Control Panel:
::
:
LED Screen
LED Indication
1、Detection zone is normal when the LED is lit in green
2、Detection zone is intruded when the LED is lit in red
3、Detection zone is tampered when the LED blinks in green
4、Detection zone issues pre-warning when the LED blinks in red
Direction Buttons Setting Buttons
Power Switch
Power Plug
RS232-S / USB-S:Main Co port
RS232-M / USB-M:Vice Co port
to be connected with PC for Monitoring
software
I/O Expansion
Module
CH-1 ~ CH-6 Fiber plug-in in which
leading fibers are inserted in
accordance with the zone
detection in order.
P-O1 / P-C1:Controller powering relay. When
switched off, the circuit is closed, and vice versa.
T-O1 / T-C1:Optical path relay. When abnor al, the
circuit is closed, and vice versa.
IO1 / IC1 & IO2 / IC2:2 sets of alar relay. When
nor al, the circuits are open, and vice versa.
Din:External relay expansion.

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
Control Panel
Control Panel Control Panel
Control Panel Introduction
IntroductionIntroduction
Introduction:
::
:
1、Alarm Monitor
Press Select to enter ALARM MONITOR
It indicates how any counts of
intrusion happen in the detection
zone. Press BEEP OFF to eli inate
Intrusion indication when a given
zone is alar ed.
When detection is abnor al, the
figure will blink.
Press direction buttons to ALARM MONIOTR
Press Function back to SETUP MENU

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
2、Signal Monitor
Press Select to enter SINGAL MONITOR
Press Function back to SETUP MENU
Threshold
Real time
signals
Accumulated intrigue counts
1. Count is accu ulated when each the
sensing signals exceeds the thresholds.
2. Alar is issued only when the signals
exceeds the threshold within setting
Perio
d
.
Press direction buttons to SIGNAL MONITOR

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
3、Sensitivity
Press Select to enter
SENSITIVITY
Press direction buttons to SENSITIVITY
Para eters
indication
Level:The system yields sensing signal at every
mini second in order to simulate the signals
transmitted by a intruder.
Period:This is a second-based unit to simulate how
many seconds a intruder may go over the
detection zone.
Count:It refers to within preset
Period
PeriodPeriod
Period
, how many
times that signals go beyond the threshold.
Only when the three parameters are met
simultaneously, the alarms will be issued
Real Time
Signals
Accumulated
intrigue counts
1、Press direction button to ove each ite
2、Press Select to enter and adjust value
3、After setting, press Select to save the
value.
4、Apply the procedure to other para eter
setting
Press Function back
to SETUP MENU

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
4、Maintenance
Press Select to enter MAINTENANCE
Press direction buttons to MAINTENANCE
Press Function back to SETUP MENU
SF requires repair
SF/LF requires repair It indicates the performance
of the optical path
When optical path is decaying, check on the glitch is
required.
Note
NoteNote
Note:
::
:SF(Sensing Fiber)
SF(Sensing Fiber)SF(Sensing Fiber)
SF(Sensing Fiber)
/
/ /
/ LF(Leading Fiber)
LF(Leading Fiber)LF(Leading Fiber)
LF(Leading Fiber)
/
/ /
/ P(Power)
P(Power)P(Power)
P(Power):
::
:Optical Po
Optical PoOptical Po
Optical Power
werwer
wer

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
5、Grouping
Press Select to enter GROUPING
Press direction buttons to GROUPING
Press Function back to SETUP MENU
1、Press directional button to tick detection zones
2、 Press Select to group the detection zones as
ticked
3、Re ove the ticked zones by pressing Select
Grouping function:
The system can filter out the unwanted
global noise by grouping two or more
sensing zones. When activating grouping
function, even the grouped zones that
receive the signal size going beyond the
threshold will regard such event as global
noise and choose not to issue alarms.

Fiber Optic Intrusion Detection System
NS-400C/600C User Manual
Nxtar Fiber Optic Security Co.,Ltd.
6、Other
Press Select to enter OTHER
Press direction buttons to OTHER
Press Function back to SETUP MENU
Volume:Adjust the alar sound volu e fro 1 to 10.
Alarm Duration:The alar ing duration when they syste is ta pered or the
detection zone is intruded. The axi u duration is 99 seconds.
External Device:Detection Zone 1 can be integrated with other security
equip ents. When the Din pin is short, and eanwhile the zone
threshold eets the preset value, it will not issue alar . When
the Din pins are open, the syste will issue alar when the zone
threshold eets
the preset value
.
1、Press directional button to default
2、Press Select into blinking status
and adjust value
3、Activate the external device by
pressing UP & DOWN
4、Press Select to save all setting