OLYS GPI2012A User manual

Function
Warning
Installation
1. Inductive load like refrigerator, washing machine, electric drill are well applicable.
2. stand-by comsumption only need 0.3W
3. Input voltage: 12V or 24V be option
4. safety protection device and voice alarm
5. Battery optimization function, make your battery more durable.
6. Integrate with charge controller (charge and inverter simultaneously)
1.A deficient assembly could result in damage to the device, cause function failures or potential damage to the users
2. The working device generates a high voltage which might be lethal in case of contact. So, any manipulation
of the inverter must be carried out with utmost care and meet the local rules
3. No current or voltage generating device(public grid, generator,...)may be connected to the output of the inverter because
this could result into its destruction。
PURE SINE WIVE INVERTER
1.Out of reach of unauthorized persons,specially children.
In a dry place(max.95% humidity), and in any case with no
condensation.
Not directly on top of the batteries
No easily inflammable material should be placed directly
underneath or close to the GPI. ventilation must be free,and a space of
10cm. on each side is needed for good evacuation of the internal
heat
1. connecting the consumer devices
Once the consumer devices are connected,make sure that
they are turned off before connecting the battery
2 connecting the battery
● onnect the battery observing carefully the polarity。
● Connect the battery using the fillowing colours:
BLACK cable:negative pole(-)
RED cable:positive pole (+)
When connecting the battery,there is a spark(Danger of
explosion!),because of the charging of the internal
filtering capacitors.
A fire security fuse must be installed on the battery.
c
Place where the inverter is to be installed
Connection
USER MANUAL
Thank you very much for buying our product. Please read
thoroughly before using the product
unit:mm
INVERTER INTEGRATE WITH CHARGE

USE
LED1(power)
LED1(power)
AC outpu t
LED3 (solar charge)
input sola panel (Inverter integrate with charge)
solar charge
LED2(B.L.O.)
LED2 ( B.L.O. )
ON/OFF
Ther is a switch on the inverter to activate or deactivate it.Use
this function to save the energy of the batteries when you are not
using the inverter
NOTE:
The solar charge controller remains in operation even
when the inverter is off
1. control and indicators
Acoustic indicator
"functioning"indicator(green LED1)
Power
LED2
LED3
LED4 ON: >75%
LED5 ON: >50%
LED6 Blinking: <10%
B.L.O.
Battery
capacity
Overheat: The acoustic indicator beeps 3℃ before cutting the voltage. Reduce the consumption in order to lower the inverter
temperature and to avoid the output voltage is cut off
Low battery coltage: The indicator beeps for a minute before the interruption. Reduce the consumption in order to get the battery voltage
rise and to avoid that the output voltage is cut off
continuous beep for two seconds
you have pushed the ON/OFF switch to restart the inverter. The output voltage will be immediately present after the acoustic signal. The
acoustic warning can be deactivated
The GPI inverter has on an accoustic indicator for the following cases:
(Inverter)
Alarm by voltage flickering
when the acoustic indicator is deactivated or when the inverter is out of hearing,it can be useful to be warned of an imminent inverter stop due
to an “overheat” or a “battery undervoltage”, if this function is activated ,the ouput voltage will flicker slightly(max.20%), leading to a variation of
the lights intensity and therefore indicating the imminent stop of energy supply
The user can then choose to reduce his consumption in order to secure the supply to poiority loads(for instance lighting)
Model with stand-by system
The stand-by is an energy saving system which trun off the inverter intermittently when no consumer is detected. In this mode the functionning
indicator( green LED2) blinks, showing the intermittent presence of the voltage
The detection threshold is set by default at 5W
NOTE: In this mode the output voltage is intermittently present at the output!
Activation /deactivation of functions
The follwing function of the GPI range can be freely enabled or disabled by the user:
1. acoustic warning of imminent stop of the inverter
2. Battery lifetime optimizer function
3. Imminent stop alarm by voltage flickering
ON/OFF
LED 4 LED5 L ED6
LED1
Illuminated: A 230 v Voltage is present at the output,
the inverter is on
Blinking: ----- No load(stand-by)
_ _ _ _ _The 230v voltage has been cut due
to an alarm; the inverter will automatically
resume function when the failure has disappeared
Off: The 230v voltage is not persent at the output, the
inverter is off
This indicator is illuminated only if the enhanced
Battery Lifetime Optimizer function is activated
Solar charge ON: normal Off: no charge

