NVT Phybridge EC4 User manual

EC4 (NV-EC-04)
• Paired with CLEER24, EC10 or EC-Base
• 1 uplink port and 4 downlink ports
• Up to 50W PoE per downlink port
• Local power option
The EC4 Adapter enables extended Ethernet and PoE reach beyond traditional distances
using coax infrastructure. When paired with the CLEER24 Switch, EC10 Switch or EC-Base
Extender, the Adapter delivers 100Mbps, symmetrical full duplex. The EC offering is
designed specifically to enable easy deployment over coax for reaches beyond that of
standard Ethernet eliminating the costs and disruption associated with IDF closet
requirements.
NV-ECLK-BSE*
NV-EC-04
Standard PoE Switch
NV-CLR-024/NV-EC-10
Local Power Option
Coax Cable
up to 3,000ft (915m)
Coax Cable
up to 3,000ft (915m)
To Application
3 51 9 11715 1713 21 2319 27 2925 33 3531 39 4137 45 4743
4 62 10 12816 1814 22 2420 28 3026 34 36
SFP+1
SFP+2
SFP1
SFP2
32 40 4238 46 4844
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
100 Mbps (full duplex, symmetrical) & PoE++ over Coax with 3,000ft (915m) reach.
EC4 Adapter Applications
Technical Specifications
13 5 7
24 6 8
17 19 21 23
18 20 22 24
911 13 15
10 12 14 16
24
23
2221
20191817
16
15
1413
12
11
10987
6
5
43
2
1
RUN
ALARM
FAULT
Reset
GBE2
GBE1
1357
2 4 6 8
9
10
POWER
NV-EC-04
Local Power Option
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
EC-Base
Long Reach PoE over Coax
MADE IN CANADA
UPC: 735890500070
PN: NV-EC-04
EC4
Long Reach PoE over Coax
Fast Ethernet and PoE++ (Up to 50W)
over Coax
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright 2019 NVT Phybridge
445-0024-A
*Base Extender can be powered locally for use with non-PoE switches.
Model EC4
Part Number NV-EC-04
Dimensions •11cm x 7cm x 2.5cm (LxWxH);
•4.3” x 2.75” x 0.98” (LxWxH)
Weight 96g (3.38oz.)
Interface: Network
Infrastructure side
(CLEER)
1 BNC port: Coax cable (RG59, RG6,
RG11)
Interface: IEEE Side (IP
Device)
4 RJ45 ports: devices must be IEEE 802.3
af/at compliant
Power Supply
PoE from the CLEER / EC switch, or
external power supply; maximum 50W
(over 4-pairs) each port
DC IN
Optional (sold separately)
48V – 56VDC via an external AC/DC Power
Adapter (IEC Class II isolated only) with barrel
connector
NOTE 1: Local power supply used must have
its output isolated from Earth potential.
NOTE 2: If voltage of local power supply is
lower than the power voltage provided from
the PoE switch, then power on the PoE switch
should be turned off.
Power
Consumption 1W
Operating
temperature
-40°C to +70°C (-40°F to +158°F)
Tests conducted against international safety
standard at maximum ambient temperatures of
50ºC
Mean Time
Before Failure
(MTBF)
20+ years
Humidity 10% to 95% (non-condensing) at 35° C

