Product Overview
Gate Machine mounted Wall mounted
F800W intelligent terminal is a convenient and safe temperature
measuring terminal for visual face recognition. The product can be
applied to the traffic scene of intelligent community, access control
channel, face attendance, hotel, office building, school, shopping
mall and so on, which is helpful to realize intelligent safety control.

Product characteristics
•Using non-contact matrix to obtain measured temperature
•A self-developed temperature algorithm to achieve accurate temperature measurement ,1 S rapid
temperature measurement
•Support Binocular In vivo Detection Support for Human Motion Face Tracking Exposure in Strong Inverse
Light Environment
•5W Face recognition time in vivo detection is less than 0.2 seconds under face database
•The CPU uses Hayes 3516 DV300u operation Linux system, the system is stable
•Abundant hardware interface (Wigan, RJ45)
•8 inch IPS screen, resolution 800*1280
•IC card unlock, face recognition unlock, QR code unlock, etc.

Hardware specifications
Name Specificatin/model Note
CPU Hi3516DV300 Hayes 3516 DV300
Systems Linux
Camera Sensor Double MiPi
Quantity :2
pixels :200 W
White Light Lamp Yes
Infrared Light Yes
Display screen IPS screen 8 inches 800*1280
RAM 1GB
ROM 4GB
WIFI Support
Bluetooth Support
4G Net access Support
MIC MIC
Speakers 8Ω1W
Network 10/100/1000 Mbps Ethernet (support POE+ power supply)
Power supply Adaptor DC12V/2A
Vegan Support Wegan send and Wegan receive, support Wegan 26,34 format
Relay interface COM/NO/NC
GPIO interface Support three-way extension, extended interface use configurable (door magnetic input, door
button
signal
input, smoke alarm input, doorbell signal output)
Alarm
Protection Micro-touch switch Support
Indicator on standby, breathing light.At work, Chang Liang.
Remote control Remote control open

1. Gate Installation
Temperature measurement module
White Light Lamp
Camera
D i splay s creen
Credit card a rea
grip n ut
stand t ype support

1.1 Installation Steps and Schematic Schemes
1. A round hole of 32 mm is opened at the gate position as shown;
2. through all wire locking nuts;
3. Connect according to electrical wiring mode;
Top view Side view
G ate hole size
F ront panel of gate
C o n tact Point of
N e t work Open Door
S i g nal Module
R e l ay module
P o w er port
n etwork port
P o r t connection
I D c ard reader

1.2 Electrical wiring
1. From the top down for the relay often on, power, network cable.
2. Wiring photos
3. Interface definition
Serialnumber Name
Number
Remarks
1Network 1 RJ45
2Power supply 1 DC12V IN
3USB 1 USB2.0
4Switch output 1 KZ_OUT +NO KZ_OUT -
COM
5Wegan Protocol Input Interface 1
①VCC 12V
②GND
③D0
④D1
6The output interface of Wegan
Protocol 1
①vcc12V
②GND
③D0
④D1

2. wall mount
Temperature measurement module
White L ight Lamp
Camera
Display s creen
Credit card a rea
fix screw
Wall m ount s upport
fix screw

2.1 Installation Steps and Schematic Schemes
1. Attach the positioning film to the installation equipment position and open the hole according to the positioning film position
2. Electrical wiring mode good wiring:
3. Remove the positioning film, wire through the back hole with M3*20mm screws fixed the machine;

2.1 Installation Steps and Schematic Schemes

2.2 Electrical wiring
1. From the top down for the relay often on, power, network cable.
2. Wiring photos
3. Interface definition
Serial number Name Number Remarks
1Network 1 RJ45
2Power supply 1 DC12V IN
3USB 1 USB2.0
4Switch output 1 KZ_OUT +NO
KZ_OUT
-COM
5Wegan Protocol
Input Interface 1
①
VCC 12V
②
GND
③
D0
④
D1
6The output
interface of Wegan
Protocol 1
①
vcc12V
②
GND
③
D0
④
D1

