The FLEX-Link and FLEX-C adapters enable extended Ethernet and PoE reach
beyond traditional distances using 1, 2 or 4 pair UTP infrastructure. The
adapters, when used with the FLEX Switch or FLEX-Base, deliver 10/100Mbps
(symmetrical, full duplex) and PoE (up to 50W) over 1- (needs local power), 2-,
or 4-pair UTP/STP with up to 2,000ft (610m) reach The FLEX offering is
designed specifically to enable easy deployment over UTP for reaches beyond
that of standard Ethernet eliminating the costs and disruption associated with
IDF closet requirements.
FLEX Adapter Applications
2 or 4 pair UTP
2 or 4 pair UTP
2 or 4 pair UTP
To Application
To Switch Local Power Option
Local Power Option
Local Power Option
Local Power Option
Local Power Option
10/100 Mbps (full duplex, symmetrical) & PoE++ over multi-pair UTP with 2,000ft (610M) reach.
NOTE: FLEX-Link max. power 50W over 4 pairs and FLEX-C maximum power 30W over 2 pairs
FLEX-C Installation Details
1. Remove the FLEX-C from its packaging.
2. Remove all legacy equipment from the UTP cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are
not connected when you connect the FLEX-C.
3. Connect the Network Infrastructure cable from the FLEX24 switch or
FLEX-Base to the FLEX-C (FLEX side).
4. Using CAT5 or higher category cable, connect the endpoint to FLEX-C
(Device side).
NOTE: FLEX-C can be used with FLEX24 switch or FLEX-Base
Product Details (NV-FLXLK-C)
• Paired with FLEX24, FLEX8 or FLEX-Base
• Up to 30W PoE
• PoE on spare pairs
• Supports IEEE compliant devices
FLEX-Link Installation Details
1. Remove the FLEX-Link from its packaging.
2. Remove all legacy equipment from the UTP cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are
not connected when you connect the FLEX-Link.
3. Connect the Network Infrastructure cable from the FLEX24 switch or
FLEX-Base to the FLEX-Link (FLEX side).
4. Using CAT5 or higher category cable, connect the endpoint to the FLEX-Link
(Endpoint side).
NOTE: FLEX-Link can be used with FLEX24 switch or FLEX-Base
Product Details (NV-FLXLK)
• Paired with FLEX24, FLEX8 or FLEX-Base
• Up to 50W PoE
• PoE on 4 pairs
• Local power option
• IEEE compliant
FLEX-Base
To Switch To Adapter
Installation Details
1. Remove the FLEX-Base from its packaging.
2. Remove all legacy equipment from the UTP cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are
not connected when you connect the FLEX-Base.
3. Connect FLEX-Base (Switch side) to downlink port on switch.
4. Connect the Network Infrastructure cable from the FLEX-Base (Adapter side) to
FLEX-Link or FLEX-C (FLEX side).
5. Using CAT5 or higher category cable, connect the endpoint to the FLEX-Link
or FLEX-C (Endpoint/Device side).
NOTE: FLEX-Base can be used with FLEX-Link or FLEX-C
Product Details (NV-FLXLK-Base)
• Paired with FLEX-Link or FLEX4
• Up to 50W PoE
QUICK INSTALL GUIDE - FLEX ADAPTERS
Copyright 2018 NVT Phybridge | 413-0003-A | Page 1888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com
1 RJ45 port: UTP cable (2-pair or 4-pair)
To FLEX To Endpoint
Activity
Link
Activity
• Local power option
• IEEE compliant
To FLEX To Device
Activity
Link/ Speed
Green:
100Mbps
Orange:
10Mbps ActivityLink
To FLEX To Device
To Switch To Adapter
Link/ Speed
Green:
100Mbps
Orange:
10Mbps
Link/ Speed
Green:
100Mbps
Orange:
10Mbps
37-55V DC In
37-55V DC In
The FLEX adapters are
extremely simple to use with
no IP or MAC address
configuration required.
Status LEDs indicate power
and link connectivity/activity
for RJ45 ports.
NOTE: Please see page 2 for
Safety Warnings and Precautions
Cable Type Data Rate Reach
4 pair CAT5e 100Mbps 2,000ft / 610m
2 pair CAT5e 100Mbps
10Mbps
1,000ft / 300m
2,000ft / 610m
1 pair CAT5e 100Mbps
10Mbps
1,000ft / 300m
2,000ft / 610m
(adapter must be locally
powered)