1
2
3
The table below will show you the different causes of inverter stopping
The state<activated> or <deactivated> of the functions is indicated by the buzzer with a continuous push on the on/off key after a duration
given for each function as per the table below:
single <beep> short=function activated
Double <beep> short = function deactivated
Function
Acoustic alarm
Bttery lifetime optimization
(B.L.O.)
Alarm by voltage flickering
Duration of impulse(onto on/off)
5 seconds
10 seconds
15 seconds
Default setting
Activated
Deactivated
Deactivated
The state is reversed if the on/off key is released within 2 seconds following the buzzer sound.
To consult the state of functions without having any effect on them or changing their programming it is possible to main the on/off key pushed
on. Beyond 20 seconds the buzzer will sound continuously to indicate the end of the sequence and willstop by the release of the key
Safe
The inverter is electronically protected, It is portected against reverse polarity by an internal fuse,The nxet table displays the various
possible default cases and their cnosequences
Caution: the inverter is not protected against the connection of an AC source(generator or grid) at its output. such connection wil
cause a major failure and should be avoided
Battery portection by LVD-low voltage disconnection battery protection:
The battery is protected from deep discharge by stopping the inverter if the battery traches a voltage lower than
0.87Unom.(10.5 or 21V)during more than 1 minute. An accoustic signal or a voltage flickering(if authorized) is activated during
1minute before the inverters stops, the inverter must then be restarted manually, it will restart antomatically if the battery voltage is
back to a value higher than 1.04*Unom(1 2 . 5 or25V),the inverter will stop immediately(with no delay) if the battery voltage is lower
than 0.75*Unom(9 or 1 8V).
CAUSE CONSEQUENCE SOLUTION
Low battery voltage
voltage<0.87*Unom
Deep discharged
battery voltaeg<0.75*Unom
Overheating
Battery overvoltage 1.33Unom
Short circuit at the output
Overload
Battery reverse polarity
inverter temporary stopped ,the green
indicator blinks
Inverter stopped
Inverter temporary stopped the green
indicator blinks
Inverter stopped
Inverter stopped
Inverter stopped
Internal fuse broken down
Automatic restart when the battery
voltage rises at 1.04*Unom
The inverter should be manually restarted
Inverter should be manually restarted when
the battery has reached=0.87*Unom
Automatic restart when the temperature
reaches the normal range
Wait until the battery voltage reaches the correct level
Push the ON/OFF button to reactivate the
inverter 1.2*Unom
Eliminate the short circuit
Push the ON/OFFbutton to reactivate
the inverter
Use the inverter only in the range of its
nominal power. Regular use in overload
power diminishes the lifetime of the inverter
Push the ON/OFF button to reactivate the inverter
Back to manufacture for testing

充电逆变一体机使用说明
12V24VLED blink number comments
10.5V21.2V0× This is aslo the LVD level
when BLO is deactivated
11V 22V -
11.4V 22.8V -
11.6V23.2V
11.8V23.6V
12V24V
12.2V24.4V
-
-
-
The solar charge controller built in option in the inverter GPI-S is meant for charging a battery exclusively from a solar generator.
Any other source of current needs an external and suitable cahrge controller
The maximum (open) voltage of the solar generator is 23V for 12V system, 46V for 24V sysetm, connect firstly the inverter to the
battery before connecting the solar generator. The adjustment mode is a I/Uuo("floating") shunt and it guarantees optimal charge
conditions along the battery lifetime
LED4 LED5 LED6 battery capacity
ON OFF OFF >75%
OFF ON OFF >2 5 - 7 5%
OFF OFF ON <25%
OFF OFF Blinking <10%
OFF OFF OFF lowvoltage protection
LED4 LED5 LED6
LED3
The yellow indicator display the functionning mode(LED3)
Illuminated: The solar charge is at its maximun
Not illuminated: the solar generator is not connected or the time is daynight
Battery lifetime Optime
Cycling a battery in permanent charging mode from 0 to 30% is often a cause of early aging of batteries, particularly in solar home systems. In
order to enhance the battery lifetime, the GPI inverter are equipped with a unique function that wil readjust the low voltage disconnection(LVD)
threshold according to the behavior of the user consumption. This allows a full recharge of the battery.
This function can be activated at anytime
An indicator(green LED2 ) is lit or blinks when this function is activated. The number of blinking indicates the LVD currently applied.
if this indicator is lit continuously, this means that the use oF the battery is correct and that it was well charged.The LVD is then set
at 0.87*Unom(10.5 or 21v) as per the model. This also means that you have the widest availaility of the energy stored and that
your battery is likely to last longer
If the indicator is blinking one or several times,this means that the use of the battery is restricte and that the disconnection voltage
was set according to the table below(±2%)
level at BLO activation
This strategy will off course restrict the use of the battery and drive the user to reduce nisconsumption
or to increase the production (by an additional charger connected to a backup solar generator for instance)
Inverter integrate with charge(Option-s)
Battery capacity display
connection
sola panels battery
1×off
2×off
3×off
4×off
5×off
6×off

