3
2 USER GUIDE
2.1 Configuration
2.1.1 Power Configuration
The unit can operate in several different power-on modes:
MODE
#ON/OFF
SWITCH DESCRIPTION
A. Unit turns ON when
ON switch pressed
and Off when OFF
switch pressed.
•When unit is first turned ON or any time the ON button is pressed, data is transmitted
•When a change of state takes place, data is transmitted.
•If a function is still active (button is held) data is transmitted every 1 out of 10 packets.
•If no functions are active, data is transmitted 1 packet out of 30.
•If STOP is pressed, data is transmitted and then transmitter turns OFF. Receiver outputs will
default to initial state.
B. " •same as Mode 1 except that outputs retain last state on sending STOP.
C. Unit turns ON when
any function
depressed
•When a button is pressed, data is transmitted
•Transmitted will timeout in 30 seconds
•If STOP is pressed, all outputs in the receiver shall revert to their default state.
2.1.2 Output Configuration
A. MOMENTARY
Outputs directly reflect inputs. Outputs are ANDed with 'MAIN" function. This means
that if a button is pressed and the RF carrier is lost, the output will automatically clear.
1 2
3 4
5 6
7 8
STOP
ON
RG
AB
CD
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
A
MOMENTARY
INPUT
PAIRS
1
2
3
4
OUTPUT
PAIRS
1
2
3
4
CONFIGURATION
OPTION
SETTING THE CONFIGURATION OPTIONS
B
TOGGLE
C
INTERLOCKED