QUICK INSTALL GUIDE
Copyright 2018 NVT Phybridge | 413-0003-A | Page 2888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com
Compliance and Environmental Information
All the compliance and environmental information is available on our website www.nvtphybridge.com
The NVT Phybridge Technical Support Group is available to assist you with product installation, configuration, monitoring and troubleshooting procedures. Should you
experience trouble with this equipment or for repair or warranty information, please contact NVT Phybridge at +1 905.901.3633 or [email protected].
Technical Support
Warranty: The FLEX adapters are backed by NVT Phybridge’s award-winning customer support and 5-year warranty.
FLEX-Link and FLEX-Base
CAUTION, Hot surface
ATTENTION, Surface chaude
VORSICHT, Heiße Oberfläche
PRECAUCIÓN, Superficie caliente
VAROITUS, Kuuma pinta
VOORZICHTIGHEID, Heet oppervlakte
VARNING, Varm yta
ADVARSEL, Varm overade
ΠΡΟΣΟΧΗ, Καυτή επιφάνεια
ATTENZIONE, Superficie calda
CUIDADO, Superfície quente
ATTENZJONI, Wiċċ sħun
ETTEVAATUST, Kuum pind
VIGYÁZAT, Forró felület
PREVIDNOST, Vroča površina
POZOR, Horký povrch
ATSARGIAI, Karštas paviršius
UZMANĪBU, Karstā virsma
POZOR, Horúci povrch
VARÚÐ, Heitt yfirborð
PRZESTROGA, Gorąca powierzchnia
FORSIKTIG, Varm overflate
PRUDENȚĂ,Suprafata fierbinte
ВНИМАНИЕ, Гореща повърхност
Refer to the FLEX24 or FLEX8 Quick Install Guides under “Safety Warnings” for the FLEX adapters
Reportez-vous aux Quick Install Guides FLEX24 ou FLEX8 sous "Safety Warnings" pour les adaptateurs FLEX
Beachten Sie die FLEX24- oder FLEX8- Quick Install Guides unter "Safety Warnings” für die FLEX-Adapter
Consulte las Quick Install Guides FLEX24 o FLEX8 bajo "Safety Warnings" para los adaptadores FLEX
Katso FLEX24- tai FLEX8 Quick Install Guides FLEX-sovittimien "Safety Warnings" alla
Raadpleeg de FLEX24 of FLEX8 Quick Install Guides onder "Safety Warnings" voor de FLEX-adapters
Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" för FLEX-adaptrarna
Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
Ανατρέξτε στους οδηγούς FLEX24 ήFLEX8 Quick Install Guides στην ενότητα "Safety Warnings" για τους προσαρμογείς FLEX
Fare riferimento alla sezione FLEX24 o FLEX8 Quick Install Guides sotto "Safety Warnings" per gli adattatori FLEX
Consulte o FLEX24 ou FLEX8 Quick Install Guides em "Safety Warnings" para os adaptadores FLEX
Irreferi għall-FLEX24 jew FLEX8 Quick Install Guides taħt "Safety Warnings" għall-adapters FLEX
Vaadake FLEX24 või FLEX8 Quick Install Guides alusel "Safety Warnings" FLEX adapterid
A FLEX adapterek "Safety Warnings" című részében olvassa el a FLEX24 vagy a FLEX8 Quick Install Guides című részt
Nanašajo na FLEX24 ali FLEX8 Quick Install Guides pod "Safety Warnings" za FLEX adapterji
Další informace naleznete v příručkách FLEX24 nebo FLEX8 Quick Install Guides v části "Safety Warnings" pro adaptéry FLEX
Kreiptis į FLEX24 ar FLEX8 Quick Install Guides pagal "Safety Warnings" Už FLEX adapteriai
Skatiet FLEX24 vai FLEX8 Quick Install Guides zem "Safety Warnings", lai FLEX adapteri
Pozrite si FLEX24 alebo FLEX8 Quick Install Guides v časti "Safety Warnings" pre adaptéry FLEX
Sjá FLEX24 eða FLEX8 Quick Install Guides undir "Safety Warnings" fyrir FLEX-millistykki
Zobacz FLEX24 lub FLEX8 Quick Install Guides w sekcji "Safety Warnings" w przypadku adapterów FLEX
Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
Consultați ghidurile FLEX24 sau FLEX8 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele FLEX
Обърнете се към FLEX24 или FLEX8 Quick Install Guides в"Safety Warnings" за адаптери FLEX