Pure sine wave inverter technical data
MODEL GPI301 2AGPI4 012 AGPI5012AGPI 602 4A
Battery voltage(Vdc)
Input voltage(Vdc)
Output voltage(Vdc)
Output frequency(HZ)
Continuous/30 'power(VA)
Stand-by/ON@no load(W)
Maximum efficiency(% )
Dimensions(mm)
Weight(kg)
Load detect.(stan-by)
Overheating protection
Short circuit protection
IP protection index/IP
Cosφ
50H Z
250 /3 00W
93%
5W
YES
YES
YES
IP3 0
0.1 -1
50H Z
300/400W
93%
5W
YES
YES
YES
IP3 0
0.1 -1
50H Z
400/500W
93%
5W
YES
YES
YES
IP3 0
0.1-1
21- 32 Vdc
50H Z
500/600W
94%
5W
YES
YES
YES
IP3 0
0.1 -1
0.3 W/ 9.6 W 0.3 W/9 .6 W 0.3W/9.6W 0.3 W/1 4W
240×2 05 ×93
4.5 kg
240×2 05 ×93
4.5 kg
240×205×93
4.5kg
240×2 05× 93
4.5 kg
GPI 20 12A
12Vdc
10. 5- 16V dc
AC2 30 Vac
50HZ
150/200W
93%
5W
YES
YES
YES
IP30
0.1-1
0.3W/9.6W
240×2 05× 93
4.5kg
GPI301 2A-SGPI4 012 A-SGPI5012A-SGPI 6024A-S
50H Z
250 /3 00W
93%
5W
10A
YES
YES
YES
IP3 0
0.1 -1
50H Z
300/400W
93%
5W
20A
YES
YES
YES
IP3 0
0.1 -1
50H Z
400/500W
93%
5W
20A
YES
YES
YES
IP3 0
0.1-1
50H Z
500/600W
94%
5W
20A
YES
YES
YES
IP3 0
0.1 -1
0.3 W/ 9.6 W 0.3 W/9 .6 W 0.3W/9.6W 0.3 W/1 4W
240×2 05 ×93
4.5 kg
240×2 05 ×93
4.5 kg
240×205×93
4.5kg
240×2 05×93
4.5 kg
GPI2012A-S
50HZ
150/200W
93%
5W
10A
YES
YES
YES
IP30
0.1-1
0.3W/9.6W
240×2 05× 93
4.5kg
12V dc 1 2Vd c 12V dc 24V dc
10. 5- 16V dc 10 .5- 16 Vdc 10. 5- 16V dc
AC2 30 Vac AC230Vac AC230Vac AC230Vac
12V dc 1 2Vd c 12V dc 1 2V dc 2 4Vd c
21- 32 Vdc10. 5- 16V dc 10. 5- 16V dc 10 .5- 16 Vdc 10. 5- 16V dc
AC2 30 Vac AC2 30V ac AC230Vac AC230Vac AC230Vac
Inverter integrate with charge
Overload protection
MODEL
Battery voltage(Vdc)
Input voltage(Vdc)
Output voltage(Vdc)
Output frequency(HZ)
Continuous/30 'power(VA)
Stand-by/ON@no load(W)
Maximum efficiency(% )
Dimensions(mm)
Weight(kg)
Load detect.(stan-by)
Overheating protection
Short circuit protection
IP protection index/IP
Cosφ
Overload protection
solar charge controller
This manual suits for next models
9
Other OLYS Inverter manuals
Popular Inverter manuals by other brands

SEW-Eurodrive
SEW-Eurodrive MOVITRAC B MC07B0003-2B1-4-00 System manual

Baldor
Baldor IDLC100-3J installation manual

Grape Solar
Grape Solar GS-P-220-Fab5 Safety and installation manual

Weco
Weco ESS XTE Series user manual

enertik
enertik ETS-S00VA instruction manual

Vaillant
Vaillant auroTHERM VTK 570/2 Installation and maintenance instructions

Caiman
Caiman Lektrafuse Instructions for use

KSolare
KSolare KSY-60KW Series user manual

Novatech
Novatech 409B instruction manual

Brivis
Brivis ICE DONSC13Z7 INSTALLATION, START-UP, MAINTENANCE INSTRUCTIONS & USER OPERATING GUIDE

Growatt
Growatt MID 11-30KTL3-XH quick guide

Samlexpower
Samlexpower Evolution Series owner's manual