NVT Phybridge FLEX-Link User manual

FLEX-Link (NV-FLXLK)
• Paired with FLEX24, FLEX8 or FLEX-Base
• Up to 50W PoE
• PoE mode A, mode B and 4-pair mode
• Local power option
• IEEE compliant
FLEX-Link Adapter Applications
10/100Mbps (full duplex, symmetrical) & PoE++ over multi-pair UTP with 2,000ft (610M) reach.
NV-FLXLK-BSE*NV-FLXLK
NV-FLXLK
Standard PoE Switch
NV-FLX-024/NV-FLX-08
Local Power Option
Local Power Option
Multi-Pair UTP Cable
up to 2,000ft (610m)
Multi-Pair UTP Cable
up to 2,000ft (610m)
To Application
1 2 3 4 5 6 7 8
WE
3519117151713212319272925333531394137454743
462101281618142224202830263436
SFP+1
SFP+2
SFP1
SFP2
32404238464844
Reset
24222018161412108642
2321191715131197531
RUN
ALARM
FAULT
FLEX-Link
Long Reach PoE over UTP
IP ENDPOINT
IP ENDPOINT
FLEX-Link
Long Reach PoE over UTP
FLEX-Base
Long Reach PoE over UTP
FLEX-Link Quick Install Guide
The FLEX-Link adapter enables extended Ethernet and PoE reach beyond traditional
distances using 1, 2 or 4 pair UTP infrastructure. When paired with the FLEX24 Switch, FLEX8
Switch or FLEX-Base Extender, the adapter delivers 10/100Mbps, symmetrical full duplex.
The FLEX offering is designed specifically to enable easy deployment over Multi-Pair UTP for
reaches beyond that of standard Ethernet eliminating the costs and disruption associated
with IDF closet requirements.
TO ENDPOINT
ACTLNK
Link Activity
TO LRE
37-55V
DC IN
ACTLNK/SPD
Activity
37-55V
DC IN
Link/Speed
Green:
100Mbps
Orange:
10Mbps
To Endpoint
To LRE
(Long Reach Ethernet)
FLEX-Link
Long Reach PoE over UTP
1. Remove the FLEX-Link from its packaging.
2. Must ensure cable is properly terminated before connecting any FLEX product.
3. Remove all legacy equipment from the UTP cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are not
connected when you connect the FLEX-Link.
4. Connect the Network Infrastructure cable from the FLEX24 switch, FLEX8 switch or
FLEX-Base to the FLEX-Link (LRE side).
5. Using CAT5 or higher category cable, connect the endpoint to the FLEX-Link (Endpoint
side).
NOTE: FLEX-Link can be used with FLEX24 switch, FLEX8 switch or FLEX-Base
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright 2019 NVT Phybridge
445-0020-A
FLEX-Link
Long Reach PoE over UTP
*Base Extender can be powered locally for use with non-PoE switches.