Note the following:
All of the above instructions provide basic installation information necessary for the proper and
safe functioning of this equipment. Persons installing or maintaining this product must read all of
the safety instructions and the parts of system grounding, which are applicable to the system
being maintained. Only trained, qualified service personnel shall install or maintain this product.
• Keep these instructions with the equipment.
• Do not attempt to install or service this equipment unless you are skilled in the installation and
maintenance of electronic telecommunications equipment and have successfully completed
specific training for this equipment.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR
RISK OF ELECTRICAL SHOCK.
WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER
EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR
EQUIPMENT DAMAGE.
Safety Warnings and Precautions
Compliance and Environmental Information
All the compliance and environmental information is available on our website
www.nvtphybridge.com
Support and Warranty
Technical Support
The NVT Phybridge Technical Support Group is available to assist you with product installation,
configuration, monitoring and troubleshooting procedures. Should you experience trouble with
this equipment or for repair or warranty information, please contact NVT Phybridge at
Warranty: The EC adapters are backed by NVT Phybridge’s award-winning customer support
and 5-year warranty.
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
• Refer to the CLEER24 or EC10 Quick Install Guides under “Safety Warnings” for the EC adapters
• Reportez-vous aux Quick Install Guides CLEER24 ou EC10 sous “Safety Warnings” pour les adaptateurs EC
• Beachten Sie die CLEER24- oder EC10- Quick Install Guides unter “Safety Warnings” für die EC-Adapter
• Consulte las Quick Install Guides CLEER24 o EC10 bajo “Safety Warnings” para los adaptadores EC
• Katso CLEER24- tai EC10 Quick Install Guides EC-sovittimien “Safety Warnings” alla
• Raadpleeg de CLEER24 of EC10 Quick Install Guides onder “Safety Warnings” voor de EC-adapter
• Se CLEER24 eller EC10 Quick Install Guides under “Safety Warnings” för EC-adaptrarna
• Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere
• Ανατρέξτε στους οδηγούς CLEER24 ή EC10 Quick Install Guides στην ενότητα “Safety Warnings” για τους προσαρμογείς EC
• Fare riferimento alla sezione CLEER24 o EC10 Quick Install Guides sotto “Safety Warnings” per gli adattatori EC
• Consulte o CLEER24 ou EC10 Quick Install Guides em “Safety Warnings” para os adaptadores EC
• Irreferi għall-CLEER24 jew EC10 Quick Install Guides taħt “Safety Warnings” għall-adapters EC
• Vaadake CLEER24 või EC10 Quick Install Guides alusel “Safety Warnings” EC adapterid
• A EC adapterek “Safety Warnings” című részében olvassa el a CLEER24 vagy a EC10 Quick Install Guides című részt
• Nanašajo na CLEER24 ali EC10 Quick Install Guides pod "Safety Warnings" za EC adapterji
• Další informace naleznete v příručkách CLEER24 nebo EC10 Quick Install Guides v části "Safety Warnings" pro adaptéry EC
• Kreiptis į CLEER24 ar EC10 Quick Install Guides pagal "Safety Warnings" Už EC adapteriai
• Skatiet CLEER24 vai EC10 Quick Install Guides zem "Safety Warnings,” lai EC adapteri
• Pozrite si CLEER24 alebo EC10 Quick Install Guides v časti "Safety Warnings" pre adaptéry EC
• Sjá CLEER24 eða EC10 Quick Install Guides undir "Safety Warnings " fyrir EC-millistykki
• Zobacz CLEER24 lub EC10 Quick Install Guides w sekcji "Safety Warnings" w przypadku adapterów EC
• Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere
• Consultați ghidurile CLEER24 sau EC10 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele EC
• Обърнете се към CLEER24 или EC10 Quick Install Guides в "Safety Warnings" за адаптери EC
PoE Power Available to EC4
EC4 Quick Install Guide
1. Remove the EC4 from its packaging.
2. Must ensure cable is properly terminated before connecting any EC product.
3. Remove all legacy equipment from the Coax cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are not
connected when you connect the EC4.
4. Connect the Network Infrastructure cable from the CLEER24 switch, EC10 switch, or EC-Base to
the EC4 (LRE side).
5. Using CAT5 or higher category cable, connect the endpoint to EC4 (Endpoint side).
Endpoint device must be IEEE 802.3 af/at compliant.
To Endpoints
To Switch
Link/Speed
Green:
100Mbps
Solid =Link
Flashing = Activity
RIGHT (Green)
100Mbps
Solid = Link
Flashing = Activity
LEFT (Orange)
10Mbps
Solid = Link
Flashing = Activity
Copyright 2019 NVT Phybridge
445-0024-A
RG59 RG6 RG11
EC4
100Mbit 100Mbit 100Mbit
1,500ft (475m) 2,000ft (610m) 3,000ft (915m)
19W 24W 28W
This manual suits for next models
1
Table of contents
Other NVT Phybridge Adapter manuals

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-C User manual

NVT Phybridge
NVT Phybridge EC-LINK+ User manual

NVT Phybridge
NVT Phybridge FLEX-Base User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual

NVT Phybridge
NVT Phybridge EC-Link User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual