Oakworks Medical CFPM100 User manual

Imaging Tables
USER MANUAL
www.oakworksmed.com · 717.235.6807
made in the USA
with US & imported parts
CFPM300
integrated headrest top
CFPM401
integrated headrest top
CFPM100
integrated headrest top
CFPMFXH
integrated headrest top
CFPM100
rectangular top
CFPMFXH
rectangular top
CFPM300
rectangular top
CFPM301
integrated headrest top CFPM301
rectangular top
CFPMB301
rectangular top - Bariatric Version
CFLU401
Lithotripsy Table
CFPM400
integrated headrest top CFPM400
rectangular top
CFPM401
rectangular top
CFUR301
Urology Table
CFUR401
Urology Table

© Copyright 2007
OAKWORKS®, Inc.
This manual was originally drafted
and approved in the English lan-
guage.
Printed in USA
All rights are reserved. No
part of this document may be
photocopied, reproduced or
translated to another language
without prior written consent
of OAKWORKS®, Inc.
OAKWORKS®is a registered
trademark of OAKWORKS®, Inc.
Notice
The information contained in this
document is subject to change
without notice and should not
be construed as a commitment by
OAKWORKS®, Inc.
OAKWORKS®, Inc. assumes no
responsibility for any errors that
may appear in this document nor
does it make expressed or implied
warranty of any kind with regard
to this material, including, but not
limited to, the implied warranties
of merchantability and fitness for
a particular purpose.
OAKWORKS®, Inc. shall not be
liable for incidental or consequen-
tial damages in connection with or
arising out of the furnishing, per-
formance, or use of this document
and the program material which it
describes.

TABLE OF CONTENTS
Product Use Description ...............................................................................................................1
Important Safety Instructions
Symbol Identification ..................................................................................................................1
Contradictions..............................................................................................................................1
Safety Instructions .................................................................................................................. 2-3
Product Description & Photo
CFPMFXH............................................................................................................................................ 4
CFPM100.............................................................................................................................................. 5
CFPM300.............................................................................................................................................. 6
CFPM400.............................................................................................................................................. 7
CFPM301.............................................................................................................................................. 8
CFPMB301 - Bariatric.......................................................................................................................... 9
CFPM401............................................................................................................................................ 10
CFLU401 - Lithotripsy...................................................................................................................... 11
CFUR301 - Urology........................................................................................................................... 12
CFUR401 - Urology........................................................................................................................... 13
Installation
Grounding .................................................................................................................................14
Directions for Use
Hand Control / Foot Control Operations ..........................................................................15-16
Bubble Levels.............................................................................................................................17
Angle Indicator..........................................................................................................................17
Patient Restraint Strap ..............................................................................................................17
Remove / Replace the Table Top Pad ....................................................................................18
Adjusting Cranial Positioning Pads (integrated headrest tops only)...................................18
Locking Casters Use..................................................................................................................19
Emergency Stop ........................................................................................................................19
Weight Capacity & Patient Use................................................................................................20
Urology Table Bag Hoop ..........................................................................................................20
Lithotripsy/Urology & Urology Table End Extensions.........................................................21
Lithotripsy/Urology & Urology Table Lateral Extensions....................................................21
Lithotripsy Table used as Urology Table ................................................................................22
Urology Table Lateral Extensions............................................................................................22
Carbon Fiber Arm Board ..........................................................................................................23
Adjustable T-Rail Clamp...........................................................................................................23
Spine Positioning System II......................................................................................................24
Fluoro Extender .........................................................................................................................24
Reference - Usable Imaging Area Diagrams
CFPMFXH & CFPM 100 - Integrated Headrest & Rectangular Tops ..............................25-26
CFPM400, CFPM300, CFPM401 & CFPM301 - Integrated Headrest Top.............................27
CFPM400, CFPM300, CFPM401, CFPM301 & CFPMB301 - Rectangular Top......................28
CFUR301 & CFUR401 - Urology Top ......................................................................................29
CFLU401 - Lithotripsy / Urology Top ....................................................................................30
Cleaning & Disinfection ...............................................................................................................31
Inspections & Maintenance.......................................................................................................31
Warranty Information....................................................................................................................31
Model Number & Serial Number ..............................................................................................32
Specifications
Product Specifications...............................................................................................................33
Environmental Conditions........................................................................................................33
Electrical Specifications.............................................................................................................33
Guidance and manufacturer’s declaration -
Electromagnetic emissions........................................................................................................34
Recommended separation distances........................................................................................34
Guidance and manufacturer’s declaration -
Electromagnetic immunity ..................................................................................................35-36
Contact Information ............................................................................................back cover

PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS
1
PRODUCT USE DESCRIPTION
Oakworks® Imaging Tables are radiographic tables intended for use with mobile or compact stationary C-arm
Imaging Systems. It is ideally suited for pain management imaging and therapeutic procedures. These tables are
suitable to use for diagnostic x-ray imaging and imaging during therapeutic procedures such as spinal injections,
vertebroplasty procedures and other pain management procedures. The CFLU & CFUR Tables are designed for
Lithotripsy and Urology procedures. It is intended to be operated by a healthcare professional in a medical envi-
ronment. No special training is required but a review of the following Safety Instructions is important for the safe-
ty of the operator and patient. The healthcare professional should read and understand this entire manual before
use with a patient.
SYMBOL IDENTIFICATION
This symbol, when used in this manual and on product labels, represents a caution warning. Be sure to
read and comply with all precautions and warnings.
This symbol, when used in this manual and on product labels, warns against an electrical shock hazard. Be
sure to observe and comply with all warnings.
This symbol, when used in this manual and on product labels, indicates the potential of exposure to harmful
x-rays. Be sure to read and comply with all warnings.
This symbol, when used in this manual and on product labels, indicates that the table and components
are a Type B Applied Part pursuant to IEC 60601-1: 2005.
This symbol, when used in this manual or on product labels, indicates a Protective Earth (Ground)
Terminal.
This symbol, when used in this manual or on product labels, indicates the date of manufacture of the
device.
This symbol, when used in this manual or on product labels, indicates alternating current (AC).
This symbol, when used in this manual or on product labels, indicates direct current (DC).
This symbol is used to indicate that the operator should consult the user manual.
Sitting is prohibited in this area.
~
----
CONTRADICTIONS
The Oakworks®Imaging Tables should not be used with Imaging systems having intensifier screens or film cas-
settes larger than 12 inches (30 cm) when an oblique angle of view is being used. The tables are not designed for
and should not be used with Magnetic Resonance Imaging procedures.

2
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
READ AND SAVE THESE INSTRUCTIONS
After unpacking your table, inspect it thoroughly for damage. If you suspect a problem do not use the table and
call our customer service department at 800-916-4612.
Improper use of this device can cause injury. Be sure to read all operating instructions prior to use.
Weight limit (patient and accessories): 227 kg / 500 lbs. distributed evenly. (Bariatric Table only: 340 kg / 750 lbs.)
Do not sit beyond warning line on carbon fiber top. On Lithotripsy / Urology Top - Do not sit on any extensions
(Weight Limit: 200 lbs. / 91 kg.)
The table utilizes four locking casters to permit movement of the table within the imaging suite. Accidental move-
ment of the table may occur. Lock casters prior to accomplishing imaging of the patient. Lock casters when the
patient is mounting & dismounting the table.
The table should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary,
the table should be observed to verify normal operation in the configuration in which it will be used.
The use of Accessories, transducers, and cables other than those specified (with the exception of transducers and cables
sold by the Manufacturer of this device as replacement parts for internal components) may result in increased Emissions
or decreased Immunity of the table.
The table is designed to be a standalone table used with radiographic equipment. This table must not be modified or
incorporated into any other equipment.
There may be pinch points under the table top. Do not have any body part under the top when the table is in
motion.
Be certain that the table is completely lowered prior to discharging an ambulatory patient. The patient may lose balance
and fall. NOTE: The CFPMFXH is a fixed height table. It is recommended that all patients are assisted onto the table
(physical assistance & step stools with side rails is recommended.)
Patient must be secured with Safety Restraint Strap prior to using the tables.
Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into
service according to the EMC information provided in the specifications at the end of this manual. (Excluding
CFPMFXH)
Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment. (Excluding
CFPMFXH)
This table is not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide.
Electrical Shock Hazard. (Excluding CFPMFXH) The power supply/control module is located inside the lifting
column and under the top. No user serviceable parts are inside. Refer servicing to qualified personnel. Unplug wall
connector prior to contact with any cables connected to the power supply.
To avoid the risk of electric shock, this equipment must only be connected an outlet this is properly grounded. See
GROUNDING instructions in this manual.
Grounding reliability can only be achieved when this equipment is connected to an equivalent 3 prong receptacle
marked “Hospital Only” or “Hospital Grade”.
Oakworks medical tables are designed and built to provide many years of dependable service. Please follow local
regulations and laws when disposing of the electrical components used in this table.
IMPORTANT SAFETY INSTRUCTIONS

WARNING
To reduce the risk of burns, fire, electric shock or injury to persons:
1. Unplug this furnishing from the electrical outlet before cleaning.
2. Unplug from outlet before adding or removing parts.
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or dropped into water. Contact Oakworks Customer Service before use.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
DANGER
The potential of exposure to harmful x-rays exists when this table is in use. The use of adequate x-ray barrier
devices is necessary to provide protection to both the operator and the patient. X-ray barrier devices are recommended
for the patient outside of the intended target area to prevent exposure to scattered radiation from the x-ray generat-
ing source.
The tabletop has a typical aluminum filtration equivalence of 1.10 mm as measured at 100 kVp and a half value (HVL)
of 3.6 mm. (NOTE: Bariatric Top has a typical aluminum filtration equivalence of 1.50 mm. as measured at 100 kVp
and a half value (HVL) of 3.6 mm.)
• Oakworks®Imaging Tables may be used for x-ray imaging where the x-ray generator is located below the
tabletop and the image receptor is located above the tabletop. This is the recommended method. The tables may
also be used for x-ray imaging where the x-ray generator is located above the tabletop and the image receptor is
located below the tabletop. This application will result in greater patient exposure to x-rays. The operator must
weigh this issue with the imaging requirements and patient exposure issues.
• The Imaging Tables may be used with the x-ray generator above the tabletop and a film cassette located on
the tabletop. (See contradictions regarding film cassette size.)
• The x-ray generator should never be located above the tabletop when the Oakworks®Imaging Table and
the Oakworks®Spine Positioning System/Prone Pillow are used together. This type of use requires that the x-ray
generator is located below the tabletop and the imaging intensifier or film cassette located above the tabletop.
3
IMPORTANT SAFETY INSTRUCTIONS

4
PRODUCT DESCRIPTION
STANDARD SPECIFICATIONS
Fixed Height 37” (91cm)
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg.) distributed evenly
4” (10cm) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 368 lbs. (167 kg.)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
Custom heights: 31”-37” (79-91cm)
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
CFPMFXH
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Locking
Casters
Integrated
Face Rest
with Crescent
Face Pad
Hand Rail
24” X 80” RECTANGULAR TOP
For electrical specs, see Specifications section.

5
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
CFPM100
STANDARD SPECIFICATIONS
Height Motion Powered 22”-40” (56-102cm)
Foot Control height motion
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 343 lbs. (146 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Electronic
Lift Tower
Emergency
Stop
Hand Rail
24” X 80” RECTANGULAR TOP
Locking
Casters
Integrated
Face Rest
with Crescent
Face Pad

6
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
CFPM300
STANDARD SPECIFICATIONS
Motion 1 Powered 26”-44” (66-112cm) Height Range
Motion 2 Powered +15°/-12° Trendelenburg
Motion 3 Powered ±15 Lateral Tilt
Hand & Foot Control All powered motions
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 498 lbs. (226kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm.) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
Electronic
Lift Tower
Hand Rail
Emergency
Stop
24” X 80” RECTANGULAR TOP
Locking
Casters
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Integrated
Face Rest
with Crescent
Face Pad

7
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 26”-44” (66-112cm) Height Range
Motion 2 Powered +15°/-12° Trendelenburg Tilt
Motion 3 Powered ±15° Lateral Tilt
Motion 4 Powered 10” (25cm) Longitudinal Travel
Hand & Foot Control All powered motions
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 498 lbs. (226 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
Electronic
Lift Tower
Hand Rail
Emergency
Stop
Locking
Casters
CFPM400 24” X 80” RECTANGULAR TOP
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Integrated
Face Rest
with Crescent
Face Pad

8
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
Electronic
Lift Tower
Hand Rail
Emergency
Stop
Locking
Casters
CFPM301 24” X 80” RECTANGULAR TOP
STANDARD SPECIFICATIONS
Motion 1 Powered 25”-43” (64-109cm) Height Range
Motion 2 Powered +15°/-11° Trendelenburg
Motion 3 Powered 10” (25cm) Longitudinal Travel
Hand & Foot Control All powered motions
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 538 lbs. (244 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Integrated
Face Rest
with Crescent
Face Pad

9
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
24” x 80” Bariatric Carbon Fiber
Top with Removable Table Top Pad
Electronic
Lift Tower
Hand Rail
Emergency
Stop
Locking
Casters
CFPMB301 - Bariatric
STANDARD SPECIFICATIONS
Motion 1 Powered 26”-44” (66-112 cm) Height Range
Motion 2 Powered +15°/-11° Trendelenburg
Motion 3 Powered 10” (25cm) Longitudinal Travel
Hand & Foot Control All powered motions
Rectangular Top 24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 750 lbs. (340 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 573 lbs. (260 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad

STANDARD SPECIFICATIONS
Motion 1 Powered 26”-44” (66-112cm) Height Range
Motion 2 Powered +15°/-12° Trendelenburg Tilt
Motion 3 Powered 10” (25cm) Longitudinal Travel
Motion 4 Powered ±4” (10cm) Lateral Travel
Hand & Foot Control All powered motions
Choice of Tabletop:
- Integrated Headrest
- Rectangular
22” (56cm) W x 84” (214cm) L
24” (61cm) W x 80” (203cm) L
Table Voltage Options 120V/60Hz or 230V/50Hz
Table Capacity 500 lbs. (227 kg) distributed evenly
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Crescent Face Pad Integrated Headrest Only
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 548 lbs. (249 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Headrest 2-Pad Set:
1) 2” (5 cm) High x 12” (30.5 cm) Square Pad
2) 4” (10 cm) High x 12” (30.5 cm) Square Pad
Electronic
Lift Tower
Hand Rail
Emergency
Stop
Locking
Casters
CFPM401 24” X 80” RECTANGULAR TOP
10
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
Carbon Fiber Integrated Headrest
Top with Removable Table Top Pad
Integrated
Face Rest
with Crescent
Face Pad

11
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 27”-45” (66-112cm) Height Range Urology Bag Hoop Clips onto T-rails (bag not included)
Motion 2 Powered +15°/-12° Trendelenburg Tilt Intregrated T-rails .38” (1cm) Thick x 1.13” (3cm) High US Stan-
dard
Motion 3 Powered 10” (25cm) Longitudinal Travel Patient Restraint Strap Must be used during all procedures
Motion 4 Powered ±4” (10 cm.) Lateral Travel 5” (12.5 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Hand & Foot Control All powered motions
Main Top Dimensions
23” (58cm) W x 47” (119cm) L (Radiolucent
dimensions: 19” (48cm) W x 23.7” (60cm))
Table Extensions (1) 23” (58cm) W x 28” (71cm) L - End
(1) 23” (58cm) W x 16” (41cm) L
OR
23” (58cm) W x 20” (51cm) L - Short
Table Voltage Options 120V/60Hz or 230V/50Hz (2) 8” (20cm) W x 11” (28cm) L - Lateral
Table Capacity 500 lbs. (227 kg) distributed evenly (1) 8” (20cm) W x 14” (36cm) L - Lateral
200 lbs. (91 kg) (on all extensions) (1) 8” (20cm) W x 24” (61cm) L - Lateral
Padding 1” (3cm) Comfort Foam™Upholstery Terra Touch™
Table Weight 618 lbs. (280 kg) Safety Listings FDA, cETLus, CE marked
Warranty 4 year parts, 1 year labor
OPTIONS
4” (10cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
Litho/Urology Drape
CFLU401 - Lithotripsy/Urology Top
Carbon Fiber Top with
Removable Table Top Pad
Locking
Casters
Emergency
Stop
End Extension
Short Extension
Lateral Extensions (4)
T-rail
(along each side) Hand Rail
(under end)

12
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 26”-44” (66-112cm) Height Range
Motion 2 Powered +15°/-11° Trendelenburg Tilt
Motion 3 Powered 10” (25cm) Longitudinal Travel
Hand & Foot Control All powered motions
Main Top Dimensions 23” (58cm) W x 47” (119cm) L (Radiolucent
dimensions: 19” (48cm) W x 23.7” (60cm))
Table Extensions (1) 23” (58.4 cm.) W x 28” (71.1 cm.) L - End
(2) 5” (12.5 cm.) W x 24” (61 cm.) L - Lateral
Intregrated T-rails .38” (1cm) Thick x 1.13” (3cm) High US Stan-
dard
Urology Bag Hoop Clips onto T-rails (bag not included)
Table Capacity 500 lbs. (227 kg) distributed evenly
200 lbs. (91 kg) (on all extensions)
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (2.5 cm.) Comfort Foam™
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 568 lbs. (258 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
CFUR301 - Urology Top Urology Carbon Fiber Top with
Removable Table Top Pad
Locking
Casters
Electronic
Lift Tower
Hand Rail
(at end)
T-rail
Emergency
Stop

13
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 27”-45” (69-114cm) Height Range
Motion 2 Powered +15°/-11° Trendelenburg Tilt
Motion 3 Powered 10” (25cm) Longitudinal Travel
Motion 4 Powered ±4” (10cm) Lateral Travel
Hand & Foot Control All powered motions
Main Top Dimensions 23” (58cm) W x 47” (119cm) L (Radiolucent
dimensions: 19” (48cm) W x 23.7” (60cm))
Table Extensions (1) 23” (58cm) W x 28” (71cm) L - End
(2) 5” (13cm) W x 24” (61cm) L - Lateral
Intregrated T-rails .38” (1cm) Thick x 1.13” (3cm) High US Stan-
dard
Urology Bag Hoop Clips onto T-rails (bag not included)
Table Capacity 500 lbs. (227 kg) distributed evenly
200 lbs. (91 kg) (on all extensions)
4” (10 cm.) Locking
Casters
Locking / Unlocking Casters for mobile or
permanent positioning
Padding 1” (3cm) Comfort Foam™
Patient Restraint Strap Must be used during all procedures
Upholstery Terra Touch™
Table Weight 590 lbs. (268 kg)
Warranty 4 year parts, 1 year labor
Safety Listings FDA, cETLus, CE marked
OPTIONS
5” (13cm) Locking Casters
International Electric Congurations
ACCESSORIES
Carbon Fiber Arm Board (Standard or Wide)
Spine Positioning System II
Adjustable T-rail Clamp
2” (5cm) Tabletop Pad
Fluoro Extender
CFUR401 - Urology Top Urology Carbon Fiber Top with
Removable Table Top Pad
Locking
Casters
Electronic
Lift Tower
Hand Rail
(at end)
T-rail
Emergency
Stop

14
The Imaging tables come completely assembled and ready to use. Plug the cord into a functioning outlet
that is rated for the table. (see Grounding below)
Arrange the power cord and control cords so that they will not create a tripping hazard and where
the controls are located to your liking and are conveniently accessible.
Be sure access to plug is not blocked for disconnecting the table from power.
This product must be grounded. If it should malfunction or break down, grounding
provides a path of least resistance for electrical current to reduce the risk of electric
shock. This product is equipped with a cord having an equipment-grounding conductor
and a grounding pin. The pin must be plugged into an appropriate outlet that is prop-
erly installed and grounded in accordance with all local codes and ordinances. See U.S.
sample below.
Improper connection of the equipment-grounding conductor can result in a risk of elec-
tric shock. Check with a qualified electrician or service person if you are in doubt as to
whether the product is properly grounded. Do not modify the plug provided with the
product - if it will not fit the outlet; have a proper outlet installed by a qualified elec-
trician.
Correct Implementation Incorrect Implementation
Grounding Methods
Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only.
DANGER
INSTALLATION
GROUNDING

15
DIRECTIONS FOR USE
FOOT CONTROL - ONE MOTION
Used to raise and lower the height of the table.
FOOT CONTROL - THREE MOTION
Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg,
Longitudinal Motion. Control functions dependent upon table’s features.
FOOT CONTROL - FOUR MOTION
Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height,
Trendelenburg, Longitudinal Motion, Lateral Motion. Control functions dependent upon table’s features.

16
DIRECTIONS FOR USE
HAND CONTROL - THREE MOTION
Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg,
Longitudinal Motion. Control functions dependent upon table’s features.
HAND CONTROL - FOUR MOTION
Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height,
Trendelenburg, Longitudinal Motion, Lateral Motion.Control functions dependent upon table’s features.

17
DIRECTIONS FOR USE
BUBBLE LEVELS
Bubble levels are installed on the handle end of the table to aid the operator to determine the horizontal plane.
ANGLE INDICATOR
Standard on CFLU401, CFUR401 and
CFUR301 Tables. Optional on all other
Imaging Tables.
To use angle indicator, simply press “on/off”
button on the left side of the indicator.
NOTE: Do not press “zero” unless table is
in the horizontal position.
CAUTION
PATIENT RESTRAINT STRAP
The Patient Restraint Strap must be used during all procedures to prevent the patient from
falling off the table.
The strap has Velcro® attached to the ends. The Strap is attached as follows:
1. Place the center of the strap around the patient’s waist.
Relocate the strap as necessary for adequate clearance.
2. Take the ends of the strap down around the tabletop.
Pull the strap snug underneath the table and press the two
Velcro® ends together.
3. Check the strap to assure adequate patient restraint prior
to using the Trendelenburg functions.
This manual suits for next models
9
Table of contents
Other Oakworks Medical Medical Equipment manuals