3. equipment start-up
1. After the equipment is plugged into the power supply,
the software starts itself;
4. recommended installation environment
1. Equipment for indoor use only, should avoid direct sunlight, avoid wind;
2. Application temperature :10~50 degrees Celsius;
3. Recommended installation height of 1.5 m, specific can be adjusted according to the actual situation;
4. Better to keep the ambient light intensity above 100 lux;
Note: If the current ambient temperature is outside the 10-50°C range, the temperature is too low or too high
High condition, can carry on the temperature compensation through the background, has measured the temperature gun actually to measure the
temperature to be accurate,
± compensation is carried out for the actual temperature measured by the equipment, and the accuracy of the equipment temperature measurement is
±0.3 degrees Celsius.

5. FAQ treatment
5.1 Equipment unable to start or crash
1. If the equipment can not start up, check whether the positive and negative poles of the equipment power supply are connected back or whether the
input voltage is insufficient, it is recommended to use DC 12V/2A, Note that too long wiring length will affect the input voltage;
2. When the device is unable to perform an exit or termination operation, power it up reset and restart by cutting off and switching it on again.
3. Check equipment input voltage, recommended DC 12V/2A;
5.2 No face recognition or low recognition rate
1. In the process of recognition, whether there is part occlusion or whether the face is in the recognition area;
2. The light is darker and the brightness of the lamp is improved.
3. Strong inverse light environment, try to adjust the installation angle or height, as far as possible to make the face terminal in vertical or down angle state;

5. FAQ treatment
5.3 Gate not open
1. Check whether the network connection is normal, re-plug;
2. Check whether the Wigan signal line is connected properly and re-plug;

6. considerations
▲do not immerse the machine in water in whole or in part separately to avoid damage to the equipment;
▲this machine is absolutely not allowed to move or vibrate violently while working;
▲please pay attention to switch the machine according to the normal steps to prolong the machine life;
▲Hold the plug when pulling the power cord, do not hold the cable;
▲Do not put this equipment upside down;
▲Do not let any foreign matter fall into the inside of this equipment to prevent short circuit or cause equipment damage;
▲If the equipment fails or foreign objects enter the internal, immediately disconnect the power supply and consult the manufacturer or seller;
▲Do not put the equipment on a dangerous platform to prevent the equipment from falling, smashing, wounding, or damage to the equipment itself;
▲The power plug should be unplugged when cleaning the equipment.
▲Clean the machine with a soft dry cloth or a soft cloth with a small amount of cleaning agent. Do not use any solvent that will damage the surface coating,
such as alcohol or benzene;

6. considerations
▲Do not soak all or part of the machine in water alone to avoid damage to the equipment;
▲The machine is absolutely not allowed to move or violent vibration;
▲Please pay attention to switch the machine according to the normal steps to extend the machine life;
▲Handle with care;
▲Do not attempt to disassemble or repair the equipment;
▲Qualified technicians may be requested to maintain or contact the maintenance centre when:
a) Damaged or worn out power cord or plug;
b) The abnormal placement or use of the equipment causes water to enter the equipment;
c) Damage to casing or panel caused by equipment drop;
d) Equipment can not be used properly in accordance with this manual;
e) There are other obvious anomalies in the equipment, such as lighting, camera without imaging, no gate control signal output.
▲After the equipment inspection and maintenance is completed, the staff shall be required to carry out routine safety checks to ensure that the equipment
is in a safe operation state.
Table of contents
Popular Thermometer manuals by other brands

miniland
miniland thermoadvanced easy manual

Williams-Sonoma
Williams-Sonoma DF-10WS V4 instruction manual

Omega Engineering
Omega Engineering HH806U instruction sheet

Medline
Medline MDS9950 troubleshooting guide

Weber
Weber iGrill Mini quick start guide

No Touch Thermometers
No Touch Thermometers THD2FE manual