Note the following:
All of the above instructions provide basic installation information necessary for the proper
and safe functioning of this equipment. Persons installing or maintaining this product must
read all of the safety instructions and the parts of system grounding, which are applicable
to the system being maintained. Only trained, qualified service personnel shall install or
maintain this product.
Compliance and Environmental Information
All the compliance and environmental information is available on our website
www.nvtphybridge.com
• Refer to the FLEX24 or FLEX8 Quick Install Guides under “Safety Warnings” for the FLEX adapters
• Reportez-vous aux Quick Install Guides FLEX24 ou FLEX8 sous "Safety Warnings" pour les adaptateurs FLEX
• Beachten Sie die FLEX24- oder FLEX8- Quick Install Guides unter "Safety Warnings” für die FLEX-Adapter
• Consulte las Quick Install Guides FLEX24 o FLEX8 bajo "Safety Warnings" para los adaptadores FLEX
• Katso FLEX24- tai FLEX8 Quick Install Guides FLEX-sovittimien "Safety Warnings" alla
• Raadpleeg de FLEX24 of FLEX8 Quick Install Guides onder "Safety Warnings" voor de FLEX-adapters
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" för FLEX-adaptrarna
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
• Ανατρέξτε στους οδηγούς FLEX24 ή FLEX8 Quick Install Guides στην ενότητα "Safety Warnings" για τους προσαρμογείς
FLEX
• Fare riferimento alla sezione FLEX24 o FLEX8 Quick Install Guides sotto "Safety Warnings" per gli adattatori FLEX
• Consulte o FLEX24 ou FLEX8 Quick Install Guides em "Safety Warnings" para os adaptadores FLEX
• Irreferi għall-FLEX24 jew FLEX8 Quick Install Guides taħt "Safety Warnings" għall-adapters FLEX
• Vaadake FLEX24 või FLEX8 Quick Install Guides alusel "Safety Warnings" FLEX adapterid
• A FLEX adapterek "Safety Warnings" című részében olvassa el a FLEX24 vagy a FLEX8 Quick Install Guides című részt
• Nanašajo na FLEX24 ali FLEX8 Quick Install Guides pod "Safety Warnings" za FLEX adapterji
• Další informace naleznete v příručkách FLEX24 nebo FLEX8 Quick Install Guides v části "Safety Warnings" pro adaptéry FLEX
• Kreiptis į FLEX24 ar FLEX8 Quick Install Guides pagal "Safety Warnings" Už FLEX adapteriai
• Skatiet FLEX24 vai FLEX8 Quick Install Guides zem "Safety Warnings", lai FLEX adapteri
• Pozrite si FLEX24 alebo FLEX8 Quick Install Guides v časti "Safety Warnings" pre adaptéry FLEX
• Sjá FLEX24 eða FLEX8 Quick Install Guides undir "Safety Warnings" fyrir FLEX-millistykki
• Zobacz FLEX24 lub FLEX8 Quick Install Guides w sekcji "Safety Warnings" w przypadku adapterów FLEX
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
• Consultați ghidurile FLEX24 sau FLEX8 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele FLEX
• Обърнете се към FLEX24 или FLEX8 Quick Install Guides в "Safety Warnings" за адаптери FLEX
• Keep these instructions with the equipment.
• Do not attempt to install or service this equipment unless you are skilled in the installation
and maintenance of electronic telecommunications equipment and have successfully
completed specific training for this equipment.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION
AND/OR RISK OF ELECTRICAL SHOCK.
WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER
EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION,
AND/OR EQUIPMENT DAMAGE.
Safety Warnings and Precautions
FLEX-Link
• CAUTION, Hot surface
• ATTENTION, Surface chaude
• VORSICHT, Heiße Oberfläche
• PRECAUCIÓN, Superficie caliente
• VAROITUS, Kuuma pinta
• VOORZICHTIGHEID, Heet oppervlakte
• VARNING, Varm yta
• ADVARSEL, Varm overflade
• ΠΡΟΣΟΧΗ, Καυτή επιφάνεια
• ATTENZIONE, Superficie calda
• CUIDADO, Superfície quente
• ATTENZJONI, Wiċċ sħun
• ETTEVAATUST, Kuum pind
• VIGYÁZAT, Forró felület
• PREVIDNOST, Vroča površina
• POZOR, Horký povrch
• ATSARGIAI, Karštas paviršius
• UZMANĪBU, Karstā virsma
• POZOR, Horúci povrch
• VARÚÐ, Heitt yfirborð
• PRZESTROGA, Gorąca powierzchnia
• FORSIKTIG, Varm overflate
• PRUDENȚĂ, Suprafata fierbinte
Technical Specifications
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Technical Support
The NVT Phybridge Technical Support Group is available to assist you with product
installation, configuration, monitoring and troubleshooting procedures. Should you
experience trouble with this equipment or for repair or warranty information, please
contact NVT Phybridge at www.nvtphybridge.com/support/ or directly through email at
Warranty: The FLEX adapters are backed by NVT Phybridge’s award-winning customer
support and 5-year warranty.
Support and Warranty
PoE Power Available to FLEX-Link
Copyright 2019 NVT Phybridge
445-0020-A
FLEX-Link 20ft
(6m)
250ft
(76m)
500ft
(152m)
750ft
(228m)
1,000ft
(305m)
1,250ft
(381m)
1,500ft
(457m)
1,750ft
(533m)
2,000ft
(610m)
Cat6 4-Pairs 50W 48 46 44 42 39 37 35 33
Cat6 2-Pairs 30W 30 29 28 26 24 22 20 18
Cat5e 4-Pairs 50W 47 44 41 38 35 33 30 27
Cat5e 2-Pairs 30W 30 28 25 23 20 18 15 12
Model Number FLEX-Link
Part Number NV-FLXLK
Dimensions 8.8cm x 5.0cm x 2.5cm (LxWxH);
3.46” x 1.97” x 0.98” (LxWxH)
Weight 106g (3.74oz.)
Interface: Network
Infrastructure side
(FLEX)
1 RJ45 port: UTP/STP cable (1-pair, 2-
pair or 4-pair)
Interface: IEEE Side
(IP Device)
1 RJ45 port; adapter is IEEE 802.3
af/at compliant and will negotiate
power requirements with IP end
device
Power Supply
PoE from the FLEX24 switch or
external power supply; maximum
50W (over 4-pairs) or 30W (over 2-
pairs)
Power
Consumption 1.5W
DC IN
Optional (sold separately)
48-56VDC via an external AC/DC
Power Adapter (IEC Class II isolated
only)
NOTE 1: Local power supply used
must have its output isolated from
Earth potential.
NOTE 2: If voltage of local power
supply is lower than the power
voltage provided from the PoE
switch, then power on the PoE
switch should be turned off.
Operating
Temperature
-40C to +70C (-40F to +158F)
Tests conducted against international
safety standard at maximum ambient
temperatures of 60ºC at 30W and 50ºC
at 50W
Mean Time Before
Failure (MTBF) 20+ years
Humidity 10% to 95% (non-condensing) at
35° C
This manual suits for next models
1
Table of contents
Other NVT Phybridge Adapter manuals

NVT Phybridge
NVT Phybridge EC-LINK+ User manual

NVT Phybridge
NVT Phybridge EC4 User manual

NVT Phybridge
NVT Phybridge FLEX-C User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge EC-Link User manual

NVT Phybridge
NVT Phybridge FLEX-Base User manual

NVT Phybridge
NVT Phybridge FLEX4 User manual

NVT Phybridge
NVT Phybridge FLEX-Link User manual