manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Omnitron Systems Technology
  6. •
  7. Transceiver
  8. •
  9. Omnitron Systems Technology FlexPoint 10AUI/T User manual

Omnitron Systems Technology FlexPoint 10AUI/T User manual

Warning
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
thanthatcontainedintheoperatinginstructions,unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.
Caution
All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
YEARS from the date of shipment. A LIFETIME warranty
maybeobtainedbytheoriginalpurchaserbyREGISTERING
this product with Omnitron within 90 days from the date of
shipment.TOREGISTER,COMPLETEANDMAILORFAX
THEREGISTRATIONPORTIONOFTHISINSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
register your product on the internet at http://
www.omnitron-systems.com. During thewarranty period,
Omnitronwill,at itsoption, repairor replacea productwhich
isprovento be defective.
Forwarrantyservice,theproductmustbesenttoanOmnitron
designatedfacility,atBuyer’sexpense.Omnitronwill paythe
shippingcharge toreturn theproductto Buyer’s designated
USaddressusing Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenanceof the equipment byBuyer,Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including
removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or
misuse, or operating outside the environmental
specification of the product (including but not limited to
voltage, ambient temperature, radiation, unusual dust,
etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusiveremedies.Omnitronshallnotbeliableforany
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Form: 040-04321-001C 11/07
Technical Support:
For help with this product, contact our Tech. Support:
Phone: (949)250-6510
Fax: (949)250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618 USA
E-mail: supp[email protected]
URL: http://www.omnitron-systems.com
User Warranty Registration
Pleaseregisteron-line@ http://www.omnitron-systems.com orcomplete both sides
and mail or fax this registration form to:
FlexPoint Type: __________________________________________
Model: _________________________________________________
Serial Number: ______________ Purchase Date:______________
Purchased From: _________________________________________
Address: ______________________________________________
City: ___________________ State: _______ Zip Code: ________
Country: _______________________________________________
Comments and Suggestions: _______________________________
______________________________________________________
______________________________________________________
Please complete both sides of this form
FlexPointTM 10AUI/T User Instructions
Description:
The FlexPointTM 10AUI/T transceiver is an IEEE 802.3
compatibleEthernet unshielded twistedpair (UTP) trans-
ceiverthatprovidesphysical mediumconnectiontodevices
featuringAttachmentUnitInterface (AUI) connectors. It
canbe powered from theAUI connector, an externalAC
or48VDC power adapter or a 14-unit Powered Chassis.
TheFlexPoint10AUI/Thasa 15-pin AUI connector that
attachesto a mating AUI connector mounted on hosting
EthernetDTE equipment such as a workstation or aPC,
or on a repeater such as a hub or a switch.
This FlexPoint 10AUI/T model is described here:
Model Maximum Distance
4321 100 meters
Operating in Half-Duplex, the FlexPoint 10AUI/T fea-
tures a switch selectable SQE test function that pro-
vides diagnostic information to the hosting station. It also
provides LED status about network conditions that assist
in network installation and maintenance.
The4321 modelcanbe used stand-alone,wall-mounted,
rack-mounted on a 5-unit shelf or in a 14-unit AC or
48VDC Powered Chassis.
Power Adapter Notice:
1. When using in a stand-alone configuration, this
product can be powered from the AUI port and does
not require an external power source.
2. If the AUI port is not capable of providing power to
the FlexPoint 10AUI/T and when using in a stand-
alone configuration, this product is intended to be
and must be used only with a Listed Direct Plug-In
Power Unit marked “Class 2” and rated at 9Vdc, 1
Amp.
3. When using an external power source, this product
should always be used only with Omnitron Supplied
Power Unit model number 9113-PS.
Mounting and Cable Attachment:
The FlexPoint 10AUI/T can be mounted using a wall-
mounting kit. It can also be rack-mounted using a
5-Module shelf or a high-density 14-unit FlexPoint
Powered Chassis.
Connect the FlexPoint 10AUI/T to the 15-pin AUI port
onaPC, workstation, hub or switch; slide the connector
latch locking it into place. The AUI cable is limited to 50
meters . Attach a UTP category 3 or higher cable to
the RJ45 connector. Note that the total length of the
cable should not exceed 100 meters.
Switch Settings:
“RJ45Cross-Over”Switch: When connectingthe UTPto a
hub or switch, set switch to “Straight-Through” (factory
setting). When connecting to a workstation, set it to “Cross-
Over.”
“SQE”switch: WhenattachingtoaPC (oraworkstation),
the SQE switch should be set to “SQE Enable” (factory
setting). Whenconnecting to a hub or a switch,itshould
be set to “SQE Disable.”
“UTP Range” switch: Set this switch according to the
required distance of the UTP connection. For normal
operation,setit to”100m” (factorysetting). When distance
of over 100m is required, set it to “>100m”.
Notethat when usedinthe “>100m” mode,the sensitivity
of the FlexPoint 10AUI/T is increased making it more
sensitive both to signal and noise, so this mode should
be used with caution when the distance requires it.
LED Indicators:
LED Color Description
Power Yellow Power applied
AUI-Rx Green Host Data Received
UTP-Link/Rx Green UTP Link / Data Received
Collision/
Jabber Yellow Collision or Jabber Detected
User Warranty Registration
Please register on-line @ http://www.omnitron-systems.com or complete both sides
and mail or fax this registration form to:
Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618, USA
Fax: (949) 250-6514
Name: _________________________________________________
Company: ______________________________________________
Address: ______________________________________________
______________________________________________
City: ___________________ State: _______ Zip Code: ________
Country: _______________________________________________
Phone: ____________________ Fax: _______________________
E-mail:_________________________________________________
Please complete both sides of this form
WARNING!
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.

Popular Transceiver manuals by other brands

Kenwood TS-180S instruction manual

Kenwood

Kenwood TS-180S instruction manual

Icom IC-M510 instruction manual

Icom

Icom IC-M510 instruction manual

Connect Systems CS1000 user manual

Connect Systems

Connect Systems CS1000 user manual

Jupiter Avionics JA33-001 Installation and operating manual

Jupiter Avionics

Jupiter Avionics JA33-001 Installation and operating manual

Simrad WBAT Setting up

Simrad

Simrad WBAT Setting up

Kenwood TH-27 Series instruction manual

Kenwood

Kenwood TH-27 Series instruction manual

RC4 LumenDimMIO-100 quick start guide

RC4

RC4 LumenDimMIO-100 quick start guide

QRP Labs QCX-mini CW Assembly instructions

QRP Labs

QRP Labs QCX-mini CW Assembly instructions

Vertex Standard VX-5500V Alignment Guide

Vertex Standard

Vertex Standard VX-5500V Alignment Guide

Kenwood TM-221A Service manual

Kenwood

Kenwood TM-221A Service manual

Silicon Laboratories Si4455 Series manual

Silicon Laboratories

Silicon Laboratories Si4455 Series manual

Kenwood TH-25A Series instruction manual

Kenwood

Kenwood TH-25A Series instruction manual

Vertex Standard VX-6000V Service manual

Vertex Standard

Vertex Standard VX-6000V Service manual

Yaesu FTDX101MP manual

Yaesu

Yaesu FTDX101MP manual

Hope RF RF12B Programming guide

Hope RF

Hope RF RF12B Programming guide

l-com LCTP-10BT-10B5 installation guide

l-com

l-com LCTP-10BT-10B5 installation guide

Trio TS-440S instruction manual

Trio

Trio TS-440S instruction manual

Entel HX402 HX422 user guide

Entel

Entel HX402 HX422 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.