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Safety Warnings and Precautions
All of the above instructions provide basic installation information necessary for the proper and safe functioning of this equipment. Persons installing or
maintaining this product must read all of the safety instructions and the parts of system grounding, which are applicable to the system being maintained.
Only trained, qualified service personnel shall install or maintain this product.
Note the following:
• Keep these instructions with the equipment.
• Do not attempt to install or service this equipment unless you are skilled in the installation and maintenance of electronic telecommunications equipment and have
successfully completed specific training for this equipment.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR RISK OF ELECTRICAL SHOCK.
WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER EXPOSED PLANT APPLICATION MAY
RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.
Technical Specifications
Model Number FLEX-C FLEX-Link FLEX-Base
Part Number NV-FLXLK-C NV-FLXLK NV-FLXLK-BSE
Dimensions (L x W x H) 3.19” x 1.50” x 0.90” (8.1cm x 3.8cm x 2.3cm) 3.46” x 2.16” x 0.98” (8.8cm x 5.5cm x 2.5cm) 3.46” x 2.16” x 0.98” (8.8cm x 5.5cm x 2.5cm)
Weight 1.5oz (44g) 4oz (114g) 14oz (114g)
Interface: Network Infrastructure side (FLEX) 1 RJ45 port: UTP/STP cable (2-pair or 4-pair) 1 RJ45 port: UTP/STP cable (2-pair or 4-pair) 1 RJ45 port: UTP/STP cable (2-pair or 4-pair)
Interface: IEEE Side (IP Device)
1 RJ45 port; device must be IEEE 802.3 af/at compliant 1 RJ45 port; device must be IEEE 802.3 af/at compliant
50W, 10/100Mbps connection to IP end device
(For General/PoE Switch)
1 RJ45 port: supports negotiation with IEEE 802.3 af/at
switches
Power Supply
PoE from the FLEX24 or FLEX8 switches or local power
from FLEX-Base, maximum 30W
(over 2-pairs)
PoE from the FLEX24 or FLEX8 switches or external
power supply; maximum 50W (over 4-pairs) or 30W
(over 2-pairs)
PoE from standard PoE switch, or external power
supply; maximum 50W (over 4=pairs) or 30W (over 2-
pairs)
DC IN
(Barrel Connector)
Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter
(IEC Class II isolated only)
NOTE 1: Local power supply used must have its output
isolated from Earth potential.
NOTE 2: If voltage of local power supply is lower than
the power voltage provided from the PoE switch, then
power on the PoE switch should be turned off.
Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter
(IEC Class II isolated only)
NOTE: local power supply must have its output
isolated from Earth potential.
Power Consumption 1.3W 1.5W 1.5W
Operating Temperature -40°F to 158°F (-40ºC to 70ºC)
Tests conducted against
international safety standard at maximum ambient temperatures
of 140°F (60ºC) at 15W and 122°F (50ºC) at 30W
40°F to 158°F (-40ºC to 70ºC)
Tests conducted against
international safety standard at maximum ambient temperatures
of 140°F (60ºC) at 15W and 122°F (50ºC) at 30W
40°F to 158°F (-40ºC to 70ºC)
Tests conducted against
international safety standard at maximum ambient temperatures
of 140°F (60ºC) at 15W and 122°F (50ºC) at 30W
Humidity 10% to 95% (non-condensing) at 95°F (35° C) 10% to 95% (non-condensing) at 95°F (35° C) 10% to 95% (non-condensing) at 95°F (35° C)
This manual suits for next models
1
Other NVT Phybridge Adapter manuals

NVT Phybridge
NVT Phybridge EC4 User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual

NVT Phybridge
NVT Phybridge EC-Link User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-C User manual

NVT Phybridge
NVT Phybridge FLEX-Base User manual

NVT Phybridge
NVT Phybridge EC-LINK+ User manual