir EC-millistykki
• Zobacz CLEER24 lub EC10 Quick Install Guides w sekcji "Safety Warnings" w przypadku adapterów EC
• Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere
• Consultați ghidurile CLEER24 sau EC10 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele EC
• Обърнете се към CLEER24 или EC10 Quick Install Guides в "Safety Warnings" за адаптери EC
• Keep these instructions with the equipment.
• Do not attempt to install or service this equipment unless you are skilled in the installation
and maintenance of electronic telecommunications equipment and have successfully
completed specific training for this equipment.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION
AND/OR RISK OF ELECTRICAL SHOCK.
WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER
EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION,
AND/OR EQUIPMENT DAMAGE.
Safety Warnings and Precautions
Technical Specifications
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Technical Support
The NVT Phybridge Technical Support Group is available to assist you with product
installation, configuration, monitoring and troubleshooting procedures. Should you
experience trouble with this equipment or for repair or warranty information, please
contact NVT Phybridge at www.nvtphybridge.com/support/ or directly through email at
Warranty: The EC adapters are backed by NVT Phybridge’s award-winning customer
support and 5-year warranty.
Support and Warranty
PoE Power Available from EC-Link+
Copyright 2019 NVT Phybridge
445-0022-A
EC-Link+
• CAUTION, Hot surface
• ATTENTION, Surface chaude
• VORSICHT, Heiße Oberfläche
• PRECAUCIÓN, Superficie caliente
• VAROITUS, Kuuma pinta
• VOORZICHTIGHEID, Heet oppervlakte
• VARNING, Varm yta
• ADVARSEL, Varm overflade
• ΠΡΟΣΟΧΗ, Καυτή επιφάνεια
• ATTENZIONE, Superficie calda
• CUIDADO, Superfície quente
• ATTENZJONI, Wiċċ sħun
• ETTEVAATUST, Kuum pind
• VIGYÁZAT, Forró felület
• PREVIDNOST, Vroča površina
• POZOR, Horký povrch
• ATSARGIAI, Karštas paviršius
• UZMANĪBU, Karstā virsma
• POZOR, Horúci povrch
• VARÚÐ, Heitt yfirborð
• PRZESTROGA, Gorąca powierzchnia
• FORSIKTIG, Varm overflate
• PRUDENȚĂ, Suprafata fierbinte
Model EC-Link+
Part Number NV-ECLK-PLS
Dimensions 10.09cm x 5.03cm x 2.57cm (LxWxH);
3.97” x 1.98” x 1.01” (LxWxH)
Weight 108g (3.81oz.)
Interface: Network
Infrastructure side
(CLEER)
1 BNC port: Coax cable (RG59, RG6, RG11)
Interface: IEEE Side (IP
Device)
1 RJ45 port; adapter is IEEE 802.3af/at
compliant and will negotiate power
requirements with IP end device.
Power Supply
Maximum 50W when powered from EC-
Base or local power supply. Maximum
30W when powered from CLEER24 or
EC10.
DC IN
Optional (sold separately)
48V – 56VDC via an external AC/DC Power
Adapter (IEC Class II isolated only) with barrel
connector
NOTE 1: Local power supply used must have its
output isolated from Earth potential.
NOTE 2: If voltage of local power supply is
lower than the power voltage provided from
the PoE switch, then power on the PoE switch
should be turned off.
Power
Consumption 1.1W
Operating
temperature
-40°C to +70°C (-40°F to +158°F)
Tests conducted against international safety
standard at maximum ambient temperatures
of 60ºC at 30W and 55ºC at 50W
Mean Time
Before Failure
(MTBF)
20+ years
Humidity 10% to 95% (non-condensing) at 35° C
RG59 RG6 RG11
EC-Link+
100Mbit 10Mbit 100Mbit 10Mbit 100Mbit 10Mbit
1,500ft
(475m)
6,000ft
(1,830m)
2,000ft
(610m)
6,000ft
(1,830m)
3,000ft
(915m)
6,000ft
(1,830m)
19W 0W 24W 8W 28W 24W
This manual suits for next models
2
Table of contents
Other NVT Phybridge Adapter manuals

NVT Phybridge
NVT Phybridge EC4 User manual

NVT Phybridge
NVT Phybridge FLEX-C User manual

NVT Phybridge
NVT Phybridge EC-Link User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-Base User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual