manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Olympus
  6. •
  7. Portable Generator
  8. •
  9. Olympus ESG-150 User manual

Olympus ESG-150 User manual

Other Olympus Portable Generator manuals

Olympus ESG-400 User manual

Olympus

Olympus ESG-400 User manual

Olympus USG-400 User manual

Olympus

Olympus USG-400 User manual

Olympus OME-L200 User manual

Olympus

Olympus OME-L200 User manual

Olympus USG-400 User manual

Olympus

Olympus USG-400 User manual

Olympus CLH-SC User manual

Olympus

Olympus CLH-SC User manual

Olympus ESG-410 User manual

Olympus

Olympus ESG-410 User manual

Olympus USG-410 User manual

Olympus

Olympus USG-410 User manual

Olympus CLV-160 User manual

Olympus

Olympus CLV-160 User manual

Popular Portable Generator manuals by other brands

Comdel CLF5000/PLL manual

Comdel

Comdel CLF5000/PLL manual

Outsunny 84F-006V80 Using instruction

Outsunny

Outsunny 84F-006V80 Using instruction

Icel Manaus GV-2015 User's operation manual

Icel Manaus

Icel Manaus GV-2015 User's operation manual

Stat-X 30E owner's manual

Stat-X

Stat-X 30E owner's manual

Metallwarenfabrik Gemmingen Eisemann T 18000 E operating instructions

Metallwarenfabrik Gemmingen

Metallwarenfabrik Gemmingen Eisemann T 18000 E operating instructions

Alpha ACX3100i quick start guide

Alpha

Alpha ACX3100i quick start guide

HERON 8896140 Translation of the original user manual

HERON

HERON 8896140 Translation of the original user manual

SEERS STF-V11 Operator's manual

SEERS

SEERS STF-V11 Operator's manual

JOYZIS BS100 Faq

JOYZIS

JOYZIS BS100 Faq

LIPOWER G1600 user manual

LIPOWER

LIPOWER G1600 user manual

Panasonic YD-350GL4 operating instructions

Panasonic

Panasonic YD-350GL4 operating instructions

RUNHOOD HE1200-UK user manual

RUNHOOD

RUNHOOD HE1200-UK user manual

Kohler 20EORZ Operation

Kohler

Kohler 20EORZ Operation

Powerhorse 83171 owner's manual

Powerhorse

Powerhorse 83171 owner's manual

ETQ TG4000 owner's manual

ETQ

ETQ TG4000 owner's manual

Briggs & Stratton 40265 Illustrated parts list

Briggs & Stratton

Briggs & Stratton 40265 Illustrated parts list

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Firefly Cygnus CYG2400/460/24 user manual

Firefly

Firefly Cygnus CYG2400/460/24 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ESG-150 Electrosurgical Generator
CAUTION: T
his guide is only a summary of the instructions for use of the ESG-150 Electrosurgery Generator. Be sure to reference the instruction
manual that was included with your product purchase.
ESG-150 User Flexibility
Bipolar
Neutral
On/Off
Monopolar
Graphical
User
Interface
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
Basic Level
Advanced Level
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
Monopolar Home Screen
Bipolar Home Screen
Active Mode
Active Mode
Active Socket
Active Socket
Active Socket
Active Socket
Contact Quality Monitor Contact Quality Monitor
Change Output Socket
Change Output Socket
Change Output Socket
Change Output Socket
System Setup System Setup
System Setup System Setup
Power
Adjustment
Power
Adjustment
Effect Level
Adjustment
Effect Level
Adjustment
Basic Level
Basic Level
Advanced Level
Advanced Level
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
Select Basic or Advanced Level Functionality.
1) Select the “Menu”button. 2) Select “User Level”. 3) Select “Basic” or “Advanced”
Functionality.
4) Select the “OK”button to confirm. 5) Functionality has changed on
the home screen.
ESG-150 System Operating Steps
1
2a
Turn on the ESG-150.
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
ESG-150 System Operating Steps
Select Mode: Monopolar; Bipolar.
(Optional) Select User Defined Settings.
Mode menu selection.
1) Select the mode by tapping on the desired mode located on the bottom of the touch screen.
1) Select the “Menu”.
1) Select the mode by tapping on
color bar on the touch screen.
2) Choose “Select”.
2) In the menu screen, tap to
select the desired mode.
3) Select desired setting.
3) Once selected, the home screen
will display the change.
2b
2c
3
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
ESG-150 System Operating Steps
Changing the Power Level.
Changing the Effect.
4
5
Select to adjust power level.
Select to adjust effect. (Effect is only available in the
Advanced Level Function.)
6
1) Apply the neutral electrode to the patient. 2) Connect to the ESG-150.
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
ESG-150 System Operating Steps
If the red neutral electrode lights
up and alarm tone sounds:
• Is the neutral electrode correctly
connected to the device?
• Does the neutral electrode have
sufficient contact to the skin?
Correct = Green Error = Red
Monitor Neutral Electrodes: Contact Quality Monitor.
Connect device in appropriate receptacle.
7
8
Bipolar Devices
Monopolar Devices
Neutral
Electrodes
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
Creating User Defined Settings
STEP 1
On the home screen
Select Preferred Modes
Select Power Level
Select Effect Level
Select Menu
STEP 2
Settings/Setup Screen
• Select “Save”
STEP 3
Save Setting Screen
• Enter the setting name
• Select “OK”
STEP 4
The setting will appear on the
upper right of the touchscreen.
CONTINUED ON NEXT PAGE
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
ESG-150 Operation Settings
Basic Procedures
Procedure Instrument or Technique Mode Power Effect
Snare Polypectomy:
Sessile polyp Close the snare slowly and gently PulseCut Slow 120 2
Snare Polypectomy:
Pedunculated polyp Close the snare slowly and gently ForcedCoag 20 4
Endoscopic Mucosal
Resection (EMR) Close the snare slowly and gently PulseCut Slow 120 2
Hemostasis Coagrasper SoftCoag 50 3
Sphincterotomy Sphincterotome PulseCut Fast 120 2
The above settings are examples based upon previous general clinical usage of the device. Please note that clinical staff are solely responsible for selection of an appropriate
mode and power level, dependent upon the instrument being used and the condition of the tissue being treated. Due to the heterogeneity of instruments and clinical conditions,
Olympus cannot accept liability for clinical risks arising from the use of these example settings.
Pulmonary Procedures
Procedure Instrument or Technique Mode Power Effect
Less extended lesion,
bleeding CD-6C-1 SoftCoag 40 3
Polypoid Lesion
(intraluminal mass) SD-7C-1 PulseCut Slow 50 2
Web-like Stenosis KD-31C-1 PulseCut Fast
ForcedCoag
40
40
2
3
Tissue Ablation Activate MAPC probe within a
2-5 mm distance from tissue ForcedArgon 35 N/A
For more information, contact your Olympus
sales representative, or call 800-848-9024.
www.medical.olympusamerica.com
©2019 Olympus America Inc. All rights reserved.
Printed in USA OAIET0419QRG30054
3500 Corporate Parkway, PO Box 610, Center Valley, PA 18034
Olympus is a registered trademark of Olympus Corporation, Olympus America Inc., and/or their affiliates. I Medical devices listed may not be available for sale in all countries.
BLUE PEDAL
Press to activate the
selected COAGUL ATION mode
YELLOW PEDAL
Press to activate the
selected CUTTING mode
CUT MODES COAGULATION MODES
PureCut PulseCut ForcedCoag SoftCoag
Continuous cutting
Controlled cutting with an
intermittent duty cycle of
different duration
Superficial pinpoint coagulation Deeper coagulation
High Power Cut Support (HPCS) – immediate cutting
Fast Spark Monitor (FSM) – optimized cutting power Versatile coagulation technology
ESG-150 (Electrosurgical Generator)
Quick Reference Guide
ESG-150 Monopolar Modes
The wired foot switch is an accessory and must only be used in conjunction with the compatible ESG-150 to activate
the generator.
The foot switch consists of:
• Yellow cut pedal to activate the selected cutting mode.
• Blue coagulation pedal to activate the selected coagulation mode.
• Foot switch plug (7-pin connector) to connect the foot switch with the ESG-150. The length of the connecting cable is 4m.